• 제목/요약/키워드: horizontal loading test

검색결과 208건 처리시간 0.025초

랙크식 창고 화재의 수직 확산 방지를 위한 수평차단막과 In-Rack 스프링클러 적용에 관한 실험연구 (An Experimental Study on the Application of Horizontal Barrier and In-Rack Sprinklers to Prevent Vertical Spread of Rack-type Warehouse Fires)

  • 박문우;홍성호;최기옥;최돈묵;김수진
    • 한국안전학회지
    • /
    • 제34권5호
    • /
    • pp.15-21
    • /
    • 2019
  • A rack-type warehouse has the advantage of storing a large amount in a small area by loading goods vertically. But in terms of fire risk, the fire load is very high, which can cause massive damage in the event of a fire. In the United States, research has been actively conducted to minimize the spread of vertical fires, and relevant standards have been established and operated. In Korea, research and related standards are insufficient to prevent the vertical spread of rack-type warehouse fires. In this study, an experimental study was conducted to prevent the vertical spread of a rack-type warehouse fire using a horizontal barrier and in-rack sprinklers. As a result of the test, the horizontal barrier considering the continuous flame prevented the vertical spread of the flame for a certain time. However, the horizontal barrier with continuous flame did not show the effect of preventing continuous flame. The combination of the horizontal barrier and the in-rack sprinkler prevented the vertical spread of fire effectively. In addition, the heat collecting effect through the horizontal barrier was shown and helped the early operation of the in-rack sprinklers.

버켓형식 해상풍력기초의 수평 하중과 모멘트 저항력 평가 (Evaluation of Horizontal Load and Moment Capacities of Bucket-Type Offshore Wind Turbine Foundation)

  • ;윤종찬;손수원;김진만
    • 한국지반환경공학회 논문집
    • /
    • 제22권1호
    • /
    • pp.5-12
    • /
    • 2021
  • 경제적으로 효율적이고 설치가 용이한 버켓기초는 해상풍력발전기초로 적용함에 있어 좋은 방법이 될 수 있다. 이에 본 논문에서는 3차원 유한요소해석을 통해 버킷기초 적용시 기초 주위의 석션케이슨과 지반의 거동을 파악하여 분석하고자 한다. 다양한 하중조건에서 조밀한 사질토 지반과 중간 밀도의 사질토지반에 설치된 기초의 구조를 검토하고 이를 바탕으로 사질토 지반에 설치된 버켓기초의 극한하중 허용량과 회전 모멘트 허용량을 평가하였다. 그 결과, 단일하중에 의한 버켓기초의 회전과 변위는 기초의 구조적 형상, 지반 밀도, 하중편심에 크게 영향을 받는다는 것을 확인할 수 있었다. 이러한 극한 수평하중과 회전 모멘트 허용량의 결과를 바탕으로 정규화 도표와 제안식을 제안하였고, 이는 향후 해상풍력발전기초의 설계 시 유용하게 사용될 것으로 판단된다.

Seismic behavior of steel reinforced concrete (SRC) T-shaped column-beam planar and 3D hybrid joints under cyclic loads

  • Chen, Zongping;Xu, Jinjun;Chen, Yuliang;Xue, Jianyang
    • Earthquakes and Structures
    • /
    • 제8권3호
    • /
    • pp.555-572
    • /
    • 2015
  • This paper presents an experimental study of three two-dimensional (2D/planar) steel reinforced concrete (SRC) T-shaped column-RC beam hybrid joints and six 3D SRC T-shaped column-steel beam hybrid joints under low cyclic reversed loads. Considering different categories of steel configuration types in column cross section and horizontal loading angles for the specimens were selected, and a reliable structural testing system for the spatial loading was employed in the tests. The load-displacement curves, carrying capacity, energy dissipation capacity, ductility and deformation characteristics of the test subassemblies were analyzed. Especially, the seismic performance discrepancies between planar hybrid joints and 3D hybrid joints were intensively compared. The failure modes for planar loading and spatial loading observed in the tests showed that the shear-diagonal compressive failure was the dominating failure mode for all the specimens. In addition, the 3D hybrid joints illustrated plumper hysteretic loops for the columns configured with solid-web steel, but a little more pinched hysteretic loops for the columns configured with T-shaped steel or channel-shaped steel, better energy dissipation capacity & ductility, and larger interlayer deformation capacity than those of the planar hybrid joints. Furthermore, it was revealed that the hysteretic loops for the specimens under $45^{\circ}$ loading angle are generally plumper than those for the specimens under $30^{\circ}$ loading angle. Finally, the effects of steel configuration type and loading angle on the seismic damage for the specimens were analyzed by means of the Park-Ang model.

Sheet Pile 설치에 따른 SCP개량지반의 거동 (Behavior of SCP Improved Ground with Installation of Sheet Pile)

  • 유남재;박병수;정길수
    • 산업기술연구
    • /
    • 제22권B호
    • /
    • pp.211-218
    • /
    • 2002
  • The paper is to show the behavior of composit ground which is installed with sheet pile in soft soil improved by sand compaction pile. The results of load-settlement relationship, earth pressure, stress concentration characteristics, and final water content were obtained by centrifuge model test. Two cases of tests, installation of sheet pile on the corner and both side of the loading plate for the improved SCP ground which was designed twice of the footing width, were performed for the tests under the vertical and horizontal loading and both side of corner. Finite element program(CRISP) for sand compaction pile using elasto-plastic model and numerical analysis for soft soil using modified cam-clay constitutive equation were compared and analized with the results of model tests. The result of analysis show the increased bearing capacity of soil after, SCP and sheet pile was installed.

  • PDF

상재하중 하의 Soil Nailing System의 모형실험 (Model Tests of Soil Nailing System under Surcharges)

  • 유남재;유건선;김재일
    • 산업기술연구
    • /
    • 제14권
    • /
    • pp.77-87
    • /
    • 1994
  • This research is an experimental work of investigating the behavior of soil nailing system under surcharges whereas most of them were concentrated on evaluating its capacity under selfweight of excavated ground. Model tests in laboratory were performed to investigate the ultimate bearing capacity of soil nailing system under surcharges in forms of strip loading. Tests were carried out to find parameters controlling its capacity such as length of nail, vertical and horizontal spacings between nails, inclination of nail installation, and loading position of surcharges. Failure mechanism of forming failure line due to surcharge to soil nailing system was also observed by using dyed sand and monitoring its behavior. From results of these test, effects of parameters was analyzed qualitatively. Thus, this experimental results could provide meaningful data to analyze and design this system later.

  • PDF

블록식 보강토 옹벽의 정적성능 평가 (Static Performance of Reinforced Soil Segmental Retaining Wall)

  • 고태훈;이성혁;이진욱;황선근;박성현;이승훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 춘계학술대회 논문집
    • /
    • pp.46-52
    • /
    • 2003
  • In this study, the full scale testing method of the geogrid-reiuorced soil Segmental Retaining Walll(SRW) under the simulated train loading were proposed in order to evaluate the applicability of reinforced soil SRW in railway embankment. The train loading was simulated by the design static wheel load and the impact coefficient due to the train passing velocity. This test was focused on the static performance of reinforced soil SRW in terms of the following measuring systems ; the horizontal earth pressure displacement acting on the facing block and the tensile strain along the geogrid. The data gathered from this full scale testing was compared with numerical analysis results by FLAC.

  • PDF

수직 행거 내진설계용 스티프너의 단조 압축 실험 (Monotonic Loading Tests on Seismic Stiffeners for Vertical Hangers)

  • 오창수;공하성
    • 대한안전경영과학회지
    • /
    • 제25권2호
    • /
    • pp.187-192
    • /
    • 2023
  • In piping systems, trapeze hangers are subjected to vertical and horizontal seismic loads and stiffeners are used. In this study, monotonic compression tests were conducted with the removable stiffeners using three variables: stiffener clamp fixing position, section length, and installation direction. The maximum load reinforced with stiffeners could withstand a compressive load of 11kN by applying a safety factor of 10%. It could be estimated that the fixing clamp spacing or the length of shape and load had a proportional relationship. And the stiffener must be fixed in the direction of the strong axis on hinge parts. Also the stiffener buckiling load design proposes to use a method of calculate the flexural buckling compressive strength of and unreinforced full threaded bolt.

근접 굴착시 흙막이벽 버팀대 선행하중 재하에 따른 터널의 거동 (Behavior of Tunnel Due to Adjacent Ground Excavation with Pre-loading on Braced Wall)

  • 김일;이상덕
    • 한국지반공학회논문집
    • /
    • 제23권10호
    • /
    • pp.163-174
    • /
    • 2007
  • 큰 선행하중을 가할 수 있는 새로운 선행하중 시스템을 개발하였으며, 이를 적용하여 근접굴착 시 기존 터널의 안정성을 확보하는 방안을 연구하였다. 흙막이 벽체의 수평변위가 거의 생기지 않도록 설계축력 이상의 선행하중을 가하였다. 이를 위해 선행하중을 가하지 않는 경우와 선행하중을 가하는 경우에 대해 축소율 1/10인 실 대형 시험을 실시하였다. 수치해석은 선행하중을 가하지 않는 경우와, 선행하중을 설계축력의 50%와 100%를 가하는 경우, 흙막이 벽체 변위를 거의 발생시키지 않는 크기의 선행하중을 가하는 경우에 대해 유한요소법(FEM) 프로그램인 PLAXIS를 사용하여 수행하였다. 그 결과 선행하중을 설계축력 이상으로 적용시켜 흙막이 벽체변위를 억제시켰을 때 벽체 배면 지반에 있는 터널의 안정성이 크게 향상되는 것을 확인할 수 있었다.

대형재하시험을 통한 원지반 부착식 패널옹벽의 거동특성 (Behavior Characteristics of Precast Concrete-Panel Retaining Wall Adhered to In-situ Ground through Large Scaled Load Test)

  • 신윤철;민경남;김진희;안태봉
    • 한국지반환경공학회 논문집
    • /
    • 제17권11호
    • /
    • pp.45-53
    • /
    • 2016
  • 패널식 옹벽은 지보재를 통한 선지보 개념으로 프리캐스트 패널과 체결하여 원지반 강도를 최대한 보호하며 보강하는 공법이다. 최근 건설공사에서 대규모 깎기비탈면의 형성에 따른 토공량 증가와 환경 훼손을 최소화하고 용지제한에 따른 토지의 효율적인 이용을 위해 패널식 옹벽의 적용이 증가하고 있는 추세이다. 원지반 부착식 패널옹벽은 자연암반 질감을 갖는 프리캐스트 콘크리트 패널을 사용하여 경관성을 향상시키고 완전한 Top-Down 시공법을 구현하도록 개발된 공법으로 수직절취와 패널의 원지반 직접부착이 가능해 비탈면 이완을 최소화하고 터파기 및 되메우기 공종을 배제하여 시공성을 개선하였다. 본 연구는 현장시험시공을 수행하여 수직절취 및 Top-Down에 대한 시공성을 확인하고, 대형재하시험과 하중단계별 계측결과를 분석하여 원지반 부착식 패널옹벽의 거동특성을 분석하였다.

지중에 근입된 콘크리트전주의 실물 수평재하실험에 의한 수평토압과 변위특성 (Lateral Earth Pressures and Displacements through Full Scaled Lateral Loading Test of Concrete Electric Pole Embedded in Ground)

  • 안태봉
    • 한국지반환경공학회 논문집
    • /
    • 제12권4호
    • /
    • pp.43-51
    • /
    • 2011
  • 연약지반에 시공하는 많은 콘크리트전주가 외부하중으로 전도파괴가 발생하는데 본 연구에서는 실물인장실험을 실시하고 근가위치, 근가깊이, 근가개수, 전주근입깊이를 달리하면서 전주에 작용하는 수평토압을 분석하였다. 실물실험은 10가지 종류로 나누어 실험한 결과 수평토압은 전주 근입깊이가 클수록 커지고 하부수동영역이 길어지는 것으로 나타났다. 근가 설치위치가 깊을수록 하부수동영역 토압이 감소된다. 변위는 근가의 위치 및 수량, 전주기초의 근입깊이에 따라 뚜렷한 차이를 나타냈다. 초기하중 재하 시 상부에서 굴절된 양상을 보이다 점증하중에 따라 전주의 중앙부로 굴절의 양상이 전이되었다. 근가위치는 G.L(-) 0.5m인 상태에서 전주기초 깊이 1.3m를 추가로 근입 시 최대 수평변위는 약 1.6배의 감소를 보여 전주의 안정성이 증가하였다.