• 제목/요약/키워드: high field

검색결과 16,208건 처리시간 0.044초

Determination of seismic hazard and soil response of a critical region in Turkey considering far-field and near-field earthquake effect

  • Sonmezer, Yetis Bulent;Celiker, Murat
    • Geomechanics and Engineering
    • /
    • 제20권2호
    • /
    • pp.131-146
    • /
    • 2020
  • Evaluation of earthquake impacts in settlements with a high risk of earthquake occurrence is important for the determination of site-specific dynamic soil parameters and earthquake-resistant structural planning. In this study, dynamic soil properties of Karliova (Bingol) city center, located near to the intersection point of the North Anatolian Fault Zone and the East Anatolian Fault Zone and therefore having a high earthquake risk, were investigated by one-dimensional equivalent linear site response analysis. From ground response analyses, peak ground acceleration, predominant site period, 0.2-sec and 1-sec spectral accelerations and soil amplification maps of the study area were obtained for both near-field and far-field earthquake effects. The average acceleration spectrum obtained from analysis, for a near-field earthquake scenario, was found to exceed the design spectra of the Turkish Earthquake Code and Eurocode 8. Yet, the average acceleration spectrum was found to remain below the respective design spectra of the two codes for the far-field earthquake scenario. According to both near- and far-field earthquake scenarios in the study area, the low-rise buildings with low modal vibration durations are expected to be exposed to high spectral acceleration values and high-rise buildings with high modal vibration durations will be exposed to lower spectral accelerations. While high amplification ratios are observed in the north of the study area for the near-distance earthquake scenario, high amplification ratios are observed in the south of the study area for the long-distance earthquake scenario.

3.0 T MRI를 위한 Parallel-Transmission RF 코일 구조의 비교와 최적화 (Comparison and Optimization of Parallel-Transmission RF Coil Elements for 3.0 T Body MRI)

  • 오창현;이흥규;류연철;현정호;최혁진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.61-63
    • /
    • 2007
  • In high field (> 3 T) MR imaging, the magnetic field inhomogeneity in the target object increases due to the nonuniform electro-magnetic characteristics and relatively high Larmor frequency. Especially in the body imaging, the effect causes more serious problems resulting in locally high SAR(Specific Absorption Ratio). In this paper, we propose an optimized parallel-transmission RF coil element structure and show the utility of the coil by FDTD simulations to overcome the unwanted effects. Three types of TX coil elements are tested to maximize the efficiency and their driving patterns(amplitude and phase) optimized to have adequate field homogeneity, proper SAR level, and sufficient field strength. For the proposed coil element of 25 cm ${\times}$ 8 cm loop structure with 12 channels for a 3.0 T body coil, the 73% field non-uniformity without optimization was reduced to about 26% after optimization of driving patterns. The experimental as well as simulation results show the utility of the proposed parallel driving scheme is clinically useful for (ultra) high field MRI.

  • PDF

고전계 전기산화에 의한 나노다공성 알루미나 멤브레인의 제조 (Fabrication of Nanoporous Alumina Membrane by High- Field Anodization)

  • 김민우;현상철;하윤철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.45-45
    • /
    • 2010
  • Nanoporous anodic alumina membranes (NAAM) with high aspect ratio, self-ordered pore array were fabricated by high-field 2-step anodization method. High voltages of 80, 100, 120 and 140 V as well as 40 V for comparison were applied to an aluminum anode with respect to a Pt cathode immersed both in 0.3M oxalic acid solution in order to investigate the self-ordering characteristics of the nanoporous structure. The pore structures, including interpore distance, pore size, pore density, and porosity as well as the ordering characteristic were analyzed using field-enhanced scanning electron microscopy (FE-SEM) and the corresponding Fourier-transformed images. The nanoporous structure could be produced for all the voltage conditions, but the well-ordered through-hole pore without a branched structure seemed to occur only at 40 and 140 V. It turned out that the growth rate under 140 V high-field anodization was about 40 times higher than under conventional 40 V mild anodization, which enabled the fast fabrication of self-ordered, high aspect ratio NAAMs.

  • PDF

Rock mechanics and wellbore stability in Dongfang 1-1 Gas Field in South China Sea

  • Yan, Chuanliang;Deng, Jingen;Cheng, Yuanfang;Yan, Xinjiang;Yuan, Junliang;Deng, Fucheng
    • Geomechanics and Engineering
    • /
    • 제12권3호
    • /
    • pp.465-481
    • /
    • 2017
  • Thermal effect has great influence on wellbore stability in Dongfang 1-1 (DF 1-1) gas field, a reservoir with high-temperature and high-pressure. In order to analyze the wellbore stability in DF1-1 gas field, the variation of temperature field after drilling was analyzed. In addition, the effect of temperature changing on formation strength and the thermal expansion coefficients of formation were tested. On this basis, a wellbore stability model considering thermal effect was developed and the thermal effect on fracture pressure and collapse pressure was analyzed. One of the main challenges in this gas field is the decreasing temperature of the wellbore will reduce fracture pressure substantially, resulting in the drilling fluid leakage. If the drilling fluid density was reduced, kick or blowout may happen. Therefore, the key of safe drilling in DF1-1 gas field is to predict the fracture pressure accurately.

저밀도 폴리에틸렌에 있어서 전압 파형의 두께 의존성 (Film Thickness Dependences of Ac High Field Dissipation Current Waveform for LDPE)

  • 윤주호;최용성;문종대;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.349-350
    • /
    • 2007
  • Polyethylene is widely used as the insulator for power cable. To investigate the conduction mechanism for power cable insulation under ac high field, it is very important to acquire the dissipation current under actual running field. Recently, we have developed the unique system, which make possible to observe the nonlinear dissipation current waveform. In this system, to observe the nonlinear properties with high accuracy, capacitive current component is canceled by using inverse capacitive current signal instead of using the bridge circuit for canceling it. As the results of these estimations, it was found that the dissipation current will depend on not only the instantaneous value of electric field but also the time differential of applied electric field due to taking a balance between applied field and internal field. Furthermore, two large peaks of dissipation current for each half cycle were observed under certain condition. In this paper, to clarify the reason why it shows two peaks for each half cycle, the film thickness dependences of dissipation current waveforms were observed by using the three different thickness LDPE films.

  • PDF

Design Optimization and Performance of High Voltage Composite Bushing

  • 조한구;강형경
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.234-234
    • /
    • 2009
  • This paper illustrates the use of electric field computation to optimize the design of high voltage composite bushing. In the bushing, a high electric stress occurred between field shaper and central conductor by the closely space. Also coaxial cylindrical shield has a great height along the axis to control an electric field. Consequently, all the potentials are raised axially along the field shaper and electric stress is concentrated on a part of the surface of the FRP tube near the upper end of the field shaper. Maxwell 2D simulator based on the boundary element method was also introduced in order to verify the reliability of the polymer bushing. The optimized design uses internal elements for electric stress grading at critical parts of the bushing.

  • PDF

초고압 컴포지트 부싱의 최적설계 및 성능에 관한 연구 (Design Optimization and Performance of High Voltage Composite Bushing)

  • 조한구;김광용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.35-35
    • /
    • 2010
  • This paper illustrates the use of electric field computation to optimize the design of high voltage composite bushing. In the bushing, a high electric stress occurred between field shaper and central conductor by the closely space. Also coaxial cylindrical shield has a great height along the axis to control an electric field. Consequently, all the potentials are raised axially along the field shaper and electric stress is concentrated on a part of the surface of the FRP tube near the upper end of the field shaper. Maxwell 2D simulator based on the boundary element method was also introduced in order to verify the reliability of the polymer bushing. The optimized design uses internal elements for electric stress grading at critical parts of the bushing.

  • PDF

인삼포 토양의 환경요인과 미생물분포 (Environmental factors and the distribution of soil microorganisms in ginseng field)

  • 신현성;이민웅
    • 미생물학회지
    • /
    • 제24권2호
    • /
    • pp.184-193
    • /
    • 1986
  • Interrelation between environmental influences on soil microorganisms and it's effect on disease development in ginseng (Panax ginseng C.A. Meyer) field were studied to obtain a preventive measures against the root rot of ginseng caused by soil-borne pathogens in soil in three major Korean ginseng producing areas such as Kumsan, Goesan and Poonggi. Populations of actinomycetes were relatively high in fall season from September to November. Their numbers were highly populated in healthy plot in field than replanted disease field of ginseng, whereas ratio of Trichoderma spp to actinomycetes increased in healthy plot of field indicating the higher numbers of Trichoderma spp pressented in healthy plot field. The numbers of propagules of Trichoderma spp generally increased in early summer through early fall season. Their numbers were also highly populated in the healthy plot of fields. The contents of organic matter and phosphate in healthy plot of field were somewhat high, and phophate/organic matter ratio and Mg content were high in diseased replanted field. All of the soil samples showed a weak acidic pH from 4.5 to 4.7. Soilmoisture content was increased during winter season and it did not show any significant changes curing the growing period, showing 24.6% in healthy plot in field and 19.5% in deseased plot in field respectively. Soil temperature was highest in July and August and lowest in January and February.

  • PDF

액체질소를 사용하는 초전도 고전압 전력기기의 절연 특성 연구 (Analytical and Experimental studies on Dielectric Characteristics of High Voltage Superconducting Machines in Liquid Nitrogen)

  • 나진배;고태국;강형구;석복렬;김태중
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권1호
    • /
    • pp.46-50
    • /
    • 2011
  • The electrical insulation design of high voltage superconducting fault current limiters (SFCLs) should be confirmed to be applied for the stabilization of the power grid. This paper describes numerical analysis and AC dielectric experiments for developing high voltage SFCLs. The electric field distributions between applied high voltage part and ground were calculated by finite element method (FEM) simulation tool and AC criterion of liquid nitrogen at 200 kPa was calculated from correlation between the field utilization factor and FEM simulation results. This paper deals with ceonceptual insulation design of a 154 kV class single-phase no-inductively wound solenoid type SFCL which was focused on gap distance between the cryostat and superconducting coils. Furthermore, the shield ring effect was confirmed to reduce maximum electric field at applied high voltage part.

고전압 전력기기 개발을 위한 기중 절연파괴특성 분석에 관한 연구 (A Study on the Lightning Impulse Dielectric Characteristics of Air for the Development of Air-Insulated High Voltage Apparatuses)

  • 남석호;강형구
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.1005-1010
    • /
    • 2011
  • The accidents caused by dielectric instability have been increasing in power grid. It is important to enhance the dielectric reliability of a high voltage apparatus to reduce the damage from electrical hazards. To develop an electrically reliable high voltage apparatus, the experimental study on the electrical breakdown field strength is indispensable, as well as theoretical approach. In this paper, the lightning impulse breakdown characteristics considering utilization factors are studied for the establishment of insulation design criteria of an high voltage apparatus. The utilization factors are represented as the ratio of mean electric field to maximum electric field. Dielectric experiments are performed by using several kinds of sphere-plane electrode systems made of stainless steel. As a result, it is found that dielectric characteristics are affected by not only maximum electric field intensity but also utilization factors of electrode systems. The results are expected to be applicable to designing the air-insulated high voltage apparatuses.