• Title/Summary/Keyword: high strength grout

Search Result 71, Processing Time 0.028 seconds

Development of Reinforcement Grout Materials Using Reinforcing Fiber and Blast Furnace Slag Powder (보강섬유와 고로슬래그 미분말 함유량에 따른 차수그라우트재 개발)

  • Seo, Hyeok;Kim, Daehyeon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.3
    • /
    • pp.101-112
    • /
    • 2019
  • The grouting method is utilized to reinforce and waterproof poor grounds, enhance the bearing capacity of geo-structures damaged from differential settlement. The purpose of this research is to improve the compressive strength and degree of grout using reinforcing fibers and blast furnace slag powder. In this regard, this study has conducted uniaxial compression tests for the specimens with high ratios (higher than 50%) of blast furnace slag powder. The carbon fiber content was increased by 0, 0.5, and 1.0% to coMpare its compressive strength with that of aramid fiber. The uniaxial compressive strength increased with the increase of fiber content and the bridging activity by fiber in cement tended to increase uniaxial compressive strength. Based on the results, it was confirmed that the aramid fiber has a gel time of 14 seconds and the uniaxial compressive strength is more than 3 Mpa coMpared to carbon fiber.

A Study on Hybrid Grout Material for Reservoir Embankment reinforcement (저수지 제방 보수보강을 위한 하이브리드형 그라우트재 연구)

  • Park, Sung-Yong;Shim, Houng-Gen;Kang, Hee-Jin;Lim, One-Bin;Sami, Ghazali-Flimban;Kim, Yong-Seong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.3
    • /
    • pp.21-30
    • /
    • 2017
  • Cement grouting method is generally applied for the purpose of reinforcement of deteriorated reservior. Problems have been raised due to the limit of the injection material. In order to solve these problems, various grout materials have been developed. However, there are many cases in which the grounds are disturbed in actual field. In this study, the physical properties of hybrid grout with high fineness and high viscosity characteristics were analyzed to enable penetration into the ground. Optimum inflation agent was selected and mixed with the grout. The pressure and compaction effect on expansion was examined and its effectiveness was verified. From the result of confirming expansion ratio, uniaxial compressive strength, expansion pressure and compaction effect, the HI-E (2%) sample was analyzed to be excellent in improvement effect by the inflation agent. Hence, hybrid grout can be effectively applied for the impermeable and reinforcement method of deterioration reservoir and tide embankment.

Pull-out Characteristics of Multi-Packer Pressurized Soil Nails (가압 그라우팅 쏘일네일링 공법의 인발거동 특성)

  • Cho, Jae-Yeon;Lee, Sung-June;Jeong, Sang-Seom;Ahn, Byeong-Heun
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.2
    • /
    • pp.15-22
    • /
    • 2010
  • A series of field pull-out tests were carried out to investigate the behaviour of multi-pressurized soil nails. Ten soil nails were constructed in weathered soil and then, subjected to pull-out loads. The test results showed that the ultimate pull-out resistances of soil nails constructed with high pressure were about 42~142% larger than those obtained from conventional soil nails. The deduced interface shear strength at the ground-grout interface was 71 kPa for conventional soil nails, while higher shear strength of 95~166 kPa was obtained for pressurized nails. The diameter of grouted borehole increased by about 12~27% compared to ordinary soil nails under low pressure. Also, the predicted value by the cavity expansion theory is in good agreement with the measured expanded radius of grout under injection pressure by field pull-out tests.

Grouting Properties using Thixotropic Material and Vibration Impact Method (가소성 그라우트 재료와 진동 및 충격을 부여하는 공법에 의한 지반개량 특성)

  • Keeseok Kim;Haseog Kim;Bong-hyun Baek;Simhun Yuk
    • Resources Recycling
    • /
    • v.33 no.1
    • /
    • pp.37-47
    • /
    • 2024
  • In grouting, the LW method is commonly employed to induce the gelation of cementitious material using water glass, thereby restricting the extent of material injection. Nevertheless, challenges manifest when materials are lost before gelation, particularly in regions with high groundwater flow rates or significant subsurface voids. This study developed a thixotropic grout material using LFS and GGBFS to mitigate material loss during injection, with an assessment of its flow characteristics, durability in marine exposure, strength, and injection properties. The outcomes revealed that the thixotropic grout material exhibited flow ranging from 105 to 143 mm and enhanced strength and durability compared to the LW method. Furthermore, field tests substantiated that applying vibration and impact improved impermeability.

Evaluating Shrinkage Characteristic of Ternary Grout for PSC Bridge Using Expansive Additive and Shrinkage Reducing Agent (팽창재 및 수축저감제를 이용한 PSC 교량용 3성분계 그라우트의 수축특성 평가)

  • Yuan, Tian-Feng;An, Gi-Hong;Ryu, Gum-Sung;Koh, Kyoung-Taek;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.5
    • /
    • pp.519-525
    • /
    • 2016
  • This paper reports on analyzing the free and restrained shrinkage characteristic of ternary grout used cementitious admixture. In this study, the cementitious admixture was used such as fly ash, ziricania silica fume by combination of expansive additive (a, b) and shrinkage reducing agent. And a number of basic performance tests were conducted to investigate bleeding, volume change, fluidity and compressive strength behavior. According to the results, within appropriate mixing ratio, even the fluidity is not influenced by expansive additive and shrinkage reducing agent, the resistant properties of bleeding, volume change, shrinkage and compressive strength are increased. Comparing with plain grout, the free shrinkage reduced by a minimum of 29% which specimens are added expansive additive and shrinkage reducing agent. The combination of expansive additive a and shrinkage reducing agent is the most effective for reduction of shrinkage. And increasing the mixing ratio of expansive additive and shrinkage reducing agent extended cracking time. Nevertheless, combined addition of expansive additive a 2.0% and shrinkage reducing agent 0.50% has best shrinkage reduction behavior and not appeared cracking. From the above, the mixing ratio of 2.0% of expansive additive a and 0.50% of shrinkage reducing agent is high performance ternary grout for PSC bridge.

Evaluation of Field Application for the mix properties of the thixotropic grout (가소성그라우트의 배합특성 및 현장 적용성 평가)

  • Kim, Hak-Moon;Jang, Kyung-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.9
    • /
    • pp.4223-4238
    • /
    • 2011
  • The advantages of grouting are the simple instrument, the simple procedure of practice and the simple verification of grouting result. but the more grouting practice there is, the more damages of environment from grouting practice and grouting materials there are. so, the grouting materials and methods with the character of environment friendly are introduced in construction field, recently. This paper is to study of the physical characteristics that has thixotropic character and that consists of inorganic and polycarboxylate co-polymer. In study, various testing methods are performed such as a viscosity, a thixotropy, a compressive strength, a heavy metal detection and pH measurement in lab test and a low pressure injection test and a high pressure injection test in field with different soil type. As a result, a optimum mix ratio is proposed by analyzing the result of lab test. the field applicability is verified by checking a injection pressure, a grout volume and a hardened body of grout by excavating the practice site.

Characteristics of High-viscosity Grouting Materials for Rock Joint Reinforcement of Deep Tunnel (대심도 터널 암반 절리 보강을 위한 고점도 그라우팅 재료의 특성)

  • Yoon, Inkook;Moon, Junho;Lee, Junsu;Kim, Younguk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.12
    • /
    • pp.59-63
    • /
    • 2021
  • This study presented the characteristics and additive effects of the grout with mixing ratio for developing of high-efficiency grouting technology under high depth conditions. The laboratory investigation were conducted with Portland cement (OPC) and micro cement (S8000-E) including viscosity experiments, particle size analysis experiments, Gel-Time experiments and uniaxial compressive strength experiments. As a result of the viscosity experiment, it was shown that OPC is advantageous in terms of viscosity, but S8000-E is suitable when considering the passage of rock joint intervals through particle size analysis. The Gel-Time experiment shows that it is not that difficult with injection as a grout material even when silica fume (SF) was applied. The strength of the cured material is improved as increase in the content of silica fium (SF). Within the range of the study, the optimal mixing ratio obtained through various experiments is S8000-E, w/c=70%, silica fium (SF)=6%, and 7 days.

Effectiveness of CFRP jackets in post-earthquake and pre-earthquake retrofitting of beam-column subassemblages

  • Tsonos, Alexander G.
    • Structural Engineering and Mechanics
    • /
    • v.27 no.4
    • /
    • pp.393-408
    • /
    • 2007
  • This paper presents the findings of an experimental study to evaluate retrofit methods which address particular weaknesses that are often found in reinforced concrete structures, especially older structures, namely the lack of the required flexural and shear reinforcement within the columns and the lack of the required shear reinforcement within the joints. Thus, the use of a high-strength fiber jacket for cases of post-earthquake and pre-earthquake retrofitting of columns and beam-column joints was investigated experimentally. In this paper, the effectiveness of the two jacket styles was also compared.

Development of Steel Pipe Splice Sleeve for High Strength Reinforcing Bar(SD500) and Estimation of its Structural Performance under Monotonic Loading (SD500 고강도 철근용 강관 스플라이스 슬리브 철근이음 개발 및 구조성능 평가)

  • Lee, Sang-Ho;Kim, Hyong-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.6
    • /
    • pp.169-180
    • /
    • 2007
  • Among several splicing system of reinforcing bar, the grout-filled splice sleeve system has been applied widely. However, as the splice sleeve for high strength rebar as SD500 is not yet made in korea, the development of splice sleeve for high strength reinforcing bar are required as soon as possible. It is the purpose of this study to develop the steel pipe sleeve for high strength rebar as SD500 and estimate its structural performance by monotonic loading test. The experimental variables adopted in this study are the development length of rebars, types of sleeve etc. The results of this study showed that the developed steel pipe splice sleeve system for high strength reinforcing bar as SD500 retained the structural performance required in domestic, ACI and AIJ criteria. And it is considered that the study result presented in this paper can be helpful in developing reasonable design method of steel pipe splice sleeve system for high strength reinforcing bar as SD500.

Experimental Study on Behavior of Bonding between PSC Girders and Precast Decks (PSC 거더와 프리캐스트 바닥판간 부착 강도 평가를 위한 실험적 연구)

  • Kim In Gyu;Chung Chul Hun;Shim Chang Su;Kim Seong Woon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.770-773
    • /
    • 2004
  • The full-width, full-depth precast panel system is very efficient for the rehabilitation of deteriorated decks as well as for new bridge construction.. The horizontal bond strength at the interface between the two interconnected elements is of primary importance in order to achieve composite action. The strength of the bond between the two precast members should be high enough to prevent any progressive slip from taking place. However, the case when both of the interconnected elements are precast members bonded by means of grout, is not currently addressed by KBDC or AASHTO. This is the main impetus for this study. A total 43 push-off tests were performed to evaluate the horizontal bond strength and to recommend the best practice for the system. Test parameters included different interface surface conditions, different amount and different types of shear connectors. The presence of the shear keys at the top surface of the beam increased the interface bond capacity tremendously compared to the bond capacity with a different surface conditions.

  • PDF