• Title/Summary/Keyword: high temperature retention time

Search Result 100, Processing Time 0.029 seconds

Applied-mineralogical Characterization for the Quick-lime Manufactured from Fine-grained Domestic Limestones (국내산 세립질 석회석으로부터 제조된 생석회에 대한 응용광물학적 특성 평가)

  • Noh, Jin-Hwan;Lee, Hyun-Chul
    • Journal of the Mineralogical Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.261-277
    • /
    • 2009
  • This study is aimed to emphasize the significance of ore selection in lime manufacturing through the evaluation of applied-mineralogical impact factors of crude ores controlling calcination characteristics for some domestic limestones used currently for lime manufacturing. To do this work, systematic characterization and determination were carried out for the limestone ores and their calcination products in a fixed calcining condition (target temperature: $1000^{\circ}C$, retention time: 30 minutes, 2, 4, 10, 16 hours), and the results were correlated and discussed. Selected high-Ca limestones in this study are as much as > 98 wt%, but they are somewhat diverse in crystallinity, texture, and impurity composition. Synthesized quicklimes are varied depending on such a difference in ore characters. The Pungchon limestone has relatively very low calcination rate, and the limestones from the Gabsan formation and the Jeongseon formation exhibit good quality in calcination rate and decrepitation. Among these samples, the limestone ore from the Jeongseon formation is evaluated to be the best for crude ore in manufacturing of highly-reactive quicklime. In addition, it is characteristic that the Gabsan limestone comparative rich in Fe-bearing mineral such as pyrite and goethite is more conspicuous in sintering effect.

Determination of Phorate (0,0-diethyl S-ethylthiomethyl phosphorithioate) and its Metabolites in Soil and Vegetables by GLC (토양(土壤)과 채소중(菜蔬中) Phorate(0,0-diethyl S-ethylthiomethyl phosphorithioate)와 그 대사산물(代謝産物)들의 GLC분석(分析))

  • Hong, Jong-Uck;Lee, Hae-Keun
    • Applied Biological Chemistry
    • /
    • v.26 no.2
    • /
    • pp.104-109
    • /
    • 1983
  • Gas chromatographic method for the analysis of phorate(0,0-diethyl S-ethyl-thiomethyl phosphorithioate) and its metabolites in soil and vegetables was studied by using a mixed phase column(10% DC-200+8% Reoplex-400+2% QF-1 on Gas Chrom Q, $1.8{\times}2mm$ i.d, borosilicate glass column). This column can separate completely phorate and its four metabolites except phoratoxon sulfoxide. Retention time of standard mixture ranged 1.8 to 16.1 minutes at column temperature programming from 130 to $200^{\circ}C$ at $5^{\circ}C/min$ and detector sensitivity was also very high(0.05 to 1.05ng). Recoveries from soil and vegetables untreated but fortified with phorate and its three major metabolites at 0.05 and 0.5ppm levels were above 90% for phorate, phorate sulfoxide and phorate sulfone while recovery of phoratoxon metabolite was about 84%.

  • PDF

Evaluation of Decomposition Characteristics of Organochlorine Pesticides Using Thermal Method (열적방법을 활용한 유기염소계 폐농약의 분해 특성 평가)

  • Kwon, Eun-Hye;Yoon, Young-Sam;Bea, Ji-Su;Jeon, Tae-Wan;Lee, Young-Ki
    • Journal of Korea Society of Waste Management
    • /
    • v.35 no.8
    • /
    • pp.744-753
    • /
    • 2018
  • The Stockholm Convention, which was adopted in Sweden in 2001 to protect human health and the environment, includes regulations for Persistent Organic Pollutant Rotors such as toxic and bioaccumulatives. Currently, there are 28 types of materials. This prohibits and limits the production, use, and manufacture of products. Korea is a member of the Convention, and it is necessary to prepare management and treatment plans to address the POP trends. Thus, we experimentally investigate whether the environmentally stable incineration is achieved when the sample is thermally treated using the Lab-scale (1 kg/hr). The target samples is pesticides in liquid phase and solid phase. In this study, organic chlorinated pesticides and their thermal characteristics were analyzed. We calculated the theoretical air volume based on the element analysis results. Because the interior of the reactor is small, more than 10 times of the air ratio was injected. The retention time was set to at least 4 seconds using a margin. The incineration temperature was $850^{\circ}C$ and $1100^{\circ}C$. Thus, we experimentally investigated whether the environmentally stable incineration was achieved when the sample was thermally treated using the Lab-scale (1 kg/hr). We analyzed five types of exhaust gas; the 02 concentration was high, but the CO amount decreased. Complete combustion is difficult because of the small size of the furnace due to the nature of Lab-scale. The organic chlorine-containing pesticide had an average decomposition rate of 99.9935%. Considering the decomposition rates of organic chlorine-containing pesticide in this study, the incineration treatment at over 2 ton/hour, which is typical for a conventional incinerator, is possible. Considering the occurrence of dioxins and unintentional persistent organic pollutants, it can operate at more than $1,100^{\circ}C$.

Optimizing analytical method in Health Functional Food code with adjustable chromatographic parameters: A case study of vitamin C (건강기능식품공전 시험법의 크로마토그래프법 조건의 조정 및 비타민C에 대한 적용성 평가 연구)

  • Junghoon Shin;Yooseong Jeong;Yong Seok Choi;Sang Beom Han;Dong-Kyu Lee
    • Analytical Science and Technology
    • /
    • v.37 no.3
    • /
    • pp.143-154
    • /
    • 2024
  • In this study, we improved the vitamin C test method and reviewed data on the adjustable range of chromatography conditions for quantification. First, we adjusted the mobile phase conditions such as solvent composition, salt concentration, pH and column temperature and in particular, it was confirmed through an improved test method that the peak derived from the buffer solution could be clearly separated from the target component, vitamin C by adjusting the pH. The retention time of vitamin C was partially changed by adjusting the column diameter, length and particle size but the number of theoretical plates indicated similar values and did not affect the separation and quantitative analysis of the target component. The flow rate according to the column specifications was derived from the equation proposed by the U.S. FDA (Food and Drug administration) and the Korean MFDS (Ministry of Food and Drug Safety), and evaluation of the applicability to vitamin complexes showed high selectivity for vitamin C even with altered stationary phase conditions and flow rates. In conclusion, vitamin C can be optimally separated and detected by changing the chromatographic method conditions and it was confirmed that the mobile and stationary phase conditions of liquid chromatography can be slightly adjusted in case the assay method uses an isocratic elution.

Development of simultaneous analytical method for investigation of ketamine and dexmedetomidine in feed (사료 내 케타민과 덱스메데토미딘의 잔류조사를 위한 동시분석법 개발)

  • Chae, Hyun-young;Park, Hyejin;Seo, Hyung-Ju;Jang, Su-nyeong;Lee, Seung Hwa;Jeong, Min-Hee;Cho, Hyunjeong;Hong, Seong-Hee;Na, Tae Woong
    • Analytical Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.136-142
    • /
    • 2022
  • According to media reports, the carcasses of euthanized abandoned dogs were processed at high temperature and pressure to make powder, and then used as feed materials (meat and bone meal), raising the possibility of residuals in the feed of the anesthetic ketamine and dexmedetomidine used for euthanasia. Therefore, a simultaneous analysis method using QuEChERS combined with high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry was developed for rapid residue analysis. The method developed in this study exhibited linearity of 0.999 and higher. Selectivity was evaluated by analyzing blank and spiked samples at the limit of quantification. The MRM chromatograms of blank samples were compared with those of spiked samples with the analyte, and there were no interferences at the respective retention times of ketamine and dexmedetomidine. The detection and quantitation limits of the instrument were 0.6 ㎍/L and 2 ㎍/L, respectively. The limit of quantitation for the method was 10 ㎍/kg. The results of the recovery test on meat and bone meal, meat meal, and pet food showed ketamine in the range of 80.48-98.63 % with less than 5.00 % RSD, and dexmedetomidine in the range of 72.75-93.00 % with less than 4.83 % RSD. As a result of collecting and analyzing six feeds, such as meat and bone meal, prepared at the time the raw material was distributed, 10.8 ㎍/kg of ketamine was detected in one sample of meat and bone meal, while dexmedetomidine was found to have a concentration below the limit of quantitation. It was confirmed that the detected sample was distributed before the safety issue was known, and thereafter, all the meat and bone meal made with the carcasses of euthanized abandoned dogs was recalled and completely discarded. To ensure the safety of the meat and bone meal, 32 samples of the meat and bone meal as well as compound feed were collected, and additional residue investigations were conducted for ketamine and dexmedetomidine. As a result of the analysis, no component was detected. However, through this investigation, it was confirmed that some animal drugs, such as anesthetics, can remain without decomposition even at high temperature and pressure; therefore, there is a need for further investigation of other potentially hazardous substances not controlled in the feed.

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.

Effects of Dietary Beef Tallow, Soybean Oil and Squid Liver Oil on Growth and Body Composition of the Korean Rockfish Sebastes schlegeli, and Biochemical Changes with Starvation (사료 지질원으로 우지, 대두유 및 오징어 간유 첨가에 따른 조피볼락 Sebastes schlegeli의 성장 및 체성분 변화와 절식시 체내 대사)

  • LEE Sang-Min
    • Journal of Aquaculture
    • /
    • v.7 no.1
    • /
    • pp.63-76
    • /
    • 1994
  • The effects of different dietary lipids on growth, body chemical composition, and nutrient partition of the Korean rockfish (43 g of initial mean weight) were studied. Fish were fed three experimental diets containing 1) $4.5\%$ squid liver oil, 2) $1\%$ squid liver oil and $3.5\%$ beef tallow, and 3) $1\%$ squid liver oil and $3.5\%$ soybean oil. Growth and feed efficiency were detarmined during a 19-week feeding period at water temperature of $15.5^{\circ}C$, and at the end of which body chemical compositions were analyzed. Remained fish were fasted for 45 days, and four fish were taken at 6, 12 and 24 hours, and 3, 15 and 45 days after the fasting to determine tissue compositions and hematological changes. Growth, feed efficiency, protein and lipid retention efficiency, hepatosomatic index(HSI), viscerosomatic index (VSI), and chemical composition of whole body and dorsal muscle were not affected by the different dietary lipids. Liver moisture content of fish fed squid liver oil diet was higher than that of fish fed beef tallow or soybean oil diet. Liver lipid content of fish fed beef tallow diet was higher than that of fish fed the other diets. Fatty acid composition of dorsal muscle and liver were affected by the different dietary lipids ; high levels of 20 : 5n-3 and 22 : 6n-3 from fish fed the diet containing squid liver oil, 18 : 1 from fish fed the diet containing beef tallow, and high 18 : 2n-6 and 18 : 3n-3 from fish fed the diet containing soybean oil were observed. Both HSI and VSI of fish fed three diets decreased with time after the begining of starvation. Liver glycogen did not change during the first 15 days of starvation and decreased thereafter, and that was not affected by the different dietary lipids. Lipid and protein contents in the dorsal muscle of fish decreased up to 15 days of starvation and remained unchanged thereafter, these were not different from each other. Glucose, free fatty acid, triglyceride and phospholipid concentrations in Fish serum were varied for the first 15 days of starvation, after that the concentrations of fish serum remained relatively stable in all the treatment groups with prolonged starvation. The results indicate that Korean rockfish can utilize fish oil, animal fat or vegetable oil equally as energy source when n-3HUF A is adquate.

  • PDF

A Review Study on Major Factors Influencing Chlorine Disappearances in Water Storage Tanks (저수조 내 잔류염소 감소에 미치는 주요 영향 인자에 관한 문헌연구)

  • Noh, Yoorae;Kim, Sang-Hyo;Choi, Sung-Uk;Park, Joonhong
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.63-75
    • /
    • 2016
  • For safe water supply, residual chlorine has to be maintained in tap-water above a certain level from drinking water treatment plants to the final tap-water end-point. However, according to the current literature, approximately 30-60% of residual chlorine is being lost during the whole water supply pathways. The losses of residual chlorine may have been attributed to the current tendency for water supply managers to reduce chlorine dosage in drinking water treatment plants, aqueous phase decomposition of residual chlorine in supply pipes, accelerated chlorine decomposition at a high temperature during summer, leakage or losses of residual chlorine from old water supply pipes, and disappearances of residual chlorine in water storage tanks. Because of these, it is difficult to rule out the possibility that residual chlorine concentrations become lower than a regulatory level. In addition, it is concerned that the regulatory satisfaction of residual chlorine in water storage tanks can not always be guaranteed by using the current design method in which only storage capacity and/or hydraulic retention time are simply used as design factors, without considering other physico-chemical processes involved in chlorine disappearances in water storage tank. To circumvent the limitations of the current design method, mathematical models for aqueous chlorine decomposition, sorption of chlorine into wall surface, and mass-transfer into air-phase via evaporation were selected from literature, and residual chlorine reduction behavior in water storage tanks was numerically simulated. The model simulation revealed that the major factors influencing residual chlorine disappearances in water storage tanks are the water quality (organic pollutant concentration) of tap-water entering into a storage tank, the hydraulic dispersion developed by inflow of tap-water into a water storage tank, and sorption capacity onto the wall of a water storage tank. The findings from his work provide useful information in developing novel design and technology for minimizing residual chlorine disappearances in water storage tanks.

A Study on the Optimum Design of Multiple Screw Type Dryer for Treatment of Sewage Sludge (하수슬러지 처리를 위한 다축 스크류 난류 접촉식 건조기의 최적 설계 연구)

  • Na, En-Soo;Shin, Sung-Soo;Shin, Mi-Soo;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.4
    • /
    • pp.223-231
    • /
    • 2012
  • The purpose of this study is to investigate basically the mechanism of heat transfer by the resolution of complex fluid flow inside a sophisticated designed screw dryer for the treatment of sewage sludge by using numerical analysis and experimental study. By doing this, the result was quite helpful to obtain the design criteria for enhancing drying efficiency, thereby achieving the optimal design of a multiple screw type dryer for treating inorganic and organic sludge wastes. One notable design feature of the dryer was to bypass a certain of fraction of the hot combustion gases into the bottom of the screw cylinder, by the fluid flow induction, across the delicately designed holes on the screw surface to agitate internally the sticky sludges. This offers many benefits not only in the enhancement of thermal efficiency even for the high viscosity material but also greater flexibility in the application of system design and operation. However, one careful precaution was made in operation in that when distributing the hot flue gas over the lump of sludge for internal agitation not to make any pore blocking and to avoid too much pressure drop caused by inertial resistance across the lump of sludge. The optimal retention time for rotating the screw at 1 rpm in order to treat 200 kg/hr of sewage sludge was determined empirically about 100 minutes. The corresponding optimal heat source was found to be 150,000 kcal/hr. A series of numerical calculation is performed to resolve flow characteristics in order to assist in the system design as function of important system and operational variables. The numerical calculation is successfully evaluated against experimental temperature profile and flow field characteristics. In general, the calculation results are physically reasonable and consistent in parametric study. In further studies, more quantitative data analyses such as pressure drop across the type and loading of drying sludge will be made for the system evaluation in experiment and calculation.

Performance Evaluation of Bio-Membrane Hybrid Process for Treatment of Food Waste Leachate (음식물 침출수 청정화를 위한 파일롯 규모의 생물-분리막 복합공정의 성능 평가 연구)

  • Lee, Myung-Gu;Park, Chul-Hwan;Lee, Do-Hoon;Kim, Tak-Hyun;Lee, Byung-Hwan;Lee, Jin-Won;Kim, Sang-Yong
    • KSBB Journal
    • /
    • v.23 no.1
    • /
    • pp.90-95
    • /
    • 2008
  • In this study, a combined process of sequential anaerobic-aerobic digestion (SAAD), fluidized-bed bioreactor (FBBR), and ultrafiltration (UF) for the treatment of small scale food waste leachate was developed and evaluated. The SAAD process was tested for performance and stability by subjecting leachate from food waste to a two-phase anaerobic digestion. The main process used FBBR composed of aerators for oxygen supply and fluidization, three 5 ton reaction chambers containing an aerobic mesophilic microorganism immobilized in PE (polyethylene), and a sedimentation chamber. The HRTs (hydraulic retention time) of the combined SAAD-FBBR-UF process were 30, 7, and 1 day, and the operation temperature was set to the optimal one for microbial growth. The pilot process maintained its performance even when the CODcr of input leachate fluctuated largely. During the operation, average CODcr, TKN, TP, and salt of the effluent were 1,207mg/L, 100mg/L, 50 mg/L, and 0.01 %, which corresponded to the removal efficiencies of 99.4%, 98.6%, 89.6%, and 98.5%, respectively. These results show that the developed process is able to manage high concentration leachate from food waste and remove CODcr, TKN, TP, and salt effectively.