• 제목/요약/키워드: hollow beam

검색결과 141건 처리시간 0.023초

Behavior and calculation on concrete-filled steel CHS (Circular Hollow Section) beam-columns

  • Han, Lin-Hai;Yao, Guo-Huang;Zhao, Xiao-Ling
    • Steel and Composite Structures
    • /
    • 제4권3호
    • /
    • pp.169-188
    • /
    • 2004
  • A mechanics model is developed in this paper for concrete-filled steel CHS (circular hollow section) beam-columns. A unified theory is described where a confinement factor (${\xi}$) is introduced to describe the composite action between the steel tube and the filled concrete. The predicted load versus deformation relationship is in good agreement with test results. The theoretical model was used to investigate the influence of important parameters that determine the ultimate strength of concrete-filled steel CHS beam-columns. The parametric and experimental studies provide information for the development of formulas for the calculation of the ultimate strength of the composite beam-columns. Comparisons are made with predicted beam-columns strengths using the existing codes, such as LRFD-AISC-1999, AIJ-1997, BS5400-1979 and EC4-1994.

Behaviour of cold-formed steel concrete infilled RHS connections and frames

  • Angeline Prabhavathy, R.;Samuel Knight, G.M.
    • Steel and Composite Structures
    • /
    • 제6권1호
    • /
    • pp.71-85
    • /
    • 2006
  • This paper presents the results of a series of tests carried out on cold-formed steel rectangular hollow and concrete infilled beam to column connections and frames. A stub column was chosen such that overall buckling does not influence the connection behaviour. The beam chosen was a short-span cantilever with a concentrated load applied at the free end. The beam was connected to the columns along the strong and weak axes of columns and these connections were tested to failure. Twelve experiments were conducted on cold-formed steel direct welded tubular beam to column connections and twelve experiments on connections with concrete infilled column subjected to monotonic loading. In all the experiments conducted, the stiffness of the connection, the ductility characteristics and the moment rotation behaviour were studied. The dominant mode of failure in hollow section connections was chord face yielding and not weld failure. Provision of concrete infill increases the stiffness and the ultimate moment carrying capacity substantially, irrespective of the axis of loading of the column. Weld failure and bearing failure due to transverse compression occurred in connections with concrete infilled columns. Six single-bay two storied frames both with and without concrete infill, and columns loaded along the major and minor axes were tested to failure. Concentrated load was applied at the midspan of first floor beam. The change in behaviour of the frame due to provision of infill in the column and in the entire frame was compared with hollow frames. Failure of the weld at the junction of the beam occurred for frames with infilled columns. Design expressions are suggested for the yielding of the column face in hollow sections and bearing failure in infilled columns which closely predicted the experimental failure loads.

속 빈 레이저 빔을 이용한 원자 가이드 (Hollow Beam Atom Tunnel)

  • 송연호
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2000년도 제11회 정기총회 및 00년 동계학술발표회 논문집
    • /
    • pp.130-131
    • /
    • 2000
  • One of the more promising proposals for guiding and focusing neutral atoms involves dark hollow laser beams. When the frequency of the laser is detuned to the blue of resonance, the dipole force the atoms feel in the light confines them to the dark core where the atoms can be transported with minimal interaction with the light. The ability of the all-light atom guides to transport large number of ultracold atoms for long distances without physical walls leads to the possibility of a versatile tool for atom lithography, atom interferometry, atomic spectroscopy as well as for transporting and manipulating Bose-Einstein condensates. Furthermore since the atoms transported in all-light atom guides do not come into contact with matter, they can in principle be used to transport antimatter as well. The ability to vary the core size of the hollow beam makes the all-light atom guide potentially useful for focusing neutral atoms. The atoms could be focused as tight as the core size of the hollow beam at its waist. This new focusing scheme, called the atom funnel, would not show spherical and chromatic aberrations that conventional harmonic focusing suffers from. (omitted)

  • PDF

곡선형 RC 중공 슬래브교의 안전성 평가 사례 연구 (A Study on the Safety Assessment of Curved Hollow RC Slab Bridge Structures)

  • 채원규;조병완;김광일
    • 한국안전학회지
    • /
    • 제21권6호
    • /
    • pp.96-100
    • /
    • 2006
  • In this thesis, the crack investigation, the damage investigation, the drawing check, and the structural analysis were performed on a curved hollow RC(reinforced concrete) slab bridge structure to assess the structural safety of that. From the crack investigation result, main reason of crack occurrence is guessed with travelling of the large truck. Therefore reinforcement of slab structure is necessary by using the steel plate. When structural analysis, the straight beam model, the curved beam model, and the curved plate model is used. From the results of structural analysis for curved hollow RC slab bridge, the maximum bending moment and the maximum shear force was not a difference in each models. But the vertical displacement of mid span using the curved beam model was greater than that using the other models.

스테인리스 각형강관기둥의 최대내력 (The Maximum Strength of Stainless Steel Rectangular Hollow Section Columns and Beam-Columns)

  • 이명재;김희동
    • 한국강구조학회 논문집
    • /
    • 제17권1호통권74호
    • /
    • pp.73-82
    • /
    • 2005
  • 본 논문은 스테인리스강이 건축구조용으로 이용될 때 중심압축재와 기둥의 최대내력을 수치해석으로 조사한 것이다. STS304의 소재인장시험결과로부터 응력-변형도 관계를 모델화하여 최대내력에 미치는 영향을 조사하였으며 강구조 한계상태설계기준식과의 비교를 시도하였다. 스테인리스강을 건축구조용으로 사용하기 위해서는 별도의 설계기준식이 필요하다는 점이 확인되었다.

이온 플레이팅용 장수명 플라즈마 건 장치의 개발 (Development of a Plasma Gun System for Ion Plating with Long Lifetime)

  • 최영욱
    • 전기학회논문지
    • /
    • 제57권1호
    • /
    • pp.78-81
    • /
    • 2008
  • A hollow cathode which has extremely stable discharge characteristic has been developed. This is composed of the two separated lanthanum hexaboride(LaB6) of a disk type in the tube as the electron emitters. The way of design is of great advantage to extend the surface discharge area of the LaB6, which is also useful for optimal fixing of the LaB6. The hollow cathode is capable of producing 30 kW(100 V, 300 A) of power continuously. Because the generated plasma beam with the high temperature(above $3000^{\circ}C$) from the hollow cathode passes through the center hole of the two intermediate electrodes, it is designed with the high temperature material of the tungsten and the suitable structure of the water cooling. The combinations of the hollow cathode and the two intermediate electrodes are practically useful for the ion plating plasma beam source.

매입형 합성보의 휨 성능 평가 -속 빈 프리캐스트 콘크리트 슬래브와 비대칭 H형강 철골보- (Flexural Capacity of Encased Composite Beam with Hollow Core PC Slabs)

  • 허병욱;배규웅;문태섭
    • 한국강구조학회 논문집
    • /
    • 제16권5호통권72호
    • /
    • pp.587-598
    • /
    • 2004
  • 본 연구에서는 합성보의 전체 춤을 절감할 수 있도록 속 빈 프리캐스트 콘크리트 슬래브를 철골보의 춤내에 삽입하여 일체화함으로써 철골조 고층건물에서 층고를 최소화 할 수 있는 이른바 "슬림플로어"공법에 대한 연구를 수행하였다. 본 연구는 콘크리트에 매입된 비대칭 철골보를 가지는 불완전 합성 슬림플로어 시스템의 휨 거동에 관한 것이다. 총 10개의 실대형 실험체를 철골보 춤, 속빈 프리캐스트 콘크리트 슬래브 춤, 슬래브 유효폭, 및 콘크리트 슬래브의 지지방식 별로 제작하여 실험을 수행하였다. 실험결과, 매입형 합성보의 경우, 별도의 전단연결재를 설치하지 않아도 자체가 가지고 있는 기계적 화학적 부착응력으로 인해 완전합성보에 비해서 0.48~0.98의 전단합성비를 나타내었다.

Rehabilitation of corroded circular hollow sectional steel beam by CFRP patch

  • Setvati, Mahdi Razavi;Mustaffa, Zahiraniza
    • Steel and Composite Structures
    • /
    • 제32권1호
    • /
    • pp.127-139
    • /
    • 2019
  • Bridges, offshore oil platforms and other infrastructures usually require at some point in their service life rehabilitation for reasons such as aging and corrosion. This study explores the application of adhesively bonded CFRP patches in repair of corroded circular hollow sectional (CHS) steel beams. An experimental program involving three-point bending tests was conducted on intact, corroded, and repaired CHS beams. Meso-scale finite element (FE) models of the tested beams were developed and validated by the experimental results. A parametric study using the validated FE models was performed to examine the effects of different CFRP patch parameters, including patch dimensions, number of plies and stacking sequence, on efficiency of the repair system. Results indicates that the corrosion reduced elastic stiffness and flexural strength of the undamaged beam by 8.9 and 15.1%, respectively, and composite repair recovered 10.7 and 18.9% of those, respectively, compared to undamaged beam. These findings demonstrated the ability of CFRP patch repair to restore full bending capacity of the corroded CHS steel beam. The parametric study revealed that strength and stiffness of the repaired CHS beam can be enhanced by changing the fiber orientations of wet composite patch without increasing the quantity of repair materials.

철근콘크리트 속빈 단면 보의 곡률연성지수 특성 (The Characteristics of Curvature Ductility Factor of Reinforced Concrete Hollow Section Beams)

  • 이형준
    • 한국산학기술학회논문지
    • /
    • 제14권12호
    • /
    • pp.6542-6549
    • /
    • 2013
  • 콘크리트 구조물이 대형화됨에 따라 고교각, 장지간의 보 등 부재가 장대화되고 있으며, 장지간의 철근콘크리트 부재에서는 자중을 줄이고 강성을 증가시키기 위해 속빈 단면을 사용하는 것이 증가하는 추세이다. 본 연구에서는 철근콘크리트 속빈 단면 보의 모멘트-곡률 관계를 해석적 방법으로 구하여 속빈 부분의 크기, 상부플랜지와 복부의 철근 배치조건이 부재의 휨거동 및 곡률연성지수에 미치는 영향을 분석하였다. 속빈 부분의 크기($b_i/b_o$ 또는 $h_i/h_o$)가 0.5이하일 때에는 곡률연성지수가 일정하게 유지되며, 0.7이상이 되면 곡률연성지수가 급격히 감소하였다. 또한, 복부에 철근을 배치하면 곡률연성지수가 감소하며 단철근 보에서와 같은 수준의 연성지수를 얻기 위해서는 복부에 배치한 철근과 같은 양을 상부플랜지에 배치해야 하는 것으로 나타났다.

Rehabilitation of notched circular hollow sectional steel beam using CFRP patch

  • Setvati, Mahdi Razavi;Mustaffa, Zahiraniza
    • Steel and Composite Structures
    • /
    • 제26권2호
    • /
    • pp.151-161
    • /
    • 2018
  • The application of carbon fiber reinforced polymer (CFRP) composites for rehabilitation of steel structures has become vital in recent years. This paper presents an experimental program and a finite element (FE) modelling approach to study the effectiveness of CFRP patch for repair of notch damaged circular hollow sectional (CHS) steel beams. The proposed modeling approach is unique because it takes into account the orthotropic behavior and stacking sequence of composite materials. Parametric study was conducted to investigate the effect of initial damage (i.e., notch depth) on flexural performance of the notched beams and effectiveness of the repair system using the validated FE models. Results demonstrated the ability of CFRP patch to repair notched CHS steel beams, restoring them to their original flexural stiffness and strength. The effect of composite patch repair technique on post-elastic stiffness was more pronounced compared to the elastic stiffness. Composite patch repair becomes more effective when the level of initial damage of beam increases.