• 제목/요약/키워드: high sensitivity

검색결과 4,990건 처리시간 0.033초

결정소성 유한요소법을 이용한 FCC 다결정 금속의 압연 집합조직 예측 (Prediction of Rolling Texture Evaolution in FCC Polycrystalline Metals Using Finite Element Method of Crystal Plasticity)

  • 박성준;조재형;한흥남;오규환
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1999년도 제3회 압연심포지엄 논문집 압연기술의 미래개척 (Exploitation of Future Rolling Technologies)
    • /
    • pp.313-319
    • /
    • 1999
  • The development of deformation texture in FCC polycystalline metals during rolling was simulated by the finite element analysis using a large-deformation, elaatic-plastic, rate-dependent polycrystalline model of crystal plasticity. Different plastic anisotropy due to different orientation of each crystal makes inhomogeneous deformation. Assuming plane strain compression condition, the simulation with a high rate sensitivity resulted in main component change from Dillamore at low rate sensitivity to Brass component.

  • PDF

실험을 통한 소형 고감도 광섬유 하이드로폰의 감지성능 연구 (Experimental Study on Signal Sensing of a High Sensitive Fiber Optic Hydrophone)

  • 김정석;윤형규;설재수
    • 소음진동
    • /
    • 제9권6호
    • /
    • pp.1152-1156
    • /
    • 1999
  • In this study, a fiber optic air-backed mandrel hydrophone has been constructed and performance of acoustic signal detection has been measured. The hydrophone is based on a Mach-Zehnder interferometer with 35 m of sensing fiber. The sensitivity is measured up to -128 dB re rad/$\mu$ Pa in range from 1.4 kHz to5 kHz. A system with this design of hydrophone may be applied to detect low frequency underwater acoustic signals.

  • PDF

고충격 미소가속도계의 압저항-구조 연성해석 및 최적설계 (Piezoresistive-Structural Coupled-Field Analysis and Optimal Design for a High Impact Microaccelerometer)

  • 한정삼;권순재;고종수;한기호;박효환;이장우
    • 한국군사과학기술학회지
    • /
    • 제14권1호
    • /
    • pp.132-138
    • /
    • 2011
  • A micromachined silicon accelerometer capable of surviving and detecting very high accelerations(up to 200,000 times the gravitational acceleration) is necessary for a high impact accelerometer for earth-penetration weapons applications. We adopted as a reference model a piezoresistive type silicon micromachined high-shock accelerometer with a bonded hinge structure and performed structural analyses such as stress, modal, and transient dynamic responses and sensor sensitivity simulation for the selected device using piezoresistive-structural coupled-field analysis. In addition, structural optimization was introduced to improve the performances of the accelerometer against the initial design of the reference model. The design objective here was to maximize the sensor sensitivity subject to a set of design constraints on the impact endurance of the structure, dynamic characteristics, the fundamental frequency and the transverse sensitivities by changing the dimensions of the width, sensing beams, and hinges which have significant effects on the performances. Through the optimization, we could increase the sensor sensitivity by more than 70% from the initial value of $0.267{\mu}V/G$ satisfying all the imposed design constraints. The suggested simulation and optimization have been proved very successful to design high impact microaccelerometers and therefore can be easily applied to develop and improve other piezoresistive type sensors and actuators.

우리 나라 노인의 영양부족위험 진단을 위해 개발된 간이조사표의 타당성 평가 (Evaluation of the Validity of a Simple Screening Test Developed for Identifying Korean Elderly at Risk of Undernutrition)

  • 이정원;김경은;김기남;현태선;현화진;박영숙
    • Journal of Nutrition and Health
    • /
    • 제33권8호
    • /
    • pp.864-872
    • /
    • 2000
  • This study intended to evaluate the validity of the simple nutrition screening test that had been developed with the elderly living in Cheongju as a subject. Nutrition screening score(NSS) and reference standards for nutritional and health status(nutrient intakes, mean adequacy ratio, perceive health, and serum albumin, hematocrit, and hemoglobin) were estimated by using the date obtained in 1996 from the 174 elderly living in Taejon, Statistical analysis showed significant correlations between mean adequacy ratio(MAR) and NSS(r=0.341) and also between NSS and biological indices such as albumin and hematocrit, Around 65-75% of the elderly with perceive health and low level of serum albumin, hemoglobin and hematocrit had NSS$\leq$ll. Sensitivity, specificity, and positive predictive values(PPV) were calculated from the crosstabulation of the three categories of NSS(high, moderate, and low nutritional risk) and low categories MAR(< 0.75, undernutrition;$\geq$0.75, normal) to validate the cut-off point for high or low nutritional risk by NSS. It was suggested that point l1 was appropriate as a criterion to determine high risk of undernutrition, but point 16 was better than 17 as criterion to determine low nutritional risk in the Taejon elderly. When point ll was used as a criterion of high nutritional risk, sensitivity, specificity, and PPV are 59.5, 60.5 and 82.1 respectively. When point 16 was used as a criterion of low nutritional risk, sensitivity, specificity, and PPV are 25.6, 95.4, and 64.7%, respectively. In conclusion, nutrition screening test that had been developed can be a simple, easy, and proper instrument to classify the high risk group of undernutrition. A further validation study seems to be required among other groups of individuals for the screening test to the finalized as a more valid instrument identifying Korean elderly at nutrition and health risk(Korean J Nutrition 33(8) : 864-872, 2000)

  • PDF

Analysis of Flux Observers Using Parameter Sensitivity

  • Nam H.T.;Lee K.J.;Choi J.W.;Kim H.G.;Chun T.W.;Noh E.C.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.418-422
    • /
    • 2001
  • To achieve a high performance in direct vector control of induction motor, it is essential to correct estimation of rotor flux. The accuracy of flux observers for induction machines inherently depends on parameter sensitivity. This paper presents an analysis method for conventional flux observers using Parameter Sensitivity. The Parameter sensitivity is defined as the ratio of the percentage change in the system transfer function to the percentage change of the parameter variation. We define the ratio between real flux and estimated flux as the transfer function, and analyzed a parameter sensitivity of this transfer function by simulation.

  • PDF

보육시설에서의 영아-교사 상호작용과 영아의 발달수준, 교사의 민감성 및 초기 가정환경 간의 관련성에 관한 연구 (Infant-Child Care Teacher Interaction : Infant Development, Teachers' Sensitivity and Early Home Environment)

  • 최은정;하지영;서소정
    • 아동학회지
    • /
    • 제30권2호
    • /
    • pp.71-95
    • /
    • 2009
  • This study investigated relationships among infant development, teacher's sensitivity, home literacy environment, and infant-teacher interaction in the child care setting. Verbal and behavioral interactions between 30 2-year-old infant-teacher pairs were video-recorded during free play activities; teachers' sensitivity was observed by trained observers; infant development was assessed by teachers; data on the early home literacy environment were gathered through maternal self-reported questionnaires. Data were analyzed by descriptive statistics, t-tests, and correlation analyses. Results indicated that boys showed more naming; girls showed more physical contact with teachers. Infants high in overall developmental level showed more behavioral interaction with teachers. Teacher's sensitivity correlated positively with behavioral imitating and negatively with questioning and nodding. Verbal interaction in the home correlated positively with nodding.

  • PDF

파라메터 민감도를 이용한 유도전동기 자속 추정기 해석 (Analysis of Induction Motor Flux Observer using Parameter Sensitivity)

  • 남현택;이경주;김진규;최영태;최종우;김흥근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1176-1178
    • /
    • 2001
  • To obtain a high performance in a direct vector controlled induction machine, it is essential to correct estimation of rotor flux. The accuracy of flux observers for induction machines inherently depends on parameter sensitivity. This paper presents an analysis method for conventional flux observers using parameter Sensitivity. The Parameter sensitivity is defined as the ratio of the percentage change in the system transfer function to the percentage change of the parameter variation. We define the ratio between real flux and estimated flux as the transfer function, and analyzed a parameter sensitivity of this transfer function.

  • PDF

A PDMS-Coated Optical Fiber Bragg Grating Sensor for Enhancing Temperature Sensitivity

  • Park, Chang-Sub;Joo, Kyung-Il;Kang, Shin-Won;Kim, Hak-Rin
    • Journal of the Optical Society of Korea
    • /
    • 제15권4호
    • /
    • pp.329-334
    • /
    • 2011
  • We proposed a poly-dimethylsiloxane (PDMS)-coated fiber Bragg grating (FBG) temperature sensor for enhancing temperature sensitivity. By embedding the bare FBG in a temperature-sensitive elastomeric polymer, the temperature sensitivity of the proposed structure could be effectively improved by 4.2 times higher than those of the conventional bare-type FBG sensors due to the high thermal expansion coefficient of the PDMS. We analyzed the temperature-sensitivity enhancement effect with the increased Bragg wavelength shift in our structure and dependence on the temperature sensitivity with respect to the cross-section area of the PDMS.

Comparative Efficacy of Four Imaging Instruments for Breast Cancer Screening

  • Mehnati, Parinaz;Tirtash, Maede Jafari
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권15호
    • /
    • pp.6177-6186
    • /
    • 2015
  • Sensitivity and specificity are the two most important indicators in selection of medical imaging devices for cancer screening. Breast images taken by conventional or digital mammography, ultrasound, MRI and optical mammography were collected from 2,143,852 patients. They were then studied and compared for sensitivity and specificity results. Optical mammography had the highest sensitivity (p<0.001 and p<0.006) except with MRI. Digital mammography had the highest specificity for breast cancer imaging. A comparison of specificity between digital mammography and optical mammography was significant (p<0.021). If two or more breast diagnostic imaging tests are requested the overall sensitivity and specificity will increase. In this literature review study patients at high-risk of breast cancer were studied beside normal or sensitive women. The image modality performance of each breast test was compared for each.

신뢰성 지수의 민감도 해석을 이용한 신뢰성에 기초한 최적설계 (Reliability-Based Optimization using Sensitivity Analysis of Reliability Index)

  • 조효남;민대홍;권우성
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2000년도 가을 학술발표회논문집
    • /
    • pp.101-108
    • /
    • 2000
  • An optimum design algorithm using efficient reanalysis is proposed for reliability-based optimization problems formulated as the minimization of initial cost and expected failure cost with reliability constraints. The reliability-based optimization is high cost to evaluate objective function and constraints needed reliability analysis. Therefore the sensitivity analysis of reliability index for approximated reanalysis is necessary. In this paper, three solution approaches are suggested and tested. The approaches include : (1) sensitivity analysis using finite difference; (2) sensitivity analysis using automatic differentiation (AD); and (3) sensitivity analysis with respect to intermediate variables using AD. Numerical example is optimized to show the reliability and effectiveness of the new algorithm.

  • PDF