• 제목/요약/키워드: high voltage

검색결과 10,497건 처리시간 0.036초

고전압 Non Punch Through IGBT 및 Field Stop IGBT 최적화 설계에 관한 연구 (The Optimal Design of High Voltage Non Punch Through IGBT and Field Stop IGBT)

  • 강이구
    • 한국전기전자재료학회논문지
    • /
    • 제30권4호
    • /
    • pp.214-217
    • /
    • 2017
  • An IGBT (insulated gate bipolar transistor) device has an excellent current-conducting capability. It has been widely employed as a switching device to use in power supplies, converters, solar inverters, and household appliances or the like, designed to handle high power. The aim with IGBT is to meet the requirements for use in ideal power semiconductor devices with a high breakdown voltage, an on-state voltage drop, a high switching speed, and high reliability for power-device applications. In general, the concentration of the drift region decreases when the breakdown voltage increases, but the on-resistance and other characteristics should be reduced to improve the breakdown voltage and on-state voltage drop characteristics by optimizing the design and structure changes. In this paper, using the T-CAD, we designed the NPT-IGBT (non punch-through IGBT) and FS-IGBT (field stop IGBT) and analyzed the electrical characteristics of those devices. Our analysis of the electrical characteristics showed that the FS-IGBT was superior to the NPT-IGBT in terms of the on-state voltage drop.

6배압 정류기를 이용한 고전압 전원장치에 관한 연구 (A Study of the High Voltage Power Supply using a Sixfold Voltage-Multiplying Rectifier)

  • 안태영;길용만
    • 조명전기설비학회논문지
    • /
    • 제29권2호
    • /
    • pp.19-26
    • /
    • 2015
  • This paper presents design, fabrication, and performance evaluation of a high voltage power supply for Carbon Nano Tube-based planar light sources. The proposed power supply employs an LLC resonant half-bridge converter and a sixfold voltage-multiplying rectifier. Steady-state characteristics of the voltage-multiplying rectifier are analyzed and used to derive the input-to-output voltage conversion ratio of the power supply. The input-to-output frequency response characteristics of the LLC tank circuit are analyzed and utilized in designing a proto-type power supply which produces a 15 KV output using a 400 V input source. The high-voltage transformer is fabricated using a sectional bobbin structure with an epoxy impregnation, in order to provide sufficient insulation for high voltage operations. The performance of the proposed power supply is confirmed with stable and reliable operations at the 15 KV output from no load to nominal load conditions. The proposed power supply is well suited as an electric ballast required stable operations of Carbon Nano Tube-based planar light sources.

Development of the High Input Voltage Self-Power for LVDC

  • Kim, Kuk-Hyeon;Kim, Soo-Yeon;Choi, Eun-Kyung;HwangBo, Chan;Park, Seong-Mi;Park, Sung-Jun
    • 한국산업융합학회 논문집
    • /
    • 제24권4_1호
    • /
    • pp.387-395
    • /
    • 2021
  • Distributed resources such as renewable energy sources and ESS are connected to the low voltage direct current(LVDC) distribution network through the power conversion system(PCS). Control power is required for the operation of the PCS. In general, controller power is supplied from AC power or DC power through switch mode power supply(SMPS). However, the conventional SMPS has a low input voltage, so development and research on high input voltage self-power suitable for LVDC is insufficient. In this paper, to develop Self-Power that can be used for LVDC, the characteristics of the conventional topology are analyzed, and a series-input single-output flyback converter using a flux-sharing transformer for high voltage is designed. The high input voltage Self-Power was designed in the DCM(discontinuous current mode) to reduce the switching loss and solve the problem of current dissipation. In addition, since it operates even at low input voltage, it can be applied to many applications as well as LVDC. The validity of the proposed high input voltage self-power is verified through experiments.

고전압.대전류 pulsed power의 이용기술 (Application Technologies of Pulsed Power with the High Voltage and Current)

  • 이형호;김영배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1678-1680
    • /
    • 1997
  • The pulsed power with the high voltage and current can be used to the fields of high speed pulses of energy in different forms such as electric current and voltage, electron beam, ion beam, x-rays, gamma rays, heat, magnetics fields, sound and shock waves. This paper is directed mainly at electrical engineers working on production and practical application of high speed pulsed power with high voltage and current.

  • PDF

광복합 고압지중전력케이블의 개발에 관한 연구 (A Study on the development of optical fiber incorporated high-voltage underground power cable)

  • 류재규;유성종;전승익;최봉남;이영익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1828-1830
    • /
    • 1996
  • In this study, We developed the optical fiber incorporated high-voltage underground power cable which is combined optical fibers with conventional high-voltage underground power cable. Optical-Unit that optical fiber is inserted in stainless tube is tested, and we got good results enough to safe optical fibers. Also we put the optical fiber incorporated high-voltage underground power cable to the test of electrical characteristics and optical characteristics, we knew that the electrical characteristics were the same characteristics as conventional high-voltage underground power cable and the transmission loss change was almost zero.

  • PDF

전력계통의 고임피던스 고장 검출 기법에 관한 연구 (A Study on High Fault Detection In Power System)

  • 임화영;유창완;고재호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권1호
    • /
    • pp.16-21
    • /
    • 1999
  • The analysis of distribution line faults is essential to the proper protections of the power system. A high impedance fault test, which was carried in Korean electric power systems, it was found that a arcing phenomenon occurred during the high level portion of conductor voltage in each cycle. In this paper, we propose a new method for detection of high impedance faults, which uses the arcing fault current difference during high voltage and low voltage portion of conductor voltage waveform. To extract this difference, we diveded one cycle fault current into equal spanned four data windows according to the magnitude of voltage waveform and applied fast fourier transform(FFT) to each data window. The frequency spectrum of current wavefrom in each portion are used as the inputs of neural network and is trained to detect high impedance faults. The proposed method shows improved accuracy when applied to staged fault data and fault-like load.

  • PDF

진단용 X선 기기의 고전압 발생장치 개발 (Development of High Voltage Generator for Diagnostic X-ray Equipment)

  • 김영표;김태곤;천민우;박용필
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 추계학술대회
    • /
    • pp.764-765
    • /
    • 2010
  • 인체의 진단에 사용되는 의료용 X선 기기는 비 침습적인 방법으로 인체 내부의 진단이 가능하여 의료기관에서 진단에 매우 큰 비중을 차지하고 있다. X선의 발생에 가장 중요한 고전압 발생장치는 기존 변압기 식이 주로 사용되었으나 크고 무거우며 직류 고전압의 리플이 커서 발생효율이 낮다. 이러한 단점을 보완하기 위해 인버터를 사용하여 입력전원의 주파수를 고주파하는 인버터 방식의 고전압 발생장치가 주로 사용되고 있다. 본 연구에서는 펄스폭 변조 방식을 적용하여 관전압과 관전류의 동작을 제어 하였으며, 오실로 스코프를 이용하여 동작 결과를 확인하였다.

  • PDF

고전압맥동전류에 의한 일차 및 이차통각과민대의 RIII 반사의 변화 (Change of RIII Reflex of Primary and Secondary Hyperalgesia Site by High Voltage Pulsed Current)

  • 김수현;최석주;이정우;정진규;김태열;김계엽
    • 대한임상전기생리학회지
    • /
    • 제4권1호
    • /
    • pp.1-12
    • /
    • 2006
  • This study conducted RIII reflex measurement to examine degree of pain depending on polarity of high voltage pulsed current of primary and secondary hyperalgesia site in hyperalgesia rat by local thermal injury. Hind paw which was injury site was taken as primary hyperalgeisa site, sole which was injury adjacent site was taken as secondary hyperalgesia site, and mechanical pain threshold, thermal pain threshold and root mean square of RIII reflex were measured. This study was conducted with control group I of hyperalgesia rat at hind paw by thermal injury and experimental groups divided into cathodal high voltage treatment group II, anodal high voltage treatment group III and alternate high voltage treatment group IV, applied active electrode of high voltage pulsed current to hind paw directly, placed reference electrode on the sole of injury adjacent site and applied pulse frequency. It measured RIII reflex and obtained the following results: Root mean square of RIII reflex at primary hyperalgeisa site was significantly reduced in group II after 2 days of hyperalgesia. Group II showed significant decrease after 5 and 6 days of hyperalgesia. Root mean square of RIII reflex at secondary hyperalgesia site showed significant reduction in group II after 6 days of hyperalgesia. Consequently it was found that application of high voltage pulsed current of hyperalgesia site reduced RIII reflex at primary hyperalgeisa site and secondary hyperalgesia site by electrical stimuli. Effects by polarity of high voltage pulsed current showed the greatest reduction of pain threshold when cathodal active electrode was used.

  • PDF

High Efficiency Design Procedure of a Second Stage Phase Shifted Full Bridge Converter for Battery Charge Applications Based on Wide Output Voltage and Load Ranges

  • Cetin, Sevilay
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.975-984
    • /
    • 2018
  • This work presents a high efficiency phase shifted full bridge (PSFB) DC-DC converter for use in the second stage of a battery charger for neighborhood electrical vehicle (EV) applications. In the design of the converter, Lithium-ion battery cells are preferred due to their high voltage and current rates, which provide a high power density. This requires wide range output voltage regulation for PSFB converter operation. In addition, the battery charger works with a light load when the battery charge voltage reaches its maximum value. The soft switching of the PSFB converter depends on the dead time optimization and load condition. As a result, the converter has to work with soft switching at a wide range output voltage and under light conditions to reach high efficiency. The operation principles of the PSFB converter for the continuous current mode (CCM) and the discontinuous current mode (DCM) are defined. The performance of the PSFB converter is analyzed in detail based on wide range output voltage and load conditions in terms of high efficiency. In order to validate performance analysis, a prototype is built with 42-54 V / 15 A output values at a 200 kHz switching frequency. The measured maximum efficiency values are obtained as 94.4% and 76.6% at full and at 2% load conditions, respectively.

Reduced Swing 방식과 Low-Vt 고전압 소자를 이용한 고속 레벨시프터 설계 (A Design of High-Speed Level-Shifter using Reduced Swing and Low-Vt High-Voltage Devices)

  • 서해준;김영운;류기주;안종복;조태원
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.525-526
    • /
    • 2008
  • This paper proposes a new high-speed level shifter using a special high voltage device with low threshold voltage. Also, novel low voltage swing method is proposed. The high voltage device is a standard LDMOS(Laterally Diffused MOS) device in a $0.18{\mu}m$ CMOS process without adding extra mask or process step to realize it. A level shifter uses 5V LDMOSs as voltage clamps to protect 1.8V NMOS switches from high voltage stress the gate oxide. Also, level-up transition from 1.8V to 5V takes only 1.5ns in time. These circuits do not consume static DC power, therefore they are very suitable for low-power and high-speed interfaces in the deep sub-quarter-micron CMOS technologies.

  • PDF