• 제목/요약/키워드: high electric field

검색결과 1,502건 처리시간 0.033초

Comparative Analysis of the PWM of an Inverter for an Electric Aircraft Thrust Motor

  • Koo, Bon-soo;Jo, Seong-hyeon;Choi, In-ho
    • 항공우주시스템공학회지
    • /
    • 제15권4호
    • /
    • pp.21-29
    • /
    • 2021
  • As global environmental regulations have been strengthened, the eco-friendly market has grown rapidly. In the field of aircraft, research on electric vertical take-off and landing aircraft that can enter city centers and perform personal air transportation using electric propulsion is ongoing. For aircraft using electric propulsion methods to operate reliably, electric power thrust systems are a key factor. Electric aircraft require a high power density for propulsion systems with strict limits on volume and weight. The efficient control of inverter systems is essential for achieving high power density. Therefore, in this paper, the characteristics of inverters and motors were analyzed through simulations based on the space vector pulse width modulation (PWM) and discontinuous PWM methods for controlling inverter systems.

Trapped Field Analysis of a High Temperature Superconducting Bulk with Artificial Holes

  • Jang, Guneik;Lee, Man-Soo;Han, Seung-Yong;Kim, Chan-Joong;Han, Young-Hee;Park, Byung-Joon
    • Journal of Magnetics
    • /
    • 제16권2호
    • /
    • pp.181-185
    • /
    • 2011
  • To improve trapped field characteristics of a high temperature superconducting (HTS) bulk, a technique to implement artificial holes has been studied. The artificial holes, filled up with epoxy or metal, may provide better cooling channel and enhance mechanical strength of the HTS bulk. Although many useful researches based on experiments have been reported, a numerical approach is still limited because of several reasons that include: 1) highly non-linear electromagnetic properties of HTS; and 2) difficulty in modeling of randomly scattered "small" artificial holes. In this paper, a 2-D finite element method with iteration is adopted to analyze trapped field characteristics of HTS bulk with artificial holes. The validity of the calculation is verified by comparison between measurement and calculation of a trapped field in a $40{\times}40\;mm$ square and 3.1 mm thick HTS bulk having 16 artificial holes with diameter of 0.7 mm. The effects of sizes and array patterns of artificial holes on distribution of trapped field within HTS bulk are numerically investigated using suggested method.

프린지 필드에 의해 구동되는 수직 배향된 광학적 자기 보상 스플레이 액정 소자 (Liquid Crystal Device Associated with Fringe-field Driven Vertically Aligned Optically Compensated Splay (OCS))

  • 정병선;김승재;오상민;김향율;이승희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 디스플레이 광소자분야
    • /
    • pp.157-160
    • /
    • 2004
  • We have studied an optically compensated splay (OCS) mode driven by fringe electric field. The OCS LC configuration obtained by applying voltage to vertically aligned LCs shows a dark state when an optic axis of the OCS cell coincides with one of crossed polarizer axis. When the fringe electric field is applied, the LC director rotates in plane above whole electrode surface, giving rise to high transmittance and wide viewing angle simultaneously.

  • PDF

The Field of Power/Ground Planes influenced by the HPEM Source, and its Damage Reduction

  • Kahng, Sung-Tek;Kim, Hyeong-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권3호
    • /
    • pp.406-410
    • /
    • 2012
  • This paper looks into the field inside the wide rectangular box structure that is excited by the High Power Electromagnetic(HPEM) source as a potential threat to electric grid and communication networks causing malfunction or destruction. The rectangular box is assumed power/ground planes and its internal field is calculated by the cavity model with the lightning strike excitation as an HPEM pulse. The accuracy of the calculation method employed here is validated through a $156mm{\times}106mm{\times}508{\mu}m$ parallel metallic plate case which is manufactured and tested, and is applied to the size of a building. With the help of the cavity model that takes into account loading, the level of the electric field is shown to decrease when a metal pillar is loaded between the power and ground planes.

근조직 재활치료를 위한 자기신경 시스템의 설계 및 제작에 관한 연구 (Research about design and manufacture of own nerve system for core formation rehalititation treatment)

  • 김휘영;최진영;박성준;김진영;박성준;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2171-2172
    • /
    • 2006
  • Magnetic nerve stimulation treatment is much backward real condition than other field. Specially, successful medical treatment introduction of magnetic field (MF) can was refered long ago in Avicenna's work, and is thought as age of medicine magnetology development recently. These development is achieved through biologist and biophysicist and clinician's joint effort, but, new mountings and relationship air tassel are developed steadily. Magnetic nerve stimulation treatment field designs treatment system by each function during long wave high-amplitude (traditional magneto therapy of greatly great that strong that) short time that CMF, VMF, PMF field etc. are representative but are HPMT technology in this research and manufacture and special quality did comparative analysis.

  • PDF

Domain Contribution in the Electric-field-induced Strain of PZT Ceramics

  • Tsurumi, Takaaki
    • The Korean Journal of Ceramics
    • /
    • 제7권1호
    • /
    • pp.30-35
    • /
    • 2001
  • The contribution of the non-$180^{\circ}C$ domains to the electric-field-induced strains (EFI-strains) of PZT ceramics was evaluated by an XRD method and by an interferometric method. The XRD intensity ratio of 200 and 002 diffraction peaks of tetragonal PZT was measured under strong electric fields. The amount of the $90^{\circ}$ domain reorientation was evaluated and the strain due to the domain reorientation was calculated. It was confirmed that the EFI-strain of PZT ceramics was equal to the sum of the strain calculated from the d$_33$ constant determined by the resonance-antiresonance method and the strain due to the $90^{\circ}$ domain reorientation. The amount of the $90^{\circ}$domain reorientation has a linear relation with the c/a ratio in the "soft" PZT ceramics. A Mech-Zehnder interferometer was constructed to measure the EFI-strains vs. electric-field curves of PZT ceramics as a function of frequency. The EFI-strain vs. electric-field curve showed a hysteresis due to the effect of the non-$180^{\circ}$ domain reorientation when the applied voltage was high and its frequency was low. The apparent piezoelectric constant increased from the d$_33$ value determined by the resonance-antiresonance method with decreasing frequency. This deviation was attributed to the non-$180^{\circ}$ domain contribution.tribution.

  • PDF

전력케이블용 저밀도폴리에틸렌박막의 전기전도특성 (Electric conduction properties of low density Polyethylene film for Power cable)

  • 황종국;홍능표;이용우;소병문;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 추계학술대회 논문집
    • /
    • pp.143-146
    • /
    • 1994
  • In older to investigate the properties of electric conduction in low density polyethylene(LDPE) for power cable, the thickness of specimen was the 30, 100($\mu\textrm{m}$) of LDPE. The experimental condition for conductive properties was measured until the breakdown occurs at temperature ranges from 30 to 110[$^{\circ}C$] and in the electric field of 1 to 5 ${\times}$10$^2$[Mv/m]. As for increase of temperature, the current density of LDPE was increased with constant ratio in low field, but changes with exponential function in high field. The tunnel current of pre-breakdown region is shifted toward low field as much as thermal excitation energy.

과전류 계측을 위한 광자계센서의 구현 (Implementation of Optical Magnetic Field Sensor for Measurement of Over Current)

  • 박해수;노종대;김요희;박병석;안성준;조홍근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1871-1873
    • /
    • 1997
  • The conventional current transformers are often take faults and out of order that for detect to over current of electric power lines because electromagnetic interference. But, it is possible to implement protection relay of high reliability using optical magnetic field sensor which are immunity and small size. The optical magnetic field sensor is possible to rapidly detect to over current and recover when electric power line have fault. And it is not necessary to make with capacitance of electric power lines as optical magnetic field sensor is have linearity from 0 to about 20kA. In this study, we designed and constructed compensative feedback circuit in order to minimize of optical power intensity variation with environ- mental variations(temperature, drive current) of light source. And this system have highest optical advantages and reliability.

  • PDF

정전형여과집진방식에서 여과특성에 관한 연구 (A Study on Filtration Performance Test with Electrostatically Enhanced Fabric Filter)

  • 천중국;박출재;최금찬
    • 한국대기환경학회지
    • /
    • 제11권4호
    • /
    • pp.361-367
    • /
    • 1995
  • This study has been carried out to investigate the filteration performance of Electrostatically Stimulated Fabric Filter(ESFF) at high temperature condition. The electric field was maintained parallel to the fabric surface. The benefits of ESFF are lower residual pressure drop, improvement of fine particle removal efficiency and increasing reduced rate of pressure drop during a filteration cycle, stable operation at higher filtering velocities. According to the variance of filtering velocities and dust loadings, the results are summarized as follows; By imposing an electric field on the filter, the reduced rate of pressure drop was 7.sim.18% at room temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Under the electric field around the filter, the reduced rate of pressure drop was 10.sim.35% at high temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Most of all, at high temperature, the value of reduced rate of pressure drop was resulted to 25%. Also the collecting efficiency was shown clearly improved. By the SEM photo analysis, the number of penetrated particles at the Conventional Fabric Filter was approximately two times that of Electrostatically Stimulated Fabric Filter.

  • PDF