• 제목/요약/키워드: high-volume

검색결과 6,371건 처리시간 0.032초

굵은골재 체적에 따른 고유동콘크리트의 유동특성에 관한 실험적 연구 (The Experience Study on the Floating Properties of High Flow Concrete on volum of Coarse Aggregate used Admixture)

  • 최성우;김호수;백철우;반성수;류득현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.751-754
    • /
    • 2004
  • There are many factors that affect on the flowing properties of high flowing concrete(HFC), which are fluidity, compactibility, non-segregation ability and fillingability. And because the aggregate which is one of the factors occupies high volume in concrete, it has a much effect on the properties of high flowing concrete according to its size, quality and quantity etc. This is an experimental study to analyze the effect of admixture and volume of coarse aggregate in concrete on the flowing properties of high flowing concrete. For this purpose, the kinds of admixture are fly-ash and blast furnace slag. Also volume of coarse aggregate in concrete are 280, 290, 300, 310, 320 $(\ell/m^3)$. The test of flowablity properties is slump-flow, Air content, V-lot, L-Flow. According to test results, it was found that the compactibility of HFC is more superior to use blast furnace slag than other, and according .to kind of admixture, most compatible volume of coarse are different. Also when used blast furnace slag, the volume of coarse are increased than used fly-ash.

  • PDF

정상체중과 과체중 여대생을 대상으로 컵의 형태에 따른 인지량의 차이에 관한 연구 (Difference in Volume Perception according to Cup Shape in Normal Weight and Overweight Female College Students)

  • 이명옥;장은재
    • 대한영양사협회학술지
    • /
    • 제20권1호
    • /
    • pp.63-69
    • /
    • 2014
  • The volume perception of water according to cup shape was examined in female college students divided into a normal weight group (<23 body mass index, n=51) and an overweight group (${\geq}$23 body mass index, n=48). The perceived water volume was recorded by participants after they observed the water volume in cups with different shape (highball and tumbler) and with different base height (high base and low base), which contained the same amount of water (150 ml). The normal weight group perceived a water volume of 238.5 ml (highball) and 201.6 ml (tumbler) for the high base cups. The overweight group perceived a volume of 245.6 ml (highball) and 188.8 ml (tumbler). For the low base cups, the normal weight group perceived a water volume of 207.8 ml (highball) and 104.1 ml (tumbler). The overweight group perceived a volume of 202.2 ml (highball) and 100.4 ml (tumbler). Both the normal weight and overweight groups perceived significantly more liquid in the highball cups compared to the tumbler cups. In addition, both groups perceived significantly more liquid in the high base cups compared to the low base cups. However, there were no significant differences in the estimated variance of perceived volume between the normal weight and overweight groups according to the cup shape and cup base height. In conclusion, cup shape and base height potentially affects volume perception. Therefore, modifying cup shape may be used in a weight control program to help control caloric beverage consumption.

경부고속철도 수송수요의 예측치와 실측치의 비교분석 (Comparative Analysis of Forecasted and Measured Traffic Demand for Gyung-bu High Speed Railway)

  • 오인택
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.889-896
    • /
    • 2005
  • While a year and a half has been passed since the launch of KTX service, traffic volume of Gyung-bu High Speed Railway is still much lower than the forecasted value. This situation has been badly affecting not only Korail's financial status but also KRNA's general railway construction projects as general public responds negatively to such projects as New Ho-nam Line Construction. This paper outlines traffic volume forecasting methodologies applied to construction of Gyung-bu High Speed Railway, identifies major causes of forecasting deviations. and finally extracts problems through comparison between the forecasted results and actual traffic volume.

  • PDF

차세대 웹 환경에서 Complex Event Processing 엔진을 이용한 대용량데이터 처리 (High-Volume Data Processing using Complex Event Processing Engine in the Web of Next Generation)

  • 강만모;구자록;이동형
    • 한국정보과학회논문지:데이타베이스
    • /
    • 제37권6호
    • /
    • pp.300-307
    • /
    • 2010
  • 웹이 성장함에 따라 데이터처리 기술도 발전하고 있다. 차세대 웹 환경에서는 다양한 유무선 사용자, USN, RFID를 위한 고속, 대용량데이터 처리기술 또한 발전하고 있다. 본 논문에서는 CEP(Complex Event Processing) 엔진을 이용하여 대용량데이터를 처리하는 기술을 제안한다. CEP는 복잡한 이벤트를 처리하는 기술로 CEP 엔진은 다음과 같은 특정이 있다. 첫째 대용량의 이벤트(데이터)를 받는 작업, 둘째 이를 분석하는 작업, 최종적으로 새로운 액션으로 연결시키는 작업으로 나눌 수 있다. 즉 대용량데이터를 수집하고 이벤트들을 분석, 필터링한다. 또한 이벤트 엔진에 미리 등록해 놓은 이벤트와 새로운 이벤트를 패턴매칭하여 데이터를 추출한다. 추출된 결과를 다른 작업의 입력 이벤트로 사용하거나 요청된 이벤트에 대해 실시간으로 응답할 수 있고 유효한 데이터만 데이터베이스에 트리거할 수도 있다.

조골재 크기 및 용적비에 의한 고유동콘크리트의 각종 유동특성에 관한 실험적 연구 (An Experimental Study on the Fluidity Properties of High Flowing Concrete Affected by Size and Volume Ratio of Coarse Aggregate)

  • 최세진;김완영;김진만;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표논문집(II)
    • /
    • pp.258-261
    • /
    • 1998
  • Aggregate is cheaper than cement and confers considerable technical advantages on concrete, which has a higher volume stability and better durability than hydrated cement paste alone. and coarse aggregate is the largest particle size out of concrete and is much affect on the fruidity, compaction and non-segregation ability of high flowing concrete. As the compaction, fillingability and shrinkage of high flowing concrete, the volume ratio of coarse aggregate is prescribed by Japanese Architectural Standard Specificateon (JASS 5) : from 0.500 to 0.500㎥/㎥. It is the aim of this study to compare and analysis the fruidity, fillingability and non-segregation of high flosing concrete according to the volume ratio of coarse aggregate of concrete(G/Glim).

  • PDF

플라이애시를 대량 사용한 콘크리트의 배합설계를 위한 기초적 연구 (A Fundamental Study on the Mix Design in High Volume Fly-Ash Concrete)

  • 심재형;김재환;최희용;강석표;최세진;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.641-646
    • /
    • 2001
  • Generally, when Fly-Ash was used as replacement material of cement in concrete, it might occur retardation of setting and hardening. So, it is unable to use a large amount of Fly-Ash as replacement for cement. However, if it is used as replacement material of fine aggregate in concrete, we can use a large amount of Fly-Ash and settle a problem of natural-aggregate exhaustion. Furthermore, engineering properties of High Volume Fly-Ash Concrete Is better than that of plain concrete But, the larger Fly-Ash is replaced, the more fluidity of High Volume Fly-Ash Concrete decrease, because porous organization of Fly-Ash adsorb water and Superplasticizer. In this study, after appending additional water to High Volume Fly-Ash Concrete in proportion to weight of Fly-Ash, we intend to find proper ratio which doesn't affect strength and satisfy fluidity As a result of this study, it was found that fluidity of mortar with 25~28 percentage of additional water was satisfied with fluidity of plain mortar, and compressive strength of that was similar to plain mortar's

  • PDF

플라이애쉬를 다량 치환한 콘크리트의 양생온도에 따른 강도성상 (Strength Properties by Curing Temperature of High Volume Fly-Ash Concrete)

  • 이동하;정근호;백민수;김성식;임남기;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술.기술논문발표회
    • /
    • pp.63-66
    • /
    • 2002
  • In this study, it does a high volume flyash substituted concrete experiments in two curing temperature circumstances - 35$^{\circ}C$, 2$0^{\circ}C$. High volume flyash concrete is tested in fresh concrete properties and hardeded concrete properties. In the fresh concrete test items, there is slump, air contents, concrete setting tests. 3, 7, and 28 days water curing compressive strength is measured in the hardened concrete test. The purpose of this study is to submit a various flyash concrete data for application to field. The result of this study is that the best strength is developed at the plain concrete cured 2$0^{\circ}C$ and Mixing F43 shows the best strength among specimens which cured at 35$^{\circ}C$

  • PDF

순환골재 및 소각장 애시를 자극제로 사용한 고로슬래그 미분말 다량치환 콘크리트의 Mock-up 성능평가 (Mockup Test of the High Volume Blast Furnace Slag Concrete Using Recycled Aggregates and Incinerator Ash)

  • 김영희;곽용진;김준호;이향재;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.19-21
    • /
    • 2012
  • This paper was to investigate the effect of incinerator ash on engineering properties of the high volume blast furnace slag concrete through Mock-up test. Test results revealed that the use of recycled aggregates resulted in increase of slump compared with the OPC concrete. But, the use of recycled aggregates did not affect the results of air contents and chloride contents. The use of recycled aggregates showed shortening of setting time of high volume blast furnace slag concrete. When the recycled aggregate was used, delay in strength development at early age happened with high volume blast furnace slag concrete compared with that of OPC concrete.

  • PDF

병용계 고유동 콘크리트의 배합요인에 따른 특성 (Properties of the Combined High Flowing Concrete by Mix Design Factors)

  • 권영호;이현호;이화진;하재담
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.407-410
    • /
    • 2005
  • This research investigates experimentally an effect on the properties of the combined high flowing concrete by mix design factors. The purpose of this study is to determine the optimum mix proportion of the combined high flowing concrete having good flowability, viscosity, no-segregation and design strength(40.0MPa). For this purpose, trial mixings used belite cement+lime stone powder(LSP) are tested by mix design factors including water-cement ratio($47.9\~54.0\%$), fine aggregate volume ratio($41\~45\%$) and coarse aggregate volume ratio($41\~45\%$). As test results of this study, the optimum mix proportion for the combined high flowing concrete is as followings. Water-cement ratio $51.0\%$, fine aggregate volume ratio $43{\pm}1\%$ and coarse aggregate volume ratio $0.30{\pm}0.05m^3/m^3$ and replacement ratio of LSP $42.7\%$.

  • PDF

Efficacy of Gamma Knife Radiosurgery for Recurrent High-Grade Gliomas with Limited Tumor Volume

  • Cheon, Young-Jun;Jung, Tae-Young;Jung, Shin;Kim, In-Young;Moon, Kyung-Sub;Lim, Sa-Hoe
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권4호
    • /
    • pp.516-524
    • /
    • 2018
  • Objective : This study aims to determine whether gamma knife radiosurgery (GKR) improves survival in patients with recurrent high-grade gliomas. Methods : Twenty nine patients with recurrent high-grade glioma underwent 38 GKR. The male-to-female ratio was 10 : 19, and the median age was 53.8 years (range, 20-75). GKR was performed in 11 cases of recurrent anaplastic oligodendrogliomas, five anaplastic astrocytomas, and 22 glioblastomas. The median prescription dose was 16 Gy (range, 10-24), and the median target volume was 7.0 mL (range, 1.1-15.7). Of the 29 patients, 13 (44.8%) received concurrent chemotherapy. We retrospectively analyzed the progression-free survival (PFS) and overall survival (OS) after GKR depending on the Eastern Cooperative Oncology Group (ECOG) performance status (PS), pathology, concurrent chemotherapy, radiation dose, and target tumor volume. Results : Starting from when the patients underwent GKR, the median PFS and OS were 5.0 months (range, 1.1-28.1) and 13.0 months (range, 1.1-75.1), respectively. On univariate analysis, the median PFS was significantly long in patients with anaplastic oligodendroglioma, ECOG PS 1, and target tumor volume less than 10 mL (p<0.05). Meanwhile, on multivariate analysis, patients with ECOG PS 1 and target tumor volume less than 10 mL showed improved PFS (p=0.043 and p=0.007, respectively). The median OS was significantly increased in patients with ECOG PS 1 and tumor volume less than 10 mL on univariate and multivariate analyses (p<0.05). Conclusion : GKR could be an additional treatment option in recurrent high-grade glioma, particularly in patients with good PS and limited tumor volume.