• Title/Summary/Keyword: high electric field

Search Result 1,498, Processing Time 0.03 seconds

A Study on the Measurements of Parameters Affecting the Breakdown Mechanism of a Large Air Spacing (이격거리가 큰 전극의 공기 절연파괴에 영향을 미치는 인자측정에 관한연구)

  • Cho, Yun-Ok;Choi, Young-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.756-760
    • /
    • 1988
  • The paper presents the measurement results on the parameters affecting the breakdown mechanism of a large air spacing under switching impulse voltages. Measured parameters are the velocities of leader channels, predischarge currents, electric charges injected into the rod-plane air gap and electric field intensities on the plane. For the 3m air gap under switching impulse voltages, the velocities of leader channel have been measured to be of 1cm/${\mu}s$ - 5cm/${\mu}s$, electric field intensity of 2kv/cm, predischarge current of 1.2A - 1.6A, the charges injected into the air gap of 11 - 40 ${\mu}$C for 400-887kV impulse voltages.

  • PDF

Design and Manufacture Technology of Polymer Bushing for Pole Mount Transformer (배전급 주상 변압기용 폴리머 부싱 설계 및 제조기술)

  • Cho, Han-Goo;Lee, Un-Yang;Cheon, Jong-Uk;Park, Young-Doo;Kang, Young-Kil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.145-149
    • /
    • 2005
  • Recently, polymer insulator and bushing that are used for high voltage application have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. The pole mount transformer installed in distribution system is acting direct role in supply of electric power and the electric power device should drive safely for long tenn. In this paper, the polymer bushing of pole transformer is designed adaptively to current assembly method, designed bushing is manufactured on basis of that result. The electric field of designed transformer is investigated by FEM program.

  • PDF

Planar-type Electric Field Sensor for Measuring the Time-varying Electric Fields (시변전계 측정용 평판형 전계센서)

  • Lee, Bok-Hee;Lee, Sung-Hun;Kil, Gyung-Suk
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.287-289
    • /
    • 1994
  • This paper deals with the planar-type electric field sensor which can measure the time-varying electric fields. The theoretical principle and design rule of the sensor are introduced, and also the calibration and application investigations are carried out. From the calibration experiments, the frequency bandwidth of the measurement system ranges from 160 [Hz] to 25 [MHz]. At a high voltage laboratory, the electric fields caused by the impulse voltage and oscillating transient voltage are measured by the proposed sensor. Obtained results are well agreement with the applied voltage waveforms.

  • PDF

Diamond Schottky Barrier Diodes With Field Plate (필드 플레이트가 설계된 다이아몬드 쇼트키 장벽 다이오드)

  • Chang, Hae Nyung;Kang, Dong-Won;Ha, Min-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.4
    • /
    • pp.659-665
    • /
    • 2017
  • Power semiconductor devices required the low on-resistance and high breakdown voltage. Wide band-gap materials opened a new technology of the power devices which promised a thin drift layer at an identical breakdown voltage. The diamond had the wide band-gap of 5.5 eV which induced the low power loss, high breakdown capability, low intrinsic carrier generation, and high operation temperature. We investigated the p-type pseudo-vertical diamond Schottky barrier diodes using a numerical simulation. The impact ionization rate was material to calculating the breakdown voltage. We revised the impact ionization rate of the diamond for adjusting the parallel-plane breakdown field at 10 MV/cm. Effects of the field plate on the breakdown voltage was also analyzed. A conventional diamond Schottky barrier diode without field plate exhibited the high forward current of 0.52 A/mm and low on-resistance of $1.71{\Omega}-mm$ at the forward voltage of 2 V. The simulated breakdown field of the conventional device was 13.3 MV/cm. The breakdown voltage of the conventional device and proposed devices with the $SiO_2$ passivation layer, anode field plate (AFP), and cathode field plate (CFP) was 680, 810, 810, and 1020 V, respectively. The AFP cannot alleviate the concentration of the electric field at the cathode edge. The CFP increased the breakdown voltage with evidences of the electric field and potential. However, we should consider the dielectric breakdown because the ideal breakdown field of the diamond is higher than that of the $SiO_2$, which is widely used as the passivation layer. The real breakdown voltage of the device with CFP decreased from 1020 to 565 V due to the dielectric breakdown.

A Study on the Current Detector with Non Contact Type (비접촉식 전류 검출 장치에 관한 연구)

  • Kim, Ki-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.5
    • /
    • pp.351-356
    • /
    • 2018
  • Commonly, a live-line alarm can be used to measure the electric field strength of a high-voltage system to calculate its current, but it is hard to detect the electric field of shielded cables or concealed structures, such as underground distribution cables. Current sensors can detect the magnetic field in a single core wire, but they cannot determine the magnetic field about a double-core wire because the currents flow in opposite directions. Therefore, it is very difficult to detect certain current problems, such as a fault current in an extension line comprised of a double line. In this paper, to ultimately develop a sensor that can detect the current regardless of line conditions, we used a simulation to determine the concentration of the magnetic field dependent on the distribution of the external magnetic field and the path of each line's core.

Investigations on the Induced Magnetic Fields in High Speed Train due to the Current in the High Speed Railroad Catenary Wire (고속철도의 가선전류에 의한 고속열차내의 자기장 유도에 대한 연구)

  • Han, In-Su;Lee, Tae-Hyung;Park, Choon-Soo;Kim, Ki-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.36-40
    • /
    • 2010
  • In recent society, the electricity is so essential for the human lives. Lots of modern people take many cultural benefits owing to the development of the power systems, the cell phone, the electrical appliances, and etc. However, the problems related to the electromagnetic field generate as the side effects. Examples are the fault in the electric machinery due to the electromagnetic coupling, the fault in the communication devices due to the electromagnetic field around the power line equipments, and the effect upon the human beings due to the electromagnetic field, and etc. In this paper, we induce the vector equation about the magnetic field based on Biot-Savart law. We calculate the magnetic field at the surface of the high speed train with this induced equation and the current in the high speed railroad catenary wire. Finally, we calculate the magnetic field in the high speed train considering the material property like the permeability, the conductivity, and so on.

  • PDF

Numerical analysis of electromagnetic fields in Korean High Speed Train by transmission line matrix method (TLM 방법을 이용한 한국형 고속열차내의 전자계 해석)

  • Han, In-Su;Han, Young-Jae;Lee, Tae-Hyung;Park, Choon-Soo;Kim, Ki-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.466-469
    • /
    • 2008
  • As the industry develops, they are interested in the fault of electric machines and the effect on human beings by electromagnetic fields and waves which generate through much use of electric machines and appliances. In foreign country, they confirmed the standard about electromagnetic interference and compatibility(EMI/EMC) of electromagnetic fields and waves generating electricity transmission/distribution equipments and electric appliance. In Korea, such criteria are applied too. Before EMI/EMC standard is applied, it is important to prepare the plan to predict and reduce electromagnetic fields and waves which generate in the inner and the outer part of electric machinery. To solve such a problem, they calculated Maxwell's equations by finite element method(FEM) and finite difference method(FDM) in most papers. However, these methods have the disadvantage that mathematical expansions are complex and need much memory allocations for grid and mesh generations. In this paper, we introduce transmission line matrix(TLM) method that media of which trains consists are regarded as transmission lines for electromagnetic field calculation in Korean High Speed Train, calculate the electric and magnetic field, and analyze the results.

  • PDF

Effect of AC electric fields on Free Jet Flow in a Laminar (층류 자유제트유동에 인가된 교류전기장의 영향)

  • Kim, Gyeong Taek;Lee, Won June;Cha, Min Suk;Park, Jeong;Chung, Suk Ho;Kwon, Oh Boong;Kim, Min Kuk;Lee, Sang Min;Yun, Jin Han;Keel, Sang In
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.79-81
    • /
    • 2015
  • The experimental study on gasesous laminar free-jet flow was investigated by applying high voltage alternating current (AC) to the nozzle. The jet flows were affedcted significatly by AC electric fields particularly at high voltages for applied frequencies less than 80 Hz, while those were not responded to further increased frequencies. Under certain AC conditions of applied voltgae and frequency, the laminar gaseous fuel stem was broken down at an axial distance and subsequently separtaed into some parts. The velocity fields in jet flows interactiong with applied electric fields were compared with those without having electric field. Interaction of applying electric fields with laminar free jet flow was discussed in detail, and the possible mechanism was also explained.

  • PDF

Parallel Load Techinques Application for Transcranial Magnetic Stimulation

  • Choi, Sun-Seob;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.17 no.1
    • /
    • pp.27-32
    • /
    • 2012
  • Transcranial magnetic stimulation requires an electric field composed of dozens of V/m to achieve stimulation. The stimulation system is composed of a stimulation coil to form the electric field by charging and discharging a capacitor in order to save energy, thus requiring high-pressure kV. In particular, it is charged and discharged in capacitor to discharge through stimulation coil within a short period of time (hundreds of seconds) to generate current of numerous kA. A pulse-type magnetic field is formed, and eddy currents within the human body are triggered to achieve stimulation. Numerous pulse forms must be generated to initiate eddy currents for stimulating nerves. This study achieved high internal pressure, a high number of repetitions, and rapid switching of elements, and it implemented numerous control techniques via introduction of the half-bridge parallel load method. In addition it applied a quick, accurate, high-efficiency charge/discharge method for transcranial magnetic stimulation to substitute an inexpensive, readily available, commercial frequency condenser for a previously used, expensive, high-frequency condenser. Furthermore, the pulse repetition rate was altered to control energy density, and grafts compact, one-chip processor with simulation to stably control circuit motion and conduct research on motion and output characteristics.

Training Needs Analysis for the Roles and Competency of Field Representatives in Electric Work (전기공사 현장대리인의 역할 및 역량에 대한 교육요구분석)

  • Yun, Hyeon Woo;Yoon, Gwan Sik
    • 대한공업교육학회지
    • /
    • v.40 no.1
    • /
    • pp.142-162
    • /
    • 2015
  • The purpose of this study are to provide the basic data materials and implementations for successful performance of electric-work field representatives of South Korean firms by identifying their roles and competency and examining their educational need. For this research purposes, three phased analysis was followed on: (1) the roles of electric-work field representatives, (2) competency of electric-work field representatives and (3) educational need for their competency. This research method was to conduct a focus group interview for 10 expert field representatives along with survey. The collected data materials were processed by MS Excel and SPSS 21.0 for statistical analysis including average, standard deviation and other basic statistics; the gap in awareness of field representatives; and need values. For the needs analysis, the difference between significance of field representatives' competency and current status was examined by t test. And the awareness gap between competency importance and current status was identified based on the Borich equation. The Locus for Focus model was employed herein to identify the kinds of competency with high importance and high inconsistency to prioritize. As a result, this research has found as follows: first, the roles of field representatives were found to be in 13 different kinds of roles. Second, electric-work field representatives were found to need to have 16 different skills. Third, regarding the 16 abilities, the gap between current status and significance was analyzed herein. The results showed statistically significant differences in all cases. The Borich needs analysis found the first required ability was communication ability followed by power of execution, conflict management ability, analytical thinking and time management ability. Also, the results of Locus for Focus model analysis displayed that the first quadrant(HH) included 7 highly-demanded abilities of communication ability, analytical thinking, decision making ability, specialty, time management ability, power of execution and drive for work implementation. The top-priority group was found to have 5 items of communication ability, analytical thinking, time management ability, power of execution and drive for work implementation which were commonly seen in the Locus for Focus model outcomes. Based on these findings, this research could identify the roles and competency of electric-work field representatives and provide the basic data materials applicable to future personal management of electricity companies including recruitment, division of work, job description, evaluation, etc. Also this research offered guidelines on demanded abilities in the field and where to place priority. The kinds of abilities with high educational demand as found in this research must be considered in designing educational programs for the competency building of field representatives. This research is expected to provide useful information in developing such educational programs for field representatives.