Browse > Article
http://dx.doi.org/10.6109/jkiice.2020.24.12.1704

The Change of Collected Light According to Changing of Reflectance and Thickness of CdWO4 Scintillator for High Energy X-ray Imaging Detection  

Lim, Chang Hwy (M1 International)
Park, Jong-Won (Ocean System Engineering Research Division, KRISO)
Lee, Junghee (Ocean System Engineering Research Division, KRISO)
Abstract
The high-energy X-ray imaging detector used for container inspection uses a thick scintillator to effectively acquire X-rays. X-ray incident on the scintillator is generally up to 9MeV. Therefore, to effectively collect X-ray, it is necessary to use a thick scintillator. To collect the light generated by the reaction between X-ray and scintillator, an optical-sensor must be combined with the scintillator. In this study, a study on the design conditions of the detector using a CdWO4 and a small sensor is described. To calculate the collected light according to the change of the scintillator thickness and the reflectance of surface, MCNP6 and DETECT2000 were used. As a result of calculating, it was confirmed that when the reflectance of the surface was low, it was appropriate to select a scintillator with a thickness of 15 to 20-mm, but as the reflectance increased, it was confirmed that it was appropriate to select a CdWO4 with a thickness of 25 to 30-mm.
Keywords
$CdWO_4$; MCNP6; DETECT2000; Container Inspection System; X-ray;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 P. M. Evans, M. A. Mosleh-Shirazi, E. J. Harris, and J. Seco, "Monte Carlo and Lambertian light guide models of the light output from scintillation crystals at megavoltage energies," Medical Physics, vol. 33, no. 6, pp. 1797-1809, May. 2006.   DOI
2 D. Sharma, C. Sze, H. Bhandari, V. Nagarkar, and A. Badano, "Depth-of-interaction estimates in pixelated scintillator sensors using Monte Carlo techniques," Nuclear Instruments and Methods in Physics Research A, vol. 841, pp. 117-123, 2017.   DOI
3 P. Ghorbani, D. Sardari, R. Azimiradb, and M. Hosntalab, "Assessment of optical photon collection in a large plastic scintillator using Geant4-Gate code," Optik, vol. 158, pp. 305-311, 2018.   DOI
4 G. Chen, "Understanding X-ray cargo imaging," Nuclear Instruments and Methods in Physics Research B, vol. 241, pp. 810-815, Aug. 2005.   DOI
5 C. Michail, V. Koukou, N. Martini, G. Saatsakis, N. Kalyvas, A. Bakas, I. Kandarakis, G. Fountos, G. Panayiotakis, and I. Valais, "Luminescence efficiency of cadmium tungstate (CdWO4) single crystal for medical imaging applications," Crystals, vol. 10, no. 429, pp. 1-16, May. 2020.
6 J. Lee, C. H. Lim, J. Park, I. Kim, M. K. Moon, and Y. Lim, "The effect of grid ratio and material of anti-scatter grid on the scatter-to-primary ratio and the signal-to-noise ratio improvement factor in container scanner x-ray imaging," Radiation Protection and Research, vol. 42, no. 4, pp. 197-204, Oct. 2017.   DOI
7 T. T. Monajemi, S. Steciw, B. G. Fallone, and S. Rathee, "Modeling scintillator-photodiodes as detectors for megavoltage CT," Medical Physics, vol. 31, no. 5, pp. 1225-1234, May. 2004.   DOI
8 A. Badano, R. M. Gagne, B. D. Gallas, R. J. Jennings, J. S. Boswell, and K. J. Myers, "Lubberts effect in columnar phosphors," Medical Physics, vol. 31, no. 11, pp. 3122-3131, Nov. 2004.   DOI