• 제목/요약/키워드: high chloride management of groundwater

검색결과 7건 처리시간 0.019초

밀양시 지하수 수질 특성과 DRASTIC 지수를 이용한 지하수 오염취약성 평가 (Evaluation of Vulnerability to Groundwater Contamination using Groundwater Quality Characteristics and DRASTIC Index in Miryang City)

  • 정성연;김시은;윤설민;오제헌;이충모
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제29권3호
    • /
    • pp.23-36
    • /
    • 2024
  • Miryang City, the study area, has a water supply rate of 87.4%, which is 12% lower than the national water supply rate of 99.4%, but has a high dependence on groundwater due to the high ratio of farms. In agricultural areas, contamination becomes relatively more critical, requiring significant attention to the management and conservation of groundwater resources. This study aims at estimate groundwater vulnerability of Miryang City using the DRASTIC index map, Piper diagram, and water quality data to correlated with the DRASTIC index. The results from DRASTIC map were divided into five classes: very high, high, moderate, low, and very low. The areas in central and southern part of study area, which are characterize by a very high index with [Ca-Cl] and [Na-Cl] water types, covering a large alluvium with the Miryang River and Nakdonggang River. In addition, a correlation analysis between groundwater quality parameters and the DRASTIC index was carried out. Chloride, sodium, and sulfate ions showed a weak relationship with DRASTIC index, with correlation coefficient was 0.507, 0.487 and 0.344, respectively. These results suggest that aquifer media, soil media, hydraulic conductivity, and chloride ion are important factors for groundwater vulnerability.

Factors controlling groundwater chemistry of the Triassic Sandstone aquifer in North Yorkshire UK

  • Yoshida K.;Bottrell S.H.;West L.J.
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.29-38
    • /
    • 2005
  • It is important to understand groundwater conditions such as recharge, flow and hydrochemical process occurred within an aquifer for groundwater protection and groundwater resource management. Groundwater from the Triassic Sherwood Sandstone aquifer of North Yorkshire has been used for industrial purposes and domestic water supply. Tn order to understand the processes affecting groundwater chemistry and identify the sources of high chloride, sulphate and nitrate concentrations hydrochemical and isotopic measurements were carried out. Hydrochemical and isotopic measurements indicated that five groundwater types exist within the Sherwood Sandstone aquifer of study area. The results of hydrochemical and isotopic measurements showed that older groundwaters have different hydrochemical and isotopic characteristics from recent recharge water. It was also found that water-rock interactions are the dominant mechanism controlling the ${\delta}^{13}C$ composition of dissolved inorganic carbon, the ${\delta}^{34}S\;and\;{\delta}^{18}O$ composition of dissolved sulphate and the strontium isotope ratios ($^{87}Sr/^{86}Sr$) in recent recharge water and old groundwater. Several abstraction boreholes within the Selby wellfield have been contaminated by saline water. The isotopic data of saline groundwater samples taken from these abstraction boreholes indicate that saline waters are derived from the dissolution of the Triassic evaporites within the Mercia Mudstone.

  • PDF

제주도 해안지역 고염분 현상에 대한 고찰 (The study of high chloride in the coastal area of Cheju island)

  • 한규언;신희섭
    • 지질공학
    • /
    • 제10권2호
    • /
    • pp.150-171
    • /
    • 2000
  • 제주도 해안지방에서 고염분 지하수가 산출되고 있다. 이 지역의 지질 구조에 의한 저지하수위 형성이 주 요인으로 보이며 부분적으로는 관정에서 과다양수 등의 사유가 문제가 된다. 본 연구에서는 고염분을 가진 관정의 분포를 알아내고, 16개의 전기전도도를 검층하였다. 동부지역에서 다른 지역에 비해 염소이온이 높게 나왔다. 관정저의 표고가 해수로 나누어 수질성분 분석자료를 비교하였다. 이외에 전기전도도를 검충하였다. 동부지역에서 다른 지역에 비해 염소이온이 높게 나왔다. 관정저의 표고가 해수면 기준 0m이상, 0m∼-10m, -10∼-20m, -20m∼-30m, -30m∼-40m, -40m 이하의 6개의 군으로 나누어 수질성분 분석자료를 비교하였다. 이외에 전기전도도 검층 등 다른 조사자료를 수집하여 염소이온과 관계를 파악하고, 염소이온도 분포도를 작성하였다. 북제주군 한림읍 지역에서 염수를 막은 2개의 사례는 염수 침입이 이루어지는 대수층을 그라우팅으로 붕쇄하여, 염수의 침입현상을 방지하는 공법이다.

  • PDF

도계지역 오십천에서의 지하수 영향분석 - 수리지화학적 특성과 기원 (Influence of Groundwater on the Hydrogeochemistry and the Origin of Oseepchun in Dogye Area, Korea)

  • 황정환;송민호;조해리;우남칠
    • 자원환경지질
    • /
    • 제49권3호
    • /
    • pp.167-179
    • /
    • 2016
  • 이 연구에서는 강원도 도계지역의 오십천과 주변의 지류를 대상으로 하천수의 수리지화학적 특성을 규명하여 지표 수질에 대한 지하수의 영향을 정량적으로 밝히고, 이를 근거로 체계적인 수자원 관리를 위한 기본정보를 제공하고자 하였다. 오십천 하천수의 수질모니터링 결과, 산화환원전위, 용존 이온성분의 분포와 성분간의 상관성, 산소-수소 동위원소비, 오염물질의 분포와 발생 등은 오십천의 가장 중요한 공급원이 지하수임을 지시한다. 하천수의 수질유형은 기반암의 지질학적 특성에 따른 지하수의 물-암석 반응에 의해 결정되며, 조선누층군의 탄산염 기반암에 기원하는 $Ca-HCO_3$ 유형, 평안누층군 내 탄층에 수반되는 황화광물의 용해와 연관된 (Ca, Mg)-$SO_4$ 유형, 그리고 이 두 유형이 복합적으로 나타나는 (Ca, Mg)-($HCO_3$, $SO_4$) 유형 등의 3가지 유형이 나타난다. 수질 오염현상은 광산배수와 유사한 높은 $SO_4$ 함량과, 지표 토지이용에 따른 질산염의 국지적 발생이 확인된다. 여름철 집중강수는 하천수질의 전반적인 유형에는 영향을 미치지 않으나, 지표기원의 오염물질인 질산염과 염소 등의 유입이 증가되는 현상을 초래한다. 그럼에도 불구하고, 증가된 하천유출량으로 인해 용존이온의 농도 희석효과가 발생한다. 본 연구결과는 지표수 수질관리의 시발점이 주 공급원이 되는 지하수질의 특성화로부터 시작되어야 함을 지시한다.

토양세척법에 의한 클레이사격장 납 오염토양의 정화에 관한 연구 (A Study on the Remediation of Lead Contaminated Soil in a Clay Shooting Range with Soil Washing)

  • 이인화;설명수
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제15권5호
    • /
    • pp.23-31
    • /
    • 2010
  • For an efficient remediation of Pb-contaminated soil (S-1) in a clay shooting range, a soil washing test was performed with mineral acid, organic acid, chelating agent, and chloride. The Pb extraction efficiency of extractant (0.1 M) used in the washing test showed the order of HCl > $Na_2$-EDTA > NTA > DTPA > citric acid > malic acid > succinic acid > acetic acid > $CaCl_2$ > $MgCl_2$, for S-1 soil. As compared to initial Pb concentration, extraction efficiency by the concentration of extractant was 93.35%, 80.80%, 73.92%, and 24.57% in S-1 soil for HCl (0.5 M, pH 1.10), $Na_2$-EDTA (0.01 M, pH 3.99), citric acid (0.5 M, pH 1.27), and $MgCl_2$ (0.1 M, pH 8.82), respectively. S-1 soil had 56.83% of residue form and 43.17% of non-residue form (18.04% of exchangeable form), respectively. Although the concentrations of these fractions sharply decreased after HCl washing, since the exchangeable forms with relatively large mobility are still distributed as high as 18.78% (to Pb total content in residual soils) in S-1 soil, it is necessary to devise a proper management plan for residual soils after soil washing application.

동해안 화진포 석호 주변 대수층 내 담수-염수 경계면 분석에 관한 연구 (A Study on Analysis of Freshwater-saltwater Interface in the Aquifer around Hwajinpo Lagoon on the Eastern Coast of Korea)

  • 김민지;김동진;전성천;이정훈
    • 자원환경지질
    • /
    • 제54권6호
    • /
    • pp.699-707
    • /
    • 2021
  • 동해안에 위치한 화진포 석호는 담수와 염수가 혼합되는 환경으로 생물 다양성이 풍부하여 높은 보존 가치를 지니고 있어 체계적인 관리가 필요하다. 석호의 현재 환경에 대한 분석을 위해 호소수에 영향이 큰 주변 대수층의 지하수 수위 분포와 지하수 흐름의 특성을 파악하였다. 또한 호소수의 염분도가 유지되는 기작으로 추정되는 대수층으로의 해수침투의 영향을 파악하기 위해 수리지구 화학적 변동을 분석하였다. 연구 결과 사주지역의 대수층에 쐐기형태의 담수-염수 경계면이 분포하며, 강우가 적은 기간이 지속되고 온도가 높아 석호의 증발이 일어날 경우 담수-염수 경계면이 상승하여 지하수를 통한 해수의 유입 가능성이 높은 것으로 판단된다. 수리지구 화학적 특성으로는 이온델타(혼합된 지하수의 이론적인 화학조성과 실제 시료가 가지는 값과의 차이) 값을 산출하여 해수 침투에 따른 대수층 내에서 양이온 교환반응 및 침전 반응이 일어난 것으로 추정하였다. 각 지점별로 해수가 혼합된 비율을 계산하기 위해서 산소동위원소와 염소이온을 추적자로 사용하였으며 혼합비의 평균값은 0.3, 최대값은 0.87을 나타내었다. 전체적인 혼합비 결과는 해안에서의 거리에 따라 분포하는 것으로 판단되나, 이론적인 예상과는 상이한 결과가 일부 존재하는데 그 부근의 대수층 특성이 반영된 것으로 판단된다. 더욱 구체적인 분석을 위해서는 계절적인 변화와 해수침투 기작을 모사하는 등 추가적인 연구가 필요할 것으로 판단된다.

석탄 바닥재 메움재 재활용을 위한 Field Test Cells로부터 오염물질 배출 특성 및 잠재적 영향 평가 (Leaching Characteristics and Potential Impact Assessment of Pollutants from Field Test Cells with Coal Bottom Ash as Fill Materials for Recycling)

  • 장용철;이성우;강희석;이승훈
    • 환경영향평가
    • /
    • 제22권2호
    • /
    • pp.135-145
    • /
    • 2013
  • The recycling of coal bottom ash generated from coal power plants in Korea has been limited due to heterogenous characteristics of the materials. The most common management option for the ash is disposal in landfills (i.e. ash pond) near ocean. The presence of large coarse and fine materials in the ash has prompted the desire to beneficially use it in an application such as fill materials. Prior to reuse application as fill materials, the potential risks to the environment must be assessed with regard to the impacts. In this study, a total of nine test cells with bottom ash samples collected from pretreated bottom ash piles and coal ash pond in a coal-fired power plant were constructed and operated under the field conditions to evaluate the leachability over a period of 210 days. Leachate samples from the test cells were analyzed for a number of chemical parameters (e.g., pH, salinity, electrical conductance, anions, and metals). The concentrations of chemicals detected in the leachate were compared to appropriate standards (drinking water standard) with dilution attenuation factor, if possible, to assess potential leaching risks to the surrounding area. Based on the leachate analysis, most of the samples showed slightly high pH values for the coal ash contained test cells, and contained several ions such as sodium, potassium, calcium, magnesium, chloride, sulfate, and nitrate in relatively large quantities. Three elements (aluminum, boron, and barium) were commonly detected above their respective detection limits in a number of leachate samples, especially in the early leaching period of time. The results of the test cell study indicate that the pollutants in the leachate from the coal ash test cells were not of a major concern in terms of leaching risk to surface water and groundwater under field conditions as fill materials. However, care must be taken in extending these results to actual applications because the results presented in this study are based on the limited field test settings and time frame. Structural characteristics and analysis for coal bottom ash may be warranted to apply the materials to actual field conditions.