• 제목/요약/키워드: helium pressure

검색결과 180건 처리시간 0.026초

부피법을 이용한 고압·극저온 수소 흡착량 측정 방식의 기본 원리 (Volumetric Hydrogen Sorbent Measurement at High Pressure and Cryogenic Condition - Basic Measurement Protocols)

  • 오현철
    • 한국수소및신에너지학회논문집
    • /
    • 제27권4호
    • /
    • pp.349-356
    • /
    • 2016
  • Volumetric capacity metrics at cryogenic condition are critical for technological and commercial development. It must be calculated and reported in a uniform and consistent manner to allow comparisons among different materials. In this paper, we propose a simple and universal protocol for the determination of volumetric capacity of sorbent materials at cryogenic condition. Usually, the sample container volume containing porous sample at RT can be directly determined by a helium expansion test. At cryogenic temperatures, however, this direct helium expansion test results in inaccurate values of the sample container volume for microporous materials due to a significant helium adsorption, resulting significant errors in hydrogen uptake. For reducing this container volume error, therefore, we introduced and applied the indirect method such as 'volume correction using a non-porous material', showing a reliable cold volume correction.

Collins 내동기의 최적 설계조건 (Optimum Design Condition of the Collins Cryocooler)

  • 이상원;김수연;정평석
    • 설비공학논문집
    • /
    • 제4권3호
    • /
    • pp.183-190
    • /
    • 1992
  • The Collins cryocooler is numerically analysed with the optimization technique, and the optimum operating and design conditions are searched. This paper shows that liquefied helium quantity has an external maximum w.r.t. the total mass flow rate, the mass flow rates through expander and the capacities of heat exchangers. The liquefied helium quantity increases as the compressor exit pressure of the cryocooler does. The maximum quantity of liquefied helium and the maximum coefficient of performance have been found to exist in extremum, depending on the ratios of each heat exchanger capicities to the total one. At the optimum condition, the capacity of heat exchanger in high temperature region is larger than that in low temperature region.

  • PDF

950℃ 불순물을 포함한 헬륨 환경에서 CVD β-SiC의 산화 (Oxidation of CVD β-SiC in Impurity-Controlled Helium Environment at 950℃)

  • 김대종;김원주;장지은;윤순길;김동진;박지연
    • 한국세라믹학회지
    • /
    • 제48권5호
    • /
    • pp.426-432
    • /
    • 2011
  • The oxidation behavior of CVD ${\beta}$-SiC was investigated for Very High Temperature Gas-Cooled Reactor (VHTR) applications. This study focused on the surface analysis of the oxidized CVD ${\beta}$-SiC to observe the effect of impurity gases on active/passive oxidation. Oxidation test was carried out at $950^{\circ}C$ in the impurity-controlled helium environment that contained $H_2$, $H_2O$, CO, and $CH_4$ in order to simulate VHTR coolant chemistry. For 250 h of exposure to the helium, weight changes were barely measurable when $H_2O$ in the bulk gas was carefully controlled between 0.02 and 0.1 Pa. Surface morphology also did not change based on AFM observation. However, XPS analysis results indicated that a very small amount of $SiO_2$ was formed by the reaction of SiC with $H_2O$ at the initial stage of oxidation when $H_2O$ partial pressure in the CVD ${\beta}$-SiC surface placed on the passive oxidation region. As the oxidation progressed, $H_2O$ consumed and its partial pressure in the surface decreased to the active/passive oxidation transition region. At the steady state, more oxidation did not observable up to 250 h of exposure.

터보펌프식 액체추진기관에서의 극저온 산화제 탱크 내부 현상 고찰 (Investigation of the Cryogenic Oxidizer Tank Inner Phenomena of Pump-fed Liquid Rocket Engine Propulsion System)

  • 조남경;권오성;정용갑;조인현;김영목;조기주;정영석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제21회 추계학술대회 논문집
    • /
    • pp.238-241
    • /
    • 2003
  • 터보펌프식 기체 공급계의 액체산소 탱크는 저압이 유지됨에 따라 탱크 내에서 추진제의 기화가 활발히 이루어지게 되며, 이러한 경향은 가압 기체의 온도가 높아짐에 따라 커지게 된다. 가압헬륨의 충진량을 결정하기 위해서는 이에 대한 정밀한 해석이 필요하다. 본 연구에서는 탱크내의 유동현상을 이상유동(two phase flow) 형태로 모델링 하여 탱크 내에서의 액체산소의 증발현상에 대하여 고찰하고 가압기체 온도 및 표면 열전달 계수에 따른 필요 헬륨 가스량을 예측한다.

  • PDF

KSTAR 저온헬륨설비 시운전 결과 (Commissioning results of the KSTAR helium refrigeration system)

  • 조광운;장현식;박동성;주재준;문경모;김양수;박주식;양승한;에릭포브
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권1호
    • /
    • pp.64-68
    • /
    • 2009
  • To keep the superconducting (SC) magnet coils of KSTAR at proper operating conditions, not only the coils but also other cold components, such as thermal shields (TS), magnet structures, SC bus-lines (BL), and current leads (CL) must be maintained at their respective cryogenic temperatures. A helium refrigeration system (HRS) with an exergetic equivalent cooling power of 9kW at 4.5K without liquid nitrogen $(LN_2)$ pre-cooling has been manufactured and installed for such purposes. In this proceeding, we will present the commissioning and initial operation results of the KSTAR HRS. Circuits which can simulate the thermal loads and pressure drops corresponding to the cooling channels of each cold component of KSTAR have been integrated into the helium distribution system of the HRS. Using those circuits, the performance and the capability of the HRS, to fulfill the mission of establishing the appropriate operating condition for the KSTAR SC magnet coils, have been successfully demonstrated.

상용 헬륨압축기를 이용한 네온 냉각 시스템의 냉각특성 실험 (Cooling performance test of neon refrigeration system using commercial helium compressor)

  • 고준석;김효봉;염한길;홍용주;박성제;이공훈
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권3호
    • /
    • pp.36-41
    • /
    • 2011
  • This paper describes experimental investigation on neon refrigeration system using commercial helium compressor. In this paper, neon refrigeration cycle is calculated with assumption of ideal heat exchanger. From analysis, 32.6 K of the lowest temperature and 0.945 of quality after expansion are predicted. Cryogenic heat exchangers for pre cooler and main heat exchanger are designed and fabricated with configuration of tube-in-tube heat exchanger. In experiments, cooling performance test are performed as variation of charging pressure and orifice hole diameter. From experimental results, the lowest temperature of 44.0 K was measured with 500 ${\mu}m$ orifice and 1500 kPa of charging pressure.

Decomposition of Biological Macromolecules by Plasma Generated with Helium and Oxygen

  • Kim Seong-Mi;Kim Jong-Il
    • Journal of Microbiology
    • /
    • 제44권4호
    • /
    • pp.466-471
    • /
    • 2006
  • In this study, we attempted to characterize the biomolecular effects of an atmospheric-pressure cold plasma (APCP) system which utilizes helium/oxygen $(He/O_2)$. APCP using $He/O_2$ generates a low level of UV while generating reactive oxygen radicals which probably serve as the primary factor in sterilization; these reactive oxygen radicals have the advantage of being capable to access the interiors of the structures of microbial cells. The damaging effects of plasma exposure on polypeptides, DNA, and enzyme proteins in the cell were assessed using biochemical methods.

증기발생기 세관 수압확관부 비파괴검사 방법론 (Methodology of Non-Destructive Examinations on Hydraulic Expansion Region of Steam Generator Tubes)

  • 김창수;정남두;이상훈
    • 한국압력기기공학회 논문집
    • /
    • 제4권2호
    • /
    • pp.29-33
    • /
    • 2008
  • As the measures of nuclear power plant utilities and manufacturers to reduce the defects of tube expansion region during manufacturing steam generators, many types of NDEs(Non-Destructive Examinations) are conducted to inspect the expansion region. The expansion region of tube is subject to degrade because of stress concentration induced by tube expansion, sludge pile and high temperature. So the inspections for tube expansion region have been reinforced. Liquid penetrant test, helium leak test, Bobbin profile test and hydraulic test are performed to confirm the integrity of tube expanded by hydraulic expansion method. Liquid penetrant test and helium leak test are used to inspect seal weld region on tubesheet end part. Bobbin Profile test is used to inspect fully the expanded region of steam generator tube. Hydraulic test finally verifies the integrity of seal weld region on tubesheet end part.

  • PDF

Helium/Oxygen Atmospheric Pressure Plasma Treatment on Poly(ethylene terephthalate) and Poly(trimethylene terephthalate) Knitted Fabrics: Comparison of Low-stress Mechanical/Surface Chemical Properties

  • Hwang Yoon Joong;McCord Marian G.;Kang Bok Choon
    • Fibers and Polymers
    • /
    • 제6권2호
    • /
    • pp.113-120
    • /
    • 2005
  • Helium-oxygen plasma treatments were conducted to modify poly(trimethylene terephthalate) (PIT) and poly(ethylene terephthalate) (PET) warp knitted fabrics under atmospheric pressure. Lubricant and contamination removals by plasma etching effect were examined by weight loss $(\%)$ measurements and scanning electron microscopy (SEM) analysis. Surface oxidation by plasma treatments was revealed by x-ray photoelectron spectroscopy (XPS) analyses, resulting in formation of hydrophilic groups and moisture regain $(\%)$ enhancement. Low-stress mechanical properties (evaluated by Kawabata evaluation system) and bulk properties (air permeability and bust strength) were enhanced by plasma treatment. Increasing interfiber and interyarn frictions might play important roles in enhancing surface property changes by plasma etching effect, and then changing low-stress mechanical properties and bulk properties for both fabrics.

산소 농도에 따른 Alloy 617의 고온헬륨환경에서의 크립 및 산화거동 (Creep and Oxidation Behaviors of Alloy 617 in High Temperature Helium Environments with Various Oxygen Concentrations)

  • 구자현;김대종;장창희
    • 한국압력기기공학회 논문집
    • /
    • 제7권2호
    • /
    • pp.34-41
    • /
    • 2011
  • Wrought nickel-base superalloys are being considered as the structural materials in very-high temperature gas-cooled reactors. To understand the effects of impurities, especially oxygen, in helium coolant on the mechanical properties of Alloy 617, creep tests were performed in high temperature flowing He environments with varying $O_2$ contents at 800, 900, and $1000^{\circ}C$. Also, creep life in static He was measured to simulate the pseudo-inert environment. Creep life was the longest in static He, while the shortest in flowing helium. In static He, impurities like $O_2$ and moisture were quickly consumed by oxidation in the early stage of creep test, which prevented further oxidation during creep test. Without oxidation, microstructural change detrimental to creep such as decarburization and internal oxidation were prevented, which resulted in longer creep life. On the other hand, in flowing He environment, surface oxides were not stable enough to act as diffusion barriers for oxidation. Therefore, extensive decarburization and internal oxidation under tensile load contributed to premature failure resulting in short creep life. Limited test in flowing He+200ppm $O_2$ resulted in even shorter creep life. The oxidation samples showed extensive spallation which resulted in severe decarburization and internal oxidation in those environments. Further test and analysis are underway to clarify the relationship between oxidation and creep resistance.