• Title/Summary/Keyword: high bog

Search Result 165, Processing Time 0.018 seconds

EFFECT OF THE EXPONENTIAL CURING OF COMPOSITE RESIN ON THE MICROTENSILE DENTIN BOND STRENGTH OF ADHESIVES (복합레진의 exponential 중합법이 상아질접착제의 미세인장접착강도에 미치는 영향)

  • Seong, So-Rae;Seo, Duck-kyu;Lee, In-Bog;Son, Ho-Hyun;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.125-133
    • /
    • 2010
  • Objectives: Rapid polymerization of overlying composite resin causes high polymerization shrinkage stress at the adhesive layer. In order to alleviate the shrinkage stress, increasing the light intensity over the first 5 seconds was suggested as an exponential curing mode by an LED light curing unit (Elipar FreeLight2, 3M ESPE). In this study, the effectiveness of the exponential curing mode on reducing stress was evaluated with measuring microtensile bond strength of three adhesives after the overlying composite resin was polymerized with either continuous or exponential curing mode. Methods: Scotchbond Multipurpose Plus (MP, 3M ESPE), Single Bond 2 (SB, 3M ESPE), and Adper Prompt (AP, 3M ESPE) were applied onto the flat occlusal dentin of extracted human molar. The overlying hybrid composite (Denfil, Vericom, Korea) was cured under one of two exposing modes of the curing unit. At 48h from bonding, microtensile bond strength was measured at a crosshead speed of 1.0 mm/min. The fractured surfaces were observed under FE-SEM. Results: There was no statistically significant difference in the microtensile bond strengths of each adhesive between curing methods (Two-way ANOVA, p > 0.05). The microtensile bond strengths of MP and SB were significantly higher than that of AP (p < 0.05). Mixed failures were observed in most of the fractured surfaces, and differences in the failure mode were not observed among groups. Conclusion: The exponential curing method had no beneficial effect on the microtensile dentin bond strengths of three adhesives compared to continuous curing method.

Compaction Characteristics of Multi-cropping Paddy Soils in South-eastern Part of Korea (우리나라 동남부 다모작 논토양의 경반화 특성)

  • Yun, Eul-Soo;Jung, Ki-Yeul;Park, Ki-Do;Sonn, Yeon-Kyu;Park, Chang-Yeong;Hwang, Jae-Bog;Nam, Min-Hee
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.5
    • /
    • pp.688-695
    • /
    • 2011
  • This study was carried out for some survey about soil compaction in the multi-cropping system of paddy field. Investigated sites were 90 farmer's fields in south-eastern part of Korea. The tillage practices season was different according to cropping system of paddy; in spring for mono rice cultivation and in autumn for the multi-cropping field. The average tillage depth in investigated sites was about 25 cm, however, it is different between the farmer's tillage practices and soil characteristics. It is high correlation to tillage deep and minimum resistance of penetration. The reaching soil deep to maximum resistance of penetration was about 27 cm, and average penetration resistance of the deep is 1.8~2.0 MPa for moderately fine-textured soils and more than 3.0 MPa for moderately coarse-textured soils. The difference of penetration resistance between cultivating and compacted layer was in order to sandy loam > clayey loam > clayey, and the difference was lesser in poorly drained soils than somewhat poorly ones. In the rice mono cropping field, the maximum resistance in no-tillage for 15 years was 1.18~1.25 Mpa at 20~25 cm in soil deep, however, the resistance of field with every year tillage practices was 2.03~2.21 Mpa. In the extremely compacted sandy loam textured soils, the penetration resistance at 30 cm in soil depth was drastically reduced by the subsoil from 5.2 Mpa to 3.2 Mpa, and the watermelon root in plastic film house was deep elongated.

Development of control system for complex microbial incubator (복합 미생물 배양기의 제어시스템 개발)

  • Hong-Jik Kim;Won-Bog Lee;Seung-Ho Lee
    • Journal of IKEEE
    • /
    • v.27 no.1
    • /
    • pp.122-126
    • /
    • 2023
  • In this paper, a control system for a complex microbial incubator was proposed. The proposed control system consists of a control unit, a communication unit, a power supply unit, and a control system of the complex microbial incubator. The controller of the complex microbial incubator is designed and manufactured to convert analog signals and digital signals, and control signals of sensors such as displays using LCD panels, water level sensors, temperature sensors, and pH concentration sensors. The water level sensor used is designed and manufactured to enable accurate water level measurement by using the IR laser method with excellent linearity in order to solve the problem that existing water level sensors are difficult to measure due to foreign substances such as bubbles. The temperature sensor is designed and used so that it has high accuracy and no cumulative resistance error by measuring using the thermal resistance principle. The communication unit consists of two LAN ports and one RS-232 port, and is designed and manufactured to transmit signals such as LCD panel, PCT panel, and load cell controller used in the complex microbial incubator to the control unit. The power supply unit is designed and manufactured to supply power by configuring it with three voltage supply terminals such as 24V, 12V and 5V so that the control unit and communication unit can operate smoothly. The control system of the complex microbial incubator uses PLC to control sensor values such as pH concentration sensor, temperature sensor, and water level sensor, and the operation of circulation pump, circulation valve, rotary pump, and inverter load cell used for cultivation. In order to evaluate the performance of the control system of the proposed complex microbial incubator, the result of the experiment conducted by the accredited certification body showed that the range of water level measurement sensitivity was -0.41mm~1.59mm, and the range of change in water temperature was ±0.41℃, which is currently commercially available. It was confirmed that the product operates with better performance than the performance of the products. Therefore, the effectiveness of the control system of the complex microbial incubator proposed in this paper was demonstrated.

The Content of Minerals and Vitamins in Commercial Beverages and Liquid Teas (유통음료 및 액상차 중의 비타민과 미네랄 함량)

  • Shin, Young;Kim, Sung-Dan;Kim, Bog-Soon;Yun, Eun-Sun;Chang, Min-Su;Jung, Sun-Ok;Lee, Yong-Cheol;Kim, Jung-Hun;Chae, Young-Zoo
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.4
    • /
    • pp.322-329
    • /
    • 2011
  • This study was done to analyze the contents of minerals and vitamins to compare the measured values of minerals, vitamins with labeled values of them in food labeling and to investigate the ratio of measured values to labeled values in 437 specimen with minerals and vitamins - fortified commercial beverages and liquid teas. Content of calcium and sodium in samples after microwave digestion was analyzed with an ICP-OES (Inductively Coupled Plasma Optical Emission Spectrometer) and vitamins were determined using by HPLC (High Performance Liquid Chromatography). The measured values of calcium were ranged 80.3~142.6% of the labeled values in 21 samples composed calcium - fortified commercial beverages and liquid teas. In case of sodium, measured values were investigated 33.9~48.5% of the labeled values in 21 sports beverages. The measured values of vitamin C, vitamin $B_2$ and niacin were ranged 99.7~2003.6, 81.1~336.7, 90.7~393.2% of the labeled values in vitamins - fortified commercial beverages and liquid teas, 57, 12, 11 samples. To support achievement of the accurate nutrition label, there must be program and initiatives for better understanding and guidances on food labelling and nutrition for food manufacture.

The Results of Postoperative Radiation Therapy for Perihilar Cholangiocarcinoma (간문부 담도암에서 수술 후 방사선 치료의 결과)

  • Lee, Yu-Sun;Park, Jae-Won;Park, Jin-Hong;Choi, Eun-Kyung;Ahn, Seung-Do;Lee, Sang-Wook;Song, Si-Yeol;Lee, Sung-Gyu;Hwang, Shin;Lee, Young-Joo;Park, Kwang-Min;Kim, Ki-Hun;Ahn, Chul-Soo;Moon, Deok-Bog;Chang, Heung-Moon;Ryu, Min-Hee;Kim, Tae-Won;Lee, Jae-Lyun;Kim, Jong-Hoon
    • Radiation Oncology Journal
    • /
    • v.27 no.4
    • /
    • pp.181-188
    • /
    • 2009
  • Purpose: The aim of this study was to evaluate the results of postoperative radiotherapy in a case of perihilar cholagiocarcinoma by analyzing overall survival rate, patterns of failure, prognostic factors for overall survival, and toxicity. Materials and Methods: Between January 1998 and March 2008, 38 patients with perihilar cholangiocarcinoma underwent a surgical resection and adjuvant radiotherapy. The median patient age was 59 years (range, 28 to 72 years), which included 23 men and 15 women. The extent of surgery was complete resection in 9 patients, microscopically positive margins in 25 patients, and a subtotal resection in 4 patients. The tumor bed and regional lymphatics initially received 45 Gy or 50 Gy, but was subsequently boosted to a total dose of 59.4 Gy or 60 Gy in incompletely resected patients. The median radiotherapy dose was 59.4 Gy. Concurrent chemotherapy was administered in 30 patients. The median follow-up period was 14 months (range, 6 to 45 months). Results: The 3-year overall survival and 3-year progression free survival rates were 30% and 8%, respectively. The median survival time was 28 months. A multivariate analysis showed that differentiation was the only significant factor for overall survival. The 3-year overall survival was 34% in R0 patients and 20% in R1 patients. No statistically significant differences in survival were found between the 2 groups (p=0.3067). The first site of failure was local in 18 patients (47%). No patient experienced grade 3 or higher acute toxicity and duodenal bleeding developed in 2 patients. Conclusion: Our results suggest that adjuvant RT might be a significant factor in patients with a positive margin following a radical resection. However, there was still a high locoregional recurrence rate following surgery and postoperative radiotherapy. Further study is necessary to enhance the effect of the adjuvant radiotherapy.