• Title/Summary/Keyword: high flowing

Search Result 669, Processing Time 0.033 seconds

Effluents from copper industry: Improvised techniques

  • Duraisamy, Sankar;Saminathan, Rajagopal;Narsimman, Deepa
    • Membrane and Water Treatment
    • /
    • v.6 no.2
    • /
    • pp.103-112
    • /
    • 2015
  • In India, recycling of treated effluent plays a major role in the industry. Particularly in copper industry, recycling techniques for treated effluents adopt conventional technologies which are not energy efficient and recovery of high quality process water, free flowing salts and sludge's is very low. This paper presents an overview of enhanced modern technology for treated effluents in copper industry making it more efficient with high recovery of high quality process water and free flowing salts. Life cycle cost (LCC) would be 15-20% lower than the conventional technologies. The conventional technology can be replaced with this proposed technique in the existing and upcoming copper industries.

Cracking Characteristics of RC Beams made of High Flowing Self-Compacting Concrete (고유동 자기충전 철근 콘크리트 보의 균열특성)

  • Ahn, Tae-Ho;Kim, Jin-Cheol;Kim, Hong-Sam;Ha, Sung-Kug;Lee, Haeng-Ki;Choi, Yun-Wang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.425-426
    • /
    • 2010
  • The cracking characteristics of high flowing self-compacting concrete(HSCC) and conventional concrete(CC) was investigated. HSCC shows high crack resistance compare to CC due to self compacting properites.

  • PDF

A Fundamental Study on the Estimation of Construction Cost of High Fluidity Concrete Applying Flowing Concrete Method (유동화공법에 의해 제조한 고유동 콘크리트의 원가분석에 관한 기초적 연구)

  • 한민철;손성운;오선교;김성수;한천구
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.11a
    • /
    • pp.99-102
    • /
    • 2002
  • This paper discusses the estimation of construction cost of high fluidity concrete using segregation reducing type superplasicizer with 350kgf/cm2 of design strength and 60$\pm$5cm of slump flow in order to verify the cost down effect of high fluidity concrete compared with that of plain concrete with 350kgf/cm2 of design strength and 18cm of slump and with 210kgf/cm2 of design strength and 15cm of slump. According to research, under same strength levels, although material cost of high fluidity concrete is somewhat higher than that of plain concrete due to segregation reducing type superplasticizer, labor cost and equipment cost of high fluidity concrete is cheaper than that of plain concrete. However, based on the strength differences, high fluidity concrete shows lower material cost, labor cost and equipment cost than that of plain concrete due to decreasing in size of member and re-bar caused by high strength development of concrete.

  • PDF

Estimation of the Setting Time of the High Flowing Concrete Using Durometer (Durometer를 이용한 고유동 콘크리트의 응결시간 판정 방법)

  • Han, Min-Cheol;Shin, Yong-Sub;Han, In-Deok
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.9
    • /
    • pp.143-150
    • /
    • 2019
  • The purpose of this study was to propose how to determine the setting time related to the determination of the surface finish working time of the concrete using a Durometer, which is used as a rubber hardness meter. Two different types of Durometer were used to measure the setting time of the concrete. High flowing concrete with 40% of water to binder ratio was fabricated maintaining $600{\pm}100mm$ of slump flow. The test results indicated that the application of the Durometer resulted in a high correlation with the penetration resistance tester in both mortar and concrete. When measuring the setting time of the concrete, with properly used with Durometer, evaluation of the setting time of the concrete can be available. Therefore, it is thought that the measurement of the final set of the durometer C type can be useful to decide the limit time of the finishing operation and the time of the rejuvenation of the curing process by measuring the finishing set at 40 HD in the case of the initial set and 10 HD in the case of D type.

A Study of the Streaming Electrostatic Current in High Voltage - Large Power Transformer (초고압 대용량 변압기에서의 유동대전 현상에 관한 연구(전압무인가))

  • Park, Jae-Yun;Yun, Seung-Jin;Minari, Kogane;Lee, Duck-Chool;Kwak, Hee-Ro
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.176-179
    • /
    • 1990
  • In this paper, the pheonmena of flowing electrification is experimently studied in the model transformer of a super high voltage transformer. The current of natural terminal which is flowed by the flowing electrification is increased according to oil flow, but according to the oil temperature the current is decreased and the direction of the current is changed.

  • PDF

The Influence of the Aggregate Grain Shape on Compactability of High Flowing Concrete (고유동콘크리트의 충전특성에 미치는 골재 입형의 영향)

  • 이승한;정용욱;이원기
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.21.2-274
    • /
    • 1999
  • This study aims to examine the influence of the unit powder content of concrete and the fine aggregate ration of high flowing concrete after the improvement of grain shape of the coarse aggregate. According to the experimental results, flowbility and compating of concrete presents the best states in the S/a which has the smallest void ratio. The coarse aggregate after improvement of grain shape has been changed from 0.68 circular ratio of disc shape to 0.73 circular shape. It lead to be down 6% of fine aggregate ratio (from 47% to 41%), which is satisfactory to compacting. Also, the improvement of grain shape of the coarse aggregate lead the lowest unit powder content to be down 60kg/㎥ from (530kg/㎥ to 470kg/㎥). And about 11% unit water content can be reduced as unit powder conent is down.

  • PDF

An Experimental study on the properties and the concrete packing ability of Super Flowing concrete for adapt tp CFT (CFT에 적용하기 위한 고유동화 콘크리트의 물성 및 충전성에 관한 실험적 연구)

  • 강동현;강용학;박희곤;김종구;정근호;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.757-762
    • /
    • 2001
  • CFT concrete has high flowing, high strength and resistance to material separation to use skyscraper structure. It is considered that concrete could fill the lower part of Diaphragm up. This kinds of CFT concrete hardly apply to building below 20 stories. Using the common use strength concrete to building below 20 stories brings to reduce construction cost. This concrete is needed that valid fluidity and packing ability with unit cement content as common use strength concrete. Offering a fundamental data and proportioning in CFT concrete of below 20 stories, it is executed basic property test, analysis of proportioning and mock up test.

  • PDF

Laser Cutting Characteristics of Cold Rolled Steel Sheets (레이저를 이용한 박강판의 절단특성)

  • 이기호;김기철;이종훈
    • Journal of Welding and Joining
    • /
    • v.13 no.4
    • /
    • pp.113-121
    • /
    • 1995
  • This study deals with the quality and the optimum range of laser cutting process. Cold rolled steel sheets for automobile application were cut by a high power CO$_{2}$ laser system with beam quality of TEM$_{\infty}$ mode. Both process parameters such as travel speed and assist gas pressure, and quality factors were considered to optimize the laser cutting. It was revealed that the thinner the sheet thickness, the less effect of oxidation energy for contributing the cutting process. High speed photographs demonstrated that molten spot on the cut surface moved in a random and vigorous manner according to its viscosity and the flowing direction of assist gas, which resulted in so called striation. Laser cutting produced a very smooth surface of average roughness(Ra) about less than 1.5.mu.m at the optimum range. It was also shown that the characteristics of dross formation was influenced by the flowing durection of assist gas and the fluidity of molten metal drop..

  • PDF

Development of Flowability Measurement Device using Laser Diode (레이져 다이오드를 이용한 유동성능 측정장치 개발)

  • Jeong, Jae-Gwon;Kim, Kyung-Hwan;Eom, Joo-Han;Choi, Yun-Wang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.247-248
    • /
    • 2009
  • Testing standards both nationally and abroad for high flowing concrete are presented about slump flow and the time to reach 500 mm. However, the slump flow testing method to measure flow properties of high flowing concrete results in measurement error due to the differences in each person's perception of the test. This study introduced laser diode to reduce such testing errors from personal differences in experimental procedure.

  • PDF