• Title/Summary/Keyword: high reliability

Search Result 6,440, Processing Time 0.043 seconds

Motion Characteristic Evaluation of Sliding Cover for High Speed Type Machine (Sliding cover의 고속 운동 특성 평가)

  • 강재훈;송준엽;박화영;이승우;황주호;이현용;이찬홍;이후상
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.446-449
    • /
    • 2002
  • Recently, advanced manufacturing system with high speed and intelligent have been developed for the betterment of machining ability. In this case, reliability prediction work with motion characteristic evaluation of sliding cover has also important roll from design procedure to manufacturing and assembly process. Accordingly in this study, H/W test -bed system for reliability evaluation of sliding cover has been developed to obtain proper reference data for design of new model, and also prevention trouble, quality and life cycle improvement extremely for advanced mother machinary.

  • PDF

Assessment Methodology of Junction Temperature of Light-Emitting Diodes (LEDs)

  • Chang, Moon-Hwan;Pecht, Michael
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.3
    • /
    • pp.7-14
    • /
    • 2016
  • High junction temperature directly or indirectly affects the optical performance and reliability of high power LEDs in many ways. This paper is focused on junction temperature characterization of LEDs. High power LEDs (3W) were tested in temperature steps to reach a thermal equilibrium condition between the chamber and the LEDs. The LEDs were generated by pulsed currents with duty ratios (0.091% and 0.061%) in multiple steps from 0mA and 700mA. The diode forward voltages corresponding to the short pulsed currents were monitored to correlate junction temperatures with the forward voltage responses for calibration measurement. In junction temperature measurement, forward voltage responses at different current levels were used to estimate junction temperatures. Finally junction temperatures in multiple steps of currents were estimated in effectively controlled conditions for designing the reliability of LEDs.

Evaluation of ENEPIG Surface Treatment for High-reliability PCB in Mobile Module

  • Lee, Joon-Kyun;Yim, Young-Min;Seo, Jun-Ho
    • Journal of the Korean institute of surface engineering
    • /
    • v.43 no.3
    • /
    • pp.142-147
    • /
    • 2010
  • We evaluated characteristics of ENEPIG (Electroless Nickel Electroless Palladium Immersion Gold) surface treatment for mobile equipment that requires high reliability, in addition to investigating surface treatment processes for semiconductor boards that require high reliability such as regular PCB-package systems, board-on-chip, chip-scaled package (CSP), etc and application for semiconductor package board of SIP, BOC. As a result, it appeared that ENEPIG has superior properties compared to ENIG surface treatment in corrosion resistance, solder junction, wetting, etc. We anticipate that these results will be able to lend credibility to ENEPIG as a low-cost alternative for producing mobile devices such as the cell phones, especially when applied to mass production.

The estimation of uncertainty in high-voltage measuring system used in high-power tests (대전력시험에서 고전압 측정시스템의 불확도 평가)

  • Suh, Yoon-Taek;Kim, Maeng-Hyun;Kim, Dae-Won;Jeong, Joo-Young;Kang, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.348-350
    • /
    • 2002
  • In the high-power tests to be performed on electrical apparatus as switchgears, transformers, insulators, cable and so on the results of tests on these apparatus are extremely important to evaluate the performance of test object. The reliability of the results depends on the reliability of measuring systems used in the laboratories where tests are performed. This paper introduces factors of uncertainty and describes estimation of uncertainty in high-voltage measuring system used in high-power testing LAB. 1 in KERI.

  • PDF

Reliability and Validity of the Measurement of Pelvic Movement in Low Back Pain Patients using Cushion Sensor in Sitting Position (앉은 자세에서 방석센서를 이용한 요통환자 골반가동성 측정의 신뢰도와 타당도)

  • Jung, Seung-Hwa;Park, Dae-Sung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.15 no.2
    • /
    • pp.83-91
    • /
    • 2020
  • PURPOSE: Postural and structural asymmetry due to muscle imbalances around the lower back and pelvis are the causes of back pain. Muscle imbalances in patients with chronic low back pain affect the pelvic tilt and movement, and it is necessary to assess the pelvic movement ability using the appropriate tools to determine the mediating effects of lower back pain. This paper reports the reliability and validity of the Sensbalance Therapy Cushion (STC) for pelvic movement and proprioception. METHODS: In this study, the Wii balance board (WBB) was used as a golden standard for pelvic movement measurements. FABQ, KODI, Myovision, and Pelvic movement were measured in 50 patients with chronic low back pain. The correlation between the lower-back muscle activity and pelvic movement was checked. The pelvic movement parameter was measured twice to determine the intra-rater reliability. RESULTS: The STC showed high test-retest reliability in the pelvic tilt measurements (ICC = .672 - .809). The test-retest reliability of proprioception measurements (ICC = .588 - .859) and reaction time measurements (ICC = .542 - .836) were also high. The relationship between the WBB and STC showed a significant positive correlation with the pelvic tilt test (p < .01). The posterior pelvic tilt and lower-back muscle activity showed a significant negative correlation (p < .01). The pelvic left tilt and lower-back muscle activity showed a significant negative correlation (p < .05). CONCLUSION: The results revealed the high reliability and validity of the STC. Therefore, the STC can be used as an objective measuring device for evaluating pelvic tilt, proprioception, and reaction time in low back pain patients.

Test-Retest Reliability of a Questionnaire for the Korea Youth Risk Behavior Web-Based Survey

  • Bae, Ji-Suk;Joung, Hyo-Jee;Kim, Jong-Yeon;Kwon, Kyoung-Nam;Kim, Young-Taek;Park, Soon-Woo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.43 no.5
    • /
    • pp.403-410
    • /
    • 2010
  • Objectives: A web-based survey has been administered annually since 2005 throughout Korea to assess the prevalence of adolescent health risk behaviors among middle and high school students. The aim of this study was to evaluate the test-retest reliability of the Korea Youth Risk Behavior Web-based Survey (KYRBWS) questionnaire. Methods: A convenience sample of 2298 middle and high school students participated in self-administered questionnaire surveys twice, approximately two weeks apart, in 2008. The percent agreement, kappa statistics, and prevalence rates at the first and second surveys were computed for the core subset of 39 self-reported health risk behavior indices of the KYRBWS. Results: Among 39 indices, seven indices had kappas $\geq$ 0.81 and all of the indices had kappas $\geq$ 0.41. Based on nonoverlapping 95% confidence intervals, three indices had significantly different prevalence rates between the first and second surveys. In the subgroup analyses by school grade and gender, two indices had significantly different reliability estimates between middle and high school students. There were no significantly different reliability estimates between male and female students, except for one index. Conclusions: This study demonstrated that the reliability estimates for the KYRBWS questionnaire are varied, but generally reliable over time. The indices with low reliability estimates need to be evaluated further in order to determine whether the indices should be modified or deleted from future versions of the KYRBWS.

The Validity and Reliability of the Second Korean Working Conditions Survey

  • Kim, Young Sun;Rhee, Kyung Yong;Oh, Min Jung;Park, Jungsun
    • Safety and Health at Work
    • /
    • v.4 no.2
    • /
    • pp.111-116
    • /
    • 2013
  • Background: The aim of this study was to evaluate the quality of the Second Korean Working Conditions Survey (KWCS), focusing on its validity and reliability. Methods: The external validity was evaluated by the assessment of sampling procedures and the response rate, in order to investigate the representativeness of the sample. The content validity was evaluated by the assessment of the development of the questionnaire, and the consistency of questions for the selected construct. The test-retest method was used to evaluate the reliability by means of a phone call survey of 30% of the respondents, who were randomly selected. The respondents' satisfaction regarding the survey procedures and interview time were analyzed to evaluate the quality of survey data. Results: The external validity was assured by an acceptable sampling procedure, rigid multi-stage stratified cluster random sampling. The content validity was also guaranteed by a reasonable procedure for the development of the questionnaire with a pretest. The internal consistency of the questions for work autonomy was maintained, with 0.738 of Cronbach's alpha. The response rate of 36% was lower than that of the European Working Conditions Survey (EWCS), with a contact rate of 66%, compared to 76% for the EWCS. The matching rates of the five retested questions were more than 98% reliable. Conclusion: The quality of the second KWCS was assured by the high external and content validity and reliability. The rigid sampling procedure and development of the questionnaire contributed to quality assurance. The high level of reliability may be guaranteed by the sophisticated field survey procedures and the development of a technical manual for interviewers. The technical strategies for a high response rate should be developed for future surveys.

Validity and Reliability of New Digital Navicular Drop Test Equipment in Young People

  • Park, Jin-Seong;Park, Du-Jin
    • PNF and Movement
    • /
    • v.19 no.2
    • /
    • pp.279-285
    • /
    • 2021
  • Purpose: This study aimed to develop new digital navicular drop test (ND-NDT) equipment and to determine its validity and reliability. Methods: A total of 24 healthy male and female adults, who fully understood the purpose of the study and gave consent to participate in the study, were selected as participants. The NDT and ND-NDT were conducted in the dominant foot of the participants in a random order. For the NDT, the position of the navicular bone was marked with a pen first; then, the height of the navicular bone from the ground was measured in both sitting and standing positions. For the ND-NDT, after the sticker-type reflection markers were attached to the position of the navicular bone, the height of the navicular bone from the ground was measured in both sitting and standing positions. To assess the validity of the diagnostic tests, the same examiner measured the height of the medial longitudinal arch (MLA) three times in both the sitting and standing positions. To assess the inter-rater reliability of the ND-NDT, three examiners, in a random order, attached the sticker-type reflection markers to the position of the navicular bone and then measured the height of the MLA in both positions. Results: In the sitting position, the Pearson correlation coefficient (r) between the two diagnostic tests was very high (r = 0.97) and statistically significant. In the standing position, the Pearson correlation coefficient (r) between the two tests was 0.95, which was also statistically significant. The ICC2,1 values in the sitting and standing positions were 0.93 and 0.95, respectively, indicating significantly high inter-rater reliability. Conclusion: The ND-NDT equipment showed very high diagnostic validity, as well as excellent inter-rater reliability, indicating the clinical usefulness of the equipment as a diagnostic system for confirming pes planus.

Experimental approach to evaluate software reliability in hardware-software integrated environment

  • Seo, Jeongil;Kang, Hyun Gook;Lee, Eun-Chan;Lee, Seung Jun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1462-1470
    • /
    • 2020
  • Reliability in safety-critical systems and equipment is of vital importance, so the probabilistic safety assessment (PSA) has been widely used for many years in the nuclear industry to address reliability in a quantitative manner. As many nuclear power plants (NPPs) become digitalized, evaluating the reliability of safety-critical software has become an emerging issue. Due to a lack of available methods, in many conventional PSA models only hardware reliability is addressed with the assumption that software reliability is perfect or very high compared to hardware reliability. This study focused on developing a new method of safety-critical software reliability quantification, derived from hardware-software integrated environment testing. Since the complexity of hardware and software interaction makes the possible number of test cases for exhaustive testing well beyond a practically achievable range, an importance-oriented testing method that assures the most efficient test coverage was developed. Application to the test of an actual NPP reactor protection system demonstrated the applicability of the developed method and provided insight into complex software-based system reliability.

Human Reliability Analysis for Risk Assessment of Nuclear Power Plants (원자력발전소 위험도 평가를 위한 인간신뢰도분석)

  • Jung, Won-Dea;Kim, Jae-Whan
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.1
    • /
    • pp.55-64
    • /
    • 2011
  • Objective: The aim of this paper is to introduce the activities and research trends of human reliability analysis including brief summary about contents and methods of the analysis. Background: Various approaches and methods have been suggested and used to assess human reliability in field of risk assessment of nuclear power plants. However, it has noticed that there is high uncertainty in human reliability analysis which results in a major bottleneck for risk-informed activities of nuclear power plants. Method: First and second generation methods of human reliability analysis are reviewed and a few representative methods are discussed from the risk assessment perspective. The strength and weakness of each method is also examined from the viewpoint of reliability analyst as a user. In addition, new research trends in this field are briefly summarized. Results: Human reliability analysis has become an important tool to support not only risk assessment but also system design of a centralized complex system. Conclusion: Human reliability analysis should be improved by active cooperation with researchers in field of human factors. Application: The trends of human reliability analysis explained in this paper will help researchers to find interest topics to which they could contribute.