• Title/Summary/Keyword: high volume

Search Result 6,439, Processing Time 0.032 seconds

Effects of Rice Straw as Bulking Materials on Aerobic Composting of Food Wastes (팽화재로서의 볏짚이 음식물쓰레기의 호기성 퇴비화에 미치는 영향)

  • 박석환
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.141-148
    • /
    • 2002
  • This study was performed to examine the effects of rice straw as bulking materials on temperature, pH, weight and volume reduction, porosity, C/N ratio, salinity, and conductivity in aerobic composting of food wastes. Volume ratios of food wastes to rice straw in reactor control, RS-1, RS-2, RS-2 and RS-4 were 4:0, 4:1. 4:2. 4:3 and 4:4, respectively. Reactors were operated for 24days with 1 hour stirring by lrpm and 2hours aeration per day. The values of pH of food wastes and rice straw were 4.39 and 7.4, respectively. The lowering of the volume ratio of food wastes to rice straw resulted in the high reaction temperature and the fast weight and volume reduction rates. C/N ratio in control was larger than that in rice straw containing reactors. Salinity and conductivity in reactors were condensed and increased by reaction days.

A Study on Correlation between A/F and ion signal in a Constant-Volume Chamber Using Spark-plug Ionization Probe Itself (정적챔버에서 스파크 플러그 이온프로브를 이용한 공연비와 이온신호와의 상관관계에 대한 연구)

  • Park, Jong-Il;Chun, Kwang-Min;Hahn, Jae-Won;Park, Chul-Woong
    • 한국연소학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.223-229
    • /
    • 2002
  • Spark plug ionization signal could be useful in an internal combustion engine as a feedback signal for combustion diagnostics such as misfire detection, knocking detection and lambda control, but the signal has high level of cyclic fluctuation in an internal combustion engine due to residual gas, pressure, temperature, mixture composition in the spark gap. Because of this reason it is very difficult to apply ion signal to commercial engine control. In this Study, a correlation between A/F and spark plug ionization signal was studied in a constant volume chamber. Constant volume chamber with gas phase fuel(Propane) has homogeneous fuel composition , no mixture flow, same pressure and temperature on each test. The results show that mean chemi-ion signal has the highest correlation with A/F and intial pressure change has on effect on the thermal-ion signal and not on chemi-ion signal.

  • PDF

An Experimental Study on the Engineering Properties of HPFRCC According to Kinds, Shapes and Volume Fraction of Fibers (섬유의 종류, 형상 및 치환율에 따른 HPFRCC의 공학적 특성에 관한 실험적 연구)

  • 김영덕;조봉석;김재환;김규용;최경렬;김무한
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.59-62
    • /
    • 2003
  • Kinds, shapes and fraction ratios of fibers have influence on properties of HPFRCC(High-Performance Fiver Reinforced Cementitious Concrete ) like bending strength, strain capacity and fracture toughness. For example, hydrophilic fibers have different chemical bond strength from hydrophobic fibers, fiber shapes influence on fiber pull-out and rupture, and fiber volume fraction influence on bending strength. In this study, to estimate influences of kinds, shapes and fraction ratios of fibers, we make HFRCC with 3 kind of fiber in various volume fraction of fiber and compare cracking, bending strength and fracture toughness. As the results, bending strength of HPFRCC was increased as fiber volume fraction was Increase and fiber tensile strength was increase, and strain capacity and fracture toughness of HFRCC was higher in fiber pull-out fracture than in fiber rupture fracture. And HFRCC showing pseudo strain hardening has higher fiber reinforce efficiency than others.

  • PDF

Cost Reduction Design in Single-phase Line-start Permanent Magnet Motor (단상 유도형 동기 전동기의 Cost 저감 설계)

  • Lee, Byeong-Hwa;Nam, Hyuk;Lee, Jeong-Jong;Fang, Liang;Hong, Jung-Pyo;Ha, Seung-Hyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2208-2212
    • /
    • 2008
  • This paper deals with the cost reduction design of a single-phase line-start permanent magnet(LSPM) motor. Due to high cost of the permanent magnet(PM), cost reduction can be effectively achieved by reducing PM volume. Therefore, motor characteristics according to the PM volume are calculated by using d-q axis equivalent circuit analysis, and the characteristic map is made. In the characteristic map, maximum torque and efficiency are shown according to motor parameters such as back electromotive force(back emf) and inductances; back emf represents the PM volume. Minimum back emf and inductances satisfying output performance are determined in the characteristic map. Then, motor geometry based on the prototype motor is optimized to get the determined parameters using response surface methodology(RSM) and finite element method(FEM). Through the presented cost reduction design, total PM volume is reduced to 32% of prototype model.

Spatially multiplexed volume hologram using an optical fiber (광섬유를 이용한 위치 다중화 구조의 체적 홀로그램)

  • 강용훈;김기현;이병호
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.241-244
    • /
    • 1997
  • A speckle pattern from an optical fiber is used for a reference beam in writing and reading a volume hologram. The photorefractive volume hologram with this scheme shows good spatial selectivity for spatial(shift) multiplexing because the speckle pattern in writing and reading a hologram looses correlation with a small spatial shift. This scheme has the insensitivity to axial movement. The data storage system with this scheme will have a high storage density and a good stability in operation. We theoretically analyze the diffracted beam from a volume hologram recorded with the speckle pattern from the optical fiber. Experimental results are presented and compared with numerical analysis.

  • PDF

Areal Distribution of Runoff Volume by Seasonal Watershed Model (계절유역 모형을 사용한 유량의 공간적분포 결정)

  • 선우중
    • Water for future
    • /
    • v.17 no.2
    • /
    • pp.125-131
    • /
    • 1984
  • watershed Model by mathematical formulation is one of the powerful tool to analyze the hydrologic process in a watershed. The seasonal watershed model is one of the mathematial model from which the monthly streamflow can be simulated and forcasted for given precipitaion data. This model also enables us to compute the monthly runoff at each subbgasin when the basin is subdivided into several small subbasins. The computation of runoff volume makes a Prediction of the areal distirbution of runoff volume for a given precipitation data. Several basins in Han River basin were chosen to simulate the monthly runoff and compute the runoff at each subbasin. A simple logarithmic regression were conducted between runoff ratio and area ratio. The correlation was very high and the equation can be used for prediciting flood volume when flood at downstream gaging station is know.

  • PDF

Study on the Volume Fraction Optimization of Functionally Graded Heat-Resisting Composites (기능경사 내열 복합재의 체적분율 최적화에 관한 연구)

  • Jo, Jin-Rae;Ha, Dae-Yul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.6
    • /
    • pp.988-995
    • /
    • 2001
  • Functionally graded materials(FGMs) are highlighted to be suitable for high temperature engineering due to their continuous distribution of material properties. In this paper, an optimal design is executed for determining the optimal material volume distribution pattern that minimizes the steady-state thermal stress of FGM heat-resisting composites. The interior penalty function method and the golden section method are employed as optimization techniques while the finite element method is used for thermal stress analysis. Through numerical simulations we suggest the volume fraction distributions that considerably improve initial thermal stress distributions.

Influence of the microstructure on effective mechanical properties of carbon nanotube composites

  • Drucker, Sven;Wilmers, Jana;Bargmann, Swantje
    • Coupled systems mechanics
    • /
    • v.6 no.1
    • /
    • pp.1-15
    • /
    • 2017
  • Despite the exceptional mechanical properties of individual carbon nanotubes (CNTs), the effective properties of CNT-reinforced composites remain below expectations. The composite's microstructure has been identified as a key factor in explaining this discrepancy. In this contribution, a method for generating representative volume elements of aligned CNT sheets is presented. The model captures material characteristics such as random waviness and entanglement of individual nanotubes. Thus it allows studying microstructural effects on the composite's effective properties. Simulations investigating the strengthening effect of the application of a pre-stretch on the CNTs are carried out and found to be in very good agreement with experimental values. They highlight the importance of the nanotube's waviness and entanglement for the mechanical behavior of the composite. The presented representative volume elements are the first to accurately capture the waviness and entanglement of CNT sheets for realistically high volume fractions.

A Simple Proposition for Improving Industrial Hygiene Air Sampling Methods

  • Paik, Samuel Y.;Zalk, David M.
    • Safety and Health at Work
    • /
    • v.10 no.3
    • /
    • pp.389-392
    • /
    • 2019
  • When conducting an exposure assessment, the primary goal of the industrial hygienist is to fully characterize the worker's exposure during a work shift to compare it with an occupational exposure limit. This applies regardless of the duration of the work activity as an activity that is relatively short in duration can still present exposure in excess of the occupational exposure limit even when normalized over an 8-hr shift. This goal, however, is often impeded by the specification of a minimum sample volume in the published sampling method, which may prevent the sample from being collected or submitted for analysis. Removing the specification of minimum sample volume (or adjusting it from a requirement to a recommendation), in contrast, allows for a broader assessment of jobs that consist of short-duration and high-exposure activities and also eliminates the unnecessary practice of running sampling pumps in clean air to collect a specified, minimum volume.

Distribution Aspects of the wintering Red-crowned Crane and White-naped Crane according to the Anthropogenic Factors in the Cheorwon, Korea (철원지역에서 월동하는 두루미와 재두루미의 인위적 요인에 의한 분포양상)

  • Yoo, Seung-Hwa;Kim, Jin-Han;Lee, Ki-Sup
    • Korean Journal of Environment and Ecology
    • /
    • v.28 no.5
    • /
    • pp.516-522
    • /
    • 2014
  • This study was conducted to investigate the impact of the anthropogenic factors affecting distribution of the Red-crowned Crane and White-naped Crane wintering in Cheorwon, Korea. Especially, it was investigated that the impact power and its range of the anthropogenic effect to the feeding flock density in cranes due to the paved road, residential area, military facilities and greenhouse density. The Red-crowned Crane and the White-naped Crane showed the similar preference and sensitivity against anthropogenic factors, because correlation of feeding flock density of the Red-crowned Crane and White-naped Crane was similar in the same site. The feeding flock density of the cranes near the residential area was lower than that of area far from the area, and tended to increase within 2.5 km distance. The increasing tendencies of feeding flock density from military facilities and high traffic volume road were similar, but the density in military facilities increased within 0.8 km, and the density from high traffic volume road increased within 2 km. This results suggested that military facilities and the road with high traffic volume made significant influence on foraging densities to the certain range. As the distance from the road with low traffic volume increased, feeding flock density tended to decrease. The area near the low traffic volume road had high feeding flock density because remaining rice grains were preserved by intermittent disturbances in that area. If the density of greenhouse is lower than $40/km^2$, feeding flock density in the low greenhouses density area was higher than high greenhouses density area. However, there was no difference in the feeding flock density if the density of the green houses is higher than $40/km^2$.