• Title/Summary/Keyword: high-pressure

Search Result 13,918, Processing Time 0.049 seconds

Study on the Measurement of Safety of a High Pressure Vessel (고압용기(高壓容器)의 안전도(安全度) 측정(測定)에 관(關)한 연구(硏究))

  • Yim, Tong-Kyu;Choi, Man-Yong;Han, Eung-Kyo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.2 no.2
    • /
    • pp.9-16
    • /
    • 1983
  • There are two weak points in a high pressure vessel, one is a corner, the other is a crack on the base. In order to evaluate safety of a department of a corner and a crack like a starfish on the base in a high pressure vessel (working pressure: $130kg/cm^{2}$), which was made by Marison's Process, we analyzed stress by strain gauge, measured thickness and hardness by ultrasonic testing, and were able to test pressure by water pressure from nondestructive testing. Also destructive testings were applied to measure thickness and to observe microstructure and chemical composition of a corner on the base. From the results of the experiment, values of experiment were satisfied with a condition of application. But, it is considered that a crack on the base is to be investigated with more by Fracture Mechanics.

  • PDF

A Study on the Temperature Behavior of Impinging Plate in Impinging Spray with Ultra High pressure (극초고압 충돌분무시 충돌면의 온도거동에 관한 연구)

  • Jeong, Dae-Yong;Kim, Hong-Jun;Lee, Jong-Tai
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.442-447
    • /
    • 2003
  • The characteristics of instantaneous wall-surface temperature of impinging plate in case of ultra high pressure injection have been measured and analyzed by using thin film instantaneous temperature probe and ultra high pressure injection equipment. The decreasing rate of temperature was greater in case of higher temperature of impinging plate. Temperature drop was largest at center of piston and it was slight for others. Instantaneous temperature decreases rapidly with increasing injection pressure. But above 2,500bar of injection pressure, the decreasing rates are slightly affected by increasing injection pressure.

  • PDF

Characteristics of polycrystalline 3C-SiC micro pressure sensors for high temperature applications (초고온용 다결정 3C-SiC 마이크로 압력센서의 특성)

  • Thien, Duong Xuan;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.387-388
    • /
    • 2008
  • High temperature micro pressure sensors were fabricated by polycrystalline (poly) 3C-SiC piezoresistors formed by oxidized SOI substrates with APCVD. These have been designed by bulk micromachining below $1{\times}1mm^2$ diaphragm and Si membrane $20{\mu}m$ thick. The pressure sensitivity of fabricated pressure sensor was 0.1 mV/Vbar. The non-linearity of sensor was ${\pm}0.44%$ FS and the hysteresis was 0.61% FS.TCS of pressure sensor was -1867 ppm/$^{\circ}C$, its TCR was -792 ppm/$^{\circ}C$, and TCGF to 5 bar was -1042 ppm/$^{\circ}C$ from 25 to $400^{\circ}C$.

  • PDF

Effect of Organic Additive Composition on Isostatic Thermocompression Behavior of Alumina Tapes (유기물 조성에 따른 알루미나 테이프의 열간 가압 거동)

  • 이명현;박일석;김대준;이득용
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.8
    • /
    • pp.824-831
    • /
    • 2000
  • Alumina tapes, having various ratios of alumina to alumina+binder+plasticizer (a/(a+o)) and binder to binder+plasticizer(b/(b+p)), were prepared by the tape casting method. The tapes were thermocompressed varying the thermocompression parameters such as temperature, pressure, and duration time. Among the parameters, the pressure was the most influential to the tape packing density. The packing density varied in two different ways depending on the a/(a+o) ratio. For the tapes having low a/(a+o) ratio, a saturation density was reached by applying very a low pressure of 1 MPa. For tapes with high a/(a+o), on the contrary, the saturation density was obtained at a relatively high pressure. These different responses to the pressure are attributed to the fact that the rearrangement of alumina particles by the pressure becomes easy as an organic content in the tapes is high.

  • PDF

Measurement of Laminar Flame Speeds of Dimethyl Ether-Air Mixtures at High Pressure (고압에서 DME-Air 혼합기의 화염속도 측정)

  • Lee, Su Gak;Lee, Ki Yong
    • Journal of the Korean Society of Combustion
    • /
    • v.19 no.1
    • /
    • pp.11-16
    • /
    • 2014
  • Spherically expanding flames are used to measure flame speeds, which are derived the corresponding laminar flame speeds at zero stretch. Dimethyl Ether-Air mixtures at high pressure are studied over an extensive range of equivalence ratios. The classical shadowgraph technique is used to detect the reaction zone. In analytical methodology the optimization process using least mean squares is performed to extract the laminar flame speeds. It is seen that the laminar flame speed of DME-Air mixture with the increase of pressure decreases rapidly showing a similar trend to other hydrocarbon fuels. At pressure of 2 and 10 atm the experimental data from the present study agree well with results reported in the literature. Especially the laminar flame speeds at 2 atm are in good agreement with those calculated in numerical work over the full stoichiometric range. At elevated pressure of 12 atm the measured data are slightly slower at fuel lean condition and show close agreement at fuel rich condition when compared with the numerical results.

A structural analysis of deep depth injection mold to investigate the cause of crack (깊이가 깊은 사출금형의 크랙 원인 파악을 위한 강도해석)

  • Choi, S.H.;Lyu, M.Y.;Kim, D.W.;Kim, S.Y.;Shin, K.S.;Kim, K.Y.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.297-300
    • /
    • 2008
  • High pressure is involved during injection molding operation specially packing phase. Cracks in the mold are often occurred by high cavity pressure. In this study, structural analysis of mold has been performed using commercial softwares, Abaqus and Ansys, to investigate cause of crack in the injection mold. Structural analysis contains four cases: stress distribution according to the cavity pressure, stress concentration according to the boundary conditions, stress concentration for inter-locking design of mold, and stress concentration for distributed cavity pressure. Through this study it was observed that the locations of stress concentrations were coincident with locations of crack. Robust mold design is being required to withstand high cavity pressure.

  • PDF

Spray Distribution Measurement at High Ambient Pressure (고압 환경 하에서의 분무 분포 측정)

  • Cho, Seong-Ho;Im, Ji-Hyuk;Yoon, Young-Bin;Choi, Seong-Man;Han, Young-Min
    • Journal of the Korean Society of Visualization
    • /
    • v.6 no.1
    • /
    • pp.59-65
    • /
    • 2008
  • Distribution of spray was measured. Optical Line Patternator (OLP) was used to measure the planar distribution of the spray from a swirl-coaxial type injector. Ambient pressure was varied and injection pressure was fixed in experiment. As ambient pressure increased, spray distribution was changed from hallow cone to solid cone shape, and spray angle was decreased. Limitation in measuring dense spray was found at high ambient pressure condition.

Deflection prediction of inflatable flat panels under arbitrary conditions

  • Mohebpour, S.R.
    • Structural Engineering and Mechanics
    • /
    • v.45 no.6
    • /
    • pp.853-865
    • /
    • 2013
  • Inflatable panels made of modern and new textile materials can be inflated at high pressure to have a high mechanical strength. This paper is based on the finite element method as a general solution to determine the characteristics of deformed inflatable panels at high pressure in various end and loading conditions. Proposed method is based on the construction of weak form of formulation and application of Reduced Integration Element method (RIE) to solve the numerical problem of shear locking. The numerical results are validated as an outcome of comparison with other published results.

An Experimental Study of Nano PM Emission Characteristics of Commercial Diesel Engine with Urea-SCR System to Meet EURO-IV (상용디젤엔진의 EURO-IV 배기규제 대응을 위한 Urea-SCR 시스템의 나노입자 배출특성에 관한 실험적 연구)

  • Lee, Chun-Hwan;Cho, Taik-Dong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.6
    • /
    • pp.128-136
    • /
    • 2007
  • It is well known that two representative methods satisfy EURO-IV regulation from EURO-III. The first method is to achieve the regulation through the reduction of NOx in an engine by utilizing relatively high EGR rate and the elimination of subsequently increased PM by DPF. However, it results in the deterioration of fuel economy due to relatively high EGR rate. The second is to use the high combustion strategy to reduce PM emission by high oxidation rate and trap the high NOx emissions with DeNOx catalysts such as Urea-SCR. While it has good fuel economy relative to the first method mentioned above, its infrastructure is demanded. In this paper, the number distribution of nano PM has been evaluated by Electrical Low Pressure Impactor(ELPI) and CPC in case of Urea-SCR system in second method. From the results, the particle number was increased slightly in proportion to the amount of urea injection on Fine Particle Region, whether AOC is used or not. Especially, in case of different urea injection pressure, the trends of increasing was distinguished from low and high injection pressure. As low injection pressure, the particle number was increased largely in accordance with the amount of injected urea solution on Fine Particle Region. But Nano Particle Region was not. The other side, in case of high pressure, increasing rate of particle number was larger than low pressure injection on Nano Particle Region. From the results, the reason of particle number increase due to urea injection is supposed that new products are composited from HCNO, sulfate, NH3 on urea decomposition process.

Effect of Immune Activity on Berberis koreana Palibin by Ultra High Pressure Low Temperature Process (초고압 저온처리에 의한 매자나무의 면역 활성)

  • Jin, Ling;Han, Jae-Gun;Ha, Ji-Hye;Jeong, Hyang-Suk;Kwon, Min-Chul;Ahn, Ju-Hee;Kim, Jin-Chul;Choi, Geun-Pyo;Chung, Eul-Kwon;Lee, Hyeon-Yong
    • Korean Journal of Medicinal Crop Science
    • /
    • v.16 no.6
    • /
    • pp.439-445
    • /
    • 2008
  • This study was performed to investigate a methodology of improving immune activities of Berberis koreana Palibin by ultra high pressure on low temperature extraction process. Extraction yield was enhanced up to more than 35% by above process, compare to the control and extraction average. The cytotoxicity on human kidney cell (HEK293) was showed below 20.4%, 21.6% in adding 1.0 mg/ml of the highest concentration. Generally, the extracts by ultra high pressure extraction process showed less toxicity about 5% than the other processes. It could tell that toxic materials that existing in the plant could be reduced or broken by ultra high pressure process due to can be broken bond such the hydrogen bond, the electrostatic bond, the van der Waals bond, and the hydrophobic bond, can be broken by high pressure. The result could be employed to develop a new type of functional food from B. koreana Palibin by low temperature high pressure process.