• 제목/요약/키워드: high quality factor

검색결과 1,918건 처리시간 0.026초

High Throughput 프로세스에서 품질혁신의 성능평가를 위한 Z-Factor의 적용방안 (Implementation of Z-Factor Statistics for Performance Evaluation of Quality Innovation in the High Throughput Process)

  • 최성운
    • 대한안전경영과학회지
    • /
    • 제15권1호
    • /
    • pp.293-301
    • /
    • 2013
  • The purpose of this study is to introduce the limit of previously used six sigma quality process evaluation metrics, $Z_{st}$ and $P_{pk}$, and a solution to overcome this drawback by using a metric based on performance evaluation of Z-factor quality innovation. Case analysis on projects from national six sigma contest from 2011 to 2012 is performed and literature review on new drug development HTS (High Throughput Screening) is used to propose innovative performance evaluation metrics. This research shows that experimental study on six sigma evaluation metric, $Z_{st}$ and $P_{pk}$, have no significance difference between industrial type (Manufacturing, Semi-Public Institute, Public Institute) and CTQ type (Product Technology Type CTQ, Process Technology Type CTQ). Following discovery characterize this quality improvement as fixed target type project. As newly developed moving target type of quality innovation performance metric Z-Factor is used for evaluating experimental study, hypothetical analysis suggests that $Z_{st}$ and $P_{pk}$ share different relationship or even show reciprocal relationship. Constraints of the study are relatively small sample size of only 37 projects from past 2 years and conflict on having interview and communication with six sigma quality practitioner for qualitative experimental study. Both moving target type six sigma innovation project and fixed target type improvement project or quality circle enables efficient ways for a better understanding and quality practitioner use by applying quality innovation performance metric. Downside of fixed target type quality performance evaluation metric, $Z_{st}$ and $P_{pk}$, is presented through experimental study. In contrast, advantage of this study is that high throughput requiring product technology, process technology and quantum leap typed innovation effect is evaluated based on precision and accuracy and Z-Factor that enables relative comparison between enterprises is proposed and implemented.

Wafer-Level Packaged MEMS Resonators with a Highly Vacuum-Sensitive Quality Factor

  • Kang, Seok Jin;Moon, Young Soon;Son, Won Ho;Choi, Sie Young
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권5호
    • /
    • pp.632-639
    • /
    • 2014
  • Mechanical stress and the vacuum level are the two main factors dominating the quality factor of a resonator operated in the vacuum range 1 mTorr to 10 Torr. This means that if the quality factor of a resonator is very insensitive to the mechanical stress in the vacuum range, it is sensitive to mainly the ambient vacuum level. In this paper, a wafer-level packaged MEMS resonator with a highly vacuum-sensitive quality factor is presented. The proposed device is characterized by a package with out-of-plane symmetry and a suspending structure with only a single anchor. Out-of-plane symmetry helps prevent deformation of the packaged device due to thermal mismatch, and a single-clamped structure facilitates constraint-free displacement. As a result, the proposed device is very insensitive to mechanical stress and is sensitive to mainly the ambient vacuum level. The average quality factors of the devices packaged under pressures of 50, 100, and 200 mTorr were 4987, 3415, and 2127, respectively. The results demonstrated the high controllability of the quality factor by vacuum adjustment. The mechanical robustness of the quality factor was confirmed by comparing the quality factors before and after high-temperature storage. Furthermore, through more than 50 days of monitoring, the stability of the quality factor was also certified.

주성분 분석법을 이용한 낙동강 하구 해역의 수질 평가 (Evaluation of Water Quality using Principal Component Analysis in the Nakdong Rivev Estuary)

  • 신성교;박청길;송교욱
    • 한국환경과학회지
    • /
    • 제7권2호
    • /
    • pp.171-176
    • /
    • 1998
  • This study was conducted to evaluate water quality utilizing principal component analysis in the Nakdong River Estuary. From the results of analysis, water quality in the Nakdong River Estuary could be explained up to 65.3 Percente by three factors which were Included In river loadlnwastes from the Nakdong River and rainfalls : 39.1%1, sediment resuspension(13.7BS) and metabolism(12.5%). In the eastern part of estuary In flowing the Nakdong River, river loading factor score(factor 1 Pas higher than that In western part. Sediment resuspension factor score(factor 2) was high in shallow water, while metabolism factor score(factor 3) was high in deeper water. For seasonal variations of factors score, factor 1 was h19h- 1y related to rainfall season.

  • PDF

고강도 콘크리트의 취도계수에 관한 실험적 연구 (An experimental study on the fragility factor of high strength concrete)

  • 김희두;양성환
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.148-149
    • /
    • 2014
  • In modern society, population overcrowding and concentration of facilities are happened because of the concentration on to city. So this phenomenon demands improvement of material's performance, technical development of structure analysis and design and improvement of constructing ability .High strength concrete has some merits. High strengthening makes the cross section reduced, and that cause decrease of structure weight. And using high durable and superplasticizer promote liquidity, thus high quality concrete can be produced. Because of these advantages, this study is for showing validity of using it by compression/tensile strength experiment. As this experiment's result, when concrete become stronger, interface intensity coefficient between cement and aggregate is different and they don't adhere to each other. So there is brittle failure. Fragility factor also steadily increase with strong concrete, it tells high strength concrete has problem. Therefore the sources used in high strength concrete like cement and aggregate must have great quality. So the source's performance must be supervised well because their quality decides performance criteria.

  • PDF

외식기업의 경쟁력 강화 요인에 관한 연구 - 외식기업 내부요인을 중심으로 - (Research about Competitive Power High Position of Food-Service Industry - Laying Stress on Eating Out Company Interior Factor -)

  • 유택용;박면애
    • 한국조리학회지
    • /
    • 제10권3호
    • /
    • pp.83-96
    • /
    • 2004
  • According to construction of global administration environment, all over the world was ended up in infinite competition period. Because eating out company also competes with another company, it must enjoy competitive power high position to secure high position continuously, classified by formation constituent's individuation and two aspects of organic special quality by the factor. Individuation classified by formation constituent's business ability, personal relations, age factors of Information Technology, and organic special quality classifies by factor of formation culture and result that analyze eating out company's business condition competitive power reinforcement effect factor is same as following. First, was construed by company culture, personal relations, business ability period of ten days with family Restaurant, and Information Technology showed that do not influence. Competitive power reinforcement effect factor with special restaurant was construed by company culture, personal relations, business ability period of ten days, and fast food company culture and Information Technology factor with hotel restaurant company culture by competitive power reinforcement effect factor construe.

  • PDF

솔레노이드 형태의 RF 칩 인덕터에 대한 연구 (A Study for Solenoid-Type RF Chip Inductors)

  • 김재욱;윤의중;정여창;홍철호
    • 한국전기전자재료학회논문지
    • /
    • 제13권10호
    • /
    • pp.840-846
    • /
    • 2000
  • In this work, small-size, high-performance solenoid-type RF chip inductors utilizing a low-loss Al$_2$O$_3$core material were investigated. The size of the chip inductors fabricated in this work were 15$\times$10$\times$0.7㎣, 2.1$\times$1.5$\times$10㎣, and 2.4$\times$2.0$\times$1.4㎣ and copper (Cu) wire with 40 ㎛ diameter was used as the coils. High frequency characteristics of the inductance, quality factor, and impedance of developed inductors were measured suing an RF Impedance/Material Analyzer (HP4291B with HP16193A test fixture). It was observed that the developed inductors with the number of turns of 7 have the inductance of 33 to 100nH and exhibit the self-resonant frequency (SRF) of .26 to 1.1 GHz. The SRF of inductors decreases with increasing the inductance and the inductors have the quality factor of 60 to 80 in the frequency range of 300 MHz to 1.1 GHz. In this study, small-size solenoid-type RF chip inductors with high inductance and high quality factor were fabricated successfully. It is suggested that the thin film-type inductor is necessary to fabricate the smaller size inductors at the expence of inductance and quality factor values.

  • PDF

다변량 해석기법을 이용한 인천연안해역의 수질평가 (The Evaluation of Water Quality in Coastal Sea of Incheon Using a Multivariate Analysis)

  • 김종구
    • 한국환경과학회지
    • /
    • 제15권11호
    • /
    • pp.1017-1025
    • /
    • 2006
  • This study was conducted to evaluate characteristic of water duality in coastal sea of Incheon using a multivariate analysis. The analysis data in coastal sea of Incheon was aquired by the NFRDI data which was surveyed from March 1997 to November 2003. Eleven water quality parameters were determined on each survey The results were summarized as follow : Water quality in Incheon coastal sea could be explained up to 64.62% by three factors which were included in loading of fresh water and nutrients by the land(36.98%), seasonal variation(16.19%), and internal metabolism (11.24%). The results of time series analysis by factor score, in case of factor 1, station 1 influenced by Han river was shown to high factor score and station 3 located by outer sea was shown to low factor score. In case of factor 2, station 1 was appeared to high variation and station 3 was appeared to low variation. The result of cluster analysis by station was classified into three group that has different water quality characteristics. Especially, station 1 which affected by Han river and station 4 which affected by sewage treatment plant was appeared to considerable water quality characteristics against other station. In yearly cluster analysis, three group was classified and water quality in 2003 years due to high precipitation was different to another year. It could be suggested from these results that it is important to control discharge of fresh water by Han rivet and sewage treatment plant for water quality management of coastal sea of Incheon.

Factor Analyses for Water Quality Indicators of Streams, Ground Water, and Reservoir in Agricultural Small Catchments of the Han River Basin

  • Park, C-S;Joo, J-H;Jung, Y-S;Yang, J-E
    • 한국환경농학회지
    • /
    • 제19권5호
    • /
    • pp.382-393
    • /
    • 2000
  • The principal indicators contributing to water qualities was screened by factor analyses, based on the monitored chemical parameters of water quality for various water resources from 1995 to 1999 in the small agricultural catchments of the Han River Basin. Water samples of streams, groundwaters, and reservoirs were taken four times a year from upper (Daegwanryong), middle (Dunnae and Chunchon) and lower (Guri) reaches of Han River Basin. In these areas, the respective type of farming practiced was alpine agriculture and livestocks raising, typical upland and paddy cultivation, and intensive cropping in the plastic film house. Water quality was monitored for twenty-one water quality parameters, including pH, EC, SS, T-N, T-P, COD, cations, anions, and heavy metals. pH, EC and COD of the stream waters were suitable for the Korea irrigation water quality guidelines. However, T-N and T-P concentrations of water samples in four catchments far exceeded the irrigation water guideline. Concentrations of canons and heavy metals in Wangsuk stream in Guri area were higher than those in streams in other areas. Factor analysis revealed that significant correlation was observed for 81 pairs out of 231 water quality indicators of stream water among the $21\;{\times}\;21$ cross correlation matrix of stream water quality indicators. The first factor accounted for 27.01% of the total variation in stream water quality indicators, and high positive factor loadings were shown on EC, K, Na, $NH_4\;^+-N$, $PO_4\;^{3-}$, $SO_4\;^{2-}$, and COD. Fifty-three water quality indicator pairs were significant out of 190 ground water quality parameters. The first factor accounted for 28.54% of the total variation in ground water quality indicators, and high loadings were revealed on EC, Ca, Mg, K, Na, $NH_4\;^+-N$, and $SO_4$. Twenty-nine pairs of reservoir water quality indicators were significant out of 66 pairs. The first factor accounted for 37.06% of the total variation in reservoir water quality indicators, and high loadings were shown on EC, Mg, K, Na, SS, T-P, Cl, and COD. These results demonstrate that EC was the first factor contributing to water quality.

  • PDF

Quality factor 와 공진시 변위 측정을 이용한 진동형 자이로스코프의 특성 평가에 관한 연구 (A Study on the Measurement Methodology of Characteristics of the Vibratory Micro Gyroscope Using the Quality factor and the Resonant Displacement)

  • 전승훈;이준영;정형균;장현기;김용권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.2090-2092
    • /
    • 2004
  • In this paper, the new measurement methodology of characteristics of the vibratory micro gyroscope using Quality factor and the resonant displacement was proposed. Because the Quality factor has a large error under the high Quality factor condition, it is difficult to analyze the characteristics of the vacuum packaged vibratory micro gyroscopes with the Quality factor. We analyzed mechanical characteristics of gyroscope with the value of Quality factor. We described measurement errors of mechanical characteristics of micro gyroscopes. The measured value of Quality factor is 47532 and error range of Quality factor is from -29.8 % to 73.9 %. The value of resonant displacement is 3.4${\mu}m$ and the measurement error is 2.9 %. From the result of Quality factor degradation and resonant displacement degradation, 1698 days and 1503 days were estimated as Time To Failure (TTF), respectively. The range of estimation error of Quality factor degradation and resonant displacement degradation is calculated from 1246 days to 1832 days and from 1456 days to 1537 days, respectively. We can analyze the characteristics of the vibratory gyroscope using the quality factor when the Quality factor is smaller than 10,000. Also we can analyze that using the resonant displacement when the Quality factor is larger than 10,000.

  • PDF

테라헤르츠 비대칭 분리고리공진기 메타물질의 높은 품질인자를 위한 공진 특성에 관한 연구 (A Study on Resonance Properties of a Terahertz Asymmetric Split-Loop Resonator Type Metamaterial for High Quality Factor)

  • 박대준;류한철
    • 한국산학기술학회논문지
    • /
    • 제17권11호
    • /
    • pp.663-669
    • /
    • 2016
  • 본 논문에서는 높은 감도의 테라헤르츠 센서로 응용이 가능한 고품질 비대칭 분리고리공진기(ASLR: Asymmetric Split-Loop Resonator) 메타물질의 구조적인 비대칭 정도에 따른 ASLR의 공진특성 변화를 전자기 시뮬레이션을 통하여 분석하였다. 특히, ASLR의 구조적 비대칭성은 높은 품질인자를 갖는 파노공진을 발생시키므로 ASLR의 비대칭성 정도에 따라서 ASLR 고유공진과 파노공진의 공진주파수 변화와 투과계수 및 품질인자의 변화를 분석하였다. 또한, ASLR의 구조적 비대칭성에 따른 ASLR의 공진 특성 변화의 원인을 분석하기 위해 표면전류밀도를 계산하여 ASLR 공진의 공진주파수, 투과계수, 그리고 품질인자가 변화하는 이유를 분석하였다. 이를 통하여 ASLR 고유공진의 표면전류밀도는 이중 극자를 형성하여 높은 방사 손실을 가지게 되므로 품질인자가 낮아지게 되고, 파노공진의 표면전류밀도는 닫힌 모드 또는 사중 극자를 형성하여 이중 극자에 비하여 낮은 방사 손실을 가지므로 파노공진 상태의 ASLR이 높은 품질인자를 가지게 됨을 확인하였다. 이러한 ASLR의 파노공진 특성 분석 결과를 바탕으로 메타물질의 비대칭성을 조절하면 높은 품질인자를 가지는 테라헤르츠 고성능 필터 또는 고감도 센서 개발이 가능하다. 이러한 고감도 고성능 테라헤르츠 소자 개발은 테라헤르츠 메타물질의 실질적인 산업 응용을 유도할 것으로 기대한다.