• 제목/요약/키워드: high-pressure effects

검색결과 2,110건 처리시간 0.036초

Effects of Time-Dependent High Pressure Treatment on Physico-chemical Properties of Pork

  • Hong, Geun-Pyo;Park, Sung-Hee;Kim, Jee-Yeon;Lee, Si-Kyung;Min, Sang-Gi
    • Food Science and Biotechnology
    • /
    • 제14권6호
    • /
    • pp.808-812
    • /
    • 2005
  • The effects of high pressure processing, pressure level (50, 100, 150, and 200 MPa) and pressurized time (0, 5, 10, 15, 30, 45, and 60 min) on the physico-chemical properties of pork M. longissimus dorsi were evaluated. The pH value was affected by both pressure level and pressurized time, especially at 200 MPa (P<0.05). In color measurement, $L^*$ and $a^*$-values were increased by both pressure level and pressurized time, but $b^*$-value did not differ significantly (P>0.05). Water holding capacity (WHC) was significantly decreased (P<0.05) depending on pressure level and pressurized time, while cooking loss was gradually increased. Warner-Bratzler shear force did not differ significantly (P>0.05) among the treatments. These results indicate that high pressure processing below 200 MPa for 1 hr had no effect on the quality of cooked meat, although some alterations were observed before cooking.

외이경혈 미세전류신경근 자극과 체성경혈 미세전류신경근 자극이 압통역치에 미치는 효과 (Effects of Microcurrent Electrical Neuromuscular Stimulation of Auricular and Somatic Acupuncture Points on Experimental Pressure Threshold)

  • 고현철;조원호;한승수
    • 한국전문물리치료학회지
    • /
    • 제4권2호
    • /
    • pp.36-50
    • /
    • 1997
  • The purpose of this study was to compare the effects of high intensity, high frequency microcurrent electrical neuromuscular stimulation(MENS) of auricular and somatic acupuncture points and low intensity, low frequency microcurrent electrical neuromuscular stimulation(MENS) of auricular and somatic acupuncture points on experimental pressure threshold at the elbow according to the time. Fifty healthy adults, aged 19 to 26 years, were assigned randomly to one of five groups: 1) the high intensity, high frequency somatic group(n=10) received MENS to somatic acupuncture points, 2) the high intensity, high frequency auricular group(n=10) received MENS to auricular acupuncture points, 3) the low intensity, low frequency somatic group(n=10) received MENS to somatic acupuncture points, 4) the low intensity, low frequency somatic group(n=10) receive MENS to somatic acupuncture points, and 5) the placebo group(n=10) received placebo treatment and served as controls. Pressure threshold was measured before, after, 5 minutes, 10 minutes and 15 minutes. Pressure threshold has increased significantly(p<.05) in the high intensity, high frequency auricular group following treatment after 5 minutes, with no statistically significant differences in pressure threshold change scores among five groups, Only the high intensity, high frequency auricular group demonstrated statistically significant change score in pressure threshold following treatment after, 5 minutes, 10 minutes and 15 minutes after compared to the placebo group. The results indicated that MENS applied to the high intensity, high frequency auricular group increases pressure threshold.

  • PDF

실제기체 효과를 고려한 수소기체의 임계노즐 유동에 관한 연구 (Study on the Critical Nozzle Flow of Hydrogen Gas with Real Gas Effects)

  • 김재형;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3003-3008
    • /
    • 2007
  • Critical nozzle has been frequently employed to measure the flow rate of various gases, but hydrogen gas, especially being at high-pressure condition, was not nearly dealt with the critical nozzle due to treatment danger. According to a few experimental data obtained recently, it was reported that the discharge coefficient of hydrogen gas through the critical nozzle exceeds unity in a specific range of Reynolds number. No detailed explanation on such an unreasonable value was made, but it was vaguely inferred as real gas effects. For the purpose of practical use of high-pressure hydrogen gas, systematic research is required to clarify the critical nozzle flow of high-pressure hydrogen gas. In the present study, a computational fluid dynamics(CFD) method has been applied to predict the critical nozzle flow of high-pressure hydrogen gas. Redlich-Kwong equation of state that take account for the forces and volume of molecules of hydrogen gas were incorporated into the axisymmetric, compressible Navier-Stokes equations. A fully implicit finite volume scheme was used to numerically solve the governing equations. The computational results were validated with some experimental data available. The results show that the coefficient of discharge coefficient is mainly influenced by the compressibility factor and the specific heat ratio, which appear more remarkable as the inlet total pressure of hydrogen gas increases.

  • PDF

고압실 형상에 따른 환형 제트펌프의 특성 (The Effect of High Pressure Chamber's Shape on the Characteristics of Annular Jet Pump)

  • 권오붕
    • 수산해양기술연구
    • /
    • 제35권4호
    • /
    • pp.428-434
    • /
    • 1999
  • Experimental studies on the characteristics of annular jet pump were carried out in this paper. Jet pump can be used widely for the transportation of solid materials, farm produce and fishes. The effects of high pressure chamber on the characteristics of annular jet pump were sought in this paper. Experiments were done for three shapes of high pressure chamber, and for several lengths of the high pressure chamber. Three types of the high pressure chamber's entrances($90^{\circ}$ single inflow, $45^{\circ}$single inflow, and $45^{\circ}$ double inflow) were tested. Water was used for both the primary fluid and secondary fluid. The results obtained in this study are as follows; $45^{\circ}$double inflow type is the most effective among the tested three types of the high pressure chamber's entrances. The efficiency of jet pump with 400mm of high pressure chamber length is the highest among the chamber lengths tested in this study, thus indicating appropriate chamber length is required to get an efficient.

  • PDF

고압실 형상에 따른 환형 제트펌프의 특성 (The Effect of High Pressure Chamber's Shape on the Characteristics of Annular Jet Pump)

  • 김명관;권오붕
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.75-81
    • /
    • 2000
  • Experimental studies on the characteristics of annular jet pump were carried out in this paper. The effects of high pressure chamber on the characteristics of annular jet pump were sought in this paper. Experiments were done for three shapes of high pressure chamber, and for several lengths of the high pressure chamber. Three types of the high pressure chamber's entrances($90^{\circ}$ single inflow, $45^{\circ}$ single inflow, and $45^{\circ}$ double inflow) were tested. Water was used for both the primary fluid and secondary fluid. The results obtained in this study are as follows; $45^{\circ}$ double inflow type is the most effective among the tested three types of the high pressure chamber's entrances. The efficiency of jet pump with 400mm of high pressure chamber length is the highest among the chamber lengths tested in this study, thus indicating appropriate chamber length is required to get an efficient jet pump.

  • PDF

Thermal-pressure loading effect on containment structure

  • Kwak, Hyo-Gyoung;Kwon, Yangsu
    • Structural Engineering and Mechanics
    • /
    • 제50권5호
    • /
    • pp.617-633
    • /
    • 2014
  • Because the elevated temperature degrades the mechanical properties of materials used in containments, the global behavior of containments subjected to the internal pressure under high temperature is remarkably different from that subjected to the internal pressure only. This paper concentrates on the nonlinear finite element analyses of the nuclear power plant containment structures, and the importance for the consideration of the elevated temperature effect has been emphasized because severe accident usually accompanies internal high pressure together with a high temperature increase. In addition to the consideration of nonlinear effects in the containment structure such as the tension stiffening and bond-slip effects, the change in material properties under elevated temperature is also taken into account. This paper, accordingly, focuses on the three-dimensional nonlinear analyses with thermal effects. Upon the comparison of experiment data with numerical results for the SNL 1/4 PCCV tested by internal pressure only, three-dimensional analyses for the same structure have been performed by considering internal pressure and temperature loadings designed for two kinds of severe accidents of Saturated Station Condition (SSC) and Station Black-out Scenario (SBO). Through the difference in the structural behavior of containment structures according to the addition of temperature loading, the importance of elevated temperature effect on the ultimate resisting capacity of PCCV has been emphasized.

Effects of High Hydrostatic Pressure on Technical Functional Properties of Edible Insect Protein

  • Kim, Tae-Kyung;Yong, Hae In;Kang, Min-Cheol;Jung, Samooel;Jang, Hae Won;Choi, Yun-Sang
    • 한국축산식품학회지
    • /
    • 제41권2호
    • /
    • pp.185-195
    • /
    • 2021
  • The objective of this study was to determine the effects of high pressure to investigate the technical functional properties of the protein solution extracted from an edible insect, Protaetia brevitarsis seulensis. High pressure processing was performed at 0 (control), 100, 200, 300, 400, and 500 MPa at 35℃. The essential amino acid index of the control was lower (p<0.05) than that of the P. brevitarsis seulensis extract treated with 100 MPa. The SDS-PAGE patterns tended to become faint at approximately 75 kDa and thicker at approximately 37 KDa after high pressure treatment. The protein solubility and pH of the protein tended to increase as the hydrostatic pressure levels increased. The instrument color values (redness and yellowness) of the P. brevitarsis seulensis protein treated with high pressure were lower (p<0.05) than those of the control. The forming capacity of the protein solution with P. brevitarsis seulensis treated with high pressure was higher (p<0.05) than that of the control. In conclusion, we confirmed that the technical functional properties of edible insect proteins extracted under high pressure of 200 MPa are improved. Our results indicate that high pressure can improve the technical functional properties of proteins from edible insects.

저압 에어포그 시스템을 설치한 온실의 냉방효율 (Cooling Efficiency of Low Pressure Compressed Air Fogging System in Naturally Ventilated Greenhouses)

  • 남상운;김영식;성인모;고기혁
    • 한국농공학회논문집
    • /
    • 제54권5호
    • /
    • pp.49-55
    • /
    • 2012
  • In order to derive the efficient utilization of low pressure compressed air fogging system, cooling efficiencies with control types were analyzed through cooling experiments in tomato greenhouses. The control types were set up with temperature control, humidity control, temperature and humidity control, and time control. It showed that the cooling effects were 0.7 to $3.3^{\circ}C$ on average and maximum of 4.3 to $7.0^{\circ}C$, the humidification effects were 3.5 to 13.5 % on average and maximum of 14.3 to 24.4 %. Both the cooling and humidification effect were the highest in the time control method. The cooling efficiency of the air fogging system was not high with 8.3 to 27.3 % on average. However, the cooling efficiency of 24.6 to 27.3 % which appears from the time control is similar to the cooling efficiency of high pressure fogging system experimented in Japan. The air fogging system is operated by low pressure, but its efficiency is similar to high pressure. We think because it uses compressed air. From this point of view, we suggest that the air fogging system can get the cooling efficiency of similar levels to that of high pressure fogging system and it will have an advantage from clogging problem of nozzle etc.

Effects of Key Operating Parameters on the Efficiency of Two Types of PEM Fuel Cell Systems (High-Pressure and Low-Pressure Operating) for Automotive Applications

  • Kim Han-Sang;Lee Dong-Hun;Min Kyoungdoug;Kim Minsoo
    • Journal of Mechanical Science and Technology
    • /
    • 제19권4호
    • /
    • pp.1018-1026
    • /
    • 2005
  • The proton exchange membrane (PEM) fuel cell system consisting of stack and balance of plant (BOP) was modeled in a MATLAB/Simulink environment. High-pressure operating (compressor type) and low-pressure operating (air blower type) fuel cell systems were con­sidered. The effects of two main operating parameters (humidity and the pressure of the supplied gas) on the power distribution characteristics of BOP and the net system efficiency of the two systems mentioned above were compared and discussed. The simulation determines an optimum condition regarding parameters such as the cathode air pressure and the relative humidity for maximum net system efficiency for the operating fuel cell systems. This study contributes to get a basic insight into the fuel cell stack and BOP component sizing. Further research using muli­object variable optimization packages and the approach developed by this study can effectively contribute to an operating strategy for the practical use of fuel cell systems for vehicles.