• Title/Summary/Keyword: high-temperature area

Search Result 2,609, Processing Time 0.031 seconds

Distribution of Nutrients and Phytoplankton Biomass in the Area Around the South Shetland Islands, Antarctica (남극 남쉐틀랜드군도 주변 해역의 영양염과 식물플랑크톤 생물량 분포)

  • Kim, Dong-Seon;Kang, Sung-Ho;Kim, Dong-Yup;Lee, Youn-Ho;Kang, Young-Chul
    • Ocean and Polar Research
    • /
    • v.23 no.2
    • /
    • pp.77-95
    • /
    • 2001
  • Temperature, salinity, nutrients, chlorophyll-a, and primary production were measured within the upper 200 m water column in the area around the South Shetland Islands in January, 2000. Surface temperature was relatively high in the Drake Passage north of the South Shetland Islands and low in the northeastern area of the Antarctic Peninsula. In contrast, surface salinity was low in the Drake Passage and increased toward the Antarctic Peninsula, reaching the maximum value in the northeastern area of the Antarctic Peninsula. Surface nutrients were low in the Drake Passage and high in the area near the South Shetland Islands. Surface chlorophyll-a was also low in the Drake Passage and near the Antarctic Peninsula and high in the area of the northern King George Island. The study area could be classified as four geographical zones based on the characteristic shape of the T/S diagrams;the Drake Passage, the Bransfield Strait, the mixed zone, and the Weddell Sea. Each geographical zone showed apparently different physical, chemical, and biological characteristics. Phytoplankton biomass was relatively low in the Drake Passage and the Weddell Sea and high in the Bransfield Strait and the mixed zone. The low phytoplankton biomass in the Weddell Sea could be explained by the low water temperature and deep surface mixing down to 200 m. The high grazing pressure and low availability of iron could be responsible for the low phytoplankton biomass in the Drake Passage.

  • PDF

Characteristics of Surface High Ozone Concentration on Pusan Coastal area, Korea (부산 해안지역의 고농도 오존 발생 특성에 관한 연구)

  • 전병일
    • Journal of Environmental Science International
    • /
    • v.9 no.4
    • /
    • pp.295-302
    • /
    • 2000
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone, nitrogen dioxide and meteorological data for 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was the highest at Dongsamdong in Spring(35.4ppb), at Kwangbokdong in Fall(25.1ppb) and the lowest Dongsamdong(22.2ppb) and Kwangbokdong(16.0ppb) in Winter. Relative standard deviation indicating clearness of observation site was 0.42 at Dongsamdong and 0.49 at Kwangbokdong that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong and Kwangbokdong showed maximum at 1500~1600LST and minimum 0700~0800LST that typical pattern of ozone concentration. In ozone episode period(Sept. 10~15, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface. During the episode days peak ozone concentrations are much higher than the normal values, wind speeds are always lower, and solar radiation is high with the exception of the September episode.

  • PDF

Numerical Study on Comparison of Serpentine and Parallel Flow Channel in High-temperature Proton Exchange Membrane Fuel Cells (고온형 고분자전해질형 연료전지에서의 사형 유로와 평행 유로 성능비교에 대한 수치해석적 연구)

  • AHN, SUNGHA;OH, KYEONGMIN;JU, HYUNCHUL
    • Journal of Hydrogen and New Energy
    • /
    • v.29 no.1
    • /
    • pp.41-55
    • /
    • 2018
  • General polymer electrolyte fuel cell (PEMFC) operates at less than $80^{\circ}C$. Therefore liquid phase water resulting from electrochemical reaction accumulates and floods the cell which in turn increases the mass transfer loss. To prevent the flooding, it is common to employ serpentine flow channel, which can efficiently export liquid phase water to the outlet. The major drawback of utilizing serpentine flow channel is the large pressure drop that happens between the inlet and outlet. On the other hand, in the high temperature polymer electrolyte fuel cell (HT-PEMFC), since the operating temperature is 130 to $180^{\circ}C$, the generated water is in the state of gas, so the flooding phenomenon is not taken into consideration. In HT-PEMFCs parallel flow channel with lower pressure drop between the inlet and outlet is employed therefore, in order to circulate hydrogen and air in the cell less pumping power is required. In this study we analyzed HT-PEMFC's different flow channels by parallel computation using previously developed 3-D isothermal model. All the flow channels had an active area of $25cm^2$. Also, we numerically compared the performance of HT-PEMFC parallel flow channel with different manifold area and Rib interval against the original serpentine flow channel. Results of the analysis are shown in the form of three-dimensional contour polarization curves, flow characteristics in the channel, current density distribution in the Membrane, overpotential distribution in the catalyst layer, and hydrogen and oxygen concentration distribution. As a result, the performance of a real area fuel cell was predicted.

Construction and Case Analysis of Detailed Urban Characteristic Information on Seoul Metropolitan Area for High-Resolution Numerical Weather Prediction Model (고해상도 수치예보모델을 위한 수도권지역의 상세한 도시특성정보 구축 및 사례 분석)

  • Lee, Hankyung;Jee, Joon-Bum;Yi, Chaeyeon;Min, Jae-Sik
    • Atmosphere
    • /
    • v.29 no.5
    • /
    • pp.567-583
    • /
    • 2019
  • In this study, the high-resolution numerical simulations considering detailed anthropogenic heat, albedo, emission and roughness length are analyzed by using single layer Urban Canopy Model (UCM) in Weather Research Forecast (WRF). For this, improved urban parameter data for Seoul Metropolitan Area (SMA) was collected from global data. And then the parameters were applied to WRF-UCM model after it was processed into 2-dimensional topographical data. The 6 experiments were simulated by using the model with each parameter and verified against observation from Automated Weather Station (AWS) and flux tower for the temperature and sensible heat flux. The data for sensible heat flux of flux towers on Jungnang and Bucheon, the temperature of AWS on Jungnang, Gangnam, Bucheon and Neonggok were used as verification data. In the case of summer, the improvement of simulation by using detailed anthropogenic heat was higher than the other experiments in sensible flux simulation. The results of winter case show improved in all simulations using each advanced parameters in temperature and sensible heat flux simulation. Improvement of urban parameters in this study are possible to reflect the heat characteristics of urban area. Especially, detailed application of anthropogenic heat contributed to the enhancement of predicted value for sensible heat flux and temperature.

Design and Performance Test of Large-Area Susceptor for the Improvement of Temperature Uniformity (온도 균일도 향상을 위한 대면적 서셉터의 설계 및 성능 시험)

  • Yang, Hac Jin;Kim, Seong Kun;Cho, Jung Kun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.3714-3721
    • /
    • 2015
  • Although sheath-type heating line is generally used for susceptor heater, performance deterioration problems in temperature uniformity occurs in the case of large scale and high temperature condition. We developed new design and prototype of the susceptor using sheet metal to provide performance improvement in temperature uniformity. Temperature uniformity below 1.4% in the surface temperature condition of $450^{\circ}C$ was verified in the susceptor prototype. Also we developed Kernel regression algorithm to estimate measured temperature using temperature learning data. The reliability of the measured temperature uniformity was confirmed by comparative analysis between predicted data and measured data.

Flow and heat transfer in a thermal CVD for carbon nanotubes according to variation of the inlet and outlet areas (유입.유출구 크기 변화에 따른 CNT용 CVD 장비 내의 열 및 유동해석)

  • Ha, Da-Som;Jang, Young-Woon;Kim, Jong-Seok;Yoon, Suk-Bum;Im, Ik-Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.4
    • /
    • pp.119-124
    • /
    • 2011
  • Flow and temperature field in reactors are important factors for design of thermal chemical vapor deposition system to grow carbon nanotubes. In this study, effects of the variations of the inlet and outlet areas of the CVD reactor to the flow characteristics and temperature field are numerically analyzed. High temperature of the gas in the entrance region is obtained with slow gas speed resulted from the enlarged inlet area. Variation of the exit area has little effects on the flow field and temperature in the reactor. However the largest area among considered cases gives the highest gas temperature though the differences are small.

Analysis of the Characteristics of Thermal Environment Change Due to Urban Stream Restoration (도심 하천 복원에 따른 주변지역 열환경 변화 특성 분석)

  • Do, Woo-Gon;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.28 no.2
    • /
    • pp.235-248
    • /
    • 2019
  • The purpose of this study is to quantitatively analyze the effects of a restoration project on the decrease in the temperature in the surrounding areas. The thermal environment characteristics of the investigation area were analyzed using the meteorological data from the Busanjin Automatic Weather System which is closest to the target area. The terrain data of the modeling domain was constructed using a digital map and the urban spatial information data, and the numerical simulation of the meteorological changes before and after the restoration of the stream was performed using the Envi-met model. The average temperature of the target area in 2016 was $15.2^{\circ}C$ and was higher than that of the suburbs. The monthly mean temperature difference was the highest at $1.1^{\circ}C$ in November and the lowest in June, indicating that the temperatures in the urban areas were high in spring and winter. From the Envi-met modeling results, reductions in temperature due to stream restoration were up to $1.7^{\circ}C$ in winter, and decreased to $3.5^{\circ}C$ in summer. The effect of temperature reduction was seen in the entire region where streams are being restored.

Synthesis, Characterization and Ammonia Decomposition Reaction Activity of Vanadium Oxynitride Obtained from the Reduction/Nitridation of Vanadium Oxide (바나디움 산화물의 환원 및 질화반응으로부터 얻어진 바나디움 산화질화물의 제조, 특성분석 및 암모니아 분해반응에서의 촉매 활성)

  • Yun, Kyung Hee;Shin, Chae-Ho
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.620-629
    • /
    • 2022
  • By varying various experimental conditions such as heating rate, molar hourly space velocity (MHSV), and nitridation reaction temperature, vanadium oxynitride was prepared through temperature programmed reduction/nitridation reaction (TPRN) of vanadium pentoxide and ammonia, and characterization were performed. In order to investigate the physico-chemical properties of the prepared catalyst, N2 adsorption-desorption analysis, X-ray diffraction analysis (XRD), hydrogen temperature programmed reduction (H2-TPR), temperature programmed oxidation (TPO), ammonia temperature programmed desorption (NH3-TPD), transmission electron microscopy (TEM) was performed. Transformation of V2O5 with 5 m2 g-1 low specific surface area by reduction at 340 ℃ to V2O3 showed a high specific surface area value of 115 m2 g-1 by micropore formation. As the nitridation temperature increased beyond that, the specific surface area continued to decrease due to sintering. The nitridation reaction variable that had the greatest influence on the specific surface area was the reaction temperature, and the x + y value of VNxOy of a single phase approached from 1.5 to 1.0 as the nitridation reaction temperature increased. At a high reaction temperature of 680 ℃, the cubic lattice constant a was VN. close to the value. At 680 ℃, the highest nitridation temperature among the experimental conditions, the ammonia conversion rate was 93%, and no deactivation was observed.

Retrieval of Land SurfaceTemperature based on High Resolution Landsat 8 Satellite Data (고해상도 Landsat 8 위성자료기반의 지표면 온도 산출)

  • Jee, Joon-Bum;Kim, Bu-Yo;Zo, Il-Sung;Lee, Kyu-Tae;Choi, Young-Jean
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.2
    • /
    • pp.171-183
    • /
    • 2016
  • Land Surface Temperature (LST) retrieved from Landsat 8 measured from 2013 to 2014 and it is corrected by surface temperature observed from ground. LST maps are retrieved from Landsat 8 calculate using the linear regression function between raw Landsat 8 LST and ground surface temperature. Seasonal and annual LST maps developed an average LST from season to annual, respectively. While the higher LSTs distribute on the industrial and commercial area in urban, lower LSTs locate in surrounding rural, sea, river and high altitude mountain area over Seoul and surrounding area. In order to correct the LST, linear regression function calculate between Landsat 8 LST and ground surface temperature observed 3 Korea Meteorological Administration (KMA) synoptic stations (Seoul(ID: 108), Incheon(ID: 112) and Suwon(ID: 119)) on the Seoul and surrounding area. The slopes of regression function are 0.78 with all data and 0.88 with clear sky except 5 cloudy pixel data. And the original Landsat 8 LST have a correlation coefficient with 0.88 and Root Mean Square Error (RMSE) with $5.33^{\circ}C$. After LST correction, the LST have correlation coefficient with 0.98 and RMSE with $2.34^{\circ}C$ and the slope of regression equation improve the 0.95. Seasonal and annual LST maps represent from urban to rural area and from commercial to industrial region clearly. As a result, the Landsat 8 LST is more similar to the real state when corrected by surface temperature observed ground.

The Effects of Temperature Change on the Bending Strength of CF/PEEK Laminates after Impact (온도변화가 CF/PEEK 적층재의 충격 후 굽힘강도에 미치는 영향)

  • 양인영;정종안;나승우
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.2
    • /
    • pp.34-39
    • /
    • 2003
  • In this paper, when CF/PEEK laminates for high efficiency space structure are subjected to FOD(Foreign Object Damage), the effects of temperature change on the impact damages(interlaminar separation and transverse crack) of CF/PEEK laminates and the relationship between residual lift and impact damages are experimentally investigated. Composite laminates used in this experiment are CF/PEEK orthotropic laminated plates, which have two-interlaces [$0^{\circ}_4/90^{\circ}_8/0^{\circ}_4$]. A steel ball launched by the air gun collides against CF/PEEK laminates to generate impact damages. And then CF/PEEK specimens with impact damages are observed by a scanning acoustic microscope under room and high temperatures. In this experimental results, various relations are experimentally observed including the delamination area vs. temperature change, the bending strength vs. impact energy and the residual bending strength vs. impact damage of CF/PEEK laminates.