• Title/Summary/Keyword: high voltage generator

Search Result 573, Processing Time 0.162 seconds

A High Voltage Power Supply for X-Ray Tube Using High Frequency (고주파 인버터식 X-선관용 고전압 전원장치)

  • Kim, H.S.;Yoo, D.W.;Cho, J.G.;Back, J.W.;Rim, G.H.;Won, C.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2246-2248
    • /
    • 1997
  • This paper presents a high-frequency inverter type high-voltage power supply for X-ray equipments. The high-voltage generator consist of an inverter unit including the SR(Series Resonance) type PSC(Phase-Shifted Control) PWM circuit adopting IGBT as the switching power device and high-voltage unit including the CW(Cockcroft Walton) circuit. When the X-ray equipment is radiographing at large power for a short time, this generator operates through feedback voltage mode control to obtain a high speed leading edge and low ripple. The operating modes and design consideration of the proposed power supply are given. Issues in the design of high-voltage divider for high voltage measuring. Experimental results are presented to verify the performance of the designed power supply for varying load conditions. The proposed apparatus has several advantages, e.g., the fast rising time of tube voltage, accuracy and reduced component size etc.

  • PDF

A Study On Hardware Design for High Speed High Precision Neutron Measurement (고속 고정밀 중성자 측정을 위한 하드웨어 설계에 관한 연구)

  • Jang, Kyeong-Uk;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.20 no.1
    • /
    • pp.61-67
    • /
    • 2016
  • In this paper, a hardware design method is proposed for high speed high precision neutron radiation measurements. Our system is fabricated to use a high performance A/D Converter for digital data conversion of high precision and high speed analog signals. Using a neutron sensor, incident neutron radiation particles are detected; a precision microcurrent measurement module is also included: this module allows for more precise and rapid neutron radiation measurement design. The high speed high precision neutron measurement hardware system is composed of the neutron sensor, variable high voltage generator, microcurrent precision measurement component, embedded system, and display screen. The neutron sensor detects neutron radiation using high density polyethylene. The variable high voltage generator functions as a 0 ~ 2KV variable high voltage generator that is robust against heat and noise; this generator allows the neutron sensor to perform normally. The microcurrent precision measurement component employs a high performance A/D Converter to precisely and swiftly measure the high precision high speed microcurrent signal from the neutron sensor and to convert this analog signal into a digital one. The embedded system component performs multiple functions including neutron radiation measurement for high speed high precision neutron measurements, variable high voltage generator control, wired and wireless communications control, and data recording. Experiments using the proposed high speed high precision neutron measurement hardware shows that the hardware exhibits superior performance compared to that of conventional equipment with regard to measurement uncertainty, neutron measurement rate, accuracy, and neutron measurement range.

X-선 발생장치 정류방식에 따른 출력특성에 관한 연구

  • Na, Gil-Ju;Baek, Su-Ung;Yang, Hyeon-Hun;Park, Gye-Chun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.126-126
    • /
    • 2009
  • X-ray high-voltage generator is the most important part that can decide the radiation exposure dose affecting a patient or operator according to the characteristic. If decrease of X-ray radiation exposure dose and output characteristic of high-voltage generator is unstable, a patient or operator must be exposed to more radiation. This study measures and analyzes the exposure dose reproducibility and output characteristic according to a change of tube current on the various rectification methods of diagnostic X-ray equipment. It can find that quality bastardize and output is increased if voltage of X-ray tube is increased. Exposure dose reproducibility according to output of X-ray equipment is extremely excellent in inverter type, and is stable in order of following three-phase, a single-phase and condenser method. This study can find that the reply incidence of high-voltage generator is generated due to difference in rectification method, noise occurs in X-ray due to that, quality of an image is decreased due to that, and medical diagnosis can be failed due to that.

  • PDF

Generation of a High Voltage Pulse of 50 ns Pulse Duration using a Helical Blumlein Pulse Forming Line (나선형 블룸라인 PFL을 이용한 50 ns 펄스폭의 고전압 펄스 발생)

  • Roh, Youngsu;Jin, Yun-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.786-791
    • /
    • 2013
  • A high voltage pulse generator based on the Blumlein pulse forming line (PFL) was fabricated to produce a voltage pulse whose peak value is ~300 kV and pulse duration is ~50 ns. Three cylindrical electrodes, such as inner, middle, and outer electrodes, are concentrically placed to make a compact PFL. To increase the pulse duration of the output pulse without any change of the size of the generator, the middle electrode is replaced by a helical strip electrode. To determine the radius of the helical electrode, the impedance of the helical Blumlein PFL is calculated using an approximate formula where the dispersive property of the helical Blumlein PFL is not considered. The dependence of the impedance on the frequency is computed by a commercial program. The number of turns in the helical electrode is decided to provide a demanded pulse duration. The experimental result shows that the helical Blumlein PFL is capable of making a high voltage pulse of ~50 ns pulse duration.

A EMTP Simulation of High-Voltage Pulse Transformer for Pulsed Power System (펄스파워 시스템용 고전압 펄스변압기의 EMTP 시뮬레이션)

  • Kim, Min-Soo;Lee, Hyong-Gu;Ju, Heung-Jin;Ko, Kwang-Cheol;Kan, Hyong-Bu
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1984-1986
    • /
    • 2000
  • In pulsed-power techniques. Marx generator is generally used for the high-power device. but this generator has insulation and spatial problems. So we will suggest a pulse transformer that has a small size to generate the high voltage pulse instead of Marx generator. In this paper, Pulse duration is 4 [${\mu}s$] and the ratio of input and output voltage is 40[kV]/200[kV](step-up ratio=5). The output voltage and the process of pulse compression for pulse circuit are simulated by EMTP (Electro-Magnetic Transient Program). The secondary voltage of pulse transformer is about 200[kV] and pulse width is 4[t/s]. When the secondary winding of the pulse transformer is saturated. the pulse width is 1.25[${\mu}s$]. We selected dummy load 50[$\Omega$] for impedance matching. The pulse voltage of dummy load is 100[kV] and pulse width is 500[ns].

  • PDF

Cost Effective Design of High Voltage Impulse Generator and Modeling in Matlab

  • Javid, Zahid;Li, Ke-Jun;Sun, Kaiqi;Unbreen, Arooj
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1346-1354
    • /
    • 2018
  • Quality of the power system depends upon the reliability of its components such as transformer, transmission lines, insulators, circuit breakers and isolators. The transient voltage due to internal or external reasons may affect the insulation level of the components. The insulation level of these components must be tested against these conditions. Different studies, testing of different electrical components against high voltage impulses and different industrial applications rely on the international manufactures for pulsed power generation and testing, that is quite expensive and large in size. In this paper a model of impulse voltage generator with capacitive load of pin type insulator is studied by simulation method and by an experimental setup. A ten stage high voltage impulse generator (HVIG) is designed and implemented for different applications. In this proposed model, the cost has been reduced by using small and cheap capacitors as an alternative for large and expensive ones while achieving the same effectiveness. Effect of the distributed capacitance in each stage is analyzed to prove the effectiveness of the model. Different values of front and tail resistances have been used to get IEC standard waveforms. Results reveal the effectiveness at reduced cost of the proposed model.

200 kV 50 ns Coaxial Type Mini Marx Generator (200 kV, 50 ns급 동축형 Mini Marx 펄스발생장치)

  • Lee, Sang-Woog;Lee, Chae-Min;Chang, Yong-Moo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.481-482
    • /
    • 2008
  • We have designed a Marx Generator, named EMD Pulse Generator(EPG), which makes steep front high voltage, 50ns rise time and 200kV high. It was designed as coaxial type and in small size, 70cm high and 20cm in diameter. The firing system is trigatron type and the spark gap switches in each stage are coaxial with the axis of the system. In this paper we mention about the characteristics of EPG and several experimental data.

  • PDF

A study on the design of triggering pulse generator for the triggered vacuum switch (진공스위치 트리거 발생기 설계에 관한연구)

  • Kim, Mu-Sang;Son, Yun-Gyu;Park, Ung-Hwa;Lee, Byeong-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.201.2-201.2
    • /
    • 2016
  • The triggered vacuum switch (TVS) is widely used as a high power switch in the field of pulsed power application. TVS can produce current of higher than 100 kA within a microsecond after being triggered. A triggering high voltage pulse generator supplies a high voltage signal to the trigger system to initiate the discharge between a trigger pin and one of main electrode. The trigger system, which consists of a tungsten trigger electrode and cylindrical ceramic insulator around it, is normally installed at the center of main cathode electrode. The discharging characteristics of the trigger system strongly depend on the geometry, electrode material, vacuum pressure and so on. In addition, we especially will focus on the developing a triggering pulse generator, which can vary not only value of voltage but also pulse duration, because its properties gives pivot influences on the TVS discharge. To verify such effects, we made a 3.3 kJ TVS set-up initially. Thus we will discuss some of prominent results from 3.3 kJ TVS system. In parallel we will show on the design of 300 kJ TVS system for the high current in the future.

  • PDF

Controlling Zero Sequence Component in DVR for Compensating Unbalanced Voltage Dip of a DFIG

  • Ko, JiHan;Thinh, Quach Ngoc;Kim, SeongHuyn;Kim, Eel-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.154-155
    • /
    • 2012
  • The dynamic voltage restorer (DVR) is an effective protection device for wind turbine generator based on doubly-fed induction generator (DFIG) operated under the unbalanced voltage dip conditions. The compensating voltages of DVR depend on the voltage dips and on the influence of the zero sequence components. If the $Y_0/{\Delta}$ step-up transformers are used, there are no zero sequence components on the DFIG side. However, if the $Y_0/Y_0$ step-up transformers are used, the zero sequence components will appear during faults. The zero sequence components result in the high insulation costs and the asymmetric of the terminal voltages. This paper proposes a method for controlling zero sequence components in DVR to protect DFIG under unbalanced voltage dips. Simulation results are presented to verify the effectiveness of the proposed control method.

  • PDF

Comparison of Ripple of High Voltage X-ray Generator by Rectification type (X선 고전압 장치의 정류형태에 따른 리플 비교)

  • Kim, Young-Pyo;Kim, Tae-Gon;Cheon, Min-Woo;Lee, Ho-Shik;Park, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.128-128
    • /
    • 2010
  • The high-voltage X-ray generator recently used is very popular, because that can be miniaturized, increased in generating efficiency, elaborated in output control. All these features are available with high-frequency made by using an inverter, the fast switching semiconductor device. In this paper to identify the differences among types of rectification, we compared output ripple with full-wave rectification and dual-voltage rectification methods.

  • PDF