• 제목/요약/키워드: high pressure air control system

검색결과 135건 처리시간 0.026초

초고층 건축물의 수직 구획화에 따른 급기가압제연시스템 성능평가에 관한 연구 (A Study on the Smoke Control Performance Evaluation of High-rise Buildings under Smokeproof Enclosure Design Scenarios)

  • 배상환;류형규;이병석
    • 설비공학논문집
    • /
    • 제26권7호
    • /
    • pp.343-350
    • /
    • 2014
  • Regardless of the building design scenarios, evaluation of high-rise buildings required to have smoke-proof enclosures that are provided with a smoke management system. The goal of the smoke management system design is to make sure the pressure differentials at every story within the building fall within the allowable pressure range. If the minimum design pressure is not met, smoke may enter the stair. If the provided pressure is too great, it becomes difficult for occupants to open the doors, while attempting to egress. Ensuring that the pressure differential between the vestibule and the floor is within the prescribed range becomes challenging, due to natural effects on the building, such as the stack effect. In this research, smokeproof enclosure design scenarios were evaluated; and as a result, separation levels for compartmentation were deduced, in the balancing of pressurized-vestibule smoke control systems.

연료전지 자동차용 전자 제어식 $CO_2$ 냉방 시스템의 성능 특성에 관한 연구 (Studies on the Performance Characteristics of an Electronically Controlled $CO_2$ Air Conditioning System for Fuel Cell Electric Vehicles)

  • 김성철;이동혁;이호성;원종필;이대웅;이원석
    • 한국자동차공학회논문집
    • /
    • 제16권2호
    • /
    • pp.150-157
    • /
    • 2008
  • The main objective of this paper is to investigate the performance characteristics of a $CO_2$ air conditioning system for fuel cell electric vehicles (FCEV). The present air conditioning system for FCEV uses the electrically driven compressor and electrically controlled expansion valve for $CO_2$ as a working fluid. The experimental work has been done with various operating conditions, which are quite matching the actual vehicle's driving conditions such as different compressor speed and high pressure to identify the characteristics of the system. Experimental results show that the cooling capacity and coefficient of performance (COP) were up to 6.3kW and 2.5, respectively. This paper also deals with the development of optimum high pressure control algorithm for the transcritical $CO_2$ cycle to achieve the maximum COP.

초고층공동주택 국소배기용 입상덕트의 배기성능평가에 관한 연구 (Study on the Performance Evaluation of the Exhaust Stack used in High Riser Public House)

  • 권용일;이태규;안정헌
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.889-894
    • /
    • 2008
  • Exhaust system used in toilet and cooking place of high riser public house is roof fan of two basic types : natural roof ventilator and natural/forced roof ventilator. Natural/forced roof ventilator has a motor in the rotary shaft. There are many high riser public house in Korea. These buildings were not viewed as being major contributors to exhaust pollutants producted in indoor. It was because many engineers thought that exhaust in high riser building depend on stack effect. This study investigates on stack pressure determined by exterior pressure and the difference pressure control in exhaust stack used in high riser public house. This paper focuses mainly on the effect of the time interval for power supply of motor installed in roof fan with function of natural wind velocity and of exhaust air volume of toilet. It is observed there are higher exhaust efficiency than the existing natural roof ventilator.

  • PDF

샌드위치 가압을 이용하는 연기제어 시스템의 현장실험 사례 연구 (Case Study of a Field Test for a Smoke Control System Using Sandwich Pressurization)

  • 김정엽;안찬솔
    • 한국화재소방학회논문지
    • /
    • 제30권5호
    • /
    • pp.87-92
    • /
    • 2016
  • 국내에서는 고층 및 복합 건축물이 다수 시공되고 있는 상황에서 화재시 실효성 있는 연기대응 기술의 확립이 요구되고 있으며, 고층 건축물에서 제연설비에 대한 대안으로서 샌드위치 가압을 이용하는 연기제어 시스템의 적용이 확대되고 있다. 샌드위치 가압을 이용하는 연기제어 시스템은 연기확산 방지와 원할한 피난환경 제공을 위해서 적정 층간차압과 이를 위한 급배기 풍량의 설계에 관한 자료가 확보되어야 한다. 본 논문에서는 이러한 연구의 일환으로서 샌드위치 가압을 이용하는 연기제어 시스템이 설치된 실제 건축물에서 수행한 현장실험의 과정과 결과를 제시하였다. 실험에서 화재층의 배기풍량과 상하부층의 급기풍량으로 시간당 6회의 환기횟수를 적용하였으며, 시스템 가동으로 화재층인 12층과 그 상부층인 13층 사이에 약 260 Pa의 압력차가 형성되었다. 이러한 압력차 형성은 피난 및 방화구획에 상당한 영향을 미치므로 이에 대한 추가적인 연구가 필요하다.

랩온어칩 내부 미세유동제어를 위한 새로운 유동제어기법 (A New Flow Control Technique for Handling Infinitesimal Flows Inside a Lab-On-a-Chip)

  • 한수동;김국배;이상준
    • 대한기계학회논문집B
    • /
    • 제30권2호
    • /
    • pp.110-116
    • /
    • 2006
  • A syringe pump or a device using high electric voltage has been used for controlling flows inside a LOC (lab-on-a-chip). Compared to LOC, however, these microfluidic devices are large and heavy that they are burdensome for a portable ${\mu}-TAS$ (micro total analysis system). In this study, a new flow control technique employing pressure regulators and pressure chambers was developed. This technique utilizes compressed air to control the micro-scale flow inside a LOC, instead of a mechanical actuator or an electric power supply. The pressure regulator controls the output air pressure by adjusting the variable resistor attached. We checked the feasibility of this system by measuring the flow rate inside a capillary tube of $100{\mu}m$ diameter in the Re numbers ranged from 0.5 to 50. In addition, the performance of this flow control system was compared with that of a conventional syringe pump. The developed flow control system was found to show superior performance, compared with the syringe pump. It maintains automatically the: air pressure inside a pressure chamber whether the flow inside the capillary tube is on or off. Since the flow rate is nearly proportional to the resistance, we can control flow in multiple microchannels precisely. However, the syringe pump shows large variation of flow rate when the fluid flow is blocked in the microchannel.

CO2냉매용 제어밸브의 응답 특성 (Transient Response Analysis of a Control Valve for CO2 Refrigerant)

  • 김보현;장지성
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권4호
    • /
    • pp.11-16
    • /
    • 2018
  • Pilot operated control valve for $CO_2$ refrigerant is a valve that can perform various functions according to the user's intention by replacing pilot units, widely used for flow rate, pressure, and temperature control of refrigeration and air conditioning systems. In addition, $CO_2$ refrigerant, that requires high pressure and low critical temperature, can be installed and used in all positions of the refrigeration system, regardless of high or low pressure. In this paper, response characteristics are modeled and analyzed based on behavior of the main piston of the pilot-operated control valve. Although various factors influence operation of the main piston, this paper analyzes the effect of equilibrium pressure depending on valve installation position and application, and inlet and outlet orifice size of the load pressure feedback chamber to determine feedback characteristics of the main piston. As a result, it was possible to quantitatively analyze the effect of change in equilibrium and load pressure feedback chamber flow path size on the change in main piston dynamic and static characteristics.

연면방전의 플라즈마 화학처리에 의한 유해가스제어 성능에 관한 연구 (A Study on the Control Performance for Hazardous Gases by Surface Discharge induced Plasma Chemical Process)

  • 이주상;김신도;김광영;김종호
    • 한국대기환경학회지
    • /
    • 제11권2호
    • /
    • pp.185-190
    • /
    • 1995
  • Recently, because of the worse of the air pollution, the excessive airtught of building and the inferiority of air conditioning system, the development of high efficiency air purification technology was enlarged to the environmental improvement of an indoor or a harmful working condition. The air purification technology has used chemical filters or charcoal filters or charcoal to remove hazardouse gaseous pollutants (SO$_{x}$, NO$_{x}$, NH$_{3}$, etc.) by air pollutant control technology, but they have many problems of high pressure loss, short life, wide space possession, and treatment of secondary wastes. For these reason, the object of reasearch shall be hazardous gaseous pollutants removal by the surface discharge induced plasma chemical process that is A.C. discharge of multistreams applied A.C. voltage and frequency between plane induced eletrode and line discharge eletrode of tungsten, platinum or titanium with a high purified alumina sheet having a film-like plane. As a result, the control performance for hazardous gaseous pollutants showed very high efficiency in the normal temperature and pressure. Also, after comtact oxidation decomposition of harmful gaseous pollutants, the remainded ozone concentration was found much lower than that of ACGIH or air pollution criteria in Korea.rea.

  • PDF

초고층 건물의 제연영향요소에 따른 수직피난공간 압력분포 시뮬레이션 (A Study on the Pressure Difference of Smoke Control Influence Factor in the Super High-rise Building)

  • 최승혁;이동윤;전현도;박진철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.130-135
    • /
    • 2009
  • These days, the super high-rise buildings construction plans are increased in Korea. But the stack effect in the super high-rise building interrupts the smoke control system's operation because of pressure difference, so it is more dangerous than the general building when firing. Therefore it needs to study about the pressure difference in the super high-rise buildings. We research the smoke control influence factor in the super high-rise building. Reflecting the influence factor, the simulation is practiced the case by case.

  • PDF

종합공동육묘장의 설비 자동화에 관한 연구 -파종시스템- (Study on Automation of Integrated Seedling Production System - Planting Device-)

  • 최창현;노광모;이규창;김재민
    • Journal of Biosystems Engineering
    • /
    • 제21권2호
    • /
    • pp.123-133
    • /
    • 1996
  • An automatic drum seeder was developed to improve the seeding operation. It consisted of a conveyor to transfer seedling trays, a seed-hopper to supply seeds, a drum to drop seeds on the tray, and an air blower to remove extra seeds. A photo sensor was used to detect the transfer of seedling trays, and its signal was fed into microcomputer which operated a stepping motor driving the drum. The seeds were adhered to the surface of drum by vacuum pressure, and were dropped into tray cells by compressed air. An air connection unit was devised to alternate between vacuum pressure and compressed air. A control program for the system, written in C language, could operate the drum at the given number of revolutions and revolutions per minute. The results showed that the air connection unit could operate well and the seeds were dropped satisfactorily into tray cells. In case of cabbage and perilla seeds, which are regular and spherical shape, the missing rate was low and the single seeding rate was more than 97%. Low missing rate and high multiple seeding rate were observed in lettuce seeds which have narrow ends with tight weight. The missing rate of pepper seed was very high because of heavy weight and irregular shape. To improve the performance of the seeder, adjustment of vacuum pressure based upon shape and weight of the seeds, careful selection of the material of drum, maintenance of consistent air blower pressure, and replacement of stepping motor to DC motor are recommended.

  • PDF

터보냉동기를 위한 실용적 모델링과 PI 제어기 설계 (Practical Modeling and PI Controller Design for Centrifugal Water Chillers)

  • 정석권;한성준;정영미
    • 설비공학논문집
    • /
    • 제27권4호
    • /
    • pp.187-194
    • /
    • 2015
  • This paper describes the PI controller design based on a practical transfer function model for centrifugal water chillers. The rotational speed of a compressor and the opening angle of an electronic expansion valve were simultaneously regulated as manipulated variables to maintain temperature reference and to ensure high efficiency of the chiller. The COP according to the change in each variable was investigated by performing some static experiments, and it was reflected in the PI controller design to accomplish the high efficiency control. Especially, the practical transfer function model of the chiller was built based on the dynamic experimental data considering the strong inherent non-linearity and complexity of the chiller system. The validity of the designed PI controller was proven by some experimental results using the test facility and the results were also compared to the conventional evaporating pressure control results.