• Title/Summary/Keyword: high angle case

Search Result 476, Processing Time 0.03 seconds

Behavior of Graphite and Formation of Intermetallic Compound Layer in Hot Dip Aluminizing of Cast Iron (주철 - 알루미늄 합금의 Hot Dip Aluminizing시 흑연 및 금속간화합물 층의 형성 거동)

  • Han, Kwang-Sic;Kang, Yong-Joo;Kang, Mun-Seok;Kang, Sung-Min;Kim, Jin-Su;Son, Kwang-Suk;Kim, Dong-Gyu
    • Journal of Korea Foundry Society
    • /
    • v.31 no.2
    • /
    • pp.66-70
    • /
    • 2011
  • Hot dip aluminizing (HDA) is widely used in industry for improving corrosion resistance of material. The formation of intermetallic compound layers during the contact between dissimilar materials at high temperature is common phenomenon. Generally, intermetallic compound layers of $Fe_2Al_5$ and $FeAl_3$ are formed at the Al alloy and Fe substrate interface. In case of cast iron, high contact angle of graphite existed in the matrix inhibits the formation of intermetallic compound layer, which carry with it the disadvantage of a reduced reaction area and mechanical properties. In present work, the process for the removal of graphite existed on the surface of specimen has been investigated. And also HDA was proceeded at $800^{\circ}C$ for 3 minutes in aluminum alloy melt. The efficiency of graphite removal was increased with the reduction of particle size in sanding process. Graphite appears to be present both in the region of melting followed by re-solidification and in the intermetallic compound layer, which could be attributed to the fact that the surface of cast iron is melted down by the formation of low melting point phase with the diffusion of Al and Si to the cast iron. Intermetallic compound layer consisted of $Fe(Al,Si)_3$ and $Fe_2Al_5Si$, the layer formed at cast iron side contained lower amount of Si.

Direction-of-Arrival Estimation in Broadband Signal Processing : Rotation of Signal Subspace Approach (광대역 신호 처리에서의 도래각 추정 : Rotation of Signal Subspaces 방법)

  • Kim, Young-Soo
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.7
    • /
    • pp.166-175
    • /
    • 1989
  • In this paper, we present a method which is based on the concept of the rotation of subspaces. This method is highly related to the angle (or distance) between subspaces arising in many applications. An effective procedures is first derived for finding the optimal transformation matrix which rotates one subspace into another as closely as possible in the least squares sense , and then this algorithm is applied to the solution to general direction-of-arrival estimation problem of multiple broadband plane waves which may be a mixture of incoherent, partially coherent or coherent. In this typical application, the rotation of signal subspaces (ROSS) algorithm is effectively developed to achieve the high performance in the active systems for the case in which the noise field remains invariant with the measurement of the array spectral density matrix (or data matrix). It is not uncommon to observe this situation in sonar systems. The advantage of this techniques is not to require the preliminary processing and spatial prefiltering which is used in Wang-Kaveh's CSS focusing method. Furthermore, the array's geometry is not restricted. Simulation results are presented to illustrate the high performance achieved with this new approach relative to that obtained with Wang-Kaveh's CSS focusing method for incoherent sources and forward-backward spatial smoothed MUSIC for coherent sources including the signal eigenvector method (SEM).

  • PDF

A detector system for searching lost γ-ray source

  • Khan, Waseem;He, Chaohui;Cao, Yu;Khan, Rashid;Yang, Weitao
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1524-1531
    • /
    • 2020
  • The aim of this work is to develop a Geiger-Muller (GM) detector system for robot to look for a radioactive source in case of a nuclear emergency or in a high radiation environment. In order to find a radiation source easily, a detector system, including 3 detectors, was designed to search γ-ray radiation sources autonomously. First, based on GEANT4 simulation, radiation dose rates in 3 Geiger-Muller (GM) counters were simulated at different source-detector distances, distances between detectors and angles. Various sensitivity analyses were performed experimentally to verify the simulated designed detector system. A mono-energetic 137Cs γ-ray source with energy 662 keV and activity of 1.11 GBq was used for the observation. The simulated results were compared with the experimental dose rate values and good agreements were obtained for various cases. Only based on the dose rates in three detectors, the radiation source with a specific source activity and angle was localized in the different location. A method was adopted with the measured dose rates and differences of distances to find the actual location of the lost γ-ray source. The corresponding angles of deviation and detection limits were calculated to determine the sensitivity and abilities of our designed detector system. The proposed system can be used to locate radiation sources in low and high radiation environments.

Effect of Secondary Flow Direction on Film Cooling Effectiveness (이차유동의 방향이 막냉각 효율에 미치는 영향)

  • Park, Sehjin;Choi, Seok Min;Sohn, Ho-Seong;Chung, Heeyoon;Cho, Hyung Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.7
    • /
    • pp.655-663
    • /
    • 2013
  • Several studies of film cooling were accomplished with a secondary flow channel parallel to the main flow. In real turbine blades, however, the direction of the secondary flow channel is generally normal to the main flow. Thus, this study performs a numerical analysis to investigate the effects of the direction of secondary flow on the effectiveness of double-jet film cooling. The blowing ratio is 1 and 2, and the lateral injection angle is $22.5^{\circ}$. The parallel channel case creates a well-developed anti-kidney vortex with a blowing ratio of 1, and the laterally averaged film cooling effectiveness of the parallel channel is enhanced compared to the normal channel. The normal channel shows higher performance with a blowing ratio of 2. Both cases show high film cooling effectiveness. These phenomena can be attributed to a high blowing ratio and flow rate rather than an anti-kidney vortex.

A Study on the Solidification and Purification of High Purity Aluminium Alternate Stirring Method (정역 회전법에 의한 고순도 알루미늄의 응고 및 정련에 관한 연구)

  • Kim, Wook;Lee, Joung-Ki;Baik, Hong-Koo;Heo, Seong-Gang
    • Journal of Korea Foundry Society
    • /
    • v.12 no.3
    • /
    • pp.220-229
    • /
    • 1992
  • The degree of purification and the macrostructure of high purity aluminium were studied through the alternate stirring method in order to improve the nonuniformity of solute concentration in the unidirectional stirring method. The $2^3$ factorial design was done to examine the effects of experimental factors more qualitatively. In the relatively low stirring speed of 1500 rpm with alternate stirring mode, the uniform solute profile and refined grain structure were obtained due to strong washing effect and turbulent fluid flow. It was induced by the transition of the momentum boundary layer by alternation of the stirrer. It was concluded from this study that the alternate stirring mode was more effective to obtain the uniformity of solute even in the stirring speed of 1500 rpm. But the degree of purification decreased below the critical alternating period. When 2N(99.8wt.%) aluminium was used as the starting material the morphology of solid-liquid showed the cellular shape and the columnar grains were inclined to the direction of rotation. This inclined grain growth resulted from the difference of relative velocities of solid and liquid. The inclined angle was increased as the stirring speed increased and solidification proceeded. In the case of 4N aluminium, there was no inclined grain growth and it was confirmed from the macrostructure and SEM work that the morphology of solid-liquid interface was planar. From the factorial design, it was found that the alternate stirring mode showed poorer purification effect than that of unidirectional stirring mode at low speed(500 rpm). In addition, the factor that had the most significant effect on the degree of purification was the stirring speed.

  • PDF

Correction of Transverse Discrepancy with Slowly Maxillary Expansion by Hyrax type expander in Adult Patient (성인에서 Hyrax 장치로 완속상악확장하여 폭경부조화를 개선한 증례)

  • Kwak, Kyoung Ho;Kim, Seong Sik;Kim, Yong-Il;Park, Soo-Byung;Son, Woo-Sung
    • The Journal of the Korean dental association
    • /
    • v.55 no.6
    • /
    • pp.400-410
    • /
    • 2017
  • Approximately 30% of adult patients who want orthodontic treatment have transverse discrepancy with insufficient width of the maxilla. Particularly, in Class III patients requiring orthognathic surgery, the frequency of insufficient width of the maxillary arch related to respiratory problems is high. We report a case of non-surgical maxillary expansion using a Hyrax type expander with an orthognathic surgery, based on the reports that the ratio of non-fused midpalatal suture is not high in adults. A 30 years and 2 months old woman with a long face showed an Angle Class III with a vertical growth pattern. Class III molar and canine relation, anterior edge bite, and mandibular incisor compensatory lingual inclination were observed. The posterior buccal overjet seemed to be appropriate, but I diagnosed that there was a transverse discrepancy, for the following reasons. The inter-canine and inter-molar widths were sufficient but excessive lingual inclination of the mandibular molars was observed when assessing the bucco-lingual inclination based on the center of resistance of the maxillary and mandibular first molar. For this reason, it was expected that intercuspal interference would occur during orthodontic decompensation. Therefore, slow maxillary expansion using Hyrax type expander was performed and 2-jaw rotation surgery was performed to improve aesthetic and occlusion. Adults can also improve width discrepancy by non-surgical methods, which can avoid SARPE requiring additional surgery or segmental surgery lacking stability and predictability.

  • PDF

THE USE OF MEDPORTM(POROUS HIGH-DENSITY POLYETHYLENE) IN ORAL AND MAXILLOFACIAL REGION (구강악안면영역에서의 MedporTM의 임상적용)

  • Park, Gwang-Bum;Yeo, Hwan-Ho;Kim, Su-Gwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.1
    • /
    • pp.60-64
    • /
    • 1999
  • Recently, for the reconstruction of bony defect and cosmetic improvement, many graft materials and implants have been widely used in the various surgical situations. The alloplastic materials have many advantages such as simplicity of operation, no additional need of surgery, and easy manipulation. The $Medpor^{TM}$(porous high-density polyethylene, Porex Co., USA) was initially studied in 1972 for surgical implant and introduced as an implant material for oral and maxillofacial region by Sauer and King in 1988. This material permits full ingrowth of bone into the implants, substantially increasing the implant's incorporation into the recipient site. It can be shaved during the surgery, which results in an improvement and prefabricated various size and shapes to fit into the surgical defect. The $Medpor^{TM}$ was used in 32 patients from 1995 to 1997 at the maxillofacial region. It was used for paranasal augmentation in 24 cases, for malar augmentation in 2 cases, for infraorbital augmentation in 2 cases, for mandibular angle augmentation in 2 cases, for mandibular body augmentation in 2 cases, for chin vertical augmentation in 1 case. It was mainly fixed with miniplate or screw. There were few complications except one infection and one exposure of the implant.

  • PDF

Spray Characteristics of Supersonic Liquid Jet by a Nozzle Geometry of Miniature High-Pressure Injection System (축소형 초고압 분사 시스템의 노즐 형상에 따른 초음속 액체 제트 분무 특성에 관한 연구)

  • Shin, Jeung-Hwan;Lee, In-Chul;Kim, Heuy-Dong;Koo, Ja-Ye
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.177-180
    • /
    • 2010
  • Two-stage light gas gun, sorted with Ballistic Range System, is used to research spray characteristics of supersonic liquid jets. When high pressure tube was pressurized to the 135 bar, diaphragm films which composed with OHP film are ruptured. Expansion gases accelerate a projectile approximately 250 m/s at the exit of pump tube. And accelerated projectile collides with liquid storage part and liquid jets were injected into supersonic conditions. Supersonic liquid jets show the multiple jets and generate shockwave at the forward region of jets. Supersonic liquid jets of speed and shockwave angle have different value at each case. Supersonic liquid jets with minimum velocities are injected with M=1.53 at the geometry condition of L/d=23.8.

  • PDF

Study of Ride Comfort on Train through Physiological Parameter (생체 신호를 이용한 열차 승차감 평가 시스템 연구)

  • Song, Yong-Soo;Oh, Suk-Moon;Lee, Jae-Ho;Kim, Yong-Kyu
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.1
    • /
    • pp.237-250
    • /
    • 2011
  • The train transportation has a lot of advantages-energy efficiency is high, it is eco-friendly, safety is better than normal roads and it is possible for people to arrive on time. In these days, the valuation of ride comfort, which is only limited to road transportation, is newly recognized in order to having competitiveness from other transportation. Especially, in the development of the Korean high-speed railroad business, the ride comfort enhancement of train is very important problem to be solved. Currently, there are international standards of ride comfort such as UIC13, ISO2631. In Korea case, although it has own standard like KS R9216, it mainly depends on the physical parameter such as vibration and noise. So recently, in the valuation of ride comfort, the movements of living parameter technique introduction are increasing on the base of Japan and many developed countries of Europe techniques. Presently, the method of train ride comfort is mainly based of vibration, that is, mechanical parameter adding selection of variable acceleration and noise. This paper would like to show biological parameter; heart rate and blood pressure variation. This method is more direct, based on human body response, than mechanical parameter method. In this experiment, the variability of heart rate and blood pressure of passengers according to tilting angle change of Train, the Korean tilting train, we are supposed to know that the extent of tilting on the simulation has influence on variability of heart rate and blood pressure, which are living parameter of heart's blood.

A Very Compact 60 GHz LTCC Power Amplifier Module (초소형 60 GHz LTCC 전력 증폭기 모듈)

  • Lee, Young-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.11 s.114
    • /
    • pp.1105-1111
    • /
    • 2006
  • In this paper, using low-temperature co-fired ceramic(LTCC) based system-in-package(SiP) technology, a very compact power amplifier LTCC module was designed, fabricated, and then characterized for 60 GHz wireless transmitter applications. In order to reduce the interconnection loss between a LTCC board and power amplifier monolithic microwave integrated circuits(MMIC), bond-wire transitions were optimized and high-isolated module structure was proposed to integrate the power amplifier MMIC into LTCC board. In the case of wire-bonding transition, a matching circuit was designed on the LTCC substrate and interconnection space between wires was optimized in terms of their angle. In addition, the wire-bonding structure of coplanar waveguide type was used to reduce radiation of EM-fields due to interconnection discontinuity. For high-isolated module structure, DC bias lines were fully embedded into the LTCC substrate and shielded with vias. Using 5-layer LTCC dielectrics, the power amplifier LTCC module was fabricated and its size is $4.6{\times}4.9{\times}0.5mm^3$. The fabricated module shows the gain of 10 dB and the output power of 11 dBm at P1dB compression point from 60 to 65 GHz.