• Title/Summary/Keyword: hollow ratio

Search Result 316, Processing Time 0.024 seconds

Measurement of the Refractive Index of a Mixed Polymer by a Prism Spectrometer and its Application (프리즘 분광계를 이용한 혼합 폴리머의 굴절률 측정과 응용)

  • Kim, Ji-Young;Ju, Young-Gu
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.5
    • /
    • pp.221-228
    • /
    • 2017
  • We measured the refractive index of a mixed polymer (NOA61, NOA84) in the liquid and solid states. First we made a hollow prism and filled it with UV (ultraviolet) epoxy. Measurement of the apex angle and the minimum-deviation angle gave the refractive index of the liquid polymer. To measure the refractive index of the solid polymer, an additional structure was included in the hollow prism, and the UV epoxy filling in the hollow prism was hardened. In both cases of liquid and solid polymers, the refractive index of the mixed polymer turned out to be proportional to the mix ratio. These results provide a method to vary the focal length of a double stacked cylindrical microlens array using UV epoxy.

Analytical and experimental investigations on the performance of tuned liquid column ball damper considering a hollow ball

  • Shah, Mati Ullah;Usman, Muhammad;Kim, In-Ho;Dawood, Sania
    • Structural Engineering and Mechanics
    • /
    • v.83 no.5
    • /
    • pp.655-669
    • /
    • 2022
  • Passive vibration control devices like tuned liquid column dampers (TLCD) not only significantly reduce buildings' vibrations but also can serve as a water storage facility. The recently introduced modified form of TLCD known as tuned liquid column ball damper (TLCBD) suppressed external vibration efficiently compared to traditional TLCD. For excellent performance, the mass ratio of TLCBD should be in the range of 5% to 7%, which does not include the mass of the ball. This additional mass of the ball increases the overall structure mass. Therefore, in this paper, an effort is made to reduce the mass of TLCBD. For this purpose, a new modified version of TLCBD known as tuned liquid column hollow ball damper (TLCHBD) is proposed. The existing mathematical modeling of TLCBD is used for this new damper by updating the numerical values of the mass and mass moment of the ball. Analytically the optimal design parameters are obtained. Numerically the TLCHBD is investigated with a single degree of freedom structure under harmonic and seismic loadings. It is found that TLCHBD performance is similar to TLCBD in both loadings' cases. To validate the numerical results, an experimental study is conducted. The mass of the ball of TLCHBD is reduced by 50% compared to the ball of TLCBD. Both the arrangements are studied with a multi-degree of freedom structure under harmonic and seismic loadings using a shake table. The results of the experimental study confirm the numerical findings. It is found that the performance behavior of both the dampers is almost similar under harmonic and seismic loadings. In short, the TLCHBD is lighter in weight than TLCBD but has a similar vibration suppression ability.

Dynamics of the system consisting of the hollow cylinder and surrounding infinite elastic medium under action an oscillating moving ring load on the interior of the cylinder

  • Akbarov, Surkay D.;Mehdiyev, Mahir A.
    • Coupled systems mechanics
    • /
    • v.7 no.5
    • /
    • pp.525-554
    • /
    • 2018
  • The paper deals with the study of the dynamics of the oscillating moving ring load acting in the interior of the hollow circular cylinder surrounded by an elastic medium. The axisymmetric loading case is considered and the study is made by employing the exact equations and relations of linear elastodynamics. The focus is on the influence of the oscillation of the moving load and the problem parameters such as the cylinder's thickness/radius ratio on the critical velocities. At the same time, the dependence between the interface stresses and load moving velocity under various frequencies of this load, as well as the frequency response of the mentioned stresses under various load velocity are investigated. In particular, it is established that oscillation of the moving load can cause the values of the critical velocity to decrease significantly and at the same time the oscillation of the moving load can lead to parametric resonance. It is also established that the critical velocity decreases with decreasing of the cylinder's thickness/radiusratio.

A Study on the Stress Analysis for Design of Composite Material Shafts of Small Boats (소형 선박용 복합재료 축 설계를 위한 음력해석에 관한 연구)

  • Kim, Yun-Hae;Im, Cheol-Mun;Bae, Chang-Won;Wang, Ji-Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.2
    • /
    • pp.308-313
    • /
    • 2002
  • It is known that the composite material shafts using on small boats have various advantages comparing to forged steel shafts, fur examples, specific strength, fatigue strength, corrosion, etc. The analysis of the stresses and strains in the composite material shafts made by filament winding method is presented in this paper. The classical laminated plate theory is applied on the patch cut from the composite material hollow shafts. It is verified that the composite material hollow shafts of diameter 40 mm is the most optimum when the ratio of the inner diameter to the outer is 0.4 and winding angle is 45$^{\circ}$. It is also proven that the shear strain does not change seriously between 30$^{\circ}$and 60$^{\circ}$of winding angles. It is dangerous when the winding angle is over 75$^{\circ}$because the values of shear strain and stress produced on the shaft are too high so it must be avoided to wind the filament by the angle over 75$^{\circ}$.

Damping identification procedure for linear systems: mixed numerical-experimental approach

  • El-Anwar, Hazem Hossam;Serror, Mohammed Hassanien;Sayed, Hesham Sobhy
    • Earthquakes and Structures
    • /
    • v.4 no.2
    • /
    • pp.203-217
    • /
    • 2013
  • In recent decades, it has been realized that increasing the lateral stiffness of structure subjected to lateral loads is not the only parameter enhancing safety or reducing damage. Factors such as ductility and damping govern the structural response due to lateral loads. Despite the significant contribution of damping in resisting lateral loads, especially at resonance, there is no accurate mathematical representation for it. The main objective of this study is to develop a damping identification procedure for linear systems based on a mixed numerical-experimental approach, assuming viscous damping. The proposed procedure has been applied to a laboratory experiment associated with a numerical model, where a hollow rectangular steel cantilever column, having three lumped masses, has been fixed on a shaking table subjected to different exciting waves. The modal damping ratio has been identified; in addition, the effect of adding filling material to the hollow specimen has been studied in relation to damping enhancement. The results have revealed that the numerically computed response based on the identified damping is in a good fitting with the measured response. Moreover, the filling material has a significant effect in increasing the modal damping.

Determination of limiting temperatures for H-section and hollow section columns

  • Kwon, In-Kyu;Kwon, Young-Bong
    • Steel and Composite Structures
    • /
    • v.13 no.4
    • /
    • pp.309-325
    • /
    • 2012
  • The risk of progressive collapse in steel framed buildings under fire conditions is gradually rising due to the increasing use of combustible materials. The fire resistance of such steel framed buildings is evaluated by fire tests. Recently, the application of performance based fire engineering makes it easier to evaluate the fire resistance owing to various engineering techniques and fire science. The fire resistance of steel structural members can be evaluated by the comparison of the limiting temperatures and maximum temperatures of structural steel members. The limiting temperature is derived at the moment that the failure of structural member results from the rise in temperature and the maximum temperature is calculated by using a heat transfer analysis. To obtain the limiting temperatures for structural steel of grades SS400 and SM490 in Korea, tensile strength tests of coupons at high temperature were conducted. The limiting temperatures obtained by the tensile coupon tests were compared with the limiting temperatures reported in the literature and the results of column fire tests under four types of loading with different load ratios. Simple limiting temperature formulas for SS400 and SM490 steel based on the fire tests of the tensile coupons are proposed. The limiting temperature predictions using the proposed formulas were proven to be conservative in comparison with those obtained from H-section and hollow section column fire tests.

Synthesis of Molecularly Imprinted Polymers for Chiral (S)-Ibuprofen and Their Molecular Recognition Mechanism (키랄(S)-이부푸로펜 함유 고분자의 합성과 제조된 고분자의 분자 인식 메카니즘)

  • Huangfu, Fengyun;Wang, Bing;Sun, Yan
    • Polymer(Korea)
    • /
    • v.37 no.3
    • /
    • pp.288-293
    • /
    • 2013
  • A group of molecularly imprinted polymers (MIPs) with specific recognition for chiral (S)-ibuprofen were successfully prepared based on hydrogen bonds, utilizing ${\alpha}$-methacrylic acid as a functional monomer. The IR analysis of MIPs showed that the blue- and red-shifted hydrogen bonds were formed between templates and functional monomers in the process of self-assembly imprinting and re-recognition, respectively. According to UV-Vis analysis, we found that the ratio of host-guest complexes between template molecule and functional monomer was 1:1. The effect of cross-linker's quantity on the polymerization was studied by transmission electron microscope (TEM). The adsorption selectivity experiments indicated that MIPs exhibited higher selectivity to (S)-ibuprofen than those to ketoprofen and (R)-ibuprofen, (S)-ibuprofen's structural analogs.

Membrane Concentrate Thickening by Hollow-fiber Microfilter in Drinkin Water Treatment Processes

  • 이병호
    • Membrane Journal
    • /
    • v.1 no.1
    • /
    • pp.100-100
    • /
    • 1991
  • A novel system to thicken the concentrated colloidal solution from membrane water treat-ment processes was developed. A hollow-fiber microfilter(hydrophilic polyethylene nominal pore size 0.1 μm total surface area 0.42 m2) was installed in an acrylic housing that has an aeration port 5 cm below the membrane and a clarifier in the bottom. The concentrate was uniformly supplied from the top of the housing. Bacuum filtration caused downward flow of concentrate and as a result thickening interface. The addition of poly-aluminum chloride (PAC) resulted in rapid increase of trans-membrane pressure (TMP) and in no improvement of the filtered water turbidity and thickening process. Two types of con-centrate and concentrate turbidity had little effect on the increase of TMP and concentrate thickening. It was observed that for the same height of membrane housing membrane surface area to housing volume (A/V) ratio had significant effect on the increase of TMP. When the housing volume was increased ten times the increasing rate of TMP was three times faster as compared to the original housing. A hydraulic model successfully simulated the formation and sedimentation of thickening interface.

Field Application of the Membrane System for the Recovery of VOCs from the Automobile Painting Process (도장공정 휘발성 유기화합물 회수를 위한 분리막 시스템의 현장 적용성 평가)

  • Choi, Whee Moon;Cho, Soon Haing;Kim, Soon Tae;Lee, Chung Seop;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.23 no.2
    • /
    • pp.129-135
    • /
    • 2013
  • To recover of volatile organic compounds (VOCs) induced by painting process, we prepared separation system using hollow fiber membrane modules and evaluated the recovery performance of VOCs with different feed pressure and operating time. Concentration of volatile organic compound in permeate through the membrane increased with increasing operating time and pressure. Performance of the membrane for removing the VOCs when we applied 2-stage process showed better performance than that of single stage process.

A Study on the Potable Water Purification System with Pre-Ozone and Ultra Filtration Membrane of Hollow Fiber Type (전오존과 중공사형 한외여과막을 이용한 간이정수처리시스템에 관한 연구)

  • Kim, Min-Kuk;Chun, Yang-Kun
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.196-204
    • /
    • 2005
  • The objective of this study is to evaluate the possibility to apply pre-ozone and membrane system for drinking water. This system is improved in fouling control by pre-ozone system. It is composed of ultrafiltration hollow fiber type membrane and ozone reactor. The result of this study is that the flux is increased about 10.7% and decreased in TMP by the pre-ozone. Also, backwashing pressure decreased about 18%. The optimum concentration of residual ozone is 0.3~0.5 ppm. During the period, the recovery ratio of this system was turned out to be 90% as the flowrate of effluent is $67.1m^3/day$. When the TMP and backwashing pressure was $0.85kg/cm^2$ and $1.10kg/cm^2$, this system was stable without sudden fouling. Finally, the quality of effluent is satisfied the guidelines for potable water quality such as turbidity, color, E.coli, Mn, Al, Fe and so on.