• Title/Summary/Keyword: high rate

Search Result 28,236, Processing Time 0.051 seconds

Optimum Feeding Rates for Growing and Sub-adult Olive Flounder Paralichthys olivaceus Fed Practical Extruded Pellets at High Water Temperature (고수온에서 사육한 성장기 및 미성어기 넙치(Paralichthys olivaceus)의 배합사료 적정 공급률)

  • Kim, Sung-Sam;Kim, Kang-Woong;Kim, Kyoung-Duck;Lee, Bong-Joo;Han, Hyon-Sob;Lee, Kyeong-Jun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.48 no.5
    • /
    • pp.681-687
    • /
    • 2015
  • We investigated the effects of feeding rate on the growth performance of growing and sub-adult olive flounder Paralichthys olivaceus, and the optimum feeding rate at high water temperature (25-31℃). In experiment I, two replicated groups of fish (113 g) were fed a commercial diet (CD) at rates of 0, 0.7, 1.2, 1.7, 2.2, and 2.4% (satiation) body weight (BW) per day for 4 weeks. In experiment II, two replicated groups of fish (313 g) were fed a CD feeding rates of 0, 0.3, 0.5, 0.7, 0.9, and 1.0% (satiation) BW per day for 4 weeks. In experiment I, the weight gain (WG) and specific growth rate (SGR) of fish fed at 0.7 and 0.9% BW per day was significantly higher than that of unfed fish (0%) and fish fed at 0.3, 0.5, and 1.0% (satiation) BW per day. In experiment II, the WG and SGR increased significantly as feeding rate increased from 0 to 2.2% BW per day, but decreased in the satiation group (2.4%). Broken-line regression analysis of WG showed that the optimum feeding rate of growing and sub-adult olive flounder were 1.98% and 0.55% BW per day, respectively, at the high water temperature.

Study on Fast HEVC Encoding with Hierarchical Motion Vector Clustering (움직임 벡터의 계층적 군집화를 통한 HEVC 고속 부호화 연구)

  • Lim, Jeongyun;Ahn, Yong-Jo;Sim, Donggyu
    • Journal of Broadcast Engineering
    • /
    • v.21 no.4
    • /
    • pp.578-591
    • /
    • 2016
  • In this paper, the fast encoding algorithm in High Efficiency Video Coding (HEVC) encoder was studied. For the encoding efficiency, the current HEVC reference software is divided the input image into Coding Tree Unit (CTU). then, it should be re-divided into CU up to maximum depth in form of quad-tree for RDO (Rate-Distortion Optimization) in encoding precess. But, it is one of the reason why complexity is high in the encoding precess. In this paper, to reduce the high complexity in the encoding process, it proposed the method by determining the maximum depth of the CU using a hierarchical clustering at the pre-processing. The hierarchical clustering results represented an average combination of motion vectors (MV) on neighboring blocks. Experimental results showed that the proposed method could achieve an average of 16% time saving with minimal BD-rate loss at 1080p video resolution. When combined the previous fast algorithm, the proposed method could achieve an average 45.13% time saving with 1.84% BD-rate loss.

A Study of New Technique Development for Creep Evaluation of Heat Resistant Steel Weldment(I) (내열강 용접부의 크리프 평가 신기술 개발에 관한 연구)

  • 유효선;백승세;권일현;이송인
    • Journal of Welding and Joining
    • /
    • v.20 no.6
    • /
    • pp.30-30
    • /
    • 2002
  • It has been reported that the creep characteristics on weldment which is composed of weld metal(W.M), fusion line(F.L), heat-affected zone(HAZ), and base meta(B.M) could be unpredictably changed in severe service conditions such as high temperature and high pressure. However, the studies done on creep damage in power plant components have been mostly conducted on B.M and not the creep properties of the localized microstructures in weldment have been thoroughly investigated yet. In this paper, it is investigated the creep characteristics for three microstructures like coarse-grain HAZ(CGHAZ), W.M, and B.M in X20CrMoV121 steel weldment by the small punch-creep-(SP-Creep) test using miniaturized specimen(l0×10×0.5mm). The W.M microstructure possesses the higher creep resistance and shows lower creep strain rate than the B.M and CGHAZ. In the lower creep load the highest creep strain rate is exhibited in CGHAZ, whereas in the higher creep load the B.M represents the high creep strain rate. The power law correlation for all microstructures exists between creep rate and creep load at 600℃. The values of creep load index (n) based on creep strain rate for B.M, CGHAZ, and W.M are 7.54, 4.23, and 5.06, respectively and CGHAZ which shows coarse grains owing to high welding heat has the lowest creep loade index. In all creep loads, the creep life for W.M shows the highest value.

High Rate Dissolved Air Flotation (DAF) for the Removal of Algae Species (유입원수 조류제거를 위한 high rate DAF 최적화 연구)

  • Jung, Woosik;An, Ju-Suk;Song, Keun-Won;Oh, Hyun-Je
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.5
    • /
    • pp.415-419
    • /
    • 2017
  • In recent years there have been large increases in the hydraulic loading rates used to design dissolved air flotation (DAF) facilities for drinking water applications. High rate DAF processes are now available at loading rates of 20 to $40m^3/m^2{\cdot}h$. This research evaluated dissolved air flotation as a separation method for algae and organic compounds from water treatment plants. During the service period of 2016. 5. to 2017. 6., DAF pilot plants ($500m^3/day$) process has shown a constantly sound performance for the treatment of raw water, yielding a significantly low level of turbidity (DAF treated water, 0.21~1.56 NTU). As a result of analyzing the algae cell counts in the influent source, it was expressed at 100-120 cells/mL. In DAF treated water, the removal efficient of alge cell counts was found to be upto 90%. The stable turbidity and algae removal were confirmed by operating the high rate DAF process under the condition of the surface loading rate of $30m^3/m^2{\cdot}hr$.

A Study on New Technique Development for Creep Evaluation of Heat Resistant Steel Weldment (I) (내열강 용접부의 크리프 평가 신기술 개발에 관한 연구(I))

  • 유효선;백승세;권일현;이송인
    • Journal of Welding and Joining
    • /
    • v.20 no.6
    • /
    • pp.754-761
    • /
    • 2002
  • It has been reported that the creep characteristics on weldment which is composed of weld metal(W.M), fusion line(F.L), heat-affected zone(HAZ), and base meta(B.M) could be unpredictably changed in severe service conditions such as high temperature and high pressure. However, the studies done on creep damage in power plant components have been mostly conducted on B.M and not the creep properties of the localized microstructures in weldment have been thoroughly investigated yet. In this paper, it is investigated the creep characteristics for three microstructures like coarse-grain HAZ(CGHAZ), W.M, and B.M in X20CrMoV121 steel weldment by the small punch-creep-(SP-Creep) test using miniaturized specimen($10{\times}10{\times}0.5mm$). The W.M microstructure possesses the higher creep resistance and shows lower creep strain rate than the B.M and CGHAZ. In the lower creep load the highest creep strain rate is exhibited in CGHAZ, whereas in the higher creep load the B.M represents the high creep strain rate. The power law correlation for all microstructures exists between creep rate and creep load at $600^{\circ}C$. The values of creep load index (n) based on creep strain rate for B.M, CGHAZ, and W.M are 7.54, 4.23, and 5.06, respectively and CGHAZ which shows coarse grains owing to high welding heat has the lowest creep loade index. In all creep loads, the creep life for W.M shows the highest value.

The Effect of Absorption Water on Thermal Properties of Pure Linen and Linen Blended Woven Fabrics (마직물 및 마혼방직물의 온열특성에 대한 흡습의 영향)

  • Kwon, Oh-Kyung;Yi, Chang-Mi;Sung, Woo-Kyung
    • Fashion & Textile Research Journal
    • /
    • v.1 no.2
    • /
    • pp.160-165
    • /
    • 1999
  • The thermal properies of the pure linen fabrics available in the market and linen blended woven fabrics were measured at the moisture content of 0%, 20%, 40% and 60% using KES-F7 system (Thermo Iabo II type). The experimental properties were statistically analyzed by the rate of water absorbent. The main results were as follows; There is a positive correlation between the thermal insulation value (TIV) and thickness of pure linen fabrics and linen blended woven fabrics by water absorption. Whereas an negative correlation exists between the TIV and cover factor. There is a high positive correlation among the thermal conductivity (k), thickness and weight of pure linen fabrics and linen blended woven fabrics by water absorption. Wherase a high negative correlation exist between the k and air' permeability (Ap). There is a high positive correlation between the feeling of warmth/coldness and bulk density of pure linen and linen blended woven fabrics by water absorption. Wherase a high negative correlation exists between the feeling of warmth/coldness and porosity. There is a negative correlation between TIV and $q_{max}$ of pure linen fabrics and linen blended woven fabrics. The higher the rate of water absorbent, the lower the TIV. This means that TIV decreases by water absorption. As for the thermal property by rate of water absorbent $q_{max}$ and k increase by water absorption and reach max-value at 60% rate of water absorbent. The TIV decreases by water absorption and has +value at 0% rate of water absorbent, whereas it has -value with a feeling of coldness at 20%, 40%. and 60% rate of water absorbent.

  • PDF

High-Rate Biological Nitrogen Removal from Plating Wastewater using Submerged MBR Packed with Granular Sulfur (황 충진 MBR을 이용한 도금폐수의 고효율 생물학적 질소 제거)

  • Kim, Dae-young;Moon, Jin-young;Baek, Jin-uk;Hwang, Yong-woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.200-208
    • /
    • 2005
  • In this study, a new submerged membrane bioreactor process packed with granular sulfur (MBR-GS) was operated to identify the biological nitrogen removal behaviors with plating wastewater containing high-strength $NO_3{^-}$ concentration. The continuous denitrification was carried out at $20^{\circ}C$ with various nitrogen loading rates using synthetic wastewater, which composed of $NO_3{^-}$ and $HCO_3{^-}$, but also actual plating wastewater, which was collected from the effluent of the H metal plating company. As a result, high-rate denitrification in the range of $0.8kg\;NO_3{^-}-N/m^3\;day$ was accomplished at nitrogen loading rate of $0.9kg\;NO_3{^-}-N/m^3\;day$ using synthetic wastewater. Also, higher-rate denitrification with actual plating wastewater was achieved up to $0.91kg\;NO_3{^-}-N/m^3\;day$ at the loading rate of $1.11kg\;NO_3{^-}-N/m^3\;day$. Additionally, continuous filtration was possible during up to 30 days without chemical cleaning in the range of 20 cmHg of transmembrane pressure. On the basis of the proposed stoichiometry, ${SO_4}^{2-}$ production could be estimated efficiently, while observed alkalinity consumption was somewhat lower than theoretical value. Consequently, a new process, MBR-GS is capable of high-rate autotrophic denitrification by compulsive flux and expected to be utilized as an alternative of renovation techniques for nitrogen removal from not only plating wastewater but also municipal wastewater with low C/N ratio.

Experimental study on air-water countercurrent flow limitation in a vertical tube based on measurement of film thickness behavior

  • Wan, Jie;Sun, Wan;Deng, Jian;Pan, Liang-ming;Ding, Shu-hua
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.1821-1833
    • /
    • 2021
  • The gas-liquid counter-current flow limitation (CCFL) is closely related to efficient and safety operation of many equipment in industrial cycle. Air-water countercurrent flow experiments were performed in a tube with diameter of 25 mm to understand the triggering mechanism of CCFL. A parallel electrode probe was utilized to measure film thickness whereby the time domain and frequency domain characteristics of liquid film was obtained. The amplitude of the interface wave is small at low liquid flow rate while it becomes large at high liquid flow rate after being disturbed by the airflow. The spectral characteristic curve shows a peak-shaped distribution. The crest exists between 0 and 10 Hz and the amplitude decreases with the frequency increase. The analysis of visual observation and characteristic of film thickness indicate that two flooding mechanisms were identified at low and high liquid flow rate, respectively. At low liquid flow rate, the interfacial waves upward propagation is responsible for the formation of CCFL onset. While flooding at high liquid flow rate takes place as a direct consequence of the liquid bridging in tube due to the turbulent flow pattern. Moreover, it is believed that there is a transition region between the low and high liquid flow rate.

Sperm DNA fragmentation negatively influences the cumulative live birth rate in the intracytoplasmic sperm injection cycles of couples with unexplained infertility

  • Repalle, Deepthi;Saritha, Kallimakula Venkata Reddy;Bhandari, Shilpa
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.49 no.3
    • /
    • pp.185-195
    • /
    • 2022
  • Objective: This study aimed to determine the effect of sperm DNA fragmentation (SDF) on the cumulative live birth rate (CLBR) in intracytoplasmic sperm injection (ICSI) cycles in couples with unexplained infertility. Methods: We conducted a prospective study of 145 couples who underwent ICSI cycles for unexplained infertility. Based on the SDF rate, patients were categorized into a low SDF group (SDF ≤30%, n=97) and a high SDF group (SDF >30%, n=48). SDF was assessed using the acridine orange test on density gradient centrifugation prepared samples. The CLBR was calculated as the first live birth event per woman per egg collection over 2 years. Results: The high SDF group (SDF >30%) showed a significantly lower CLBR (p<0.05) and a significantly higher miscarriage rate (p<0.05) than the low SDF group (SDF ≤30%). No significant difference was observed in the implantation and cumulative pregnancy rates between the two SDF groups. The total number of embryo transfers was stratified further into fresh and frozen embryo transfers. In the fresh embryo transfers, there were significant differences in the implantation rates, clinical pregnancy rates, and live birth rates (p<0.05) between the low SDF and high SDF groups. However, in the frozen embryo transfers, there were no significant differences in clinical outcomes between the two groups. In the multivariable logistic regression analysis, SDF was a predictor of CLBR (p<0.05) when adjusted for possible confounding factors. Conclusion: High SDF was associated with a lower CLBR and a higher miscarriage rate in the ICSI cycles of couples with unexplained infertility.

Measures to revitalize fisheries high school (수산계 고등학교 활성화 방안)

  • LEE Yoo-Won;LEE Jong-Ho;PARK Tae-Gun;RYU Kyung-Jin
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.58 no.3
    • /
    • pp.262-271
    • /
    • 2022
  • The purpose of this study is to investigate the status of admission and employment in fisheries high schools (FHS) and to consider ways to revitalize FHS through substantialization. The recruitment rate of new students in FHS decreased from 97.4% in 2016 to 83.2% in 2020. The aging training ship that FHS needs to improve most urgently is being jointly used by FHS across the country, and the construction of a joint training ship managed by the Korea Institute of Maritime and Fisheries Technology is being promoted. The average employment rate for FHS by year was 40.2-59.4%, and the fisheries-related employment rate was low at 31.0-38.9%. On the other hand, the acquisition rate of certificate of competence was 37.5-52.0%, and the rate of employment on board of those who obtained the certificate of competence was 42.9-59.8%. In order to secure new students and improve the recruitment rate, we operate experiential classrooms that reflect the characteristics of training ships and departments and conduct public relations activities using sns, publicity video ucc, YouTube, etc. It will be necessary to expand opportunities for fisheries-related vocational experience through active career exploration and elective courses in the FHS credit system. Finally, it is judged that fisheries related government agencies, industries and local governments need to improve their awareness of FHS and plan to support fisheries manpower nurturing in order to attempt the vitalization of FHS.