• Title/Summary/Keyword: hemostatic

Search Result 148, Processing Time 0.026 seconds

THE EFFECT OF HEMOSTATIC SOLUTIONS ON DENTIN PERMEABILITY (치과용 지혈제가 상아질 투과도에 미치는 영향)

  • Kim, Chong-Hyun;Shim, June-Sung;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.4
    • /
    • pp.472-483
    • /
    • 2000
  • Before impression making in the fixed restorations or other prosthesis, hemostatic solutions are used for hemostasis and moisture control. Hemostatic solutions effectively control bleeding but their major ingredients, acid removes smear layers which are formed in the tooth preparation, exposes the dentinal tubular orifices which are occluded by smear layers, makes dentinal tubular fluid displace more easily to the various external stimulus, and according to the hydrodynamic theory, consequently causes dentin hypersensitivity. To know the effect of hemostatic solutions on dentin permeability, coronal dentin discs, 1mm in thickness, were prepared from extracted third molars free from decay and wear, and a split chamber device was used. Hydraulic conductance values and SEMs, which were measured before and after treatment with $Astringedentr^{(R)},\;Altract^(R)\;and\;Epri-dent^{(R)}$, were compared and ana-lysed. The following conclusions were drawn: 1. Hydraulic conductance values which were measured after the treatment of hemostatic solutions were increased in all groups(p<0.05). 2. %change values of hydraulic conductance were compared but no significant difference was found among the three hemostatic solutions(p<0.05). 3. On SEM observations of all groups, after treatment smear layers were removed and dentinal tubular orifices were partially exposed. On the basis of these conclusions, the reckless use of hemostatic solutions should be restricted, and when in use, various methods should be considered to protect dentin.

  • PDF

Biologic response of local hemostatic agents used in endodontic microsurgery

  • Jang, Youngjune;Kim, Hyeon;Roh, Byoung-Duck;Kim, Euiseong
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.2
    • /
    • pp.79-88
    • /
    • 2014
  • Appropriate use of local hemostatic agent is one of the important factors on the prognosis of endodontic microsurgery. However, most investigations to date focus on the hemostatic efficacy of the agents, whereas their biologic characteristics have not received enough attention. The purpose of this paper was to review the biologic response of local hemostatic agents, and to provide clinical guidelines on their use during endodontic microsurgery. Electronic database (PUBMED) was screened to search related studies from 1980 to 2013, and 8 clinical studies and 18 animal studies were identified. Among the materials used in these studies, most widely-investigated and used materials, epinephrine, ferric sulfate (FS) and calcium sulfate (CS), were thoroughly discussed. Influence of these materials on local tissue and systemic condition, such as inflammatory and foreign body reaction, local ischemia, dyspigmentation, delayed or enhanced bone and soft tissue healing, and potential cardiovascular complications were assessed. Additionally, biological property of their carrier materials, cotton pellet and absorbable collagen, were also discussed. Clinicians should be aware of the biologic properties of local hemostatic agents and their carrier materials, and should pay attention to the potential complications when using them in endodontic microsurgery.

Endoscopic Hemostatic Treatment of Peptic Ulcer Bleeding (소화성 궤양 출혈의 내시경 치료)

  • Choe, Yeon Hwa;Park, Jun Chul
    • The Korean journal of helicobacter and upper gastrointestinal research
    • /
    • v.18 no.4
    • /
    • pp.235-241
    • /
    • 2018
  • Peptic ulcer bleeding is a common complication of peptic ulcer disease and the most common cause of upper gastrointestinal bleeding. Despite advances in drug usage and endoscopic modalities, no significant improvement is observed in the mortality rate of bleeding ulcers. The purpose of this review is to discuss various endoscopic hemostatic methods to treat peptic ulcer bleeding. Endoscopic hemostatic techniques can be classified into injection, mechanical, electrocoagulation, hemostatic powder, and endoscopic Doppler-guided hemostatic therapies (the last mentioned being a newly developed technique). Endoscopic hemostasis can be performed as mono or combination therapy using the aforementioned methods. Endoscopic hemostasis is the most important treatment for patients with peptic ulcer bleeding. Endoscopists should consider the treatment approach for peptic ulcer bleeding based on patient characteristics, the size and shape of the lesion, the endoscopist's expertise, and the resources and circumstances at each hospital. Follow-up studies are needed to evaluate the efficacy of newly developed hemostatic powder therapy and endoscopic Doppler-guided hemostasis.

Usefulness of Balloon-type Hemostatic Device After Transarterial Chemoembolization (간동맥 화학색전술 후 풍선형 지혈기구의 유용성)

  • Kim, Seung-Gi
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.181-186
    • /
    • 2019
  • Transarterial chemoembolization is one of the most representative procedures for puncture of the femoral artery. In addition, the same procedure is often repeatedly performed many times, and Hepatocellular carcinoma patients due to cancer is significantly lowered blood tests, regardless of platelet counts are not good enough to stop bleeding. More importantly, hepatocellular carcinoma has a high degree of complication and disease severity, which makes it less likely that the condition of the body will be relatively inferior to other patients. In order to prevent delayed hemorrhage of the femoral artery puncture site after the procedure, it is advised to absolutely stabilize the limb so that it does not bend the limb for 3 hours after climbing in the ward. Therefore, I have been complaining about inconvenience. In addition, in order to prevent delayed hemorrhage after hemostasis, balloon type hemostatic device was used instead of sand bag which was placed on hemostatic site. The results of this study were compared with the results of actual application. The use of a balloon-type hemostatic device to increase the effectiveness of continuous hemostasis and to minimize the inconvenience during the time of patient's absolute bed rest, rather than raising the sandbag to prevent primary delayed hemorrhage by various methods in transarterial chemoembolization. It can be used as a substitute for existing sand bags because it can alleviate pain, increase satisfaction, and can be used as a disposable one.

Hemostatic Action of Torilis fructus (사상자 물추출물의 혈액 응고 작용)

  • 김환수;박병욱;김기협;박광식
    • YAKHAK HOEJI
    • /
    • v.39 no.1
    • /
    • pp.55-60
    • /
    • 1995
  • The acetone precipitates of the hot water extract of Torilis ftuctus showed strong hemostatic activity which was not inhibited by aspirin. This activity was not through platelet activation but possibly through activating some coagulation factors in plasma. The hemostatic action of the precipitates was not active by oral adminitration and no behavioral toxicity was appeared in treated mice. However, mice treated with the acetone precipitates through tail vein showed serious tremor and then were killed probably by the thrombus produced in the body. The hemostatic activity was still remained after treatment with $\beta$-glucosidase, $\beta$-alactosidase, $\alpha$-amylase, subtilisin BPN', or trypsin but completely lost by acid hydrolysis. The active components seemed to be a complex of unidentified macromolecules to which some phenolic compounds were strongly bound.

  • PDF

Effect of an aluminum chloride hemostatic agent on the dentin shear bond strength of a universal adhesive

  • Sujin Kim;Yoorina Choi;Sujung Park
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.2
    • /
    • pp.14.1-14.11
    • /
    • 2023
  • Objectives: This study investigated the effect of an aluminum chloride hemostatic agent on the shear bond strength (SBS) of a universal adhesive to dentin. Materials and Methods: Eighty extracted human molars were trimmed at the occlusal dentin surfaces and divided mesiodistally. According to hemostatic agent application, specimens were randomly allocated into control (C) and hemostatic agent (Traxodent; H) groups. Each group was divided into 4 subgroups according to the adhesive system (n = 20): Scotchbond Multi-Purpose (SBER), Clearfil SE Bond (CLSE), All-Bond Universal etch-and-rinse mode (ALER), and All-Bond Universal self-etch mode (ALSE). SBS was measured for half of the specimens at 24 hours, and the other half were thermocycled in water baths (group T). Fracture surfaces were examined to determine the failure mode. The SBS was measured, and data were analyzed using 1-way analysis of variance, the Student's t-test, and the Tukey honestly significant difference test (p = 0.05). Results: No significant differences in SBS were found between groups C and H for any adhesive system at 24 hours. After thermocycling, a statistically significant difference was observed between CT+ALSE and HT+ALSE (p < 0.05). When All-Bond Universal was applied to hemostatic agent-contaminated dentin, the SBS of H+ALSE was significantly lower than that of H+ALER (p < 0.05). The SBER subgroups showed no significant differences in SBS regardless of treatment and thermocycling. Conclusions: When exposed dentin was contaminated by an aluminum chloride hemostatic agent before dentin adhesive treatment, application of All-Bond Universal in etch-and-rinse mode was superior to self-etch mode.

Experimental Assessment of Hemostatic Agents: Comparison with New Developed Chitosan-Based Material (신개발 키토산 제재의 지혈 효과에 대한 비교)

  • Cho, Young-Kyoo;Lee, Sang-Yun;Kim, Tae-Jung;Lim, Hyun-Ju;Oh, Eun-Jung;Lee, Soo-Bok;Choi, Kang-Young;Yang, Jung-Dug;Cho, Byung-Chae;Chung, Ho-Yun
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.369-375
    • /
    • 2011
  • Purpose: Many hemostatic agents and dressings have been tested with variable degree of success. Chitosan has a positive charge, it attracts red blood cells, which have a negative charge. Our goal is to test the efficacy of new developed chitosan-based hemostatic materials in providing durable hemostasis in a high-flow arterial wound model. Methods: We compared each group with SD rats motality tests and in vitro blood compatibility test by blood clotting index (BCI). We devided the SD rats into 6 groups (N =15) by type of hemostatic agents. A: 100% nonwoven chitosan (degree of the deacetylation: 90%). B: 50% N-acetylation on nonwoven of chitosan gel (degree of the deacetylation: 50%). C: 60% N-acetylation on nonwoven of chitosan ge (degree of the deacetylation: 40%)l. D: Cutanplast$^{(R)}$. E: HemCon$^{(R)}$ F: Gauze. In vivo test, a proximal arterial injury was created in unilateral femoral arteries of 90 anesthetized SD rats. Each materials was made same size and thickness then applied to the injury site for 3 minutes. In vitro test, we compared each group with BCI in human blood. Results: In vivo test, group A showed lower motality rate of 46% than any other groups, Group B and C showed lower motality rate of 60% than group D and E's motality rate of 66%. In vitro test, BCI of group A ($30.6{\pm}1.2$) and B ($29.3{\pm}1.0$) were showed nearly about group D ($29.1{\pm}1.8$) and E ($27.4{\pm}1.6$). Group C ($37.1{\pm}2.0$) showed higher BCI than group A and B, it means group C decreased blood clotting. Conclusion: In conclusion, this study suggests a newly developed chitosan-based hemostatic materials induced durable hemostasis and increased blood clotting, and are considered as effective biologic hemostatic agents.

Difference in Bonding Strength of RMGIC according to Type of Hemostatic Agent in Primary Tooth (지혈제의 종류에 따른 레진 강화형 글라스아이오노머 시멘트 결합력의 차이)

  • Back, Seolah;Lee, Joonhaeng;Kim, Jongbin;Han, Miran;Kim, Jong Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.4
    • /
    • pp.460-466
    • /
    • 2021
  • The purpose of this study was to compare the effect of the hemostatic agent containing aluminum chloride with hemostatic agent containing ferric sulfate on the shear bond strength of resin-modified glass ionomer cement(RMGIC) to dentin in primary tooth. Twenty extracted non-carious human primary teeth were collected in this study. The specimens were cut to expose dentin and polished. The specimens were randomly seperated into 3 groups for treatment; group I: polyacrylic acid(PAA), RMGIC; group II: aluminum chloride, PAA, RMGIC; group III: ferric sulfate, PAA, RMGIC Ten specimens from each group were subjected to shear bond strength test. The mean shear bond strength of each group was as follows: 10.07 ± 1.83 MPa in Group I, 7.62 ± 0.78 MPA in group II, 5.23 ± 0.78 MPa in group III. There were significant differences among all groups(p < 0.001). In conclusion, both aluminum chloride hemostatic agent and ferric sulfate hemostatic agent decreased the shear bond strength of RMGIC to dentin. And ferric sulfate hemostatic agent decreased the shear bond strength of RMGIC more than the aluminium chloride hemostatic agent.

Cardiocirculatory, biochemical and hemostatic evaluation of dogs with hyperadrenocorticism at diagnosis and after treatment

  • Soares, Frederico Aecio Carvalho;Matheus, Juliana Pereira;Carvalho, Guilherme Luiz;Neuwald, Elisa Barp;Poppl, Alan Gomes;Valle, Stella Faria;Gonzalez, Felix Hilario Diaz
    • Korean Journal of Veterinary Research
    • /
    • v.56 no.3
    • /
    • pp.161-166
    • /
    • 2016
  • Hyperadrenocorticism (HAC) is a common endocrinopathy among dogs that causes multisystemic signs. This study was conducted to evaluate cardiocirculatory, biochemical, and hemostatic parameters in dogs with HAC at diagnosis, in addition to verifying whether abnormal parameters could be controlled by initial treatment with trilostane. Fifteen dogs with HAC were assessed by systolic blood pressure measurement, electrocardiography, Doppler echocardiography, serum concentration of troponin I, and biochemical and hemostatic profile at diagnosis and after trilostane therapy. Unlike biochemical parameters, hemostatic and cardiocirculatory parameters were not significantly influenced by the onset of treatment. The authors believe that clinical treatment with trilostane for 3 to 4 months might not be sufficient for the stabilization of cardiocirculatory abnormalities such as hypertension. Therefore, dogs with HAC must receive cardiocirculatory monitoring at diagnosis and during drug treatment.

Evaluation of Hemostatic Function with Thromboelastography in Dogs with Hypercoagulable Diseases

  • Kim, Ja-Won;Nam, Aryung;Lee, Kyu-Pil;Song, Kun-Ho;Youn, Hwa-Young;Seo, Kyoung-Won
    • Journal of Veterinary Clinics
    • /
    • v.34 no.2
    • /
    • pp.65-69
    • /
    • 2017
  • Thromboembolic complications are increasing in veterinary medicine. Thromboelastography (TEG) is a more comprehensive method for assessing the clotting process than standard plasma-based coagulation tests. This study compared the ability of TEG and standard coagulation tests to analyze the overall hemostatic state of dogs. The study involved 40 dogs with underlying diseases that predispose to hypercoagulability, including neoplasia, hyperadrenocorticism, immune-mediated diseases, gastrointestinal diseases, and protein-losing nephropathies and enteropathies, and 20 healthy dogs. Their overall hemostatic functional state was evaluated by TEG and routine coagulation assays, including activated partial thromboplastin time, prothrombin time, platelet count, and D-dimer concentration. TEG analysis showed significant differences in clot formation time, ${\alpha}$ angle, and maximum amplitude (MA) between diseased and control dogs (P < 0.001 each). Increased MA was the most frequent abnormality on TEG and was indicative of hypercoagulability. TEG was useful in detecting hemostatic dysfunction in dogs with diseases associated with hypercoagulability. Dogs with TEG tracings indicative of hypercoagulability are likely to be in procoagulant states. Future prospective studies are needed to evaluate whether TEG tracings indicative of hypercoagulability are predictive of thrombosis in dogs.