• Title/Summary/Keyword: high frequency data

Search Result 4,528, Processing Time 0.038 seconds

Fracture characterization with high frequency single-hole EM survey

  • Seo, Soon-Jee;Song, Yoon-Ho;Kim, Hee-Joon;Lee, Ki-Ha;Suh, Jung-Hee
    • Proceedings of the KSEEG Conference
    • /
    • 1999.04a
    • /
    • pp.90-93
    • /
    • 1999
  • We present a high frequency electromagnetic (EM) inversion scheme for detecting and characterizing a fracture using single-hole data. At high frequencies, say above tens of mega-hertz, since displacement currents cannot be ignored, electrical permittivity as well as electrical conductivity is to be considered together for analyzing the EM scattering data. In this paper, we have developed a three-step inversion scheme to map the fracture and to evaluate its electrical conductivity and permittivity. We performed EM profiling along the z-axis using three-component receivers for each source. The model was excited by a vertical magnetic dipole and the resistant magnetic fields were inverted using the non-linear least-squares method. Background resistivity and permittivity were easily obtained using vertical magnetic fields below 1 MHz and above 10 MHz, respectively. Both the vertical and dipping sheets were successfully mapped using the phase difference between 40 and 41 MHz. The electrical property of the sheet was well resolved using the information obtained in the previous two steps and secondary magnetic fields. Our study shows the potential of imaging the fracture in single-hole survey environment using the high frequency EM method.

  • PDF

Comparative Experimental Study on the Evaluation of the Unit-water Content of Mortar According to the Structure of the Deep Learning Model (딥러닝 모델 구조에 따른 모르타르의 단위수량 평가에 대한 비교 실험 연구)

  • Cho, Yang-Je;Yu, Seung-Hwan;Yang, Hyun-Min;Yoon, Jong-Wan;Park, Tae-Joon;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.8-9
    • /
    • 2021
  • The unit-water content of concrete is one of the important factors in determining the quality of concrete and is directly related to the durability of the construction structure, and the current method of measuring the unit-water content of concrete is applied by the Air Meta Act and the Electrostatic Capacity Act. However, there are complex and time-consuming problems with measurement methods. Therefore, high frequency moisture sensor was used for quick and high measurement, and unit-water content of mortar was evaluated through machine running and deep running based on measurement big data. The multi-input deep learning model is as accurate as 24.25% higher than the OLS linear regression model, which shows that deep learning can more effectively identify the nonlinear relationship between high-frequency moisture sensor data and unit quantity than linear regression.

  • PDF

A Study on SLM Method for PAPR Reduction by Scaling without Side Information in WiBro Systems (WiBro 시스템에서 스케일링을 이용한 PAPR 감소를 위한 부정보가 없는 SLM 기법 연구)

  • Lee, Jae-Sun;Gwak, Do-Young;Kim, Jin-Young
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.389-393
    • /
    • 2008
  • OFDM (Orthogonal Frequency Division Multiplexing) modulation using the orthogonal subcarriers reduces the delay spread by increasing robustness to multipath fading and can use overlapped bandwidth due to orthogonality on frequency domain. Thus data rate and spectral efficiency are increased. Because of these reason, OFDM is used for high speed data transmission for multimedia transmission as HSDPA, WiBro, WLAN. However OFDM also has drawbacks that have the high PAPR (Peak to Average Power Ratio). This high PAPR takes place because of parallel processing a number of data at once using a FFT processor. By high PAPR, amplifier doesn't act in dynamic range, so that BER performance is worse. In this paper, we reduce the PAPR using SLM(Selective Mapping). SLM doesn't effect on BER performance, but should transmit the side information for demodulation [2]. Also PAPR is higher as the number of FFT processor is larger. Thus SLM has high complexity. In this paper, we analyze the performance of SLM using scaling for no side information.

  • PDF

A Verification of the Contact Dynamics of the Current Collection System on a Test Run (실차실험에 의한 집전계의 접촉 동특성 규명)

  • Kim, Jung-Soo
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.4
    • /
    • pp.414-419
    • /
    • 2007
  • The contact characteristics of the current collection system are investigated by analyzing data collected during a test run of the Korean high speed rail vehicle. For the analysis, the signals from accelerometers and load cells attached to the various parts of the pantograph are analyzed in both the time and frequency domains. In the frequency domain, the pantograph response consists of low frequency components related to the rigid-body motion of the panhead assembly and high frequency components due to the structural vibration modes of the pantograph. The analysis shows that the inclusion of the high frequency structural vibration modes of the pantograph in the contact force calculation has a negligible effect on the predicted mean value of the contact force but significantly affects the magnitude of its fluctuations. This finding implies that numerical simulations using lumped element models of the pantograph may accurately predict the mean contact force but is limited in its capacity for predicting the fluctuation about the mean. Since the ratio of the fluctuation to the mean in the contact force increases with increased train speed, the limitation of the predictions based on numerical simulation results becomes more pronounced at higher train speed.

A Study on Radion Frequency of the Transponder System for High-speed and High-precision Train Location Detection (고속열차 위치검지를 위한 트랜스폰더 시스템 운용 주파수 연구)

  • Ahn, Il-Yeop;Sung, Nak-Myoung;Kim, Jaeho;Choi, Sung-Chan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.237-242
    • /
    • 2017
  • This paper presents development of the transponder system which provides an accurate train position, especially for supporting 400km/h high speed train. Here, we analyzed an operating frequency band of the transponder system which can be interoperable with the Eurobalise system already installed in Korea railroad as to be used for the automatic train protection (ATP). By investigating the power frequency band and its data frequency band of the transponder system, we presents the adoptable frequency band for the developed transponder system. Additionally, through the real testbed using HEMU-430X, we evaluate its performance requirement and shows interoperable operation with the Eurobalise system.

Duplex Pulse Frequency Modulation Mode Controlled Series Resonant High Voltage Converter for X-Ray Power Generator

  • Chu Enhui;Ogura Koki;Moisseev Serguei;Okuno Atsushi;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.295-300
    • /
    • 2001
  • A variety of high voltage DC power supplies employing the high frequency inverter are difficult to achieve soft switching considering a quick response and no overshoot response under the wide load variation ranges which are used in medical-use x-ray high voltage generator from 20kV to 150kV in the output voltage and from 0.5mA to 1250mA, respectively. The authors develops soft switching high voltage DC power supply designed for x-ray power generator applications, which uses series resonant inverter circuit topology with a multistage voltage multiplier instead of a conventional high voltage diode rectifier connected to the second-side of a high-voltage transformer with a large turn ratio. A constant on-time dual mode frequency control scheme operating under a principle of zero-current soft switching commutation is described. Introducing the multistage voltage multiplier, the secondary transformer turn-numbers and stray capacitance of high-voltage transformer is effective to be greatly reduced. It is proved that the proposed high-voltage converter topology with dual mode frequency modulation mode control scheme is able to be the transient response and steady-state performance in high-voltage x-ray tube load. The effectiveness of this high voltage converter is evaluated and discussed on the basis of simulation analysis and observed data in experiment.

  • PDF

An Overview of Peak-to-Average Power Ratio Reduction Schemes for OFDM Signals

  • Lim, Dae-Woon;Heo, Seok-Joong;No, Jong-Seon
    • Journal of Communications and Networks
    • /
    • v.11 no.3
    • /
    • pp.229-239
    • /
    • 2009
  • Orthogonal frequency division multiplexing (OFDM) has been adopted as a standard for various high data rate wireless communication systems due to the spectral bandwidth efficiency, robustness to frequency selective fading channels, etc. However, implementation of the OFDM system entails several difficulties. One of the major drawbacks is the high peak-to-average power ratio (PAPR), which results in intercarrier interference, high out-of-band radiation, and bit error rate performance degradation, mainly due to the nonlinearity of the high power amplifier. This paper reviews the conventional PAPR reduction schemes and their modifications for achieving the low computational complexity required for practical implementation in wireless communication systems.

Small Cell Communication Analysis based on Machine Learning in 5G Mobile Communication

  • Kim, Yoon-Hwan
    • Journal of Integrative Natural Science
    • /
    • v.14 no.2
    • /
    • pp.50-56
    • /
    • 2021
  • Due to the recent increase in the mobile streaming market, mobile traffic is increasing exponentially. IMT-2020, named as the next generation mobile communication standard by ITU, is called the 5th generation mobile communication (5G), and is a technology that satisfies the data traffic capacity, low latency, high energy efficiency, and economic efficiency compared to the existing LTE (Long Term Evolution) system. 5G implements this technology by utilizing a high frequency band, but there is a problem of path loss due to the use of a high frequency band, which is greatly affected by system performance. In this paper, small cell technology was presented as a solution to the high frequency utilization of 5G mobile communication system, and furthermore, the system performance was improved by applying machine learning technology to macro communication and small cell communication method decision. It was found that the system performance was improved due to the technical application and the application of machine learning techniques.

An Experimental Study on the Evaluation of Unit-Water Content in Mortar Using High Frequency Moisture Sensor (고주파 수분 센서를 이용한 모르타르의 단위수량 평가에 관한 실험적 연구)

  • Cho, Yang-Je;Yu, Seung-Hwan;Yang, Hyun-Min;Yoon, Jong-Wan;Park, Tae-Joon;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.17-18
    • /
    • 2021
  • The unit-water content of concrete is one of the important factors in determining the quality of concrete and is directly related to the durability of the construction structure, and the current method of measuring the unit-water content of concrete is applied by the Air Meta Act and the Electrostatic Capacity Act. However, there are complex and time-consuming problems with measurement methods. Therefore, high frequency moisture sensor was used for quick and high measurement, and unit-water content of mortar was evaluated through machine running and deep running based on measurement big data.

  • PDF

An Fundamental Study on the Measurement of Cement Mortar Unit-Water Content Using High Frequency Moisture Sensor (고주파 수분 센서를 이용한 시멘트 모르타르의 단위수량 측정에 관한 기초적 연구)

  • Cho, Yang-Je;Kim, Min-Seo;Yoon, Jong-Wan;Park, Tae-Joon;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.6-7
    • /
    • 2020
  • The unit-water content of concrete is one of the important factors in determining the quality of concrete and is directly related to the durability of the construction structure, and the current method of measuring the unit-water content of concrete is applied by the Air Meta Act and the Electrostatic Capacity Act. However, there are complex and time-consuming problems with measurement methods. Therefore, high frequency moisture sensor was used for quick and high measurement, and unit-water content of mortar was evaluated through machine running and deep running based on measurement big data.

  • PDF