• Title/Summary/Keyword: high-$T_c$ dc SQUID

Search Result 8, Processing Time 0.017 seconds

Fabrications and measurements of single layer YBCO dc-SQUID magnetometers designed with parallel-loop pickup coil (Parallel-loop 검출코일을 가지는 단일층 YBCO dc-SQUID 자력계의 제작 및 특성 연구)

  • 유권규;김인선;박용기
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.45-49
    • /
    • 2003
  • We have designed and fabricated the single-layer high $T_{c}$ SQUID magnetometer consisting of a directly coupled grain boundary junction SQUID with an inductance of 100 pH and 16 nested parallel pickup coils with the outermost dimension of 8.8 mm ${\times}$ 8.8 mm. The magnetometer was formed from a YBCO thin film deposited on an STO(100) bicrystal substrate with a misorientation angle of $30^{\circ}$. The SQUID magnetometer was further improved by optimizing the multi-loop pickup coil design for use in unshielded environments. Typical characteristics of the dc SQUID magnetometer had a modulation voltage of 40 $\mu\textrm{V}$ and a white noise of $30fT/Hz^{1}$2/. The SQUID magnetometer exhibited a 1/f noise level at 10 Hz reduced by a factor of about 3 compared with that of the conventional solid type pickup coil magnetometers and a very stable flux locked loop operation in magnetically disturbed environments.s.

  • PDF

Construction of a 40-channel SQUID System and Its Application to Neuromagnetic Measurements

  • Lee, Y.H.;Kim, J.M.;Kwon, H.C.;Park, Y.K.;Park, J.C.;Lee, D.H.;Ahn, C.B.
    • Progress in Superconductivity
    • /
    • v.2 no.1
    • /
    • pp.20-26
    • /
    • 2000
  • A 40-channel superconducting quantum interference device (SQUID) system was constructed for measuring neuromagnetic fields. Main features of the system are the use of double relaxation oscillation SQUIDs (DROSs), and planar gradiometers measuring magnetic field components tangential to the head surface. The DROSs with high flux-to-voltage transfers enabled direct readout of the SQUID output by room-temperature dc preamplifiers and simple flux-locked loop circuits could be used for SQUID operation. The pickup coil is an integrated first-order planar gradiometer with a baseline of 40 mm. Average noise level of the 40 channels is around 1.2 $fT/cm/{\surd}Hz$ at 100 Hz, corresponding to a field noise of 5 $fT/{\surd}Hz$, operated inside a magnetically shielded room. The SQUID insert was designed to have low thermal load, minimizing the loss of liquid helium. The constructed system was applied to measure auditory-evoked neuromagnetic fields.

  • PDF

High sensitive SQUID sensor on YBCO thin film (YBCO 박막을 이용한 고감도 SQUID 센서)

  • ;;K.NM. Yugay;A.B. Muravjev;K.K. Yugay;G.M.Serojan;A.S.Sjichev
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.758-761
    • /
    • 2003
  • The goal of the research is to study and describe a new stressed state of High Temperature Superconducting (High-T$_{c}$) YBCO Films, to create of SQUIDs (Superconducting Quantum Interference Device) on the bases of these films with maximal sensitivity. With the experimental investigation of the stressed films grown by laser ablation method and its properties, the fabrication of the dc-SQUIDs with maximal sensitivity on the bases of the stressed YBCO films were carried out. The stressed film having the value of the critical current density J$_{c}$=3ㆍ$10^{5}$A/$\textrm{cm}^2$ was the more stable than others.ers.s.

  • PDF

Fabrication of sing1e layer $d^2B_{z}$/dxdy second-order SQUID gradiometer (단일층 $d^2B_{z}$/dxdy SQUID 2차 미분기 설계 및 제작)

  • 황윤석;박승문;이순걸;김인선;박용기
    • Progress in Superconductivity
    • /
    • v.4 no.2
    • /
    • pp.109-113
    • /
    • 2003
  • We have developed a planar-type single layer second-order $high-T_{c}$ SQUID gradiometer, which can detect the $d^2$$B_{z/}$dxdy of the second-order field gradient. This SQUID gradiometer consists of four-way 'clover-leaf' pick-up loops and is coupled directly to a 4-junction dc SQUID in such a way that the coupling polarity of the two diagonal loops is opposite to that of the other two loops. The pickup loops are intrinsically balanced for both uniform field and the 1 st-order field gradient. The $YBa_2$$Cu_3$$O_{7}$ thin film was made by pulsed laser deposition method on $SrTiO_3$ single crystal substrate and patterned by photolithography with Ar ion milling technique. Response of this gradiometer was tested for both uniform field and the 2nd-order field gradient. Details of the design, fabrication, and results will be discussed.

  • PDF

FABRICATION OF HIGH QUALITY YBa$_2$Cu$_3$O$_{y}$ THIN FILMS USING PULSED LASER DEPOSITION

  • Lee, Eun-Hong;Park, Sang-Jin;Song, I-Hun;Song, In-Sang;Gohng, Jun-Ho;Sok, Jung-Hyun;Lee, Jo-Won
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.5
    • /
    • pp.437-442
    • /
    • 1996
  • High quality $YBa_2Cu_3O_y$(YBCO) thin films for directly coupled dc superconducting quantum interference device (SQUID) were fabricated by pulsed laser deposition. Several critical parameters have been optimized through systematic studies. Thus, the films showing the $T_c$ of above 91K and $J_c$ of above$2\times10^6A/cm^2$ at 77K were routinely obtained. Extensive AFM and X-ray diffraction studies have been conducted for morphological and structural analyses. The directly coupled DC-SQUIDs were fabricated from the YBCO thin films deposited on $SrTiO_3$ bicrystals under the optimized conditions. The measurement on $2I_c$ and swing voltage give 200$\mu$A and 17$\mu$V at 77K, respectively.

  • PDF

Noise Characteristics of Readout Electronics for 64-Channel DROS Magnetocardiography System (64채널 DROS 심자도 시스템을 위한 검출 회로의 잡음 특성)

  • Kim J. M.;Kim K. D.;Lee Y. H.;Yu K. K.;Kim K. W.;Kwon H. C.;Sasada Ichiro
    • Progress in Superconductivity
    • /
    • v.7 no.1
    • /
    • pp.46-51
    • /
    • 2005
  • We have developed control electronics to operate flux-locked loop (FLL), and analog signal filters to process FLL outputs for 64-channel Double Relaxation Oscillation SQUID (DROS) magnetocardiography (MCG) system. Control electronics consisting of a preamplifier, an integrator, and a feedback, is compact and low-cost due to larger swing voltage and flux-to-voltage transfer coefficients of DROS than those of dc SQUIDs. Analog signal filter (ASF) serially chained with a high-pass filter having a cut-off frequency of 0.1 Hz, an amplifier having a gain of 100, a low-pass filter of 100 Hz, and a notch filter of 60 Hz makes FLL output suitable for MCG. The noise of a preamplifier in FLL control electronics is $7\;nV/{\surd}\;Hz$ at 1 Hz, $1.5\;nV/{\surd}\;Hz$ at 100 Hz that contributes $6\;fT/{\surd}\;Hz$ at 1 Hz, $1.3\;fT/{\surd}\;Hz$ at 100 Hz in readout electronics, and the noise of ASF electronics is $150\;{\mu}V/{\surd}\;Hz$ equivalent to $0.13\;fT/{\surd}\;Hz$ within the range of $1{\sim}100\;Hz$. When DROSs are connected to readout electronics inside a magnetically shielded room, the noise of 64-channel DROS system is $10\;fT/{\surd}\;Hz$ at 1 Hz, $5\;fT/{\surd}\;Hz$ at 100 Hz on the average, low enough to measure human MCG.

  • PDF