• Title/Summary/Keyword: high-frequency effects

Search Result 1,806, Processing Time 0.036 seconds

Immediate Effects of High-frequency Diathermy on Muscle Architecture and Flexibility in Subjects With Gastrocnemius Tightness

  • Kim, Ji-hyun;Park, Joo-hee;Yoon, Hyeo-bin;Lee, Jun-hyeok;Jeon, Hye-seon
    • Physical Therapy Korea
    • /
    • v.27 no.2
    • /
    • pp.133-139
    • /
    • 2020
  • Background: The gastrocnemius (GCM) is one of the lower extremity muscles that tend to tighten easily. GCM tightness results in limited ankle dorsi-flexion (DF), especially when the knee joint is fully extended. Joint flexibility is determined by the morphological and physiological characteristics of joints, muscles, tendons, and ligaments. Impaired joint flexibility can be attributed to increased susceptibility to muscle injury. High-frequency diathermy is clinically used to reduce pain and muscle tightness and to improve limited range of motion. Objects: This study aimed to investigate the immediate effects of high-frequency therapy in subjects with GCM tightness. Methods: The study was designed as a one-group before-after trial. The subjects included 28 volunteers with GCM tightness (an active ankle DF angle of less than 12°) without any known neurological and musculoskeletal pathologies in the ankle and calf areas. WINBACK Transfer Electrode Capacitive and Resistive Therapy equipment was used to apply high-frequency therapy to the subjects' GCMs for 10-15 minutes. The pennation angle and the fascicle length of the GCM were measured using ultrasonography. The flexibility of the ankle joint, peak torque to the passive ankle DF (Biodex), and soft tissue stiffness (MyotonPRO) were also measured. Results: The pennation angle was significantly decreased following the treatment; however, no significant difference in the fascicle length was found (p < 0.05). The flexibility was significantly increased and both the passive peak torque to passive ankle DF and the soft tissue stiffness significantly decreased (p < 0.05). Conclusion: High-frequency therapy is immediately effective for improving the muscle's architectural properties and functional factors in subjects with GCM tightness. Further longitudinal clinical studies are required to investigate the long-term effects of high-frequency therapy on subjects with GCM tightness from various causes.

The Relative Effects of Feedback Frequency and Specificity of Eco-IVIS on Fuel Efficiency and Workload (에코 드라이빙 피드백 제공 빈도와 구체성이 연비와 작업부하에 미치는 효과)

  • Lee, Kyehoon;Cho, Hangsoo;Oah, Shezeen;Moon, Kwangsu
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.132-138
    • /
    • 2015
  • This study examined the relative effects of feedback frequency and specificity of Eco-IVIS(eco in-vehicle information system) on the fuel-efficiency and workload. Eighty participants randomly assigned into four experimental groups (high frequency/specific, high frequency/global, low frequency/specific, and low frequency/global feedback) and they drove 16.4Km motorway under the each feedback condition. The dependent variable were fuel efficiency and Drive Activity Load Index which measured participants' subjective ratings of driving workload. The results showed that high frequent feedback was more effective for increasing fuel-efficiency than low frequent feedback, however, there was no significant difference of fuel-efficiency between specific and global feedback. Although, overall DALI score was comparable among four experimental conditions, visual demand score was significant higher under the high frequent feedback condition than low frequent feedback.

Corrosion Fatigue Cracking of Low Alloy Steel in High Temperature Water

  • Lee, S.G.;Kim, I.S.;Jang, C.H.;Jeong, I.S.
    • Corrosion Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.93-97
    • /
    • 2003
  • Fatigue crack growth test or low alloy steel was performed in high temperature water. Test parameters were dissolved oxygen content. loading frequency and R-ratio ($P_{min}/P_{max}$). Since the sulfur content or the steel was low, there were no environmentally assisted cracks (EAC) in low dissolved oxygen(DO) water. At high DO, the crack growth rate at R = 0.5 tests was much increased due to environmental effects and the crack growth rate depended on loading frequency and maximized at a critical frequency. On the other hand, R = 0.7 test results showed an anomalous decrease of the crack growth rate as much different behavior from the R = 0.5. The main reason of the decrease may be related to the crack tip closure effect. All the data could be qualitatively understood by effects of oxide rupture and anion activity at crack tip.

Effects of the Insulation Quality on the Frequency Response of Power Transformers

  • Abeywickrama Nilanga;Ekanayake Chandima;Serdyuk Yuriy V.;Gubanski Stanislaw M.
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.4
    • /
    • pp.534-542
    • /
    • 2006
  • This paper presents results of frequency domain spectroscopy (FDS) measurements on oil-impregnated pressboard insulation, their analyses and use of the data for modeling high frequency response (FRA) of transformers. The dielectric responses were measured in a broad frequency range, i.e. from 0.1 mHz to 1 MHz, on model samples containing different amount of moisture. The responses were parameterized with terms representing dc conductivity, low frequency dispersion and Cole-Cole polarization mechanisms and they were thereafter used to model the FRA response of a three-phase transformer.

High Frequency Model of Inverter-fed Induction Motor (인버터 구동 유도 전동기 고주파 모델링)

  • Hong, Sun-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.795-797
    • /
    • 2001
  • Voltage varing Fate dv/dt which is applied to induction motor usually makes unnegligible leakage current and it flows through stator winding and motor frame. This kind of harmonic leakage current makes effect on power source and cuases electromagnetic trouble because the motor frame has earth. Therefore in this study, a high frequency induction motor model is developed and analyze the motor performance to explain the phenomena. Inverter model is also developed and is combined with the motel model to prepare the basis of the high frequency effects on inverter fed induction motor.

  • PDF

The analgesic effect of combined electroacupuncture at Hoku (LI4) and Zusanli (ST36) using TFL (합곡혈(合谷穴)과 족삼리혈(足三里穴) 병용자극(倂用刺戟)이 TEL에 미치는 영향)

  • Baek, Kyong-Won;Ko, Eun-Sang;Min, Byung-Il;Park, Dong-Suk
    • Journal of Acupuncture Research
    • /
    • v.18 no.1
    • /
    • pp.76-87
    • /
    • 2001
  • Objective : Zusanli(ST36) and Hoku(Li4) are analgesic acupuncture points frequently used for acupuncture in Oriental medicine. The present study was conducted to see the antinociceptive effects produced by electroacupuncture combined two frequencies(Low, High) and two different acupuncture points(LI4, ST36) in the rat tail flick test. Method : In this study the Rats (Sprague-Dawley, 250-300g) were partially anesthetized with thiopental sodium(40mg/kg, i.p.). The basal reaction time for the tail-flick was 3${\pm}$0.5 sec. Low frequency(3Hz, 5V, biphasic) and high frequency(100Hz, 5V, biphasic) were applied to the inserted needle for the period of insertion(twenty minutes). Experimental groups are divied as follow; a) electroacupuncture stimulation groups at Hoku with or high frequency(L-EA, H-EA), b) electroacupuncture stimulation groups at Zusanli with low or high frequency(1-EA, h-EA), c) low frequency at Hoku and Zusanli(LIEA), d) low frequency at Hoku and high frequency at Zusanli(LhEA), e) high frequency at Hoku and low frequency at Zusanli(HIEA), f) high frequency at Hoku and Zusanli(HhEA) Results : The individual stimulation at either Hoku or Zusanli with low frequency has stronger and longer analgesic effect than high frequency stimulation. In addition, the combined stimulation at Hoku and Zusanli with low frequency has superior effect to individual stimulation with low frequency. LhEA and LIEA have superior effect to other stimulation groups among the combined groups. In order to determine the involvement of opioid system on the different antinociceptive effects, Naloxone, an opioid antagonist, was used in the combined groups. LIEA is the most sensitive when naloxone was administrated among study groups. HhEA is the least sensitive in the administration of naloxone. Conclusion : From results, this study confirmed that the opioid system is involved in analgesic effect of low frequency stimulation of acupuncture point, and we also can suggest the stronger analgesic effect of combining stimulation points is due to the theory of spatial summation in the nervous system.

  • PDF

Increasing injection frequency enhances the survival of injected bone marrow derived mesenchymal stem cells in a critical limb ischemia animal model

  • Kang, Woong Chol;Oh, Pyung Chun;Lee, Kyounghoon;Ahn, Taehoon;Byun, Kyunghee
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.20 no.6
    • /
    • pp.657-667
    • /
    • 2016
  • Critical limb ischemia (CLI) is one of the most severe forms of peripheral artery diseases, but current treatment strategies do not guarantee complete recovery of vascular blood flow or reduce the risk of mortality. Recently, human bone marrow derived mesenchymal stem cells (MSCs) have been reported to have a paracrine influence on angiogenesis in several ischemic diseases. However, little evidence is available regarding optimal cell doses and injection frequencies. Thus, the authors undertook this study to investigate the effects of cell dose and injection frequency on cell survival and paracrine effects. MSCs were injected at $10^6$ or $10^5$ per injection (high and low doses) either once (single injection) or once in two consecutive weeks (double injection) into ischemic legs. Mice were sacrificed 4 weeks after first injection. Angiogenic effects were confirmed in vitro and in vivo, and M2 macrophage infiltration into ischemic tissues and rates of limb salvage were documented. MSCs were found to induce angiogenesis through a paracrine effect in vitro, and were found to survive in ischemic muscle for up to 4 weeks dependent on cell dose and injection frequency. In addition, double high dose and low dose of MSC injections increased vessel formation, and decreased fibrosis volumes and apoptotic cell numbers, whereas a single high dose did not. Our results showed MSCs protect against ischemic injury in a paracrine manner, and suggest that increasing injection frequency is more important than MSC dosage for the treatment CLI.

Nondestructive Evaluation for Long-term Heat Treatment Effects on Microstructure of Co-base Superalloy by Scanning Acoustic Microscope (주사음향현미경을 이용한 코발트기 초내열합금 미세조직에 관한 장시간 열영향에 대한 비파괴평가)

  • lEE, JoonHee;Kim, ChungSeok
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.32 no.3
    • /
    • pp.118-123
    • /
    • 2019
  • The aim of this study investigates the feasibility of scanning acoustic microscope (SAM) with high frequency transducer for material degradation. The test specimen was prepared by artificial heat treatment of Co-base superalloy. The high frequency 200 MHz acoustic lens was used to generate the leaky surface acoustic wave (LSAW) on the test specimens. The matrix precipitates coarsened with thermal aging time, and then grow up to several tens of micrometers. The velocity of LSAW decreased with increasing aging time. Also, it has a good correlation between LSAW and hardness. Consequently, V(z) curve methods of SAM using high frequency transducer is useful tool to evaluate the heat treatment effects on microstructure.

Characterization of high performance CNT-based TSV for high-frequency RF applications

  • Kannan, Sukeshwar;Kim, Bruce;Gupta, Anurag;Noh, Seok-Ho;Li, Li
    • Advances in materials Research
    • /
    • v.1 no.1
    • /
    • pp.37-49
    • /
    • 2012
  • In this paper, we present modeling and characterization of CNT-based TSVs to be used in high-frequency RF applications. We have developed an integrated model of CNT-based TSVs by incorporating the quantum confinement effects of CNTs with the kinetic inductance phenomenon at high frequencies. Substrate parasitics have been appropriately modeled as a monolithic microwave capacitor with the resonant line technique using a two-polynomial equation. Different parametric variations in the model have been outlined as case studies. Furthermore, electrical performance and signal integrity analysis on different cases have been used to determine the optimized configuration for CNT-based TSVs for high frequency RF applications.

A Study on the Design of High-Frequency Jet Ventilator Using PLL system (위상동기루프 방식을 이용한 고빈도 JET환기장치의 설계에 관한 연구)

  • Lee, Joon-Ha;Chung, Jae-Chun
    • Journal of Yeungnam Medical Science
    • /
    • v.6 no.2
    • /
    • pp.63-70
    • /
    • 1989
  • This paper describes to design and to examine the mechanical characteristics of high frequency jet ventilator. The device consists of Phase lock loop(PLL) system, solenoid valve driving control part and Air regulating system. This study is carried out by changing several factors such as endotracheal tube(E.T. tube)diameter, injector cannula diameter, 1%, and frequency(breaths/mim.) having direct effects on the gas exchange as well as parameters of the entrained gas by venturi effects, so as to measure the tidal volume and minute volume. This system characteristics were as follows : 1) Frequency : 6-594bpm 2) Inspiration time : 1-99% 3) Variance of input air pressure : 1-30PSI.

  • PDF