• Title/Summary/Keyword: horizontal

Search Result 10,949, Processing Time 0.047 seconds

한반도 근해의 해류와 해수특성 -ll. 여름철 제주도 주변해역 중저층에 출현하는 수괴의 지리적 분포와 화학적 특성- (A Study on Sea Water and Ocean Current in the Sea Adjacent to Korea Peninsula -II . Geographical Distribution and Chemical Characteristics of Different Mid-Bottom Waters in the Neighbouring Sea of Cheju Island in Summer-)

  • YANG Han-Soeb;KIM Seong-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.24 no.3
    • /
    • pp.177-184
    • /
    • 1991
  • We have investigated geographical distribution and physico-chemical properties of water masses or water types at mid-bottom depth in the neighbouring sea of Cheju Island in August 1986. In 50m layer the Yellow Sea Bottom Cold Water(YSBCW) below $12^{\circ}C$ was observed in the northwestern area of Cheju Island, while the Tsushima Warm Water(TWW) with relatively high temperature$(>16^{\circ}C)$ and salinity more than 34.0 in its southeastern area extended as far as the coast of about 15km. Also, 50m layer at the outside stations of its southwestern area indicated relatively cold water temperature$(11-30^{\circ}C)$, probably due to southward transport of the Yellow Sea Bottom Cold Water(YSBCW . The Yellow Sea Warm Water(YSWW), the mixed water of the YSBCW and the TWW, ranged $13^{\circ}C$ to $16^{\circ}C$ in water temperature and was appeared mainly in the coastal and intermediate area of Cheju Island. And the relatively cold water in the southwestern area and the Tsushima Warm Water were more extensively distributed in 50m layer than the deeper layer. Horizontal distributions of nitrate and phosphate showed a pattern similar to that of water temperature. As it were, the Yellow Sea Bottom Cold Water had the highest concentration of nutrients, while southwestern outside stations had the lowest nutrient contents. Especially, the concentration of nitrate in the latter was remarkably low compared with the value at the other stations. It may be attributed to intensive vertical mixing by collision of the northward driven Tn with the southward driven YSBCW. Also, it was particular that the Tsushima Warm Water indicated relatively high silicate content corresponding to that of the Yellow Sea Bottom Cold Water. Based on the data of $\Delta Si/\Delta P$ ratio, it seems that the mid-bottom waters in this study area are younger than the surface or intermediate water in the Korean East Sea.

  • PDF

The Variation of Natural Population of Pinus densiflora S. et Z. in Korea (IX) -Needle and Wood Characteristics of Six Populations- (소나무천연집단(天然集團)의 변이(變異)에 관(關)한 연구(硏究)(IX) -광주(廣州), 제천(堤川), 보은(報恩), 무주(茂朱), 구례(求禮), 제주집단(濟州集團)의 침엽(針葉) 및 재질형질(材質形質)-)

  • Yim, Kyong Bin;Lee, Kyong Jae
    • Journal of Korean Society of Forest Science
    • /
    • v.44 no.1
    • /
    • pp.1-25
    • /
    • 1979
  • Six natural populations of Pinus densiflora S. et Z. as shown in the location map (Flg 1) were studied during 1978. The numerial pouplation codes, 13 to 18. The results of populations 1 to 12 were reported in previous papers. Following the study methods described before, 20 trees were sampled from each population and morpological characteristics such as stem forms, branching habit needle and wood properties investigated. The results are summerized as follows; 1. The mean stand ages were ranged from 36 to 97 of years. The growth performances of trees of population 14. 15 and 18 was similar, but 13, 16, and 17 seemed to be inferior more or less. 2. The ratios of clear bole length were 0.70 in population 18 as the highest but 0.28 for population 16 as the lowest. 3. The population 17 was considered to be a stand of the coarser branching habit having the crown index (The maximum crown diameter/the crown height) 158 though the branching angles were almost horizontal. 4. The differences were observed in the clear bole length ratios and crown-indices between population as shown In Fig. 3 and 4. 5. As to the serration density, number of stomata row and resin duct; the significant differences exist between individual trees within population and also between populations. 6. Population 18 shown resin duct index 0.119 as the maximum. 7. The patterns of diameter growth, based on the width of 10-year-ring segment unit(for example, the 1st segment denotes the with between pith center and 10th year ring and the 2nd one is from 11th to 20th ring and so on.), were alike among populations as shown in Fig 9. 8. Significant differences between population in mean summer wood percentage as well as in wood specific gravity was observed. The values of wood specific gravity were increased with the increase of ages in population 14, 18 however vice versa in population 13, 15, and 17. 9. The fiber length was mereased with the increased of age but no differences between populations as shown in Fig. 12.

  • PDF

Classification of Seismic Stations Based on the Simultaneous Inversion Result of the Ground-motion Model Parameters (지진동모델 파라미터 동시역산을 이용한 지진관측소 분류)

  • Yun, Kwan-Hee;Suh, Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.3
    • /
    • pp.183-190
    • /
    • 2007
  • The site effects of seismic stations were evaluated by conducting a simultaneous inversion of the stochastic point-source ground-motion model (STGM model; Boore, 2003) parameters based on the accumulated dataset of horizontal shear-wave Fourier spectra. A model parameter $K_0$ and frequency-dependent site amplification function A(f) were used to express the site effects. Once after a H/V ratio of the Fourier spectra was used as an initial estimate of A(f) for the inversion, the final A(f) which is considered to be the result of combined effect of the crustal amplification and loca lsite effects was calculated by averaging the log residuals at the site from the inversion and adding the mean log residual to the H/V ratio. The seismic stations were classified into five classes according to $logA_{1-10}^{max}$(f), the maximum level of the site amplification function in the range of 1 Hz < f < 10 Hz, i.e., A: $logA_{1-10}^{max}$(f) < 0.2, B: 0.2 $\leq$ $logA_{1-10}^{max}$(f) < 0.4, C: 0.4 $\leq$ $logA_{1-10}^{max}$(f) < 0.6, D: 0.6 $\leq$ $logA_{1-10}^{max}$(f) < 0.8, E: 0.8 $\leq$ $logA_{1-10}^{max}$(f). Implication of the classified result was supported by observing a shift of the dominant frequency of average A(f) for each classified stations as the class changes. Change of site classes after moving seismic stations to a better site condition was successfully described by the result of the station classification. In addition, the observed PGA (Peak Ground Acceleration)-values for two recent moderate earthquakes were well classified according to the proposed station classes.

Micro Feeding Site Preference of Wintering Cranes by Topography and Vegetation in Cheorwon Basin, Korea (철원지역에서 월동하는 두루미류의 지형과 식생에 의한 미소 취식지 선호성)

  • Yoo, Seung-Hwa;Kim, In-Kyu;Lee, Han-Soo;Lee, Ki-Sup
    • Korean Journal of Environment and Ecology
    • /
    • v.23 no.5
    • /
    • pp.418-430
    • /
    • 2009
  • The main purpose of this study is to investigate the relationship between the topography of land and vegetation and the preferred habitat of wintering cranes. Investigations were conducted twelve times in Cheorwon basin, South Korea, during two wintering seasons (12/2005 - 2/2006; 1/2007 - 2/2007). The density of rice grain in the middle of rice paddies was higher than that of the areas along the edge of rice paddies. However it was observed that red-naped cranes preferred to feed along the edges of rice paddies rather than to feed in the middle of the paddies. White-naped cranes, on the other hand, Preferred to feed in the middle of paddies. To be more specific, red-crowned cranes preferred feeding sites such as levees of the paddies or the areas where the level of the rice beds was comparatively more elevated. But the preference of the white-naped cranes turned out to be just the opposite. Another finding was that both red-naped cranes and white-naped cranes preferred concealed areas for their feeding site, and the frequency rate of their feeding in concealed areas has little to do with weather factors. This finding contradicts a widely accepted view that cranes prefer open spaces for their feeding site. Besides, red-crowned cranes, compared with white-naped cranes, preferred to feed in more concealed areas. The frequency rate of feeding in both concealed areas and non-concealed areas had little to do with the size of feeding flocks. There was no difference between a flock of fewer than five cranes and a flock of more than five cranes in terms of frequency rate of their feeding. In conclusion, the result of these investigations indicate that red-naped cranes comparatively prefer concealed areas for their feeding site, and white-naped cranes are less prone to them, and there is no direct connection between their preference of feeding site or frequency and the size of their flock. This is presumed to be the characteristics unique to their individual species.

Morphological Adaptation of Zostera marina L. to Ocean Currents in Korea (한국산 거머리말(Zostera marina L.)의 해류에 대한 형태적 적응)

  • Lim, Dong-Ok;Yun, Jang-Tak;Han, Kyung-Shik
    • Korean Journal of Environment and Ecology
    • /
    • v.23 no.5
    • /
    • pp.431-438
    • /
    • 2009
  • The main purpose of this research is to prepare and provide basic materials for the propagational strategy of eelgrass by investigating on the morphological adaptation of Korean Zostera marina to ocean currents. An eelgrass plant mainly consists of rhizome, leaf sheath, leaves and roots. The rhizome is the horizontal stem of the plant that serves as the backbone from which the leaves and roots emerge. The leaf sheath is the bundle at the base of the leaves that holds the leaves together, protecting the meristem, the primary growth point of the shoot. Leaves originate from a meristem which is protected by a sheath at the actively growing end of the rhizome. As the shoot grows, the rhizome elongates, moving across or within the sediment, forming roots as it progresses. The aggregated leaves from the leaf sheath are found to have two cell layers on one side and multiple layers of airy tissues called aerenchyma on the other. The aerenchyma tissues are developed in multi-layered cell structures surrounding the veins which are formed in the leaf sheath. Generative shoots are made of rhizomes, which are circular or ovoidal, stem, and spathe and spadix. The transverse section of rhizome and the stem and central floral axis is found to be circular, ovoid and in the shape of convex respectively, and the vascular bundle, which is a part of transport system, has one large tube in the center and two small tubes on both sides. The layers of collenchyma cells numbered from 12 to 15 in the stem, and from 7 to 12 in the rhizome. The seed coat is composed of sclereids, small bundles of sclerenchyma tissues, which prevent the influx of sea water from the outside and help endure the environmental stress. In conclusion, alternative multi-layer structure in circular, convex type aggregated leaf base are interpreted to morphological adaption as doing tolerable elastic structure through movement of seawater. The generative shoots develop long slim stem and branches in circular or ovoidal shapes to minimize the adverse impacts of sea current, which can be interpreted as the plant's morphological adaptation to its environment.

Stress distribution following face mask application using different finite element models according to Hounsfield unit values in CT images (CT상의 HU 수치에 따른 상악골 전방견인 효과의 유한요소 분석)

  • Chung, Dong-Hwa
    • The korean journal of orthodontics
    • /
    • v.36 no.6
    • /
    • pp.412-421
    • /
    • 2006
  • Objective: The result of finite element analysis depends on material properties, structural expression, density of element, and boundar or loading conditions. To represent proper elastic behavior, a finite element model was made using Hounsfield unit (HU) values in CT images. Methods: A 13 year 6 month old male was used as the subject. A 3 dimensional visualizing program, Mimics, was used to build a 3D object from the DICOM file which was acquired from the CT images. Model 1 was established by giving 24 material properties according to HU. Model 2 was constructed by the conventional method which provides 2 material properties. Protraction force of 500g was applied at a 45 degree downward angle from Frankfort horizontal (FH) plane. Results: Model 1 showed a more flexible response on the first premolar region which had more forward and downward movement of the maxillary anterior segment. Maxilla was bent on the sagittal plane and frontal plane. Model 2 revealed less movement in all directions. It moved downward on the anterior part and upward on the posterior part, which is clockwise rotation of the maxilla. Conclusion: These results signify that different outcomes of finite element analysis can occur according to the given material properties and it is recommended to use HU values for more accurate results.

THREE DIMENSIONAL ANALYSIS OF MAXILLOFACIAL STRUCTURE BY FRONTAL AND LATERAL CEPHALOGRAM (두부 방사선 규격사진을 이용한 악안면 구조의 3차원적 분석법)

  • Kwon, Kui-Young;Lee, Sang-Han;Kwon, Tae-Geon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.2
    • /
    • pp.174-188
    • /
    • 1999
  • The purpose of this study is to evaluate the precision and accuracy of a three dimensional cephalogram constructed by using the frontal and lateral cephalogram of twelve human dry skulls. After achieving the three dimensional image reconstruction program, we tried to apply this program to two dentofacial deformity patients. 1. Conventional nasion relator in cephalostat was used to reproduce the same head position for the same dry skull. The mean difference of the three dimensional cephalogram for the same dry skull was $0.34{\pm}0.33mm$. Closeness of repeated measures to each skull reveals the precision of this method for the three dimensional cephalogram. 2. Concerning the accuracy, the mean difference between the three dimensional reconstruction data and actual lineal measurements was $1.47{\pm}1.45mm$ and the mean magnification ratio was $100.24{\pm}4.68%$. This Diffrerence is attributed mainly to the ill defined cephalometric landmarks, not to the positional change of the dry skull. 3. Cephalometric measurement of lateral and frontal radiographs had no consecutive magnification ratio because of the different focus-object distance. The mean difference between the frontal and lateral cephalogram to the actual lineal measurements was $4.72{\pm}2.01mm$ and $-5.22{\pm}3.36mm$. Vertical measurements were slightly more accurate than horizontal measurements. 4. Applying to the actual patient analysis, it is recommendable to use this program for analyzing the asymmetry or spatial change after operation. The orthodontic bracket would be a favorable cephalometric landmark for constructing the three dimensional images.

  • PDF

Roots Growth Characteristics of Zelkova serrata Makino. after Replanting in the Reclaimed Land from the Sea - On the Root Structure and Spatial Distribution of Fine Root Phytomass - (임해매립지의 느티나무 식재 이후 뿌리 생장특성 -뿌리구조 및 세근의 공간적 분포를 중심으로-)

  • Kim, Do-Gyun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.5
    • /
    • pp.46-55
    • /
    • 2007
  • This study was carried out to analyze both the root structure and the fine root phytomass of the vertical and horizontal distribution of Zelkova serrata Makino. which was transplanted in the reclaimed land from the sea in Gwangyang, Jeonnam, South Korea. The base ground was reclaimed land from the sea. $Z_1$ of the planting ground was filled to a $100{\sim}150cm$ thickness with the improved soil instead of the reclaimed soil from the sea, $Z_2$ of the planting ground was covered to a $20{\sim}30cm$ thickness with the improved soil and $Z_3$ of the planting ground was mounded to 120cm thickness with the improved soil on the reclaimed land from the sea. In addition, $Z_4,\;Z_5\;and\;Z_6$ of the planting grounds were at the large-sized mound on the reclaimed land from the sea. $Z_4$ of the planting ground was located at the lowest level, $Z_5$ planting ground was located at the slope and $Z_6$ planting ground was located at the top of the large-sized mound. The large-sized mounds contain 3 layers, the base layer was reclaimed land from the sea and the second layer was mounded to a $200{\sim}300cm$ thickness with the desalinized soil from the sea on the base layers and the finally layers were mounded to a $80{\sim}120cm$ thickness with improved soil on the second layer. The planting grounds $Z_3,\;Z_4,\;Z_5\;and\;Z_6$ developed roots such as tap roots, lateral roots and heart roots. However, in $Z_1\;and\;Z_2$ roots development were inhibited. The fine-root phytomass of the 6 planting ground types was as follows: $113.5g\;DM/m^2$ for $Z_5$, $105.5g\;DM/m^2$ for $Z_4$, $88.3g\;DM/m^2$ for $Z_3$, $81.0g\;DM/m^2$ for $Z_6$, $73.0g\;DM/m^2$ for $Z_2$, $43.3g\;DM/m^2$ for $Z_1$. The vertical distribution of the fine root phytomass decreased from the upper to the deeper soil profiles in the 6 mound types. The fine root phytomass was $43.3{\sim}71.8%$ in a $0{\sim}20cm$ thickness of soil layer and it decreased according to the distance from the nearest trees. The root growth in the improved soil was better than in the reclaimed soil from the sea. However, root growth decreased more in the disturbed soils even though the planting grounds contained the improved soils. The retarded development of roots and the spatial distribution patterns of the fine root phytomass were closely connected to the reclaimed soil from the sea. In the disturbed soil, the soil hardness and alkalic cation($Na^+,\;K^+,\;Ca^{2+},\;Mg^{2+}$). were high and the soil water was lacking. We suggest that the construction of planting grounds and the improvement of bad soil are necessary for the proper and effective growth of landscaping plants.

Strategies about Optimal Measurement Matrix of Environment Factors Inside Plastic Greenhouse (플라스틱온실 내부 환경 인자 다중센서 설치 위치 최적화 전략)

  • Lee, JungKyu;Kang, DongHyun;Oh, SangHoon;Lee, DongHoon
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.161-170
    • /
    • 2020
  • There is systematic spatial variations in environmental properties due to sensitive reaction to external conditions at plastic greenhouse occupied 99.2% of domestic agricultural facilities. In order to construct 3 dimensional distribution of temperature, relative humidity, CO2 and illuminance, measurement matrix as 3 by 3 by 5 in direction of width, height and length, respectively, dividing indoor space of greenhouse was designed and tested at experimental site. Linear regression analysis was conducted to evaluate optimal estimation method in terms with horizontal and vertical variations. Even though sole measurement point for temperature and relative humidity could be feasible to assess indoor condition, multiple measurement matrix is inevitably required to improve spatial precision at certain time domain such as period of sunrise and sunset. In case with CO2, multiple measurement matrix could not successfully improve the spatial predictability during a whole experimental period. In case with illuminance, prediction performance was getting smaller after a time period of sunrise due to systematic interference such as indoor structure. Thus, multiple sensing methodology was proposed in direction of length at higher height than growing bed, which could compensate estimation error in spatial domain. Appropriate measurement matrix could be constructed considering the transition of stability in indoor environmental properties due to external variations. As a result, optimal measurement matrix should be carefully designed considering flexibility of construction relevant with the type of property, indoor structure, the purpose of crop and the period of growth. For an instance, partial cooling and heating system to save a consumption of energy supplement could be successfully accomplished by the deployment of multiple measurement matrix.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.