• 제목/요약/키워드: high compression

검색결과 2,726건 처리시간 0.027초

고속철도 터널내를 전파하는 압축파의 일차원 수치해석 (One-Dimensional Numerical Study of Compression Wave Propagating in High-Speed Railway Tunnel)

  • 김희동;엄용균;송미일태
    • 대한기계학회논문집
    • /
    • 제19권5호
    • /
    • pp.1280-1290
    • /
    • 1995
  • In order to investigate the compression wave propagating in a high-speed railway tunnel, a numerical calculation was applied to the wave phenomenon occurring in a model tunnel. Unsteady, one-dimensional inviscid or viscous flows were solved by an explicit TVD scheme, and the calculated flows were compared with the results of measurement in real tunnels. Tunnel noises caused by emission of the compression wave were characterized in terms of excess pressure of compression wave, pressure gradient in the wave front and width of the compression wave. Calculated attenuation, pressure gradient and width of compression wave with the propagating distance agreed with the results of measurement in the real tunnels. The results also show that tunnel noises are proportional to the train velocity entering the tunnel.

고속철도 터널입구에서 형성되는 압축파의 특성에 관한 연구 (Characteristics of High-Speed Railway Tunnel Entry Compression Wave)

  • 김희동;김태호;이종수;김동현
    • 대한기계학회논문집B
    • /
    • 제23권2호
    • /
    • pp.234-242
    • /
    • 1999
  • Flow phenomena such as the pressure transients Inside a high-speed railway tunnel and the Impulsive waves at the exit of the tunnel are closely associated with the characteristics of the entry compression wave, which is generated by a train entering the tunnel. Tunnel entrance hood may be an effective means for alleviating the Impulsive waves and pressure transients. The objective of the current work is to explore the effects of the train nose shape and the entrance hood on the characteristics of the entry compression wave. Numerical calculations using the method of characteristics were applied to one-dimensional, unsteady, compressible flow field with respect to high-speed railway/tunnel systems. Two types of the entrance hoods and various train nose shapes were employed to reveal their influences on the entry compression wave for a wide range of train speeds. The results showed that the entry compression wave length increases as the train nose becomes longer and the train speed becomes lower. The entry compression wave length in the tunnel with hood becomes longer than that of no hood. Maximum pressure gradient in the compression wavefront reduces by the entrance hood. The results of the current work provide useful data for the design of tunnel entrance hood.

Compression Properties of Weft Knitted Fabrics Consisting of Shrinkable and Non-Shrinkable Acrylic Fibers

  • Bakhtiari M.;Najar S. Shaikhzadeh;Etrati S. M.;Toosi Z. Khorram
    • Fibers and Polymers
    • /
    • 제7권3호
    • /
    • pp.295-304
    • /
    • 2006
  • High-bulk worsted yams with different shrinkable and non-shrinkable acrylic fibers blend ratios are produced and then single jersey weft knitted fabrics with three different structures and loop lengths are constructed. The physical properties of produced yams and compression properties of produced fabrics at eight pressure values (50, 100, 200, 500, 1000, 1500 and $2000 g/cm^2$) were measured using a conventional fabric thickness tester. Then, weft-knitted fabric compression behavior was analyzed using a two parameters model. It is found that at 40 % shrinkable fibre blending ratio the maximum yam bulk, shrinkage, abrasion resistance and minimum yarn strength are obtained. It is also shown that high-bulk acrylic yarn has the highest elongation at 20 % shrinkable fibre blend ratio. The statistical regression analysis revealed that the compression behavior of acrylic weft-knitted fabrics is highly closed to two parameter model proposed for woven fabrics. It is also shown that for weft-knitted structure, there is an incompressible layer (V') which resists against high compression load. Acrylic weft-knitted fabrics with knit-tuck structure exhibit higher compression rigidity and lower softness than the plain and knit-miss structures. In addition, at 20 % shrinkable fibre blend ratio, the high-bulk acrylic weft-knitted fabrics are highly compressible.

Tests and finite element analysis on the local buckling of 420 MPa steel equal angle columns under axial compression

  • Shi, G.;Liu, Z.;Ban, H.Y.;Zhang, Y.;Shi, Y.J.;Wang, Y.Q.
    • Steel and Composite Structures
    • /
    • 제12권1호
    • /
    • pp.31-51
    • /
    • 2012
  • Local buckling can be ignored for hot-rolled ordinary strength steel equal angle compression members, because the width-to-thickness ratios of the leg don't exceed the limit value. With the development of steel structures, Q420 high strength steel angles with the nominal yield strength of 420 MPa have begun to be widely used in China. Because of the high strength, the limit value of the width-to-thickness ratio becomes smaller than that of ordinary steel strength, which causes that the width-to-thickness ratios of some hot-rolled steel angle sections exceed the limit value. Consequently, local buckling must be considered for 420 MPa steel equal angles under axial compression. The existing research on the local buckling of high strength steel members under axial compression is briefly summarized, and it shows that there is lack of study on the local buckling of high strength steel equal angles under axial compression. Aiming at the local buckling of high strength steel angles, this paper conducts an axial compression experiment of 420MPa high strength steel equal angles, including 15 stub columns. The test results are compared with the corresponding design methods in ANSI/AISC 360-05 and Eurocode 3. Then a finite element model is developed to analyze the local buckling behavior of high strength steel equal angles under axial compression, and validated by the test results. Following the validation, a finite element parametric study is conducted to study the influences of a range of parameters, and the analysis results are compared with the design strengths by ANSI/AISC 360-05 and Eurocode 3.

Medical Image Compression using Adaptive Subband Threshold

  • Vidhya, K
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.499-507
    • /
    • 2016
  • Medical imaging techniques such as Magnetic Resonance Imaging (MRI), Computed Tomography (CT) and Ultrasound (US) produce a large amount of digital medical images. Hence, compression of digital images becomes essential and is very much desired in medical applications to solve both storage and transmission problems. But at the same time, an efficient image compression scheme that reduces the size of medical images without sacrificing diagnostic information is required. This paper proposes a novel threshold-based medical image compression algorithm to reduce the size of the medical image without degradation in the diagnostic information. This algorithm discusses a novel type of thresholding to maximize Compression Ratio (CR) without sacrificing diagnostic information. The compression algorithm is designed to get image with high optimum compression efficiency and also with high fidelity, especially for Peak Signal to Noise Ratio (PSNR) greater than or equal to 36 dB. This value of PSNR is chosen because it has been suggested by previous researchers that medical images, if have PSNR from 30 dB to 50 dB, will retain diagnostic information. The compression algorithm utilizes one-level wavelet decomposition with threshold-based coefficient selection.

급축소관을 전파하는 압축파에 관한 실험적 연구 (Experimental study on compression wave propagating in a sudden reduction duct)

  • 김희동
    • 대한기계학회논문집B
    • /
    • 제21권9호
    • /
    • pp.1139-1148
    • /
    • 1997
  • Compression waves propagating in a high-speed railway tunnel develops large pressure fluctuations on the train body or tunnel structures. The pressure fluctuations would cause an ear discomfort for the passengers and increase the aerodynamic resistance of trains. As a fundamental research to resolve the pressure wave phenomenon in the tunnel, experiments were carried out by using a shock tube with an open end. A blockage to model trains inside the tunnel was installed on the lower wall of shock tube, thus forming a sudden cross-sectional area reduction. The compression waves were obtained by the fast opening gate valve instead of a conventional diaphragm of shock tube and measured by the flush mounted pressure transducers with a high sensitivity. The experimental results were compared with the previous theoretical analyses. The results show that the ratio of the reflected to the incident compression wave at the sudden cross-sectional area reduction increases but the ratio of the passing to the incident compression wave decreases, as the incident compression wave becomes stronger. This experimental results are in good agreements with the previous theoretical ones. The maximum pressure gradient of the compression wave abruptly increases but the width of the wave front does not vary, as it passes over the sudden cross-sectional area reduction.

디젤기관에 대한 앳킨슨사이클 구성과 사이클의 열역학적 해석에 관한 연구 (A Study on the Composition of Atkinson Cycle and Thermodynamically Analysis for a Diesel Engine)

  • 김철수;정영관;장태익
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권2호
    • /
    • pp.185-193
    • /
    • 2005
  • The present study composed a diesel-atkinson cycle of high expansion as a method of achieving high efficiency in diesel cycle engines. It also interpreted the cycle engine thermodynamically analysis to determine the possibility of the improvement of thermal efficiency and clarified the characteristics of several factors . According to the result of theoretical analysis, heat efficiency was highest when expansion-compression ratio Reど:1. In addition. diesel engines with high apparent compression ratio had higher expansion-compression ratio than otto engines and consequently their effect of high expansion was high. which in turn enhanced thermal efficiency. When the atkinson cycle was implemented in a real diesel engine by applying the miller cycle through the variation of the closing time of the intake valve, the effective compression ratio and the quantify of intake air decreased and as a result, the effect of high expansion was not observed. Accordingly. the atkinson cycle can be implemented when the quantity of intake air is compensated by supercharge and the effective compression ratio is maintained at its initial level through the reduction of the clearance volume. In this case. heat efficiency increased by $4.1\%$ at the same expansion-compression ratio when the apparent compression ratio was 20 and the fuel cut off ratio was 2. As explained above, when the atkinson cycle was used for diesel cycle. heat efficiency was improved. In order to realize high expansion through retarding the intake value closing time, the engine needs to be equipped with variable valve timing equipment, variable compression ratio equipment and supercharged Pressure equipment. Then a diesel-atkinson cycle engine is realized.

CCSDS 122.0-B-1 : 고해상도위성의 영상압축 기술 (CCSDS 122.0-B-1 : An Image Compression Technology for High Resolution Satellites)

  • 서석배;구인회
    • 항공우주산업기술동향
    • /
    • 제6권2호
    • /
    • pp.90-98
    • /
    • 2008
  • 최근 고해상도위성의 개발 및 활용이 활발해지면서, 데이터 전송 및 처리를 위한 영상압축의 중요성이 대두되고 있다. 이에 발맞추어 CCSDS (Consultative Committee for Space Data Systems)에서는 고해상도위성의 영상압축권 고안인 CCSDS 122.0-B-1을 2005년 말에 발표했으며, 이는 향후 고해상도 위성의 영상압축에 널리 적용될 것으로 기대된다. 본 논문에서는 고해상도위성의 최근 동향을 알아보고, CCSDS 122.0-B-1 기반의 고해상도위성 영상압축 기술에 대해 설명하며, JPEG과 성능을 비교한 결과를 기술한다.

  • PDF

냉시동시 압축착화 조건의 상관관계에 관한 수소 HCCI 기관의 실험적 연구 (An Experimental Study on Correlation of Compression Ignition Condition at Cold Start with Hydrogen HCCI Engine)

  • 이광주;이종구;안병호;이종태
    • 한국수소및신에너지학회논문집
    • /
    • 제23권6호
    • /
    • pp.628-633
    • /
    • 2012
  • It was found that the pure hydrogen-air pre-mixture was self-ignited at a high compression ratio without any assisting method in room temperature, thus refuting the preconception that compression ignition of hydrogen engine was impossible. Therefore, in order to analyze the correlation of compression ignition condition at cold start with hydrogen HCCI engine clearly, the possibility of compression igniting compression ratio is investigated with the change of equivalence ratio and engine speed, experimentally. As the results, it is confirmed that the possibility of compression-igniting compression ratio at cold start was decreased by increasing equivalence ratio due to decreasing auto-ignition temperature. In addition, it is grasped that the possibility of compression-igniting compression ratio at cold start is decreased around 14.9% by increasing engine speed at same supply energy.

TTS DB 압축을 위한 광대역 파형보간 부호기 구현 (Implementation of Wideband Waveform Interpolation Coder for TTS DB Compression)

  • 양희식;한민수
    • 대한음성학회지:말소리
    • /
    • 제55권
    • /
    • pp.143-158
    • /
    • 2005
  • The adequate compression algorithm is essential to achieve high quality embedded TTS system. in this paper, we Propose waveform interpolation coder for TTS corpus compression after many speech coder investigation. Unlike speech coders in communication system, compression rate and anality are more important factors in TTS DB compression than other performance criteria. Thus we select waveform interpolation algorithm because it provides good speech quality under high compression rate at the cost of complexity. The implemented coder has bit rate 6kbps with quality degradation 0.47. The performance indicates that the waveform interpolation is adequate for TTS DB compression with some further study.

  • PDF