• Title/Summary/Keyword: height function

Search Result 1,110, Processing Time 0.027 seconds

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

Clinical significance of acanthosis nigricans in children and adolescents with obesity induced metabolic complications (비만으로 인한 대사적 합병증을 가진 소아 및 청소년에서 흑색가시세포증의 임상적 의의)

  • Chueh, Hee Won;Cho, Gyu Rang;Yoo, Jaeho
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.10
    • /
    • pp.987-994
    • /
    • 2007
  • Purpose : This study investigated the clinical significance of AN in children and adolescents with obesity induced metabolic complications. Methods : Forty-nine patients who had obesity induced metabolic complications were participated in this cross-sectional study. Obesity induced metabolic complications are as follows: hypertension, dyslipidemia, impaired fasting glucose (IFG), impaired glucose tolerance (IGT), nonalcoholic steatohepatitis (NASH), homeostasis model assessment of insulin resistance (HOMA-IR)>3.16. Clinical characteristics, such as, age, percentage-weight-for-height (PWH), pubertal status, blood pressure (BP), fasting plasma insulin level, fasting and post-oral glucose tolerance test 2-hour glucose levels, liver function test, lipid profile, HOMA-IR were compared according to the presence of AN. Results : Sixty-five percent of patients had AN, 57.1% NASH, 57.1% dyslipidemia, 55.1% hypertension, 46.9% IFG, 24.5% HOMA-IR>3.16 and 16.2% IGT. The patients who were moderately to severely obese with AN had higher incidence of IGT and HOMA-IR>3.16. The patients with AN had significantly higher diastolic BP ($79.4{\pm}6.9$ vs $75.4{\pm}5.6mmHg$), fasting levels of plasma insulin ($10.6{\pm}6.0$ vs $6.2{\pm}5.4{\mu}IU/mL$), HOMA-IR index ($2.6{\pm}1.4$ vs $1.4{\pm}1.3$) and PWH ($42.4{\pm}13.0$ vs $34.3{\pm}1.8%$). The increasing tendency for the presence of AN was significantly related to the cumulative number of obesity induced metabolic complications. Binary logistic regression analysis revealed that the presence of AN was significantly associated with fasting plasma insulin level, PWH and IFG. Conclusion : AN could be useful as a clinical surrogate of obesity induced metabolic complications.

Planting Method of Buffer Green Space in the Reclaimed Seaside Areas, Rokko Island, Kobe, Japan (일본 고베시(신호시(神戶市)) 로코(육갑(六甲))아일랜드 임해매립지의 완충녹지 식재기법 연구)

  • Han, Bong-Ho;Kim, Jong-Yup;Choi, Jin-Woo;Cho, Yong-Hyeon
    • Korean Journal of Environment and Ecology
    • /
    • v.24 no.2
    • /
    • pp.157-165
    • /
    • 2010
  • This study was carried out to suggest the basic data of planting method for construction of buffer green space based on the land use in case of reclaimed land by analyzing land structure, planting concept, and planting structure in buffer green space, Rokko Island, Kobe, Japan. Rokko Island(total area: 580ha) is divided into port and logistics industry area and urban area by constructing the box type large-scale buffer green space. The land structure of buffer green space were biased mounding type, parallel mounding type, and complex mounding type. The width of buffer green space was 50meters in case of northern area, from 28 to 32meters in case of eastern area, and 37.5meters in case of western area, and the slope of that was from 18 to 25 degrees and the height of that was from 2 to 15meters. There were applied landscape and buffer planting concept on the sea side area of northern buffer green space, on the other hand landscape and shade planting concept on the Inner city side area of that. According to the result of planting structure analysis of northern buffer green space, the main woody species were those of deciduous-evergreen species grow in warm-temperate forest zone such as Quercus glauca, Cinnamomum camphora, Machilus thunbergii, Elaeagnus maritima. The results of maximum number of species and planting density by $100mm^2$ was that 9 species 22 individuals in canopy layer, 9 species 15 individuals in understory layer, 3 species 67 individuals in shrub layer, and 14 species 104 individuals in total. The plant coverage of northern buffer green space based on the ecological planting method was from 69 to 139% in case of canopy layer, from 26 to 38% in case of understory layer, from 6 to 7% in case of shrub layer, and from 101 to 184% in total. Index of plant crown volume of northern buffer green space based on the ecological planting method was from 1.40 to $3.12m^3/m^2$ in case of canopy layer, from 0.43 to $0.55m^3/m^2$ in case of understory layer, $0.06m^3/m^2$ in case of shrub layer, and from 1.89 to $3.73m^3/m^2$ in total.

The Effect of Temporary Cement Cleaning Methods on the Retentive Strength of Cementation Type Implant Prostheses (임시 시멘트 제거방법이 시멘트 유지형 임플란트 보철물의 유지력에 미치는 영향)

  • Shin, Hwang-Kyu;Song, Young-Gyun;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.125-140
    • /
    • 2011
  • The remnant of temporary cement on the intaglio surface of cast restoration may have a negative effect on the retentive strength of permanent cement. This study was to evaluate the effect of temporary cement cleaning methods on the retentive strength of cementation type implant prostheses. Prefabricated implant abutments - height 5.5mm, diameter 4.5mm, 6 degree axial wall taper with chamfer margins were used. Forty copings-abutment specimens were divided into four groups(each n=10) according to the cleaning methods for temporary cement(Temp-$Bond^{(R)}$) as follows : no temporary cementation(the control group), orange solvent, ultrasonic cleaning, air borne-particle abrasion. After the application of temporary cement and the separation, the cleaning procedure was performed according to the protocol of each group. The specimens were cemented with $Premier^{(R)}$ Implant $Cement^{TM}$. After the permanent cementation, the specimens were subjected to thermocycling and pulled out from the specimens with a universal testing machine at a cross-head speed of 0.5mm/min. After the retentive strength test, all the specimens were cleaned using ultrasonic cleaning, abraded with air borne-particles, and steam-cleaned. Likewise, the specimens were temporarily cemented(Temp-$Bond^{(R)}$ NE), cleaned according to the protocol of each group, cemented with $Premier^{(R)}$ Implant $Cement^{TM}$ and subjected to thermocycling and measurement of their retentive strength. The mean of group with orange solvent were significantly lower than those of other groups(p<0.05). There was no significance between group with ultrasonic cleaning and group with air borne-particle abrasion. Group with ultrasonic cleaning and group with air-particle abrasion were no significance at control group. There was no significance between group cemented with Temp-$Bond^{(R)}$ and group cemented with Temp-$Bond^{(R)}$ NE. Within the limitation of this study, it can be concluded that the temporary cement cleaning method with only orange solvent may have a negative effect on the retentive strength of permanent cement. Ultrasonic cleaning and air borne-particle abrasion methods are recommended for the temporary cement cleaning method on cementation type implant prostheses.

Quality Characteristics of Muffins Added with Fucoidan Red Yeast (Monascus purpureus) Rice Powder (푸코이단 홍국쌀 분말을 첨가한 머핀의 품질 특성)

  • Choi, Young Ju;Choi, Kyung Ha;Park, Mi Hwa;Kim, Mi Hwang;Kong, Chang Suk;Kim, Se Won;Jung, Kyung Im
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.11
    • /
    • pp.1358-1365
    • /
    • 2017
  • This study evaluated the quality characteristics of muffins prepared with different amounts (0%, 10%, 20%, 30%, 50%) of fucoidan red yeast (Monascus purpureus) rice powder (FRYR). The weight and pH of muffins increased as the amount of FRYR increased. The height and baking loss rate of muffins significantly decreased when amounts of FRYR increased (P<0.05), whereas moisture content was not significantly different between all samples. L value and b value of muffins significantly decreased when amounts of FRYR increased (P<0.05). However, a value of muffins significantly increased when amounts of FRYR increased (P<0.05). Hardness, chewiness, and brittleness increased with increasing FRYR concentration. Cohesiveness was higher with 30% FRYR, whereas springiness was not significantly different between the samples. In the sensory evaluation, the appearance and crumb color of muffins was higher in groups containing 0% FRYR, whereas flavor, taste, texture, and overall acceptability scores were highest for muffins with 50% FRYR added. The total polyphenol content and 1,1-diphenyl-2-picrylhydrazyl radical scavenging activity of muffins significantly increased with increasing addition of FRYR (P<0.05). Therefore, addition of FRYR could satisfy the sensory function and functional requirements of muffins. Furthermore, this study proposes the development of various products using fucoidan red yeast rice.

SLUMPING TENDENCY AND RHEOLOGICAL PROPERTY OF FLOWABLE COMPOSITES (Flowable 복합레진의 slumping 경향과 유변학적 성질)

  • Lee, In-Bog;Min, Sun-Hong;Kim, Sun-Young;Cho, Byung-Hoon;Back, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.130-136
    • /
    • 2009
  • The aim of this study was to develop a method for measuring the slumping resistance of flowable resin composites and to evaluate the efficacy using rheological methodology. Five commercial flowable composites (Aelitefil flow:AF, Filtek flow:FF, DenFil flow:DF, Tetric flow:TF and Revolution:RV) were used. Same volume of composites in a syringe was extruded on a glass slide using a custom-made loading device. The resin composites were allowed to slump for 10 seconds at $25^{\circ}C$ and light cured. The aspect ratio (height/diameter) of cone or dome shaped specimen was measured for estimating the slumping tendency of composites. The complex viscosity of each composite was measured by a dynamic oscillatory shear test as a function of angular frequency using a rheometer. To compare the slumping tendency of composites, one way-ANOVA and Turkey's post hoc test was performed for the aspect ratio at 95% confidence level. Regression analysis was performed to investigate the relationship between the complex viscosity and the aspect ratio. The results were as follows. 1. Slumping tendency based on the aspect ratio varied among the five materials (AF

Comparison of the Reconstruction Routes after Esophagectomy for Esophageal Cancer (식도암 절제후 식도 재건경로의 비교)

  • Lee, Seung-Yeoll;Kim, Kwang-Taik;Choi, Young-Ho;Kim, Il-Hyun;Baik, Man-Jong;Sun, Kyung;Lee, In-Sung;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.32 no.9
    • /
    • pp.806-812
    • /
    • 1999
  • Background: Selection of reconstruction route in esophageal cancer surgery is based on the patient's status, characteristics of tumor, surgeon's preference and experience. Of the various routes, it has been documented that subcutaneous or substernal route may prolong operation time and may be vulnerable to postoperative respiratory complications. This study was designed to evaluate whether the selection of reconstruction route affects the surgical outcomes. Material and Method: Of 131 patients who have undergone resection and reconstruction for esophageal cancer, posterior mediastinal route(Group I, n=34), substernal route (Group II, n=31), and subcutaneous route(Group III, n=21) were retrospectively reviewed in 86 patients. Results of early operations and morbidities were compared between the groups. Result: There was a male prevalence(79 of males vs. 7 of females). There were 81 squamous cell cancers and 5 adenocarcinomas. There were no differences between groups in weight, height, age, cancer staging and location, and in the preoperative anesthetic risk evaluation and pulmonary function test(p=NS). Postoperative mechanical ventilation time was longer in Group I(20.6 hours) than in Group II(7.8 hours) or III(3.4 hours)(p=0.005). Duration of stay in the intensive care unit was prolonged in Group III(6.4 days) compared to Group I (3.9 days) or II(3.1 days)(p=0.043). No differences were noted in the duration of hospital stay between the groups(p=NS). Blood transfusion was needed in 30 out of 34 patients in Group I compared to 14/31 in Group II or 15/21 in Group III(p=0.001). The mean amount of transfusion for each patient was also higher in Group I(3,833 mL) than in Group II(1535 mL) or Group III(1419 mL)(p=0.04), but there was no difference in the inreoperation due to bleeding. Ea ly mortality rate was substantially higher in Group I(17.6%) but the differences between the groups were insignificant(p=NS). Although sepsis was a more prevalent cause of death in Group I, it was not related to anastomotic leak. Other morbidities did not differ between the groups(p=NS). Conclusion: In above results show that the reconstruction route does not affect the outcome of esophageal cancer surgery. We believe that the selection of reconstruction route can be based on the surgeon's preference and experience.

  • PDF

Debris flow characteristics and sabo dam function in urban steep slopes (도심지 급경사지에서 토석류 범람 특성 및 사방댐 기능)

  • Kim, Yeonjoong;Kim, Taewoo;Kim, Dongkyum;Yoon, Jongsung
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.8
    • /
    • pp.627-636
    • /
    • 2020
  • Debris flow disasters primarily occur in mountainous terrains far from cities. As such, they have been underestimated to cause relatively less damage compared with other natural disasters. However, owing to urbanization, several residential areas and major facilities have been built in mountainous regions, and the frequency of debris flow disasters is steadily increasing owing to the increase in rainfall with environmental and climate changes. Thus, the risk of debris flow is on the rise. However, only a few studies have explored the characteristics of flooding and reduction measures for debris flow in areas designated as steep slopes. In this regard, it is necessary to conduct research on securing independent disaster prevention technology, suitable for the environment in South Korea and reflective of the topographical characteristics thereof, and update and improve disaster prevention information. Accordingly, this study aimed to calculate the amount of debris flow, depending on disaster prevention performance targets for regions designated as steep slopes in South Korea, and develop an independent model to not only evaluate the impact of debris flow but also identify debris barriers that are optimal for mitigating damage. To validate the reliability of the two-dimensional debris flow model developed for the evaluation of debris barriers, the model's performance was compared with that of the hydraulic model. Furthermore, a 2-D debris model was constructed in consideration of the regional characteristics around the steep slopes to analyze the flow characteristics of the debris that directly reaches the damaged area. The flow characteristics of the debris delivered downstream were further analyzed, depending on the specifications (height) and installation locations of the debris barriers employed to reduce the damage. The experimental results showed that the reliability of the developed model is satisfactory; further, this study confirmed significant performance degradation of debris barriers in areas where the barriers were installed at a slope of 20° or more, which is the slope at which debris flows occur.

Photosynthesis of ×Populus albaglandulosa in Relation to Leaf Age (×Populus albaglandulosa의 엽령별(葉齡別) 광합성(光合成))

  • Kim, Chung Suk;Lee, Suk Koo;Sun, Soon Wha
    • Journal of Korean Society of Forest Science
    • /
    • v.34 no.1
    • /
    • pp.63-71
    • /
    • 1977
  • ${\times}$Populus albaglandulosa has been needed optimum stand density according to various site and its wood usage. It is assumed that optimum stand density can be estimated by investigating of response of ${\times}$P. albaglandulosa to the light factor of stand. For that reason, the photosynthesis of ${\times}$Populus albaglandulosa grown under the controlled planting density was studied in relation to its leaf age by the aid of the Infrared gas analyzer. Rate of net photosynthesis was smaller in matured leaves than young leaves below $8^{\circ}C$, while, it was larger than young leaves above $8^{\circ}C$. Temperature for the maximum net photosynthesis of young leaves and old leaves was about $30^{\circ}C$ and $25^{\circ}C$ respectively. Saturated light intensity varied slightly as leaf age from 28 Klux to 35 Klux, but net photosynthesis rate in the range of light intensity showed deep differences. Old leaves marked the lowest rate, $1.6\;CO_2\;mg/dm^2/hr$, young leaves marked the medium rate, 1.7 to $2.2\;CO_2\;mg/dm^2/hr$, and matured leaves marked the most efficient photosynthesis, 2.9 to $3.5\;CO_2\;mg/dm^2/hr$. Young leaves of 5 days old had the highest light compensation point, while matured leaves of 35 days-old had the lowest point. Rates of dark respiration in both young leaves and old leaves were higher than that of matured leaves. Trees which were planted at space $80cm{\times}80cm$ showed productive assimilation function over the one-third of height where relative light intensity is 35%.

  • PDF

A STUDY ON THE JUJEON OF AUTOMATIC CLEPSYDRA IN EARLY JOSEON DYNASTY (조선 전기 자동물시계의 주전(籌箭) 연구)

  • YUN, YONG-HYUN;KIM, SANG HYUK;MIHN, BYEONG-HEE;OH, KYONG TAEK
    • Publications of The Korean Astronomical Society
    • /
    • v.36 no.3
    • /
    • pp.65-78
    • /
    • 2021
  • Jagyeokru, an automatic striking water clock described in the Sejong Sillok (Veritable Records of King Sejong) is essentially composed of a water quantity control device and a time-signal device, with the former controlling the amount or the flow rate of water and the latter automatically informing the time based on the former. What connects these two parts is a signal generating device or a power transmission device called the 'Jujeon' system, which includes a copper rod on the float and ball-racked scheduled plates. The copper products excavated under Gongpyeong-dong in Seoul include a lot of broken plate pieces and cylinder-like devices. If some plate pieces are put together, a large square plate with circular holes located in a zigzag can be completed, and at the upper right of it is carved 'the first scheduled plate (一箭).' Cylinder-like devices generally 3.8 cm in diameter are able to release a ball, and have a ginkgo leaf-like screen fixed on the inner axis and a bird-shaped hook of which the leg fixes another axis and the beak attaches to the leaf side. The lateral view of this cylinder-like device appears like a trapezoid and mounts an iron ball. The function of releasing a ball agrees with the description of Borugak Pavilion, where Jagyeokru was installed, written by Kim Don (1385 ~ 1440). The other accounts of Borugak Pavilion's and Heumgyeonggak Pavilion's water clocks describe these copper plates and ball releasing devices as the 'Jujeon' system. According to the description of Borugak Pavilion, a square wooden column has copper plates on the left and right sides the same height as the column, and the left copper plate has 12 drilled holes to keep the time of a 12 double-hours. Meanwhile, the right plate has 25 holes which represent seasonal night 5-hours (Kyeong) and their 5-subhours (Jeom), not 12 hours. There are 11 scheduled plates for seasonal night 5-hours made with copper, which are made to be attached or detached as the season. In accordance with Nujutongui (manual for the operation of the yardstick for the clepsydra), the first scheduled plate for the night is used from the winter solstice (冬至) to 2 days after Daehan (大寒), and from 4 days before Soseol (小雪) to a day before the winter solstice. Besides the first scheduled plate, we confirm discovering a third scheduled plate and a sixth scheduled plate among the excavated copper materials based on the spacing between holes. On the other hand, the width of the scheduled plate is different for these artifacts, measured as 144 mm compared to the description of the Borugak Pavilion, which is recorded as 51 mm. From this perspective, they may be the scheduled plates for the Heumgyeonggak Ongru made in 1438 (or 1554) or for the new Fortress Pavilion installed in Changdeokgung palace completed in 1536 (the 31st year of the reign of King Jungjong) in the early Joseon dynasty. This study presents the concept of the scheduled plates described in the literature, including their new operating mechanism. In addition, a detailed model of 11 scheduled plates is designed from the records and on the excavated relics. It is expected that this study will aid in efforts to restore and reconstruct the automatic water clocks of the early Joseon dynasty.