• 제목/요약/키워드: height Accuracy

검색결과 738건 처리시간 0.026초

A Study on Computing Pit Excavation Volume by Terrain Surface Approximation (지형곡면해석에 의한 토공량 계산에 관한 연구)

  • 문두열;정범석
    • Journal of Ocean Engineering and Technology
    • /
    • 제16권6호
    • /
    • pp.37-43
    • /
    • 2002
  • The calculation of earthwork plays a major role in the plan or design phase of many civil engineering projects, such as seashore reclamation; and thus, it has become very important to improve upon its accuracy. There have been common drawbacks to earlier methods of ground profiling, such as dialing with sharp corners or the grid points of any tow straight lines. In this paper, we prepose an algorithm for finding a terrain surface using the natural boundary conditions and the both direction spline method, which interpolates the given three-dimensional data by using spline. As a result of this study, the algorithm of the proposed two methods to estimate pit excavation volume should provide a better accuracy than Spot height, Chambers, Chen, or Lin method. Also, the mathematical model mentioned offers maximum accuracy in estimating the volume of a pit excavation.

Accuracy Assessment of DTM by Airborne Laser Mapping System (항공 레이저 매핑 시스템에 의한 DTM 생성의 정확도 분석)

  • 김영배;서정헌;임삼성
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • 제20권2호
    • /
    • pp.105-110
    • /
    • 2002
  • For the accuracy assessment of DTM obtained by Airborne Laser Mapping Systems (ALMS), we selected 500 m spaced test points and analyze the accuracy of the DTM by various methods including GPS survey. To estimate the height at the point in between the test points of the DTM we produced a TIN, and to analyze the accuracy we use a GPS coverage map overlaid with the TIN. Compared with the existing method, DTM by ALMS is shown to be relatively accurate, and therefore, ALMS is applicable to 1/5000 digital terrain mapping.

A Study on the Accuracy of Convergent Photographs Using Non-Metric Camera (비측량용 사진기에 의한 수렴사진의 정확도에 관한 연구)

  • Yeu, Bock-Mo;Kwon, Hyon;Yu, Ki-Yun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • 제7권2호
    • /
    • pp.63-68
    • /
    • 1989
  • This study was to develope the methmatic prediction model of accuracy for the convergent photographs using nonmetric camera in close range photogrammetry. By analyzing positioning error on object distance and convergent angles, the validity of the new formulae for prediction of accuracy were proved. Rational design of camera systems and convergent angles according to accuracy demands in plane and height were developed using these formulae.

  • PDF

Development of Algorithm for Prediction of Bead Height on GMA Welding (GMA 용접의 최적 비드 높이 예측 알고리즘 개발)

  • 김인수;박창언;김일수;손준식;안영호;김동규;오영생
    • Journal of Welding and Joining
    • /
    • 제17권5호
    • /
    • pp.40-46
    • /
    • 1999
  • The sensors employed in the robotic are welding system must detect the changes in weld characteristics and produce the output that is in some way related to the change being detected. Such adaptive systems, which synchronise the robot arm and eyes using a primitive brain will form the basis for the development of robotic GMA(Gas Metal Arc) welding which increasingly higher levels of artificial intelligence. The objective of this paper is to realize the mapping characteristics of bead height through learning. After learning, the neural estimation can estimate the bead height desired from the learning mapping characteristic. The design parameters of the neural network estimator(the number of hidden layers and the number of nodes in a layer) are chosen from an estimation error analysis. A series of bead of bead-on-plate GMA welding experiments was carried out in order to verify the performance of the neural network estimator. The experimental results show that the proposed neural network estimator can predict the bead height with reasonable accuracy and guarantee the uniform weld quality.

  • PDF

A study on the embossing Height displacement of high speed press bottom point accordance (High Speed Press 하사점 변화에 따른 엠보싱 높이 변화 연구)

  • Kim, Seung-Soo;Kim, Sei-Whan;Lee, Chun-Kyu
    • Design & Manufacturing
    • /
    • 제10권2호
    • /
    • pp.29-33
    • /
    • 2016
  • Production machines have been more important, due to quality level of vehicle motor core is getting higher. That is why, to improve assembly fit of tooling and to be emphasized how much moving down caused of deterioration of high speed press, it is also getting more important parts as solution of problems. To analyze how much move based on condition of movement as tooling and high speed press, and to measure how much impact to embossing height caused of changing movement down. As the result of investigation, in case of material thickness 0.5mm, there is highest pull and force power when emboss height is 0.45mm. If emboss height is less than 0.45mm, pull and force power is getting lower, if emboss height is higher than 0.45mm, it is impossible to make it forming caused of changed press movement, also it has been piercing.

A Comparative Study of Wave Height around Ulleungdo using the Radar (레이더식 파랑계를 이용한 울릉도 주변해역 파고 비교분석)

  • Kim, Chang-Su;Kim, Hyun-Soo;Park, Dong-Woo;Yang, Young-Jun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 한국항해항만학회 2019년도 춘계학술대회
    • /
    • pp.119-120
    • /
    • 2019
  • In order to verify the accuracy of wave measurement of the wave instrumentation system using X-band navigation radar, The validity of the results was obtained by analyzing the significant wave height around Ulleungdo. Especially, The correlations between the radar, wave height buoy and marine buoy for wave measurements were analyzed in season.

  • PDF

Comparison of Orthophotos and 3D Models Generated by UAV-Based Oblique Images Taken in Various Angles

  • Lee, Ki Rim;Han, You Kyung;Lee, Won Hee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • 제36권3호
    • /
    • pp.117-126
    • /
    • 2018
  • Due to intelligent transport systems, location-based applications, and augmented reality, demand for image maps and 3D (Three-Dimensional) maps is increasing. As a result, data acquisition using UAV (Unmanned Aerial Vehicles) has flourished in recent years. However, even though orthophoto map production and research using UAVs are flourishing, few studies on 3D modeling have been conducted. In this study, orthophoto and 3D modeling research was performed using various angle images acquired by a UAV. For orthophotos, accuracy was evaluated using a GPS (Global Positioning System) survey that employed VRS (Virtual Reference Station) acquired checkpoints. 3D modeling was evaluated by calculating the RMSE (Root Mean Square Error) of the difference between the outline height values of buildings obtained from the GPS survey to the corresponding 3D modeling height values. The orthophotos satisfied the acceptable accuracy of NGII (National Geographic Information Institute) for a 1/500 scale map from all angles. In the case of 3D modeling, models based on images taken at 45 degrees revealed better accuracy of building outlines than models based on images taken at 30, 60, or 75 degrees. To summarize, it was shown that for orthophotos, the accuracy for 1/500 maps was satisfied at all angles; for 3D modeling, images taken at 45 degrees produced the most accurate models.

Effect of slice inclination and object position within the field of view on the measurement accuracy of potential implant sites on cone-beam computed tomography

  • Saberi, Bardia Vadiati;Khosravifard, Negar;Nourzadeh, Alireza
    • Imaging Science in Dentistry
    • /
    • 제50권1호
    • /
    • pp.37-43
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the accuracy of linear measurements in the horizontal and vertical dimensions based on object position and slice inclination in cone-beam computed tomography (CBCT) images. Materials and Methods: Ten dry sheep hemi-mandibles, each with 4 sites (incisor, canine, premolar, and molar), were evaluated when either centrally or peripherally positioned within the field of view (FOV) with the image slices subjected to either oblique or orthogonal inclinations. Four types of images were created of each region: central/cross-sectional, central/coronal, peripheral/cross-sectional, and peripheral/coronal. The horizontal and vertical dimensions were measured for each region of each image type. Direct measurements of each region were obtained using a digital caliper in both horizontal and vertical dimensions. CBCT and direct measurements were compared using the Bland-Altman plot method. P values <0.05 were considered to indicate statistical significance. Results: The buccolingual dimension of the incisor and premolar areas and the height of the incisor, canine, and molar areas showed statistically significant differences on the peripheral/coronal images compared to the direct measurements (P<0.05). Molar area height in the central/coronal slices also differed significantly from the direct measurements (P<0.05). Cross-sectional images of either the central or peripheral position had no marked difference from the gold-standard values, indicating sufficient accuracy. Conclusion: Peripheral object positioning within the FOV in combination with applying an orthogonal inclination to the slices resulted in significant inaccuracies in the horizontal and vertical measurements. The most undesirable effect was observed in the molar area and the vertical dimension.

A COMPARATIVE STUDY ON THE ACCURACY OF IMPRESSION METHOD USING ADDITION SILICONE PUTTY IMPRESSION MATERIAL (부가중합형 Silicone putty 인상재를 이용한 인상채득 방법의 정확성에 관한 연구)

  • Je, Hong-Ji;Jeong, Chang-Mo;Jeon, Young-Chan;Hwang, Hie-Seong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제34권2호
    • /
    • pp.373-383
    • /
    • 1996
  • In order to compare the accuracy of impression method using addition silicone putty impression material, metal master die was fabricated with 4 cylindrical abutments that were similar in shape to mandibular arch. Among the 4 abutments, two(A, D) with 8mm width and 7mm height were formed in the 2nd molar regions and the other two(B, C) with 6mm width and 7mm height were on the canine regions. Impressions were taken using one-step putty wash impression technique and two-step putty wash impression technique by three different types of impression materials(Perfect, Express, Exaflex). Upon measuring the distance between the abutments on the model by three dimensional measuring machine, the percent of devitaion of the materials were obtained, rendering the following results. The results obtained are as follows : 1. There was no significant difference in accuracy in regard with the impression method between one-step putty wash impression technique and two-step putty wash impression technique using addition silicone putty impression material. 2. There were no difference in accuracy among with three different addition silicone putty impression materials. 3. All the distances between abutments on improved stone models increased in comparison with those on the metal master model.

  • PDF

Numerical Simulation of Irregular Waves Over a Shoal Using Parabolic Wave Model (포물형 파랑모형을 이용한 수중천퇴상 불규칙파의 수치모의)

  • 윤성범;이정욱;연영진;최병호
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • 제13권2호
    • /
    • pp.158-168
    • /
    • 2001
  • A numerical model based on the wide-angle parabolic approximation equation is developed for the accurate simulation of the directional spreading and partial breaking of irregular waves. This model disintegrates the irregular waves into a series of monochromatic wave components, and the simultaneous calculations are made for each wave component. Then, the computed wave components are superposed to get the wave height of irregular waves. To consider the partial breaking of irregular waves in the computation the amount of energy dissipation due to breaking is estimated using the superposed wave height. The accuracy of the developed model is tested by comparing the numerical results with the experimental measurements reported earlier. In the case of non-breaking waves a considerable accuracy of the model is observed for both regular and irregular waves. On the contrary it is found that the accuracy is significantly degenerated for the case of breaking waves. Some analyses for the accuracy degeneration are presented.

  • PDF