• Title/Summary/Keyword: high tension strength concrete

검색결과 180건 처리시간 0.028초

Improved prestressed concrete girder with hybrid segments system

  • Yim, Hong Jae;Yang, Jun Mo;Kim, Jin Kook
    • Structural Engineering and Mechanics
    • /
    • 제65권2호
    • /
    • pp.183-190
    • /
    • 2018
  • The prestressed concrete (PSC) technology that was first developed by Freyssinet has significantly improved over the past century in terms of materials and structural design in order to build longer, slender, and more economic structures. The application of prestressing method in structures, which is determined by the pre-tension or post-tension processes, is also affected by the surrounding conditions such as the construction site, workforce skills, and local transportation regulations. This study proposes a prestressed concrete girder design based on a hybrid segment concept. The adopted approach combines both pre-tension and post-tension methods along a simple span bridge girder. The girder was designed using newly developed 2400 MPa PS strands and 60 MPa high-strength concrete. The new concept and high strength materials allowed longer span, lower girder depth, less materials, and slender design without affecting the lateral stability of the girder. In order to validate the applicability of the proposed hybrid prestressed segments girder, a full-scale 35 m girder was fabricated, and experimental tests were performed under various fatigue and static loading conditions. The experimental results confirmed the feasibility of the proposed long-span girder as its performance meets the railway girder standards. In addition, the comparison between the measured load-displacement curve and the simulation results indicate that simulation analysis can predict the behavior of hybrid segments girders.

Concrete Stress Block Parameters for High-Strength Concrete : Recent Developments and Their Impact

  • Bae, Sun-Gjin
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권1E호
    • /
    • pp.11-16
    • /
    • 2006
  • The use of the current ACI 318 stress block parameters has been reported to provide unconservative estimations of the moment capacities for high-strength concrete columns. Accordingly, several concrete stress block parameters have been recently proposed. This paper discusses various concrete stress block parameters for high-strength concrete and their influences on the code provisions. In order to adopt the proposed stress block parameters to the design code, it is necessary to understand the impact of the change of the stress block parameters on various aspects of the code provisions. For this purpose, the influence of using of different stress block parameters on the location of the neutral axis and the tensile strain in extreme tension steel as well as the axial and moment capacities are investigated. In addition, the influence on the prestressed concrete members is also elucididated.

PT공법을 적용한 80MPa급 콘크리트 아웃리거부재의 실험적 연구 (Experimental study of structural behavior of 80MPa concrete outrigger member using post tension method)

  • 최종문;김우재
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.31-34
    • /
    • 2009
  • Large outrigger elements tie the concrete core to perimeter columns, significantly increasing the building's lateral stiffness as well as its resistance to overturning due to wind. The outriggers are deep elements, and large tie forces are resisted by top and bottom heavy longitudinal reinforcing and vertical ties. To reduce construction costs, all primary reinforcing bars in outrigger levels are SD500. Further, concrete strengths of 80MPa have been specified for outrigger elements. However, the reductions in the amount of concrete and reinforcement steel are more increased in tall building. With these backgrounds, 80MPa high strength concrete outrigger system using post tension method is developed. Significant economic savings can be made by reducing the element sizes and material content. The developed outrigger system is designed using strut-and-tie models. In addition, four 1/4-scale test specimens were selected from the same prototype structure. The results from the tests are confirmed that the structural behaviors of the developed outrigger member have better capacities than those of a conventional method.

  • PDF

누적손상을 고려한 강섬유보강 콘크리트의 피로파괴 특성 (Fatigue Failure Characteristics of Steel Fiber Reinforced Concrete Considering Cumulative Damage)

  • 김동호;홍창우;이주형;이봉학
    • 한국농공학회지
    • /
    • 제44권2호
    • /
    • pp.117-126
    • /
    • 2002
  • Concrete containing discontinuous discrete steel fiber in a normal concrete is called steel fiber reinforced concrete(SFRC). Tensile as well as flexural strengths of concrete could be substantially increased by introducing closely spaced fibers which delay the onset of tension cracks and increase the tension strength of cracks. However, many properties of SFRC have not been investigated, especially properties on repeated loadings. Thus, the purposes of this dissertation is to study the flexural fatigue characteristics of SFRC considering cumulative damage. A series of experimental tests such as compressive strength, splitting tensile strength, flexural strength, flexural fatigue, and two steps stress level fatigue were conducted to clarify the basic properties and fatigue-related properties of SFRC. The main experimental variables were steel fiber fraction (0, 0.4, 0.7, 1, 1.5%), aspect ratio (60, 83). The principal results obtained through this study are as follows: The results of flexural fatigue tests showed that the flexural fatigue life of SFRC is approxmately 65% of ultimate strength, while that of plain is less than 58%. Especially, the behavior of flexural fatigue life shows excellent performance at 1.0% of steel-fiber volume fraction. The cumulative damage test of high-low two stress levels is within the value of 0.6 ∼ 1.1, while that of low-high stress steps is within the value of 2.4 ∼ 4.0.

고속비상체 충돌에 대한 섬유보강 콘크리트의 국부파괴 매커니즘 분석 (Analysis of Local Failure Machanism of Fiber Reinforced Concrete by Impact of High-Velocity Projectile)

  • 한상휴;김규용;김홍섭;이보경;김정현;김래환
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.28-29
    • /
    • 2014
  • In this study, flexural strength by fiber reinforced for steel fiber and reinforced polyamide fiber concrete, and concrete fracture properties by improvement of flexural toughness and high-velocity projectile impact were evaluated. As a result, it was confirmed that flexural strength are improved by distribution of stress and suppress of cracks, and the back desquamation of concrete by high-velocity projectile impact is suppressed. In addition, It was observed that the spalling of rear is caused when tension stress is caused as shock wave by high-velocity projectile impact was transferred to the rear and tension stress is suppressed by fiber reinforcement.

  • PDF

전단보강이 있는 강섬유 보강 고강도 철근콘크리트 보의 전단 및 연상에 관한 연구 (Shear Strenhth and Ductility of Steel-Fiber Reinforced High Strength Concrete Beams with Shear Confinement)

  • 오정근;이광수;권영호;신성우
    • 콘크리트학회지
    • /
    • 제2권4호
    • /
    • pp.53-60
    • /
    • 1990
  • 전단보강된 고강도콘크리트 보의 역학적 거동을 알아보기 위하여 총9개의 시험체가 제작되었다. 콘크리트 압축강도가 800kg/$\textrm{cm}^2$ 전단스팬비가 3 그리고 주근비가 0.5Pb로 일정할 때 주요변수로서 전단보강비(Vs=0,25,50%)와 섬유첨가율(Vf=0,0.5,1%)로 두었다. 시험결과로 섬유첨가율의 증가에도 극한강도의 변화는 별반 없었으나 연성 능력을 향상시켰으며, 전단보강철근으로의 대체성을 보여주었다.

횡보강근이 없는 100 MPa 이하 콘크리트의 철근 압축이음 강도와 이음길이 (Capacity and Length of Compression Lap Splice in Unconfined Concrete of 100MPa and Less Compressive Strength)

  • 천성철;이성호;오보환
    • 콘크리트학회논문집
    • /
    • 제22권5호
    • /
    • pp.659-666
    • /
    • 2010
  • 현행 설계기준식에 따르면 초고강도 콘크리트에서는 철근 인장이음길이보다 압축이음길이가 더 길어지는 현상이 발생된다. 압축이음은 단부 지압이 존재하므로, 인장이음보다 길 필요는 없다. 초고강도 콘크리트의 경제적 실용화를 위해 합리적인 압축이음강도의 평가가 필요하다. 이를 위해 설계강도 80, 100 MPa 콘크리트를 이용하여 횡보강근이 없는 압축이음 실험을 수행하였다. 실험 결과 압축이음강도는 콘크리트 강도의 제곱근에 비례하는 것으로 평가되었다. 지압에 의해 발현되는 이음강도는 이음길이와 무관하며 콘크리트 강도의 제곱근에 비례하는 것으로 평가되었다. 58개 실험체의 평균은 $16.5\;\sqrt{f_{ck}}$이다. 부착에 의해 발현되는 강도를 ACI 408식으로 평가한 결과 [실험값]/[이론값]의 비는 평균 0.94로, 인장이음의 부착강도와 거의 유사하였다. 따라서 인장이음강도에 대비한 압축이음강도의 향상은 단부 지압효과로 설명될 수 있다. 실험결과에서 분석된 이음길이와 콘크리트 강도의 영향 특성을 고려하여 압축이음강도 평가식과 압축이음길이 설계식을 제안하였다. 제안된 설계식은 통계적 기법에 기반을 두어, 이음부가 철근 재료강도와 동일한 수준의 신뢰성을 확보할 수 있다.

인발법을 포함한 비파괴시험법에 대한 특성 비교 (A Study on the Characteristics of Nondestuctive Tests Including Pullout Test)

  • 고훈범;정성원;음성우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 봄 학술발표회 논문집
    • /
    • pp.211-215
    • /
    • 1996
  • This paper presents comparisons of pullout load of concrete with compressive strength of cylinders and cores, pulse velocity, and rebound number. A pullout test, which is a relatively new nondestructive technique, measures with a special tension ram the force required to pullout a specially shaped steel rod whose enlarged end has been cast into a concrete block. In this study 3 concrete mixes(normal strength, high-strength & super-high-strength) were made. From each mix, one 100$\times$70$\times$20 concrete block, 24 cylinders$(\phi10mm)$were casted. Each tests were performed on the concrete blocks at 3, 7, 28, and 91days. The test data shows that the pullout test is superior to the rebond hammer and the pulse velocity measurements on the evaluation of concrete strength. The pullout test is satisfactory for estimating the strength of in situ concrete at both early and late age, and its results can be reproduced with an acceptable degree of accuracy.

  • PDF

Post-cracking behavior of UHPC on the concrete members reinforced by steel rebar

  • Rahdar, H.A.;Ghalehnovi, M.
    • Computers and Concrete
    • /
    • 제18권1호
    • /
    • pp.139-154
    • /
    • 2016
  • Since the concrete strength around the reinforcement rebar affects the tension stiffening, the tension stiffening effect of ultra high performance concrete on the concrete members reinforced by steel rebar is examined by testing the specimens with circular cross section with the length 850 mm reinforced by a steel rebar at the center of a specimen's cross section in this research. Conducting a tensile test on the specimens, the cracking behavior is evaluated and a curve with an exponential descending branch is obtained to explain the post-cracking zone. In addition, this paper proposes an equation for this branch and parameters of equation is obtained based on the ratio of cover thickness to rebar diameter (c/d) and reinforcement percentage (${\rho}$).

New constitutive models for non linear analysis of high strength fibrous reinforced concrete slabs

  • Yaseen, Ahmed Asaad;Abdul-Razzak, Ayad A.
    • Structural Engineering and Mechanics
    • /
    • 제82권1호
    • /
    • pp.121-131
    • /
    • 2022
  • The main goal of this study is to prepare a program for analyzing High Strength Steel Fibrous Reinforced Concrete (HSSFRC) slabs and predict the response and strength of the slab instead of preparing a prototype and testing it in the laboratory. For this purpose, new equations are proposed to represent the material properties of High Strength Steel Fibrous Reinforced Concrete. The proposed equations obtained from performing regression analysis on many experimental results using statistical programs. The finite element method is adopted for non-linear analysis of the slabs. The eight-node "Serendipity element" (3 DoF) is chosen to represent the concrete. The layered approach is adopted for concrete elements and the steel reinforcement is represented by a smeared layer. The compression properties of the concrete are modeled by a work hardening plasticity approach and the yield condition is determined depending on the first two stress invariants. A tensile strength criterion is adopted in order to estimate the cracks propagation. many experimental results for testing slabs are compared with the numerical results of the present study and a good agreement is achieved regarding load-deflection curves and crack pattern. The response of the load deflection curve is slightly stiff at the beginning because the creep effect is not considered in this study and for assuming perfect bond between the steel reinforcement and the concrete, however, a great agreement is achieved between the ultimate load from the present study and experimental results. For the models of the tension stiffening and cracked shear modulus, the value of Bg and Bt (Where Bg and Bt are the curvature factor for the cracked shear modulus and tension stiffening models respectively) equal to 0.005 give good results compared with experimental result.