• 제목/요약/키워드: high building

검색결과 6,817건 처리시간 0.031초

친환경건축물 인증제도 평가를 통한 고층 주거용 건물의 환경성능 분석 (A Study on the Analysis of Environment Performances in High-Rise Residential Building Through Green Building Certification System)

  • 채문병;차민철;제성호;석호태
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.281-286
    • /
    • 2006
  • In case of Korea, immovable property like location, land prise or investment value is more highly estimated than quality of life of residents for performance and value of apartment house, because of limited land area or high density of population. But the high level of life has recently caused the increasing demand in better life. As there is no cases to provide the house in bulk due to the housing market condition, it is necessary to evaluate performance and value of structure, disaster prevention safety, habitability, antiquated condition of building and equipment, maintenance condition and so on that has importantly influence on resident's life quality. So, this study aims to understand the actual condition of environmental performance for the present apartment by comparing the designated apartment, which is ready to have completed in Daegu, with the mixed use residential building, which gained the best grade for green building certification system. Also by analyzing and evaluating a right to enjoy sunshine, floor impact noise etc. and indoor air quality.

  • PDF

공동주택의 라이프사이클을 통한 지속가능성과 친환경성 평가기법에 관한 연구 (Evaluation of Sustainable and Environmentally Friendly Building through the Life-cycle of Apartment Buildings)

  • 김삼열;김세환;이성
    • KIEAE Journal
    • /
    • 제1권1호
    • /
    • pp.11-16
    • /
    • 2001
  • Concern about global environment has been increasing in recent years. Efforts to minimize the environmental impact to the globe as well as human beings have increased, especially in the late twentieth century. The study researches one of the solutions for the environmentally friendly building construction, which can contribute to sustaining the world environment. Assessment and proposals are made for high-rise apartments, one of the most popular construction types nowadays in Korea. Careful building design and construction for apartment buildings could reduce the environmental impact significantly without lowering standards of living. Since the volume of high-rise apartment construction is so great, a small improvement in each building will make a great contribution. Assessments are made over the life-span of apartment buildings. A tool has been made through references from western examples. mainly from BHEEAMs made in the United Kingdom. The components of the tool include passive design strategies, building materials. energy consumption during building operation, and management and maintenance. Co-relationship between buildings and ten environment in Korea is searched. Korean high-rise apartments are assessed with the tool and suggestions for sustainable development are made mainly for improvement of embodied energy of building materials and the life of buildings.

  • PDF

Study on the Waterproofing Performance of FGD Gypsum Building Products from Inorganic-Organic Composite Additives

  • Ding, Yi;Fang, Youchun;Ren, Qifang;Fang, Hui;Zhang, Qicai;Oh, Won-Chun
    • 한국재료학회지
    • /
    • 제25권11호
    • /
    • pp.590-597
    • /
    • 2015
  • In this article, poly methyl triethoxy silane was compounded with an inorganic waterproof admixture at a certain ratio to improve the performance of gypsum products; a new type of high-efficiency compound water-proofing additive was also investigated. Furthermore, the waterproof mechanism and the various properties on the hardened gypsum plaster were investigated in detail by XRD and SEM. The results show that the intenerate coefficient of gypsum plaster increased to more than 0.9; the water absorbing rate decreased to less than 10 %. Both the bending strength and the compressive strength of gypsum plaster increased by various degrees. The intenerate coefficient reached a maximum value of 0.73 and the strength of the samples showed almost no change when 5% cement alone was added. In this new type of the high-efficiency compound with waterproof additive, the optimal technological parameters for formulas were obtained to be: 5% cement, 18 % mineral powder, and 0.8% poly methyl triethoxy silane, to compound gypsum plaster. Meanwhile, the production of high performance gypsum as a building material has become possible.

Analysis of vortex induced vibration frequency of super tall building based on wind tunnel tests of MDOF aero-elastic model

  • Wang, Lei;Liang, Shuguo;Song, Jie;Wang, Shuliang
    • Wind and Structures
    • /
    • 제21권5호
    • /
    • pp.523-536
    • /
    • 2015
  • To study the vibration frequency of super high-rise buildings in the process of vortex induced vibration (VIV), wind tunnel tests of multi-degree-of-freedom (MDOF) aero-elastic models were carried out to measure the vibration frequency of the system directly. The effects of structural damping, wind field category, mass density, reduced wind velocity ($V_r$), as well as VIV displacement on the VIV frequency were investigated systematically. It was found that the frequency drift phenomenon cannot be ignored when the building is very high and flexible. When $V_r$ is less than 8, the drift magnitude of the frequency is typically positive. When $V_r$ is close to the critical wind velocity of resonance, the frequency drift magnitude becomes negative and reaches a minimum at the critical wind velocity. When $V_r$ is larger than12, the frequency drift magnitude almost maintains a stable value that is slightly smaller than the fundamental frequency of the aero-elastic model. Furthermore, the vibration frequency does not lock in the vortex shedding frequency completely, and it can even be significantly modified by the vortex shedding frequency when the reduced wind velocity is close to 10.5.

한국 현대건축의 실내에 나타난 하이테크적 특성에 관한 연구 (A Study on the High-Tech Characteristics in Interior of Korean Contemporary Architecture)

  • 남경숙
    • 한국실내디자인학회논문집
    • /
    • 제18호
    • /
    • pp.87-95
    • /
    • 1999
  • The purpose of this study is to find out the High-Tech characteristics in interior of Korean contemporary architecture. To achieve the purpose of this study, the major contents are as follows: 1. Explaining the concept of High-Tech architecture desigv. 2. Explaining the characteristics of High-Tech architecture design in finding out the expressional and technical characteristics. 3. Analysing the building which have propensity to High-Tech design in Korea by means of the expressional and technical characteristics. 4. finding out the characteristics of High-Tech in Korean interior architecture and contributing to study the High-Tech interior desigv. By analysing the buildings showing High-Tech characteristics in interior of Korean contemporary architecture. The ranking of the High-Tech characteristics is lst new material and lightness, last polychrome. The ranking of the building is lst Posco center, 2nd Samsung traffic museum and Kolon new building.

  • PDF

초고층건물의 사각조망에서 촬영된 지붕표면 열화상의 신뢰도 평가 (Evaluating Reliability of Rooftop Thermal Infrared Image Acquired at Oblique Vantage Point of Super High-rise Building)

  • 류택형;엄정섭
    • 한국태양에너지학회 논문집
    • /
    • 제33권5호
    • /
    • pp.51-59
    • /
    • 2013
  • It is usual to evaluate the performance of the cool roof by measuring in-site rooftop temperature using thermal infra-red camera. The principal advantage of rooftop thermal infrared image acquired in oblique vantage point of super high-rise building as a remote sensor is to provide, in a cost-effective manner, area-wide information required for a scattered rooftop target with different colors, utilizing wide view angle and multi-temporal data coverage. This research idea was formulated by incorporating the concept of traditional remote sensing into rooftop temperature monitoring. Correlations between infrared image of super high-rise building and in-situ data were investigated to compare rooftop surface temperature for a total of four different rooftop locations. The results of the correlations analyses indicate that the rooftop surface temperature by the infrared images of super high-rise building alone could be explained yielding $R^2$ values of 0.951. The visible permanent record of the oblique thermal infra-red image was quite useful in better understanding the nature and extent of rooftop color that occurs in sampling points. This thermal infrared image acquired in oblique vantage point of super high-rise made it possible to identify area wide patterns of rooftop temperature change subject to many different colors, which cannot be acquired by traditional in-site field sampling. The infrared image of super high-rise building breaks down the usual concept of field sampling established as a conventional cool roof performance evaluation technique.

고층 건물 화재 관련 R&D 위상 분석 및 신기술 탐색 연구 (R&D Monitoring and Novel Technology Exploration Concerning Research Area about Fire in High-rise Building)

  • 심위;최재경;정현상;허요섭;서성호
    • 한국산업융합학회 논문집
    • /
    • 제23권2_2호
    • /
    • pp.271-280
    • /
    • 2020
  • Due to the development of the urban economy, high-density buildings and skyscrapers have continued to increase in order to alleviate high population densities and to make efficient use of urban space. However, a fire in a high-rise building is a disaster that can lead to massive casualties and property damage because of the difficulty of firefighting and escaping. Various studies have been conducted on these high-rise buildings because they are sympathetic to these difficulties all over the world. In this paper, trends of researches and technologies related to fire in high-rise buildings are analyzed synthetically through thesis and patent data. In other words, we explored the trends of various studies that have been carried out so far through the thesis, and performed technical monitoring on actual implemented technology and newly implemented technologies through patent data. Through this research, we have studied the present and the future of technology for high-rise building fire.

Predicting the lateral displacement of tall buildings using an LSTM-based deep learning approach

  • Bubryur Kim;K.R. Sri Preethaa;Zengshun Chen;Yuvaraj Natarajan;Gitanjali Wadhwa;Hong Min Lee
    • Wind and Structures
    • /
    • 제36권6호
    • /
    • pp.379-392
    • /
    • 2023
  • Structural health monitoring is used to ensure the well-being of civil structures by detecting damage and estimating deterioration. Wind flow applies external loads to high-rise buildings, with the horizontal force component of the wind causing structural displacements in high-rise buildings. This study proposes a deep learning-based predictive model for measuring lateral displacement response in high-rise buildings. The proposed long short-term memory model functions as a sequence generator to generate displacements on building floors depending on the displacement statistics collected on the top floor. The model was trained with wind-induced displacement data for the top floor of a high-rise building as input. The outcomes demonstrate that the model can forecast wind-induced displacement on the remaining floors of a building. Further, displacement was predicted for each floor of the high-rise buildings at wind flow angles of 0° and 45°. The proposed model accurately predicted a high-rise building model's story drift and lateral displacement. The outcomes of this proposed work are anticipated to serve as a guide for assessing the overall lateral displacement of high-rise buildings.

고층건축물 수직 샤프트 연돌효과 해소방법에 대한 연구 (The Study on the Solution of Stack effect in the Vertical shaft of High-rise Buildings)

  • 김진수;장희철
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.242-245
    • /
    • 2007
  • 초고층건물의 주된 피난경로인 계단실에 발생하는 연돌효과는 계단실 차압분포에 큰 영향을 주고 피난에 장애가 될 수도 있으므로 적정 범위 내에서 억제되어야한다. 고층건물의 연돌효과를 해소하는 방법을 찾기 위해 몇 가지 경우에 대해 시뮬레이션을 하고 계단실 상하부의 fan으로 가압과 감압을 적절히 병용한 결과 연돌효과에 의한 차압불균형을 해소할 수 있었다.

  • PDF

커튼월용 1액형 구조용 실란트 물성 평가 연구 (Evaluation of one component structural sealant for curtain wall.)

  • 한창화;정진영;배기선
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.228-229
    • /
    • 2014
  • Recently, to ensure the high openness and prospect right of the building, curtain wall system is mainly applied to the high-rise buildings at domestic and overseas. As a result, the use of Structural Sealant is increasing. Structural Glazing Sealant is applied with the glass and AL-FRAME (Mullion) that the strong structural strength is required to hold. However, the structural sealant at the construction site in a variety of external influences, such as wind load, thermal load, uv, chemical pollutants etc, in case of storing condition, if structural sealant stored in high temperature for a long period time, it will not perform well compared with initial performance. In this study, the influence of the performance of one-component structural sealant evaluated for proper storage conditions at the construction site and how to use the non-intended.

  • PDF