• Title/Summary/Keyword: high performance steel

Search Result 1,517, Processing Time 0.029 seconds

Performance of carbon nanotube-coated steel slag for high concentrations of phosphorus from pig manure

  • Kang, Kyeong Hwan;Kim, Junghyeon;Jeon, Hyeonjin;Kim, Kyoungwoo;Byun, Imgyu
    • Membrane and Water Treatment
    • /
    • v.11 no.1
    • /
    • pp.59-68
    • /
    • 2020
  • The study objective was to evaluate the enhanced removal of high concentrations of phosphorus from synthetic wastewater (solely phosphorus-containing) and real wastewater (pig manure) by using carbon nanotube (CNT)-coated steel slag. Generally, phosphorus removal by steel slag is attributed to Ca2+ eluted from the slag. However, in this study, CNT was used to control the excess release of Ca2+ from steel slag and increase the phosphorus removal. The phosphorus removal rate by the uncoated steel slag was lower than that of the CNT-coated steel slag, even though the Ca2+ concentrations were higher in the solution containing the uncoated steel slag. Therefore, the phosphorus removal could be attributed to both precipitation with Ca2+ eluted from steel slag in aqueous solution and adsorption onto the surface of the CNT-coated steel slag. Furthermore, the protons released from the CNT surface by exchanging with divalent cations acted to reduce the pH increase of the solution, which is attributed to the OH- eluted from the steel slag. The adsorption isotherm and kinetics of the CNT-coated steel slags followed the Freundlich isotherm and pseudo-second-order model, respectively. The maximum adsorption capacity of the uncoated and CNT-coated steel slags was 6.127 and 9.268 mg P g-1 slag, respectively. In addition, phosphorus from pig manure was more effectively removed by the CNT-coated steel slag than by the uncoated slag. Over 24 hours, the PO4-P removal in pig manure was 12.3% higher by the CNT-coated slag. This CNT-coated steel slag can be used to remove both phosphorus and metals and has potential applications in high phosphorus-containing wastewater like pig manure.

A Behavior of Fatigue Crack Growth of Nonmagnetic Steel with Large Grain Size (조대조직을 갖는 비자성강의 피로균열진전거동)

  • Lee, Jong-Hyung;Choi, Seong-Dae;Cheong, Seon-Hwan;Kwon, Hyun-Kyu;Yang, Seong-Hyeon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.3 no.4
    • /
    • pp.88-94
    • /
    • 2004
  • High manganese steel was maintained stability of Non-Magnetics performance. Fatigue tests were carried out under constant stress amplitude, using a non-magnetic high manganese steel. The fatigue crack growth mechanism of the high manganese steel was clarified from results such as observation of crack growth path and fracture surface. The result of getting this study was shown as following: 1) Remarkably ${\Delta}Kth$ of the high manganese steel is big with about 3 times of the general steel product. 2) In the low ${\Delta}K$ value region, da/dN is dependent on Kmax, and in the high ${\Delta}K$ value region, it is dependent on ${\Delta}Keff$. The reason of this behavior is crack closure due to fracture surface roughness and fretting oxide. 3) It seems to ease the stress concentration of crack tip crack growth behavior in the ${\Delta}Kth$ vicinity by the generation of the secondary crack.

  • PDF

Seismic Performance Assessment of Roof-Level Joints with Steel Fiber-Reinforced High-Strength Concrete (강섬유보강 고강도콘크리트를 적용한 최상층 접합부의 내진성능 평가)

  • Kim, Sang-Hee;Kwon, Byung-Un;Kang, Thomas H.-K.
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.2
    • /
    • pp.235-244
    • /
    • 2016
  • This study was conducted to verify seismic performance of special moment frame's joints at roof-level with high-strength concrete and SD600 bars. K-RC-H was designed according to the seismic code and K-HPFRC-H had 150% of the original hoop spacing and 1.0% steel fiber volume fraction compared with K-RC-H. Both specimens had remarkable seismic performance without noticeable decrease in moment, but with very good energy dissipation before rebar failure. The U-bars in the joint sufficiently constrained rebar's action that pushed the cover upward. SD600 bars with $1.25l_{dt}$ had minimum slip in the joint. It was considered that the steel fiber contributed to improvement of the bending moment and joint shear distortion, and the result showed that it would be possible to increase the hoop spacing to 150% of the regular spacing.

Evaluation of the Fire Resistance Performance of Interior Anchor Type CFT Columns through Loaded Heating Test

  • Kim, Sunhee;Yom, Kyongsoo;Choi, Sungmo
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.1
    • /
    • pp.39-48
    • /
    • 2013
  • The fire resistance performance of generic CFT columns has been verified through various tests and analyses and the columns are widely used for fire resistance designs abroad. In this study, 3 groups of specimens (Non-fire protection, reinforcement with steel fiber and fire resistance paint) are suggested in order to evaluate the fire resistance performance of interior anchor type concrete-filled steel tubular columns having efficient cross-sections through loaded heating tests. Axial deformation-time relationship and in-plane temperatures are compared to evaluate the fire resistance performance of the specimens associated with variables. Suggested from the fact that the interior anchors exposed to fire exert influence on fire resistance performance due to thermal expansion, the reinforcements using steel fiber and fire resistance paint are verified to mitigate contraction and improve fire resistance performance. The result obtained from the tests of interior anchor type concrete-filled tubular columns is expected to be used for effective fire resistance design in association with previously conducted studies.

Structural Properties of High-Strength and Low-Yield-Steel Beam-Column for High-Rise Architecture Structure (건축구조용 저항복 고장력강 Beam-Column의 구조특성)

  • Kim, Jong-Sung;Meng, Ming Hua
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.1
    • /
    • pp.13-21
    • /
    • 2012
  • Recently, the development of high-strength thicker steel plate above 600MPa is becoming active due to the increase in both height and member size of architectural structure. However, such steel, which is being investigated in Korea nowadays, has possibility of limited practical application because of high design code strength and high-yield ratio. Therefore, this study performed the validation for the structural performance of beam-column with combined axial force and bending moment whether this beam-column might be attributable as an architectural purpose steel. This study was conducted from the result of monotonic loading test of beam-column, based on the material properties of low-yield, 600MPa class steel which was developed during 1988-1993 in Japan. This study might provide the fundamental database for practical research for these steel which are actively being tested in Korea.

Development of High Strength Steel Body by Hot Stamping (핫스탬핑에 의한 고강도 차체 부품 개발)

  • Lee, D.H.;Kim, T.J.;Lim, J.D.;Lim, H.J.
    • Transactions of Materials Processing
    • /
    • v.18 no.4
    • /
    • pp.304-309
    • /
    • 2009
  • Quenchable boron steel is a new type of high strength steel to reduce the weight of automobiles and maintain the safety conditions. Quenchable blanks can be hot-stamped and hardened in a water-cooled tool to achieve high strength. In this paper, new alloy for hot stamping is designed based on requirement of mechanical properties and two types of surface coating are investigated in viewpoints of oxidization and exfoliation. An automotive part of center pillar is manufactured by hot-stamping using Al-Si coated sheet. The performance of developed part is compared by static compression test and side impact crash test.

Evaluation on the Structural Performance of Hybrid Damper Using High-damping Rubber and Steel (고감쇠고무와 강재를 이용한 복합제진댐퍼의 구조성능평가)

  • Kim, Ji-Young;Jung, In-Yong;Kim, Hyung-Geun;Kim, Do-Hyun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.3
    • /
    • pp.99-106
    • /
    • 2016
  • The proposed hybrid damper installs at a coupling beam and consists of a high-damping rubber (HDR) and steel pin. The proposed hybrid damper adopted a pin-lock system acts as a viscoelastic damper under wind load (small displacement) while it behaves as a hysteretic damper under earthquake load (large displacement). In this paper, the pin-lock mechanism and structural performance of the proposed hybrid damper is evaluated through experiment. Experiments were carried out with the variables which displacement, loading frequency and steel pin quantities were used. Test results showed that the pin-lock mechanism and the performance of the hybrid damper under a large displacement were verified. Also equivalent damping ratios of HDR were increasing at a small displacement as displacement amplitudes were increasing. However HDR did not depend on frequency.

Evaluating the performance of OBS-C-O in steel frames under monotonic load

  • Bazzaz, Mohammad;Andalib, Zahra;Kafi, Mohammad Ali;Kheyroddin, Ali
    • Earthquakes and Structures
    • /
    • v.8 no.3
    • /
    • pp.699-712
    • /
    • 2015
  • Bracing structures with off-centre bracing system is one of the new resistant systems that frequently used in the frame with pin connections. High ductility, high-energy dissipation and decrease of base shear are advantages of this bracing system. However, beside these advantages, reconstruction and hard repair of off-centre bracing system cause inappropriate performance in the earthquake. Therefore, in this paper, the goal is investigating the behavior of this type of bracing system with ductile element (circular dissipater), in order to providing replacement of damaged member without needing repair or reconstruction of the general system. To achieve this purpose, some numerical studies have been performed using ANSYS software, a frame with off-centre bracing system and optimum eccentricity (OBS-C-O) and another frame with the same identifications without ductile element (OBS) has been created. In order to investigate precisely on the optimum placement of circular elements under monotonic load again three steal frames were modeled. Furthermore, the behavior of this general system investigated for the first time, linear and nonlinear behavior of these two steel frames compared to each other, to achieve the benefit of using the circular element in an off-centre bracing system. Eventually, the analytical results revealed that the performance of steel ring at the end of off-centre braces system illustrating as a first defensive line and buckling fuse in the off-centre bracing system.

Guideline for Filling Performance of Concrete for Modular LNG Storage Tanks (모듈형 LNG 저장탱크용 콘크리트 충전성능 가이드라인 제시)

  • Lee, Dong Kyu;Lee, Keon Woo;Park, Gi Joon;Kim, Sung Wook;Park, Jung Jun;Kim, Young Jin;Choi, Myoung Sung
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.2
    • /
    • pp.86-93
    • /
    • 2018
  • Recently, the use of composite steel plate concrete structural modules filled with concrete between steel plates of complex internal structure, in which a large amount of studs are installed, is increasing in order to reduce the weight and to increase workability of structures such as LNG storage tanks. However, in Korea, there is no systematic criterion for evaluating the construction performance of composite steel plate concrete structural modules. Therefore, in this study, we propose a filling guideline of concrete for composite steel plate structural module. For this purpose, high filling performance concrete with general strength range was formulated and tested for filling ability and permeability for each formulation. Rheology analysis was performed to quantitatively evaluate the flow characteristics of concrete. The reliability of $T_{500}$ and plastic viscosity was evaluated to reflect the results of each test, and a guideline for high filling concrete satisfying the reliability of 0.9 or more was derived by reflecting the results of the study on the relationship between the $T_{500}$ and plastic viscosity. Through final fill-box test, filling performance was verified and guidelines were suggested.

Anchorage Effects of Various Steel Fibre Architectures for Concrete Reinforcement

  • Abdallah, Sadoon;Fan, Mizi;Zhou, Xiangming;Geyt, Simon Le
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.3
    • /
    • pp.325-335
    • /
    • 2016
  • This paper studies the effects of steel fibre geometry and architecture on the cracking behaviour of steel fibre reinforced concrete (SFRC), with the reinforcements being four types, namely 5DH ($Dramix^{(R)}$ hooked-end), 4DH, 3DH-60 and 3DH-35, of various hooked-end steel fibres at the fibre dosage of 40 and $80kg/m^3$. The test results show that the addition of steel fibres have little effect on the workability and compressive strength of SFRC, but the ultimate tensile loads, post-cracking behaviour, residual strength and the fracture energy of SFRC are closely related to the shapes of fibres which all increased with increasing fibre content. Results also revealed that the residual tensile strength is significantly influenced by the anchorage strength rather than the number of the fibres counted on the fracture surface. The 5DH steel fibre reinforced concretes have behaved in a manner of multiple crackings and more ductile compared to 3DH and 4DH ones, and the end-hooks of 4DH and 5DH fibres partially deformed in steel fibre reinforced self-compacting concrete (SFR-SCC). In practice, 5DH fibres should be used for reinforcing high or ultra-high performance matrixes to fully utilize their high mechanical anchorage.