• Title/Summary/Keyword: hip fracture

Search Result 203, Processing Time 0.036 seconds

A Biomechanical Study on a New Surgical Procedure for the Treatment of Intertrochanteric Fractures in relation to Osteoporosis of Varying Degrees (대퇴골 전자간 골절의 새로운 수술기법에 관한 생체역학적 분석)

  • 김봉주;이성재;권순용;탁계래;이권용
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.401-410
    • /
    • 2003
  • This study investigates the biomechanical efficacies of various cement augmentation techniques with or without pressurization for varying degrees of osteoporotic femur. For this study, a biomechanical analysis using a finite element method (FEM) was undertaken to evaluate surgical procedures, Simulated models include the non-cemented(i.e., hip screw only, Type I), the cement-augmented(Type II), and the cemented augmented with pressurization(Type III) models. To simulate the fracture plane and other interfacial regions, 3-D contact elements were used with appropriate friction coefficients. Material properties of the cancellous bone were varied to accommodate varying degrees of osteoporosis(Singh indices, II∼V). For each model. the following items were analyzed to investigate the effect surgical procedures in relation to osteoporosis of varying degrees : (a) von Mises stress distribution within the femoral head in terms of volumetric percentages. (b) Peak von Mises stress(PVMS) within the femoral head and the surgical constructs. (c) Maximum von Mises strain(MVMS) within the femoral head, (d) micromotions at the fracture plane and at the interfacial region between surgical construct and surrounding bone. Type III showed the lowest PVMS and MVMS at the cancellous bone near the bone-construct interface regardless of bone densities. an indication of its least likelihood of construct loosening due to failure of the host bone. Particularly, its efficacy was more prominent when the bone density level was low. Micromotions at the interfacial surgical construct was lowest in Type III. followed by Type I and Type II. They were about 15-20% of other types. which suggested that pressurization was most effective in limiting the interfacial motion. Our results demonstrated the cement augmentation with hip screw could be more effective when used with pressurization technique for the treatment of intertrochanteric fractures. For patients with low bone density. its effectiveness can be more pronounced in limiting construct loosening and promoting bone union.

Comparative Study of Compliance for Venous Thromboembolism Prophylaxis (American College of Chest Physicians Guideline and American College of Orthopedic Surgeons Guideline) in High Risk Patients with a Venous Thromboembolism (정맥혈전 색전증 고위험군에서 시행한 혈전색전 예방요법(American College of Chest Physicians 지침 및 American College of Orthopedic Surgeons 지침)의 준수율 비교 연구)

  • Suh, You-Sung;Nho, Jae-Hwi;Jang, Byung-Woong;Kang, Deokwon;Won, Sung-Hun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.4
    • /
    • pp.317-326
    • /
    • 2019
  • Purpose: To compare and analyze the rate of prevention of two venous thromboembolism prophylaxis guidelines in patients with artificial joint arthroplasty and hip joint fracture. Proper prophylaxis for preventing thromboembolism in orthopedic surgery is significant because of this fetal complication. Materials and Methods: This study compared and retrospective analyzed the rate of prevention using the medical records and radiographs of patients who underwent orthopedic surgery from March 2009 to February 2011 according to the American College of Chest Physicians (ACCP) guidelines and from March 2012 to February 2014 according to the American Academy of Orthopedic Surgeons (AAOS) guidelines. Results: The guidelines for venous thromboembolism prophylaxis have been applied to patients with artificial joint replacement and hip joint fracture, the compliance rate of the ACCP guidelines was 56.0% before surgery, 67.0% after surgery with chemical prophylaxis, and 80.5% with mechanical prophylaxis. In addition, the compliance rate of the AAOS guidelines was 74.1% with chemical prophylaxis, and 88.3% with mechanical prophylaxis, which was higher than the ACCP guidelines. The compliance rates of mechanical and chemical prophylaxis before and after surgery of the ACCP guidelines, and the compliance rate of mechanical and chemical prophylaxis of the AAOS guidelines were compared and analyzed. The results revealed statistical significance (p<0.05) before and after total knee replacement arthroplasty and hip joint fracture internal fixation and total high risk orthopedic surgery. Conclusion: Raising the compliance rate of prophylaxis of venous thromboembolism in high risk orthopedic surgery is necessary and people should follow the guidelines for a unified direction depending on which situation they are in.

Basic Study on the Development of Impact Protective Pants and Falls of Elderly Women (여성노인의 낙상실태 및 충격보호팬츠 개발을 위한 기초 연구)

  • Lee, Jin Suk;Park, Jung Hyun;Lee, Jeong Ran
    • Fashion & Textile Research Journal
    • /
    • v.16 no.6
    • /
    • pp.945-953
    • /
    • 2014
  • This study aims to develop protective pants to relieve impact from falls and to present basic data for the development. The survey results are as follows; First, 45% of the respondents were in their 60s and 55% of them were in their over 70s and older. Also, 64% of them have fallen once for the past year and 36% of them have fallen twice or more. The older they were, the more there were those who have fallen twice or more. This indicated the older people has experienced more fall accidents again after a initial fall accident. Second, as per accident situations, the survey showed that fall accidents happened the most in the winter and in the afternoon (12-18 pm). Also, it happened on a street mostly and they were wearing sneakers or hiking boots when they got a hurt slipped in a front or side by missing their step in a walk. The injury areas are mostly knee and ankle. They had the bruises or a sprain in their knee and ankle mostly. The rate of bone fracture was 19.5%. Therefore, the protection area to falls in lower body is the knee. But hip and hip joint should be protected with knee as well because those are usually be broken when it is damaged. Third, approximately 80% of those who were hospitalized for treatment had surgery. Patients who had surgery were rather in their over 70s than in their 60s. The older they were, the more serious their fracture was. The period of hospital or outpatient treatment is more than three weeks in many cases. They responded their health got worse after falls. Aftereffects of accidents were physical discomfort, anxiety and medical costs. Falls to the old makes physical damage, psychological damage, which cause reduced physical activity and the increased cost of health care with economic losses. So it results on a negative impact on the life of the old. Fourth, elderly females were rarely aware of impact protective clothing and they have never purchased such clothing. For impact protective pants, the major consideration was suitable design for their body types. They liked casual style with front or side pockets and simple designs without any patterns or decorations. As per pants materials, they responded that they need functionality, activity and elasticity. Among the functional points, insulation of cloths are considered importantly, so the heat reservance of material in the impact protective pants should be considered carefully.

Study on Injury Risk Factors of the Elderly for Safety·Security Design (안전·안심디자인을 위한 고령자의 손상 위험요인에 관한 연구)

  • Kim, Mi-Young
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.2
    • /
    • pp.105-112
    • /
    • 2017
  • This study recognizes it as a social problem that can be prevented by basic research on safety security design for the elderly, and aims to clearly analyze risk factors for injury. For this study, raw data from the 6th Korean National Health and Nutrition Survey were employed and analyzed. Their social characteristics were classified with standards including gender, education, EuroQoL(human locomotion, normal activity and pain uncomfortableness), the quality of life(PHQ-(1)(2)(4)), recognition on stress, activity restriction status and associated causes(bone fracture and joint injury). Their epidemiological traits were chronic diseases, 'diabetes and hip-joint pain', and health-behavioral traits were 'smoking, breakfast frequency and high-level physical activity status.' In conclusion, it can be found that damage risk of elderly rose in case of female, lower education, inconvenience or limitation, pain or discomfort in locomotion and daily activities, higher recognition of stress, lower interest in work, feeling of depression, despair, and weariness, restriction in activity caused by bone fracture and joint injury, having diabetes and hip-joint pain, smoking, low frequency in having breakfast and high-level physical activities. Based on this study, we envision that an effective solution for injury risk factors caused by the organic relation can be reached in the near future.

Changes In Mechanical Strength of Compression HIP Screws in Relation to Design Variations - A Biomechanical Analysis

  • Moon S. J.;Lee H. S.;Jun S. C.;Jung T. G.;Ahn S. Y.;Lee H.;Lee S. J.
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.2
    • /
    • pp.123-127
    • /
    • 2005
  • Compression Hip Screw (CHS) is one of the most widely-used prostheses for the treatment of intertrochanteric fractures because of its strong fixation capability. Fractures at the neck and screw holes are frequently noted as some of its clinical drawbacks, which warrant more in-depth biomechanical analysis on its design variables. The purpose of this study was to evaluate changes in the strength with respect to the changes in design such as the plate thickness and the number of screw holes. Both mechanical test and FEM analysis were used to systematically investigate the sensitivities of the above-mentioned design variables. For the first part of the mechanical test, CHS (n=20) were tested until failure. The CHS specimens were classified into four groups: Group Ⅰ was the control group with the neck thickness of 6-㎜ and 5 screw holes on the side plate, Group Ⅱ 6-㎜ thick and 8 holes, Group Ⅲ 7.5-㎜ thick and 5 holes, and Group Ⅳ 7.5-㎜ thick and 8 holes. Then, the fatigue test was done for each group by imparting 50% and 75% of the failure loads for one million cycles. For the FEM analysis, FE models were made for each group. Appropriate loading and boundary conditions were applied based on the failure test results. Stresses were assessed. Mechanical test results indicated that the failure strength increased dramatically by 80% with thicker plate. However, the strength remained unchanged or decreased slightly despite the increase in number of holes. These results indicated the higher sensitivity of plate thickness to the implant strength. No fatigue failures were observed which suggested the implant could withstand at least one million cycles of fatigue load regardless of the design changes. Our FEM results also supported the above results by showing a similar trend in stress as those of mechanical test. In summary, our biomechanical results were able to show that plate thickness could be a more important variable in design for reinforcing the strength of CHS than the number of screw holes.

Assessment of the Correlation for Geometry Transition using Bone Mineral Density in Proximal Femur (골밀도를 이용한 대퇴근위부 형태 변화의 상관관계 평가)

  • Kim, Da-Hye;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Ye, Soo-Young;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.12
    • /
    • pp.335-344
    • /
    • 2012
  • Osteoporosis is increasing in Korea as it becomes an aging society with the rapid economic growth and the development of medical technology. Osteoporosis also develops due to chemo and radiation therapy of cancer which also increases owing to Westernized diet. Osteoporosis is caused by reduced bone density, has close relationship with the change of geometry of proximal femur, which is a factor of hip fracture risk. The purpose of this study was the analysis of the correlations of osteoporosis and the change of geometry of proximal femur, which was observed according to T-score variance. The 350 male and female patients are chosen from D hospital in Busan, who were classified by age, sex and T-score values (normal, osteopenia, and osteo porosis). The results show that the age and gender have significant difference in the incidence of osteoporosis; the disease classification according to T-score value has significant difference in the geometry of the proximal femur such as Cortical ratio calcar, Cortical ratio shaft, Hip/shaft Angle, Strength index, Section modulus, CSMI, and CSA, and is highly correlated with the incidence of osteoporosis. Therefore, the findings of this research is that the change of the geometry of the proximal femur could be used as an indicator in the diagnosis of osteoporosis, could enhance the accuracy of the diagnosis in the future, and could be used as a clinical predictive factors through the analysis of the correlations of T-score variance and the geometry changes of the proximal femur.

Efficacy of Statins on BMB or Fracture Risk in Postmenopausal Women (스타틴이 폐경기 여성의 골밀도 혹은 골절위험에 미치는 효과 -보고된 임상연구결과 분석을 중심으로-)

  • Bang, Joon-Seok
    • Korean Journal of Clinical Pharmacy
    • /
    • v.16 no.2
    • /
    • pp.86-91
    • /
    • 2006
  • There are 3 different hypotheses on how statins may affect bones, through promoting bone formation, inhibiting bone resorption or through anti-inflammatory effect. In the 3 cross-sectional studies above, one showed increase BMD at hip and spine, one showed increase BMD only at mid-forearm and one showed that the risk reduction in fractures is not explained by the changes in BMD however, all 3 studies showed a decrease in risk of fracture associated with statins. In the 2 prospective cohort studies, one showed the use of statins was not associated with BMD at any skeletal site or decreasing the risk of fracture, and the other showed statins except pravastatin decreased in risk of vertebrate fracture but not affecting lumbar spine BMD. All of case-control studies indicated reduction in fracture risk but did not provide any data regarding BMD. 2 of the randomized, controlled studies showed no significant reduction in fracture risk as well as statins' effects on BMD. Finally, one longitudinal study showed statin use reduced fracture risk and increased BMD. Among the conflicting results shown above, even when statin use was shown to increase BMD, it does not seem to account for the reduction in fracture risk. There may be different ways that statins affect bone other than those hypotheses proposed above. Many studies seem to agree that pravastatin does not have any effect on bone. Some studies suggested that the reason statins did not achieve clinically significant increases in BMD in some studies, is due to the low affinity of statins on bone; statins are designed to act in the liver therefore their effective concentration in extrahepatic tissue is low. The limitations to those studies discussed above. Many studies did not account for the change of lifestyle while subjects' were on statins. Increases in weight bearing exercise and changes in diet might affect BMD and thus reduce risk of fractures. Mental alertness and vision acuity might prevent falls from occurring; many statin-users in the studies were young so the risk of fractures from falls would be decreased. Almost all of the studies failed exclude patients with neurological problems. During study periods, many subjects may have been started on drugs for diseases that usually occur with aging which could cause drowsiness and lead to falls. The sample sizes used in some of the trials were small and the duration of treatment and follow up might not have been long enough to see clinically relevant results.

  • PDF

Failure Mechanism and Test Method for Reliability Standardization of Solder Joints (솔더조인트의 신뢰성 표준화를 위한 취성파괴 메커니즘 및 평가법 연구)

  • Kim, Kang-Dong;Huh, Seok-Hwan;Jang, Joong-Soon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.4
    • /
    • pp.85-90
    • /
    • 2011
  • With regard to reliability of solder joint, the significant failures include open defects that occurs from alignment problem, Head in Pillow by PCB's warpage, the crack of solder by CTE mismatch, and the crack of IMC layer by mechanical impact. Especially as PCB down-sizing and surface finish is under progress, brittle failure of IMC layer between solder bump and PCB pad becomes a big issue. Therefore, it requires enhancing the level of difficulty in the existing assessment method and improving the measurement through the study on the mechanism of IMC formation, growth and brittle failure. Under this circumstance, this study is intended to suggest the direction of research for improving the reliability on the crack such as improvement of IMC brittle fracture.

New Approach in the Treatment of Intertrochanteric Fracture Using a Cephalomedullary Nail (골수정을 이용한 대퇴골 전자간 골절의 새로운 치료 경향)

  • Kim, Junyoung;Choi, Kihong;Yang, Kyu Hyun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.3
    • /
    • pp.193-199
    • /
    • 2020
  • A gamma nail has been used to treat intertrochanteric fractures since 1988. Although such cephalomedullary nails have mechanical advantages over extramedullary fixation devices, such as sliding hip screw, their beneficial effects on treating the Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) 31-A1 and 31-A2 fractures are still controversial. During their 30-year history, many problems have been overcome, and new types of cephalomedullary nails have been introduced in clinical practice. New cephalomedullary nail systems facilitate nailing procedures and enhance the purchase capability of the femoral head by a lag screw. On the other hand, the failure rate still depends on the hands of the orthopedic surgeons. This review article focused on the basic principle of medial support and restoration of a medial buttress during the treatment of trochanteric fractures using a cephalomedullary nail.

Modified External Skeletal Fixation for Craniodorsal Coxofemoral Luxation in 5 Dogs (개의 전배측 고관절 탈구에서 변형된 외골격 고정 적용 5례)

  • Jung, Chang-Su;Lim, Ji-Hey;Byeon, Ye-Eun;Kim, Wan-Hee;Yoon, Jung-Hee;Kweon, Oh-Kyeong
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.631-635
    • /
    • 2007
  • Luxation of the hip is the most common luxation seen in small animals. Luxations are classified by the direction in which the femoral head lies in relation to the acetabulum and craniodorsal luxations are the most common type. Recommendations for treatment are based on the presence of preexisting disease, the type and duration of luxation and severity of concurrent injuries. In this study modified external skeletal fixation was used for craniodorsal coxofemoral luxation in 5 dogs. Luxated head Joint was reduced and fixator pins were applied into the greater trochanter, the middle point of iliac body and the lateral surface of sacroiliac joint in a closed fashion. Reduction was successful in 4 of the 5 operated limbs. Complications noted in this study included pin tract drainage, pin loosening and secondary fracture at the pin insertion site.