Verification of Radiation Therapy Planning Dose Based on Electron Density Correction of CT Number: XiO Experiments (컴퓨터영상의 전자밀도보정에 근거한 치료선량확인: XiO 실험)

  • Choi Tae-Jin;Kim Jin-Hee;Kim Ok-Bae
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.105-113
    • /
    • 2006
  • This study peformed to confirm the corrected dose In different electron density materials using the superposition/FFT convolution method in radiotherapy Planning system. The experiments of the $K_2HPO_4$ diluted solution for bone substitute, Cork for lung and n-Glucose for soft tissue are very close to effective atomic number of tissue materials. The image data acquisited from the 110 KVp and 130 KVp CT scanner (Siemes, Singo emotions). The electron density was derived from the CT number (H) and adapted to planning system (Xio, CMS) for heterogeneity correction. The heterogeneity tissue phantom used for measurement dose comparison to that of delivered computer planning system. In the results, this investigations showed the CT number is highly affected in photoelectric effect in high Z materials. The electron density in a given energy spectrum showed the relation of first order as a function of H in soft tissue and bone materials, respectively. In our experiments, the ratio of electron density as a function of H was obtained the 0.001026H+1.00 in soft tissue and 0.000304H+1.07 for bone at 130 KVp spectrum and showed 0.000274H+1.10 for bone tissue in low 110 KVp. This experiments of electron density calibrations from CT number used to decide depth and length of photon transportation. The Computed superposition and FFT convolution dose showed very close to measurements within 1.0% discrepancy in homogeneous phantom for 6 and 15 MV X rays, but it showed -5.0% large discrepancy in FFT convolution for bone tissue correction of 6 MV X rays. In this experiments, the evaluated doses showed acceptable discrepancy within -1.2% of average for lung and -2.9% for bone equivalent materials with superposition method in 6 MV X rays. However the FFT convolution method showed more a large discrepancy than superposition in the low electron density medium in 6 and 15 MV X rays. As the CT number depends on energy spectrum of X rays, it should be confirm gradient of function of CT number-electron density regularly.

  • PDF

EFFECTS OF WAVE-PARTICLE INTERACTIONS ON DIFFUSIVE SHOCK ACCELERATION AT SUPERNOVA REMNANTS

  • Kang, Hyesung
    • Journal of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.49-63
    • /
    • 2013
  • Nonthermal radiation from supernova remnants (SNRs) provides observational evidence and constraints on the diffusive shock acceleration (DSA) hypothesis for the origins of Galactic cosmic rays (CRs). Recently it has been recognized that a variety of plasma wave-particle interactions operate at astrophysical shocks and the detailed outcomes of DSA are governed by their complex and nonlinear interrelationships. Here we calculate the energy spectra of CR protons and electrons accelerated at Type Ia SNRs, using time-dependent, DSA simulations with phenomenological models for magnetic field amplification due to CR streaming instabilities, Alf$\acute{e}$enic drift, and free escape boundary. We show that, if scattering centers drift with the Alf$\acute{e}$en speed in the amplified magnetic fields, the CR energy spectrum is steepened and the acceleration efficiency is significantly reduced at strong CR modified SNR shocks. Even with fast Afv$\acute{e}$nic drift, DSA can still be efficient enough to develop a substantial shock precursor due to CR pressure feedback and convert about 20-30% of the SN explosion energy into CRs. Since the high energy end of the CR proton spectrum is composed of the particles that are injected in the early stages, in order to predict nonthermal emissions, especially in X-ray and ${\gamma}-ray$ bands, it is important to follow the time dependent evolution of the shock dynamics, CR injection process, magnetic field amplification, and particle escape. Thus it is crucial to understand the details of these plasma interactions associated with collisionless shocks in successful modeling of nonlinear DSA.

Characterization and experimental investigation for gamma-ray shielding competence of basalt-doped polyethylene nanocomposites

  • I.A. El-Mesady;F.I. El-Agawany;H. El-Samman;Y.S. Rammah;A. Hussein;R.A. Elsad
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.477-484
    • /
    • 2024
  • Experimental investigations on gamma - rays attenuation parameters and dielectric spectroscopic properties were done on a polymeric mixture with chemical composition (100-x) polyethylene + x basalt, where x = 0, 1, 3, 5, 10, and 20 wt%. Using the melting blending technique,six nanocomposite polymeric samples were prepared. The linear attenuation coefficient µ of each prepared set of samples was measured using a gamma-ray spectrometer including High Purity Germanium detector (HPGe) at energies 662.5, 1173.24, and 1332.51 keV. Based on the measured values of (µ) and sample density, the other effective shielding parameters were calculated. The values of µ showed an increase with increasing the dopant ratios from 0.0 up to 20.0 wt%. In addition, the µ values decreased with the photon's energy. The µ values were found 0.0847 up to 0.1175 cm-1, 0.0571 up to 0.0855 cm-1, and 0.0543 up to 0.075 cm-1 at 662.5, 1173.24, and 1332.51 keV. for B0 up to B20, respectively. The ATR spectroscopy was done on the prepared samples, and a good evidence of adding the filler to the pure polyethylene (HDPE) was obtained. Besides, an enhancement in dielectric constant by insertion of basalt NPs also recorded and can be attributed to the large dielectric constant of basalt compared to pure HDPE.

The Change of Collected Light According to Changing of Reflectance and Thickness of CdWO4 Scintillator for High Energy X-ray Imaging Detection (고에너지 X-선 영상검출을 위한 CdWO4 섬광체 두께와 반사체의 반사율 변화에 따른 광 수집량의 변화)

  • Lim, Chang Hwy;Park, Jong-Won;Lee, Junghee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.12
    • /
    • pp.1704-1710
    • /
    • 2020
  • The high-energy X-ray imaging detector used for container inspection uses a thick scintillator to effectively acquire X-rays. X-ray incident on the scintillator is generally up to 9MeV. Therefore, to effectively collect X-ray, it is necessary to use a thick scintillator. To collect the light generated by the reaction between X-ray and scintillator, an optical-sensor must be combined with the scintillator. In this study, a study on the design conditions of the detector using a CdWO4 and a small sensor is described. To calculate the collected light according to the change of the scintillator thickness and the reflectance of surface, MCNP6 and DETECT2000 were used. As a result of calculating, it was confirmed that when the reflectance of the surface was low, it was appropriate to select a scintillator with a thickness of 15 to 20-mm, but as the reflectance increased, it was confirmed that it was appropriate to select a CdWO4 with a thickness of 25 to 30-mm.

Property of Carbon Layer for C/W Multilayer Mirror (C/W 다층박막 거울의 탄소층 특성 Property of Carbon Layer for C/W Multilayer Mirror)

  • Park, Byoung-Hun;Choi, Hyung-Wouk;Oh, Sun-Ju;Yoon, Kwon-Ha;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.4
    • /
    • pp.33-36
    • /
    • 2010
  • Multilayer mirrors are very useful for applications of high energy X-ray. X-rays of high energy require very small thickness, a few nanometers, in the d-spacing of a multilayer mirror. Each layer is composed of a multilayr mirror influences to interfacial roughness or interdiffusion which gives rise to degrade specular reflection. Carbon layer of 1 nm thick in a C/W multilayer mirror of 3.25 nm d-spacing was examined. Carbon as well as tungsten layers were very uniform, and there was no micro-structure in carbon layers. However, interdiffusion between carbon and tungste layers was observed by a transmission electron microscope.

A Study on Radiation Beam Quality Set-up of Mammography Equipment and Average Glandular Dose (유방 촬영 장치의 국제 규격 Beam Quality 기준에 따른 평균 선량 평가에 관한 연구)

  • Park, Yoon-Hee;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.303-308
    • /
    • 2022
  • Mammography using X-rays is currently the most used for early diagnosis of breast cancer. As the frequency of use of X-ray devices increases, interest in radiation hazards caused by mammography is increasing. Therefore, in this study, in order to measure the exposure dose of the mammary gland in X-ray mammography that requires high contrast and high resolution, the international Atomic Energy Agency (IAEA) stipulates the international standards presented by IEC 62220-1-2: 2015. Based on the beam quality criteria of the recommendation, we tried to present a guideline for evaluating the average mammary gland dose. As a result, the average streamline dose value of the 4.5 cm PMMA phantom was 2.3 mGy at the maximum within the 30 kV range, and was evaluated to be 1.19 mGy based on 28 kV.

Development of X-Ray Array Detector Signal Processing System (X-Ray 어레이 검출 모듈 신호처리 시스템 개발)

  • Lim, Ik-Chan;Park, Jong-Won;Kim, Young-Kil;Sung, So-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.10
    • /
    • pp.1298-1304
    • /
    • 2019
  • Since the 9·11 terror attack in 2001, the Maritime Logistics Security System has been strengthened and required X-ray image for every imported cargos from manufacturing countries to United States. For scanning cargos, the container inspection systems use high energy X-rays for examination of contents of a container to check the nuclear, explosive, dangerous and illegal materials. Nowadays, the X-ray cargo scanners are established and used by global technologies for inspection of suspected cargos in the customs agency but these technologies have not been localized and developed sufficiently. In this paper, we propose the X-ray array detector system which is a core component of the container scanning system. For implementation of X-ray array detector, the analog and digital signal processing units are fabricated with integrated hardware, FPGA logics and GUI software for real-time X-ray images. The implemented system is superior in terms of resolution and power consumption compared to the existing products currently used in ports.

A Study on the dose distribution and the accuracy of the system for small fields of high energy x-rays (고에너지 X-선 소조사야의 선량분포 및 계측에 관한 연구)

  • 이호남;지광수;김재휴;지영훈
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.32-44
    • /
    • 1995
  • I. 제 목 고에너지 X-선 소조사야의 선량분포 및 계측에 관한 연구 II. 연구의 목적 및 중요성 최근 수술이 어려운 뇌종양등에 대한 방사선수술법(Radiosurgery)이 관심의 대상이 되고 있다. 방사선수술법은 크게 나누어 200여개의 Co-60이 장착된 장치(Gamma Knife)를 이용하는 방법과, X-선치료기를 이용하는 방법은 몇개의 보조기구를 설치하면 가능한 매우 경제적인 방법이다. 따라서 Microtron을 이용한 방사선수술의 기초자료확보를 위하여 소조사야에 대한 선량과 선량분포의 측정 및 계산을 실시하였다. III. 연구의 내용 및 범위 Microtron으로부터 조사되는 6MV, 10MV, 21MV X-선의 지름 3cm이하 소조사야에 대한 정확한 선량 및 선량분포 자료를 확보하기 위해, 가. Microtron치료기와 보조장치등에 대한 정밀도 계측 및 평가 나. 보조 Collimator의 적당한 크기와 재료의 선택 및 설계, 제작. 다. 에너지와 조사야 크기 각각에 대한 여러측정장치(Ion chamber, Diode detector, TLD 및 Film등)를 이용한 선량 및 선량분포 측정. 라. 측정값들의 비교, 검토 및 측정된 자료에 의한 선량 및 선량분포의 계산을 수행했다. IV. 연구결과 및 활용에 대한 건의 본 연구에서 얻은 결과는 다음과 같다. 가. Microtron치료기와 보조장치등의 정확도의 허용 오차범위내에서 잘 일치하였다. 나. 보조 collimater adpator는 총 길이 24cm로 하였으며 재질로는 두랄미늄을 사용하였고, 보조 collimator는 low melting alloy를 사용하였으며 소조사야 크기의 정확도는 0.5mm이내에서 매우 잘 일치 하였다. 다. 방사선 수술법의 에너지 선택에 중요한 요소중의 하나인 penumbra는 6MV X-선에서 가장 적게 나타났으며 라. 소조사면에 대한 깊이-선량 백분율곡선은 모든 에너지에서 조사면이 작아질수록 표면으로 이동하는 경향을 보였다. 이상의 결과로부터 방사선 수술을 시행할 경우 수십억원에 이르는 장비의 도입이나 새로운 시설 없이 Microtron에서 조사되는 고에너지 X-선을 이용할 수 있을 것으로 사료된다. 또한 새로 구입한 측정기나 보조 Collimator를 이용하여 소조사야에 대한 선량측정기술을 습득함으로써 일반적인 소조사야의 방사선치료나 회전치료등에 활용할 수 있다.

  • PDF

The Measurement of Dose Distribution in the Presence of Air Cavity and Underdosing Effect Result from Lack of Electronic Equilibrium (조사면내 공동의 존재에 따른 선량분포의 변화측정)

  • Jo, Jeong-Hui;Bang, Dong-Wan;Park, Jae-Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.8 no.1
    • /
    • pp.75-81
    • /
    • 1996
  • When high energy photon beam is incident upon an air cavity interface the effect of ionization build-up observed . This phenomenon is resulting from the surface layers of the lesions are significant deficiency of electrons reaching the layers because of the replacement, of solid scattering material by the air cavity, that is lack of electronic equilibrium. Measurement have been made in an acrylic phantom with a parallel plate chamber and high energy photon beams, CO-60, 4MV, 6MV and 10MV X-rays have been investigated. The result of our study show that a significant effect was measured and was determined to be very dependent on field size, air cavity dimension and photon energy. The reductions were much larger for 10MV beam, underdosage at the interface was 12, 12.2, 16.9 and $20.6\%$ for the CO-60, 4MV, 6MV and 10MV, respectively. It was found that this non-equilibrium effect at the interface is more severe for the higher energy beams than that of lower energy beams and the larger cavity dimensions the larger beam reductions occur. This problem is of clinical concern when lesions such as carcinoma beyond air cavities are irradiated, such as larynx, glottic and the patients with maxillectomy and ethmoidectomy and so forth.

  • PDF

Development of Superconducting Transition Edge Sensors for Gamma Ray Detection (감마선 검출을 위한 초전도 상전이 센서)

  • Lee, Young-Hwa;Kim, Yong-Hamb
    • Progress in Superconductivity
    • /
    • v.9 no.2
    • /
    • pp.162-166
    • /
    • 2008
  • We are developing a sensitive gamma ray spectrometer based on superconducting transition edge sensors. The detector consists of a small piece of high purity Sn as an absorber and a Ti/Au bilayer as a temperature sensor. It is designed to measure the thermal signal caused by absorption of gamma rays. The mechanical support and the thermal contact between the absorber and the thermometer were made with Stycast epoxy. The bilayer was formed by e-beam evaporation and patterned by wet etching on top of a $SiN_X$ membrane. A sharp superconducting transition of the film was measured near 100 mK. When the film was biased to the edge of the transition, signals were observed due to single photon absorption emitted from an $^{241}Am$ source. The measured spectrum showed several characteristic peaks of the source including 59.5 keV gamma line. The full with at half maximum was about 900 eV for the 59.5 keV gamma line. The background was low enough to resolve low energy lines. Considerations to improve the energy resolution of the gamma ray spectrometer are also discussed.

  • PDF