• Title/Summary/Keyword: high-pressure mercury lamp

Search Result 32, Processing Time 0.027 seconds

The Lighting Properties on a gymnasium in the school (초.중.고등학교 체육관의 조도특성 분석)

  • Kim, Un-Hyun;Kim, Hee-Jun;Park, Tong-Wha
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2426-2427
    • /
    • 1999
  • This study is the result of determination and analysis to draw out six schools in order to research into the lighting properties of the school Almost schools are supported and used large area by a high brightness lamp, for example high pressure mercury discharge lamp etc. The gymnasium of A, B, E schools have a good capacity of the illuminance.

  • PDF

Analysis of the Effect on the Performance of Ceramic Metal Halide Lamp by the Loss of Elements that have been Filled in Arc Tube (아크튜브내의 구성물 손실이 세라믹 메탈 핼라이드 램프의 특성에 미치는 영향분석)

  • Jang, Hyeok-Jin;Yang, Jong-Kyung;Park, Dae-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2446-2452
    • /
    • 2009
  • A Ceramic Metal-halide lamp is achieved by adding multiple metals to a basic mercury discharge. Because the vapor pressure of most metals is very much lower than mercury itself, metal-halide salts of the desired metals, having higher vapor pressures, are used to introduce the material into the basic discharge. The metal compounds are usually polyatomic iodides, which vaporize and subsequently dissociate as they diffuse into the bulk plasma. Metals with multiple visible transitions are necessary to achieve high photometric efficiency and good color. Compounds of Sc, Dy, Ho, Tm, Ce, Pr, Yb and Nd are commonly used. The maximum visible efficacy of a Ceramic Metal Halide lamp, under the constant of a white light source, is predicted to be about 450lm/W. This is controlled principally by the chemical fill chosen for a particular lamp. Current these lamps achieve 130lm/W and these life time are the maximum 16,000[hr]. So factors of performance lower are necessary to improve lamp performance. In this paper, we analyzed factors of performance lower by accelerated deterioration test. The lamp was operated with short duration turn-on/turn-off procedure to enhance the effect due to electrode sputtering during lamp ignition. The tested lamp that was operated with a longer turn-on/off(20/20 minutes) showed blackening, changed distance between electrodes and lowered color rendering & color temperature by losses of Dy at 421.18nm, I at 511nm, T1 at 535nm and Na at 588nm compared with the new lamp.

High Luminous Efficiency Flat Light Source with Xe mixture Gas Discharge and Areal Brightness Control Method (제논 혼합가스를 이용한 고효율 면광원과 국부적 밝기 제어 방식)

  • Jung, Jae-Chul;Seo, In-Woo;Oh, Byung-Joo;Whang, Ki-Woong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.153-157
    • /
    • 2009
  • A Highly efficient Mercury-free Flat Fluorescent Lamp (MFFL) with dielectric barrier Xe gas discharge was developed for an alternative of conventional line-type Cold Cathode Fluorescent Lamps (CCFLs) which shows a wide voltage margin and a stable discharge operation for diffuse glow discharge with an application of a auxiliary electrode. Electro-optic characteristics of the MFFL were examined through the changes in ambient temperature, total pressure and Xe partial pressure. the single cell is expanded into a multi-structured configuration to realize a large sized lamp by a simple repetition of the single cells, and a new driving scheme is proposed for an adaptive brightness control using dual auxiliary electrodes and bi-polar drive scheme. In addition, interesting application of this ultra high luminance flat lamp by the optimization of the gas condition and the pattern of the rear phosphor layer is suggested as a good alternative of daylight lamp source

  • PDF

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF

Mathematical Model for High Pressure Mercury Lamp (고압수은등의 수학적 모델링)

  • 진상규;김석환;지철근
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.5
    • /
    • pp.19-23
    • /
    • 1994
  • 방전등 점등회로의 이론적 해석을 위해서 방전등을 충실히 표현할 수 있는 수식 모델이 필요하다. 본 논문에서는 방전등 내 전자 밀도의 변화를 토대로 만족 할 만한 수식 모델을 제시하였다. 한편, 램프의 전압 전류의 수식 모델을 이용하여 구한 값을 실측치와 비교하여 검증하였고, 수식 모델의 간단한 응용예를 보였다.

  • PDF

A Study on the Analysis of Various Characteristics for the High Pressure are Discharge System (고압 아아크 방전시스템의 각종 특성 해석에 관한 연구)

  • 지철근;박왕열;이진우
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.5 no.4
    • /
    • pp.35-42
    • /
    • 1991
  • Recently, HID lamps have been considered as important in regard to the trend of energy saving, and increasingly and diversely used in various ways. This paper will show the simulating models concerning high-pressure arc discharge system directly applicable for its design and manufacture, and analyze its various characteristics. For warm-up characteristics, the evaporating process of inner atoms is described in terms of second-order differential equation: for the thermal conduction from are axis to discharge wall and outer bulb, its transfer process is introduced according to five first-order differential equations. Under the steady state satisfying LTE, the time-variant characteristics are suggested by means of time-dependent energy balance equation derived from fluid equations, approximation of radiation energy and material functions in the discharge tube. The simulating models concerning these equations are then applied for high-pressure mercury lamp.

  • PDF

Properties of Longitudinal & Transverse Discharge in a Tubular Fluorescent Lamp (직관형 형광램프의 종단방전과 횡단방전의 특성)

  • Chung, J.Y.;Kim, J.H.;Jeong, J.M.;Jin, D.J.;Kim, H.C.;Bong, J.H.;Hwang, H.C.;Lee, M.S.;Koo, J.H.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.322-330
    • /
    • 2008
  • The properties of discharge, luminance, and spectroscopy are investigated in a longitudinal and transverse discharge fluorescent lamps with tube of outer diameter 4 mm. The sample lamps are prepared to be three kinds of gas composition such as mercury lamps of Ne(95%)+Ar(5%)+Hg(2 mg), the mercury-free lamps of Xe 100% and Ne+Xe(4%). The gas pressure is in the range of $5{\sim}300\;Torr$. In the mercury lamps, the longitudinal discharge having a positive column is high in luminance and efficiency, while the transverse discharge is no luminance at all. In the Xe-lamps, the transverse discharge shows relatively good in efficiency as compared with the longitudinal discharge which has a high discharge voltage and a low luminance and efficiency. In the transverse discharge of relatively high efficiency, a pure Xe(100%) gas discharge has a higher efficiency than the mixture gas of Ne+Xe(4%). Through these experiments, the properties of mercury and xenon lamps are verified. In the mercury lamps, the longitudinal discharge of tubular fluorescent lamps is high in luminance and efficiency, while the transverse discharge of flat panel fluorescent lamps are low in luminance efficiency. In the mercury-free lamps, the flat fluorescent lamps of transverse discharge having a high pressure ${\sim}100\;Torr$ with the pure Xe-gas are verified to be suggestable.

The Study on Optical Properties of Xenon ICP Lamp Dependently on Gas Pressure and Input Power (ICP 제논 램프의 가스 압력과 공급 전력에 따른 광학적 특성연구)

  • Choi, Gi-Seung;Lee, Seong-Jin;Lee, Jung-Chan;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1659-1660
    • /
    • 2006
  • After end of the 20th environmental problem was became issue. So about mercury free lighting sources are being studied very much. In this paper, a mercury and electrode free bulb was designed. in this bulb was injected mixed of Xe, Ne and Kr Gases. and then the bulb was discharged by 13.56MHz RF Power after spectrum, color coordinates and brightness were measured by spectrum meter CS-1000. Measured results were compared and analyzed, also analysis was able to do a characteristic of a gas defensive fight in proportion to a mixing ratio. Therefore the most of high brightness which was 4500cd/m2 was gained in 1:1 ratio of Xe:Ne at 60W input power.

  • PDF

Synthesis and Photoisomerization Properties of Polynorbornenes with Azobenzene Chromophores

  • Kang, Suk-Hoon;Shin, Hee-Deuk;Oh, Cha-Hwan;Choi, Dong-Hoon;Park, Ki-Hong
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.7
    • /
    • pp.957-963
    • /
    • 2002
  • We successfully synthesized the addition-type polynorbonenes (PNB) exhibiting photochromic properties and excellent thermal stability. Three norbornene-based monomers with different azobenzene moiety (R=NO2, H,OCH3) were synthesized by transesterification method. The corresponding PNB copolymers were synthesized by transition metal-catalyzed addition polymerization method, and characterized by GPC, UV-Vis spectroscopy, NMR, and thermal analysis. For comparison of the photochromic properties depending on the rigidity of polymer backbone, we prepared the polymethylmethacrylate (PMMA) copolymer with the corresponding azobenzene moiety. We investigated the photoisomerization behavior by means of optical muitichannel analyzer with Xe lamp as well as real-time UV-Vis spectroscopy with high-pressure mercury lamp. Among three PNB copolymers, a polymer with azobenzene (R=H) was the most adaptable for observation of photoisomerization behavior. It was found that the rate of photoisomerization and relaxation depended on the structure of azobenzene chromophore, rather than that of polymer backbone.

The High Efficiency of Amorphous-Si Solar Cells Prepared by Photo-CVD System (광(光) CVD 법(法)에 의한 a-Si 태양전지(太陽電池)의 고효율화에 관한 연구(硏究))

  • Kim, Tae-Seoung
    • Solar Energy
    • /
    • v.5 no.2
    • /
    • pp.46-53
    • /
    • 1985
  • Hydrogenated amorphous silicon solar cells which are fabricated by photo-chemical vapor deposition (photo-CVD) system has been investigated. In the photo-CVD system which consists of three separate reaction chambers, low-pressure mercury lamp has been used as a light source. The main reactant ($Si_2H_6/He$) gases which are premixed with a small amount of mercury vapor in a mercury-vaporizer kept at $50^{\circ}C$ have been used. Using $C_2H_2$ and $SiH_2(CH_3)_2$ as the carbon source, p-type wide band gap a-SiC:H films have been obtained. The result has been found that the undoped layers of the pin/substrate solar cells are influenced by the residual impurities, such as phosphorus and boron during the deposition process. By minimizing the effect of the impurities in the i-layer and optimizing conditions at the p-layer and p/i interface, the energy conversion efficiency of 9.61 % under AM-1 ($100mW/Cm^2$) has been achieved for pin/substrate solar cells illuminated through their p-layers, using the three separate reaction chamber apparatus. It is expected that a-SiC:H solar cells with the energy conversion efficiency over 10% have been fabricated by Photo-CVD method.

  • PDF