• Title/Summary/Keyword: high linearity

Search Result 1,060, Processing Time 0.028 seconds

The Desing of GaAs MESFET Resistive Mixer with High Linearity (선형성이 우수한 GaAs MESFET 저항성 혼합기 설계)

  • 이상호;김준수;황충선;박익모;나극환;신철재
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.2
    • /
    • pp.169-179
    • /
    • 1999
  • In this paper, a GaAs MESFET single-ended resistive mixer with high linearity and isolation is designed. The bias voltage of this mixer is applied only gate of GaAs MESFET to use the channel resistance. The LO is applied the gate and the RF is applied the drain through 7-pole hairpin bandpass filter to obtain the proper isolation thru LO-RF. The IF is extracted from the source with short circuit and lowpass filter. Using extracted equivalent circuits for LO and RF, conversion loss is calculated and compared with result of harmonic balance analysis. Measured conversion loss of this S-band down converter mixer is 8.2~10.5dB by considering the measured 3.0~3.4dB RF 7-pole hairpin bandpass filter loss and IP3in is 26.5dBm at Vg=-0.85~-1.0V in distortion performance.

  • PDF

Linearity Optimization of DC CT and a Study on the Application of HVDC System (HVDC DC CT 선형성 최적화 및 시스템 적용에 대한 연구)

  • Choi, Yong-Kil;Lee, Eun-Jae;Choi, Ho-Seok;Lee, Wook-Hwa
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.6
    • /
    • pp.758-763
    • /
    • 2014
  • These days, the advantages of DC power system are consistently stand out in korea that was a small power loss and high stability. Needs of DC power transmission technology is focused In the midst of a smart grid and environment friendly generation technology boom that is needed for next generation technology. Researches and businesses for HVDC(High Voltage Direct Current) system has been began. But, Needs of HVDC equipment and system commissioning technology are not on the rise until now. In particular, South Korea's HVDC technology is after the foot runner of advanced country and company. In addition, There is no experience for equipment verification and commissioning technology. And Experts of HVDC are rare. Who has been fully understood hardware and system as a whole, and identified all the equipment's characteristic. Recently, Academia and industry are recognized a needs of HVDC technology. But it does not received a recognition of technical value. In this paper, introduce issues when we apply the IEEE's verification method for HVDC system, especially DC current measurement system, DC CT(Direct Current Transformer), among the HVDC equipments. And Proposes remedial methods on the issue in order to recognize the necessity that was HVDC equipments's verification and commissioning technology research should be focused on.

Analysis of Cinnamic Acid, Cinnamaldehyde and 2-Methoxycinnamaldehyde in Cinnamomi Ramulus on the Market in Seoul by HPLC (서울시내 유통 중인 계지의 지표성분 함량분석)

  • Lee, Jeong-Sook;Lee, Sung-Deuk;Hwang, Kwang-Ho;Kim, Hee-Soon;Yoo, In-Sil;Han, Ki-Young;Chae, Young-Zoo
    • YAKHAK HOEJI
    • /
    • v.57 no.4
    • /
    • pp.235-240
    • /
    • 2013
  • For the quality control of traditional herbal medicine, Cinnamomi Ramulus, simultaneous determination of cinnamic acid, cinnamaldehyde, and 2-methoxycinnamaldehyde was established by using a high performance liquid chromatographic (HPLC) method with diode array detector. To separate three constituents, Eclipse XDB C18 ($5{\mu}m$, $4.6{\times}250mm$) was used with 0.1% acetic acid and acetonitrile. Validation of the chromatography method was evaluated by linearity, recovery, and precision test. Calibration curve of standard components showed excellent linearity ($R^2$ >0.9999). A simple and efficient method by HPLC was developed to evaluate the quality of traditional herbal medicines made from Cinnami Ramulus. Three major bioactive ingredients in 30 samples that are from China(8) and Vietnam(22) were separated and quantified.

Simultaneous determination of ampicillin sodium and sulbactam sodium in powder for injection by HPLC

  • Mai, Xuan-Lan;Pham, Thuy-Vy;Han, Ga-Hyun;Kum, Su-Jin;Woo, Sang-Hoon;Kang, Jong-Seong;Woo, Mi Hee;Na, Dong-Hee;Chun, In-Koo;Kim, Kyeong Ho
    • Analytical Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.147-154
    • /
    • 2019
  • Ampicillin and Sulbactam (2:1, w/w) are combined in formulation to provide broader antibacterial action in treatment of many infections. The development of analytical method for simultaneouly determine these two compounds was difficult because of the differences in their chemical structures and ratio in the formulation. Current published methods still have some limitations. In this study, we developed an alternative high-performance liquid chromatography (HPLC) assay method for simultaneously determination of ampicillin sodium and sulbactam sodium in powder for injection. Method validation of HPLC method was conducted to determine linearity, precision, accuracy, system suitability, robustness. The linearity of the calibration curves in the desired concentration range was good ($r^2$> 0.9994). RSDs of intra-day and inter-day precision obtained were less than 2.00 %. Accuracy was obtained with the recoveries in range of 98.42 % and 101.36 %. As a result of system suitability, RSD of both retention time and the peak area obtained were not more than 1.0 %. The values of plate number were more than 7000 and symmetric factors obtained were 0.8. As intermediate-precision and robustness of the developed assay, it could be expected to become valuable tools for revising the Korean Pharmacopoeia (KP XI).

Additional Thermometer Code Locking Technique for Minimizing Quantization Error in Low Area Digital Controlled Oscillators (저면적 디지털 제어 발진기의 양자화 에러 최소화를 위한 추가 서모미터 코드 잠금 기법)

  • Byeongseok Kang;Young-Sik Kim;Shinwoong Kim
    • Journal of IKEEE
    • /
    • v.27 no.4
    • /
    • pp.573-578
    • /
    • 2023
  • This paper introduces a new locking technique applicable to high-performance digital Phase-Locked Loops (DPLL). The study employs additional thermometer codes to reduce quantization errors in LC-based Digital Controlled Oscillators (DCO). Despite not implementing the entire DCO codes in thermometer mode, this method effectively reduces quantization errors through enhanced linearity. In the initial locking phase, binary codes are used, and upon completion of locking, the system transitions to thermometer codes, achieving high frequency linearity and reduced jitter characteristics. This approach significantly reduces the number of switches required and minimizes the oscillator's area, especially in applications requiring low DCO gain (Kdco), compared to the traditional method that uses only thermometer codes. Furthermore, the jitter performance is maintained at a level equivalent to that of the thermometer-only approach. The efficacy of this technique has been validated through modeling and design at the RTL level using SystemVerilog and Verilog HDL.

Motion Linearity-based Frame Rate Up Conversion Method (선형 움직임 기반 프레임률 향상 기법)

  • Kim, Donghyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.734-740
    • /
    • 2017
  • A frame rate up-conversion scheme is needed when moving pictures with a low frame rate is played on appliances with a high frame rate. Frame rate up-conversion methods interpolate the frame with two consecutive frames of the original source. This can be divided into the frame repetition method and motion estimation-based the frame interpolation one. Frame repetition has very low complexity, but it can yield jerky artifacts. The interpolation method based on a motion estimation and compensation can be divided into pixel or block interpolation methods. In the case of pixel interpolation, the interpolated frame was classified into four areas, which were interpolated using different methods. The block interpolation method has relatively low complexity, but it can yield blocking artifacts. The proposed method is the frame rate up-conversion method based on a block motion estimation and compensation using the linearity of motion. This method uses two previous frames and one next frame for motion estimation and compensation. The simulation results show that the proposed algorithm effectively enhances the objective quality, particularly in a high resolution image. In addition, the proposed method has similar or higher subjective quality than other conventional approaches.

An Empirical Study of the Analytical Measurement Range in Clinical Chemistry (분석측정범위의 실증적 평가)

  • Chang, Sang-Wu;Lee, Sang-Gon;Kim, Young-Hwan;Song, Eun-Young;Park, Yong-Won;Park, Byong-Ok;Lyu, Jae-Gi
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.38 no.2
    • /
    • pp.117-124
    • /
    • 2006
  • The analytical measurement range (AMR) is the range of analyte values that a method can directly measure on a specimen without any dilution, concentration, or other pretreatment not part of the usual assay process. The linearity of the AMR is its ability to obtain test results which are directly proportional to the concentration of analyte in the sample from the upper and lower limit of the AMR. The AMR validation is the process of confirming that the assay system will correctly recover the concentration or activity of the analyte over the AMR. The test specimen must have analyte values which, at a minimum, are near the low, midpoint, and high values of the AMR. The AMR must be revalidated at least every six months, at changes in major system components, and when a complete change in reagents for a procesure is introduced; unless the laboratory can demonstrate that changing the reagent lot number does not affect the range used to report patient test results. The AMR linearity was total protein (0-16.6), albumin (0-8.1), total bilirubin (0-18.1), alkaline phosphatase (0-1244.3), aspartate aminotransferase (0-1527.9), alanine aminotransferase (0-1107.9), gamma glutamyl transpeptidase (0-1527.7), creatine kinase (0-1666.6), lactate dehydrogenase (0-1342), high density lipoprotein cholesterol (0.3-154.3), sodium (35.4-309), creatinine (0-19.2), blood urea nitrogen (0.5-206.2), uric acid (0-23.9), total cholesterol (-0.3-510), triglycerides (0.7-539.6), glucose (0-672.7), amylase (0-1595.3), calcium (0-23.9), inorganic phosphorus (0.03-17.0), potassium (0.1-116.5), chloride (3.3-278.7). We are sure that materials for the AMR affect the evaluation of the upper limit of the AMR in the process system.

  • PDF

Evaluation of Applicability of Perovskite Dosimeter based on CsPbBr3 Material to Quality Assurance in Radiation Therapy (CsPbBr3을 기반으로 한 Perovskite 선량계의 방사선치료 Quality Assurance에 대한 적용가능성 평가)

  • Yang, Seung-Woo;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.211-216
    • /
    • 2022
  • In radiation therapy, accurate Quality Assurance (QA) is required to irradiate tumor tissue while minimizing damage to normal tissue. Therefore, a dosimeter that can accurately measure radiation is needed. The purpose of this study is to develop a highly efficient radiation dosimeter with high sensitivity by applying a particle in binder method that can reduce manufacturing costs and simplify processes to perovskite materials that are cheaper and simpler to manufacture. By evaluating the response characteristics to high-energy photon, the applicability of QA dosimeter to radiation therapy was evaluated. As a result of reproducibility evaluation, RSD at 6 MV energy was presented as 1.178% and 15 MV energy was presented as 1.141%. As a result of linearity evaluation according to linear regression analysis, R2 values of 0.9999 were presented under each condition of 6 MV and 15 MV energy. It was found that the CsPbBr3 dosimeter manufactured based on the results of reproducibility and linearity evaluation is highly applicable as a QA dosimeter in the field of therapeutic radiation. The CsPbBr3 dosimeter manufactured in this study presented more than the standard performance in the evaluation of reproducibility and linearity, and it can be used as a radiotherapy QA dosimeter through improvement.

Development for Measurement Range Extension Technique of AC High Voltage Source using Parallel Plates Electrode and Electric Field Sensor (평행판 전극과 전기장 센서를 이용한 교류 고전압 발생원의 측정범위 확장기술 개발)

  • Kang, Jeon-Hong;Ryu, Jae-Cheon;Lee, Sang-Hwa;Kim, Kyu-Tae;Kim, Myung-Soo;Han, Sang-Ok;Jung, Jae-Kap
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.9
    • /
    • pp.446-451
    • /
    • 2006
  • The output voltage value of AC high voltage source has been usually measured by employing the high voltage divider of inductive or capacitive type. In the study, we have developed a new method for measuring the output voltage up to 60kV using parallel plates electrode and electric field sensor, which are constructed by home-made. Unlikely the conventional method using a high voltage divider, this developed method makes it possible to extend the range of output voltage from known low voltage measurement to high voltage measurement. From the linearity measured between electric field and applied voltage in the output voltage range of 1kV-30kV, the output voltage value up to 60kV can be obtained by the electric field measurement using the electric field sensor. The output voltage value obtained using the method is consistent with that obtained using high voltage divider within corresponding uncertainties.

Computation of Nonlinear Elastic Strains Occurring in the Leaflet of the Edwards MIRA Mechanical Heart Valve by the Applied High Blood Pressure (혈압에 의해 Edwards MIRA 기계식인공심장판막에 발생하는 비선형 탄성변형률의 계산)

  • Kwon, Young-Joo;Yoon, Koo-Young
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.5
    • /
    • pp.493-504
    • /
    • 2008
  • This paper presents a computation of nonlinear elastic strains that may occur in the leaflet of the Edwards MIRA mechanical heart valve by the applied high blood pressure using the finite element analysis methodology. By adopting numerical analysis techniques of the commercial finite element analysis code, NISA, structural analyses of the Edwards MIRA mechanical heart valve are performed for the slight variation of leaflet thickness to get the elastic strains occurring in the leaflet while the high blood fluid pressures are applied to the leaflet surface in order that the maximum stress occurring in the leaflet may be less than the yield stress of the leaflet material(Si-Alloyed PyC). And so, only the geometric non-linearity is assumed because large geometric nonlinear elastic strains are expected rather than material nonlinear strains due to the applied high blood pressure. Computed linear and nonlinear elastic strains are compared to make sure the non-linearity of the computed elastic strain. The comparison result shows that large elastic strains occur clearly in the very thin leaflets as high blood pressures are applied. However, only the linear elastic strains occur for low blood pressures, and also for thick leaflets even for the high blood pressures. Hence the nonlinear structural analysis is very required in the structural design of a mechanical heart valve.