• Title/Summary/Keyword: high pressure discharge

Search Result 512, Processing Time 0.033 seconds

Study of the Characteristic and Optimization of Induction Lamp according to Gas Pressure and Amalgam Type (고출력 무전극램프의 가스압 및 아말감종류에 따른 특성분석 및 최적화에 관한 연구)

  • Chung, Young-Il;Jung, Dae-Chul;Kim, Yong-Kab;Park, Dae-Hee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.1
    • /
    • pp.23-30
    • /
    • 2017
  • Currently, road lightings are installed with less than 400W of existing metal halide lamps. These road lightings are being replaced by energy-saving lightings. Induction lamps are expected to be more actively replaced with targets for tunnel lighting and high ceiling lighting. Therefore, it is necessary to develop high efficiency, high power induction lamps system. In this study, the gas type & pressure, amalgam type were designed for the high power of the induction lamps. And induction lamp system was optimized through electrical, optical characteristics analysis. It is optimized to the gas pressure 300~350 [mmHg] for the discharge tube of high power induction lamp and ferrite core. The driving circuit matching was completed with a induction lamp using indium amalgam. The rated power consumption of the induction lamp was optimized with 250 W (rated ${\pm}10%$)

Dielectric Thin Film Using Atmospheric Pressure Plasma Polymerization

  • Choi, Sung-Lan;Kim, Hong-Doo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1444-1446
    • /
    • 2009
  • The atmospheric pressure plasma polymerization of acrylate monomers was carried out to have dielectrics with easy preparation and high performance. The effects of discharge power, monomer concentration and deposition time on film properties were investigated using various characterization tools. With proper conditions, smooth dielectric layer of 100nm thickness was obtained. Dielectric property as organic dielectric layer has been studied for future applications in organic thin film transistors(OTFT).

  • PDF

Evaluation on Water Vapor Pressure of Amorphous Steel Fiber reinforced High Strength Concrete (비정질 강섬유 혼입 고강도콘크리트의 수증기압력 평가)

  • Kim, Duck-Woo;Kim, Gyu-Yong;Hwang, Eui-Chul;Son, Min-Jae;Baek, Jae-Wook;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.44-45
    • /
    • 2018
  • In this study, water vapor pressure of high strength concrete reinforced with amorphous steel fiber(AF) was evaluated. Experimental results show that spalling occurs when the incorporation rate of amorphous steel fiber is 0.5 vol.% or more. This is because the ratio of AF increased per unit area influenced the formation of the water vapor pressure discharge passage by the polypropylene fiber(PPF) melting. Therefore, it is necessary to find the proper mixing ratio of AF and PPF to prevent spalling.

  • PDF

A Study for Numerical Analysis of Flow Variation on Low Pressure Fuel Pump Fluid using Excavator Engine (굴삭기 엔진용 저압연료펌프 유체의 유동변화에 대한 수치해석적 연구)

  • Lee, IL Kwon;Kim, Seung Chul
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.47-53
    • /
    • 2015
  • This paper is to study applying for numerical analysis method for flow field, velocity and pressure of fuel on the low pressure pump using excavator. The pressure distribution of fuel pump certified the linear variation according to rotation angle of rotor. Especially, it knew the fact that the pressure in rotation angle $40^{\circ}$ appeared high outlet and low inlet of fuel pump. Also, this range angle can seek the fact that the leakage flow and velocity are the most increasing. And the more rotor rotation of fuel pump, the more mean outlet flow rate increased in linear. Whenever the gap size decrease with rotor and housing, the discharge flow rate could seek the approaching 0.0712kg/s that consider with theory discharge flow rate calculated from displacement between rotor gear and idle gear.

Performance analysis of hubless rim-driven thruster based on the number of blades: a CFD approach (날개수에 따른 허브리스 림 추진기의 성능 분석 : CFD를 이용한 접근)

  • Hyoung-Ho KIM;Chang-Je LEE
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.60 no.1
    • /
    • pp.80-86
    • /
    • 2024
  • We analyzed the performance of hubless rim propellers based on the number of blades, maintaining a fixed pitch ratio and expanded area ratio, using computational fluid dynamics (CFD). Thrust coefficient, torque coefficient and efficiency according to the number of blades were analyzed. In addition, the pressure distribution on the discharge and suction sides of the blade was analyzed. As the advance ratio increases, the thrust coefficient decreases. The highest thrust was shown when the advance ratio was lowest. For the three, four, five and six-blades, the torque coefficient tended to decrease as the advance ratio increased. In the case of seven and eight-blades, the torque coefficient tended to increase as the advance ratio increased. The maximum efficiency was found when the advance ratio was 0.8. When the three-blade, it showed high efficiency at all advance ratios. A high pressure distribution was observed at the leading edge of the discharge blade, and a low pressure distribution was observed at the trailing edge. Applying a hubless rim-driven thruster with the three-blade can generate higher thrust and increase work efficiency.

Position Control of a Pneumatic Cylinder Actuator using PLC and Proximity Sensors (공압 실린더 액츄에이터 위치제어)

  • Kwon, Soon-Hong;Choi, Won-Sik;Chung, Sung-Won;Park, Jong-Min;Kwon, Soon-Goo;So, Jung-Duk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.6
    • /
    • pp.50-55
    • /
    • 2011
  • The fluid power products are widely used in current industrial area such as automation of products and equipment assembly, high-tech machine tool, aircraft, train, and etc. As the development of industry is in progress, the development of the fluid power products is demanding and it is required in every industrial area. This research proposed a pneumatic system to evaluate displacement accuracy of the pneumatic actuator without external load and to analyze capability of integration of the valve system. The pneumatic system consisted of a combination of pneumatic actuator, four two-port valves, two three-port valves, two pressure valve, a check valve, two proximity sensors, and a program logic controller (PLC). The position controller is based on the PLC connected with the proximity sensors. The maximum air pressure applied for tests was $49.05N/cm^2$ and the displacement accuracy of a stroke was measured using a dial gauge. The supply- and discharge-side of air pressure and the length of the stroke of the pneumatic cylinder were varied The test of the position control of the pneumatic cylinder was carried out 50 times at each supply- and discharge-side air pressure of 24.53/34.34, 29.43/39.24, 34.34/44.15, and $39.24/49.05N/cm^2$ and replicated three times. The accuracy of the displacement of the pneumatic cylinder stroke increased as the supply- and discharge-side of air pressure increased with the stroke length of 133mm. Also the displacement accuracy increased as the stroke length increased with the fixed supply- and discharge-side of air pressure of the pneumatic cylinder as 34.34 and $44.15N/cm^2$, respectively. The most accurate displacement of the pneumatic cylinder was obtained at the supplyand discharge-side of air pressure of 39.24 and $49.05N/cm^2$, respectively, and strokes of 170 and 190mm.

Effects of Base Vacuum Level on Discharge Characteristics in Vacuum In-Line Sealing Process for High Efficient PDP

  • Kwon, Sang-Jik;Jang, Chan-Kyu
    • Journal of Information Display
    • /
    • v.5 no.4
    • /
    • pp.7-11
    • /
    • 2004
  • Effects of base vacuum level on the electrical and optical characteristics of the plasma display panel (PDP) were investigated. The relationship between efficiency and base vacuum level before filling discharge gas was analyzed. For the base vacuum level of $1{\times}10^{-4}$ torr, firing voltage of a 2-inch diagonal PDP panel was 232 V at the discharge gas pressure of 400 torr and luminous efficiency was 1.5 lm/W at 180V sustaining pulse. On the other hand for $1{\times}10^{-6}$torr, the firing voltage was reduced to 215 V and luminous efficiency was improved considerably to 2.5 lm/W. We successfully demonstrated the smooth operation of tip-less PDP fabricated using vacuum in-line sealing method.

Self Reversal Effect of the High-pressured Diatomic Sulfur in the Electrodeless Sulfur Discharge Lamp (무전극 황방전등에서 고압 이원자 황($S_2$)의 자체 역전 효과)

  • Chu, Jang-Hee;Goo, Sun-Geun;Park, Ki-Jun;Yi, Young-Woo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.11
    • /
    • pp.609-615
    • /
    • 2000
  • A prototype electrodeless sulfur lamp was developed and investigated the spectroscopic characteristics. The emission spectra of $S_2$ in the microwave-discharged eletrodeless sulfur lamp (ESL) were studied at various input power. The emission spectra of the ESL shift to longer wavelength with increasing of the input power. We have shown that this is due to the self reversal effect in the high pressure gas discharge. We also show that the self reversal effect increases as the rotation of the discharged bulb. The spectral distribution of the ESL shifts about 45 nm toward visible region from UV region due to the rotation of the lamp bulb.

  • PDF

Inductively Coupled Plasma discharge characteristic of Ne, Ar, Kr mixed gas (유도결합형 플라즈마에서의 Ne, Ar, Kr 혼합가스 방전특성)

  • Her, In-Sung;Choi, Yong-Sung;Lee, Chong-Chan;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.306-309
    • /
    • 2004
  • Recently, the environmental problem has received considerable attention. so, many lamps have been developing for environmental requirement and energy efficiency. also, at glow discharge lamp researchers try to reduce energy spending that is power saving lamp. this kind requirement agree with strong points of electrodeless fluorescent lamp has received to now lighting sauce. At low pressure as mTorr I.C.P make high density plasma easily, is good to maintain discharge, has high ionization and does not have failing lighting and losing ability of electron radiation by oxidation and volatilization of electrodes, because this tape does not have electrodes. This point of I.C.P can use at electrodeless fluorescent lamp in this study ICP display elements and Ar, Ne, Kr are researched for optical characteristic. each gas is looked into optical characteristic, also mixed gases is experiment for optical characteristic.

  • PDF

A Study on Frequency-Modulated Methods for Reducing Acoustic Resonance in HID Lamp (고압방전램프의 음향공명감소를 위한 주파수변조에 관한 연구)

  • Kim, Gi-Jung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.12
    • /
    • pp.622-626
    • /
    • 2001
  • HID(high intensity discharge)lamps are high pressure mercury lamp, high pressure sodium lamp and metalhalide lamp. metalhalide lamp among these lamps has considered to be one of the most effective artificial light sources and this lamp has good efficiency, good color rendition and good focusing capability, But the shortcorning of metalhalide lamp is known as acoustic resonance phenomena in the discharge tube when lighted by electronic ballast and then acoustic resonance cause various problems such as the arc instability, light output fluctuations. In this paper, to reduce the acoustic resonence phenomena, the electronic ballast was designed by three methods for high frequency operation wish frequency-modulated sinusodial waves in acoustic resonance frequency band. These frequency-modulated methods are resonance frequency and resonance frequency, resonance frequency and non-resonance frequency non-resonance frequency and non-resonance frequency Experiment results could't show the Presence of acoustic resonance visually and it proved that the resonance-generating conditions can be avoided by continuously changing the two operating frequencies in acoustic resonance band (20.59kHz∼94.2kHz).

  • PDF