• 제목/요약/키워드: heavy ion beam

검색결과 69건 처리시간 0.029초

Hybrid model-based and deep learning-based metal artifact reduction method in dental cone-beam computed tomography

  • Jin Hur;Yeong-Gil Shin;Ho Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.2854-2863
    • /
    • 2023
  • Objective: To present a hybrid approach that incorporates a constrained beam-hardening estimator (CBHE) and deep learning (DL)-based post-refinement for metal artifact reduction in dental cone-beam computed tomography (CBCT). Methods: Constrained beam-hardening estimator (CBHE) is derived from a polychromatic X-ray attenuation model with respect to X-ray transmission length, which calculates associated parameters numerically. Deep-learning-based post-refinement with an artifact disentanglement network (ADN) is performed to mitigate the remaining dark shading regions around a metal. Artifact disentanglement network (ADN) supports an unsupervised learning approach, in which no paired CBCT images are required. The network consists of an encoder that separates artifacts and content and a decoder for the content. Additionally, ADN with data normalization replaces metal regions with values from bone or soft tissue regions. Finally, the metal regions obtained from the CBHE are blended into reconstructed images. The proposed approach is systematically assessed using a dental phantom with two types of metal objects for qualitative and quantitative comparisons. Results: The proposed hybrid scheme provides improved image quality in areas surrounding the metal while preserving native structures. Conclusion: This study may significantly improve the detection of areas of interest in many dentomaxillofacial applications.

중이온 빔 조사에 의한 담배의 돌연변이 유도와 내염성 식물의 선발 (Mutation Induction and Selection of Salt-tolerant Plants by Heavy-ion Beam Irradiation in Tobacco Proembryo)

  • 배창휴;;민경수;김동철;정재성;이춘환;임용표;이효연
    • 식물조직배양학회지
    • /
    • 제25권2호
    • /
    • pp.103-107
    • /
    • 1998
  • 중이온 빔을 이용한 방사선 돌연변이의 기초자료를 얻고자 담배의 수분ㆍ수정 직후의 원배에 100 Gy의 중이온빔을 조사하여 $\textrm{M}_{1}$세대의 종자를 얻었다. NaCl 20과 25%를 포함된 MS배지에 $\textrm{M}_{1}$세대의 종자를 파종하여 17개통의 NaCl저항성 식물체를 선발하였다. 저항성 식물체는 BY-4품종에 $^{14}\textrm{N}$빔을 조사한 처리구에서만 관찰되었다. $\textrm{M}_{1}$세대의 저항성 식물체의 경우 영양생장기간 중에는 외형적 변이가 관찰되지 않았으나 생식생장기의 화기에 있어서는 다양한 변이가 관찰되었다. 특히 암술 수술의 길이의 변화, 꽃잎의 변화, 불완전 화분립, 줄기당 꽃의 착생수 감소 등의 변이가 발생하였다. $\textrm{M}_{1}$세대에서 17개의 NaCl저항성 계통 중에서 8계통은 $\textrm{M}_{2}$ 세대에도 저항성형질이 발현되었고, 또한 $\textrm{M}_{2}$세대의 3계통은 Mannitol이 포함된 배지에서 저항성을 보여주었다.

  • PDF

Numerical optimization of transmission bremsstrahlung target for intense pulsed electron beam

  • Yu, Xiao;Shen, Jie;Zhang, Shijian;Zhang, Jie;Zhang, Nan;Egorov, Ivan Sergeevich;Yan, Sha;Tan, Chang;Remnev, Gennady Efimovich;Le, Xiaoyun
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.666-673
    • /
    • 2022
  • The optimization of a transmission type bremsstrahlung conversion target was carried out with Monte Carlo code FLUKA for intense pulsed electron beams with electron energy of several hundred keV for maximum photon fluence. The photon emission intensity from electrons with energy ranging from 300 keV to 1 MeV on tungsten, tantalum and molybdenum targets was calculated with varied target thicknesses. The research revealed that higher target material element number and electron energy leads to increased photon fluence. For a certain target material, the target thickness with maximum photon emission fluence exhibits a linear relationship with the electron energy. With certain electron energy and target material, the thickness of the target plays a dominant role in increasing the transmission photon intensity, with small target thickness the photon flux is largely restricted by low energy loss of electrons for photon generation while thick targets may impose extra absorption for the generated photons. The spatial distribution of bremsstrahlung photon density was analyzed and the optimal target thicknesses for maximum bremsstrahlung photon fluence were derived versus electron energy on three target materials for a quick determination of optimal target design.

X-Ray Absorption Spectroscopic Study of 120 MeV $Ag^{9+}$ Ion-Irradiated N-Doped ZnO Thin Films

  • Gautam, Sanjeev;Lim, Weon Cheol;Kang, Hee Kyung;Lee, Ki Soo;Song, Jaebong;Song, Jonghan;Asokan, K.;Chae, Keun Hwa
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.315-315
    • /
    • 2013
  • We report the electronic structure modification in the swift heavy ion (SHI) irradiated N-doped ZnO thin films prepared by RF sputtering from ZnO target in different ratio of Ar/$N_2$ gas mixture using highly pure $N_2$ gas. The different N-ZnO thin lms were then irradiated with 120 MeV Ag ion beam with different doses ranging from $1{\times}10^{11}$ to $5{\times}10^{12}$ ions/$cm^2$ and characterized by XRD and near edge X-ray absorption ne structure (NEXAFS) at N and O K-edges. The NEXAFS measurements provide direct evidence of O 2p and Zn 3d orbital hybridization and also the bonding of N ions with Zn and O ions. The minimum value of resistivity of $790{\Omega}cm$, a Hall mobility of $22cm^2V^-1s^-1$ and the carrier concentration of $3.6{\times}10^{14}cm^{-3}$ were yielded at 75% $N_2$. X-ray diffraction (XRD) measurements revealed that N-doped ZnO films had the preferential orientation of (002) plane for all samples, while crystallinity start decreasing at 32.5% $N_2$. The average crystallite size varies from 5.7 to 8.2 nm for 75% and then decreases to 7.8 nm for 80% $Ar:N_2$ ratio.

  • PDF

Setup and Atomic Calibration of Particle Induced X-ray Emission System

  • 송진호;송재봉;존일리야스;김준곤
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.206.2-206.2
    • /
    • 2014
  • Recently, particle induced X-ray emission (PIXE) analysis system was installed at the 2MV ion acceleration system in Korea institute science and technology (KIST). This installation is for complement to low atomic resolution of heavy atoms at Rutherford backscattering spectrometry (RBS) system. For quantitative analysis, a mass calibration of the PIXE set-up has been done with thin film standards and. The GUPIX software package has been used to process the PIXE spectra and the results are compared with the values from RBS system. Therefore, the instrumental constant H (solid angle and correction factor) is determined relying completely on the GUPIX data base (cross-sections, fluorescence and Coster-Kronig probabilities, stopping powers and attenuation coefficients) for a large set of elements. These H values can be used in future analysis.

  • PDF

Formation of Alumian gradient coatings by Ion Beam Assistant Deposition

  • Xue-Jianming
    • 한국진공학회지
    • /
    • 제7권s1호
    • /
    • pp.118-122
    • /
    • 1998
  • $Al_2O_x$(0$Al_2O_3$ gradient coatings were formed by evaporating pure aluminium(99.9%) in $O_2$ environment with an IBAD facility, 12keV $Ar^+$ was used to irradiate the coatings simultaneously during the deposition. Sample's composition and depth profile were analysed by RBS and AES measurement, and their microhardness and porosity property were also measured in the experiment. Results show that, the oxygen concentration in the deposited coatings has a nearly linear relationship with the inputting gas flow before $O_2$ partial pressure in the target chamber reaches $1.2\times10^{-3}$ mbar under which stoichiometric $Al_2O_3$ could be formed; and sample's microhardness and porosity property is affected significantly by the oxygen concentration in the coatings.

  • PDF

Scattering of Noble Gas Ions from a Si(100) Surface at Hyperthermal Energies (20-300 eV)

  • 이현우;Kang, H.
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권2호
    • /
    • pp.101-104
    • /
    • 1995
  • In an attempt to understand the nature of hyperthermal ion-surface collisions, noble gas ion beams (He+, Ne+, Ar+, and Xe+) are scattered from a Si(100) surface for collision energies of 20-300 eV and for 45°incidence angle. The scattered ions are mass-analyzed using a quadrupole mass spectrometer and their kinetic energy is measured in a time-of-flight mode. The scattering event for He+ and Ne+ can be approximated as a sequence of quasi-binary collisions with individual Si atoms for high collision energies (Ei > 100 eV), but it becomes of a many-body nature for lower energies, Ar+ and Xe+ ions undergo mutliple large impact parameter collisions with the surface atoms. The effective mass of a surface that these heavy ions experience during the collision increases drastically for low beam energies.

Estimation of Relative Biological Effectiveness for Carbon Beam

  • Onizuka, Y.;Endo, S.;Takada, M.;Ishikawa, M.;Hoshi, M.;Uehara, S.;Hayabuchi, N.;Maeda, N.;Shizuma, K.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.219-221
    • /
    • 2002
  • In this work, single event spectra were measured in order to gain the microdosimetric parameters of some heavy ion radiotherapy fields at HIMAC. Microdosimetry is now a well-established technique for the investigation of complex mixed radiation field. Changes in frequency mean lineal energy y$\_$F/ as a function of thickness of A150 phantom were obtained. The absorbed dose was obtained by using y$\_$F/. A direct relation between this single event probability distribution and relative biological effectiveness (RBE) was assumed in order to estimate RBE using the response function.

  • PDF

Calibration of TEPC for CubeSat Experiment to Measure Space Radiation

  • Nam, Uk-Won;Park, Won-Kee;Lee, Jaejin;Pyo, Jeonghyun;Moon, Bong-Kon;Lee, Dae-Hee;Kim, Sunghwan;Jin, Ho;Lee, Seongwhan;Kim, Jungho;Kitamura, Hisashi;Uchihori, Yukio
    • Journal of Astronomy and Space Sciences
    • /
    • 제32권2호
    • /
    • pp.145-149
    • /
    • 2015
  • A newly designed Tissue Equivalent Proportional Counter (TEPC) has been developed for the CubeSat mission, SIGMA (Scientific cubesat with Instruments for Global Magnetic field and rAdiation) to investigate space radiation. In order to test the performance of the TEPC, we have performed heavy ion beam experiments with the Heavy Ion Medical Accelerator in Chiba (HIMAC), Japan. In space, human cells can be exposed to complex radiation sources, such as X-ray, Gamma ray, energetic electrons, protons, neutrons and heavy charged particles in a huge range of energies. These generate much a larger range of Linear Energy Transfer (LET) than on the ground and cause unexpected effects on human cells. In order to measure a large range of LET, from 0.3 to $1,000keV/{\mu}m$, we developed a compact TEPC which measures ionized particles produced by collisions between radiation sources and tissue equivalent materials in the detector. By measuring LET spectra, we can easily derive the equivalent dose from the complicated space radiation field. In this HIMAC experiment, we successfully obtained the linearity response for the TEPC with Fe 500 MeV/u and C 290 MeV/u beams and demonstrated the performance of the active radiation detector.

Comparison analysis of superconducting solenoid magnet systems for ECR ion source based on the evolution strategy optimization

  • Wei, Shaoqing;Lee, Sangjin
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권2호
    • /
    • pp.36-40
    • /
    • 2015
  • Electron cyclotron resonance (ECR) ion source is an essential component of heavy-ion accelerator. For a given design, the intensities of the highly charged ion beams extracted from the source can be increased by enlarging the physical volume of ECR zone [1]. Several models for ECR ion source were and will be constructed depending on their operating conditions [2-4]. In this paper three simulation models with 3, 4 and 6 solenoid system were built, but it's not considered anything else except the number of coils. Two groups of optimization analysis are presented, and the evolution strategy (ES) is adopted as an optimization tool which is a technique based on the ideas of mutation, adaptation and annealing [5]. In this research, the volume of ECR zone was calculated approximately, and optimized designs for ECR solenoid magnet system were presented. Firstly it is better to make the volume of ECR zone large to increase the intensity of ion beam under the specific confinement field conditions. At the same time the total volume of superconducting solenoids must be decreased to save material. By considering the volume of ECR zone and the total length of solenoids in each model with different number of coils, the 6 solenoid system represented the highest coil performance. By the way, a certain case, ECR zone volume itself can be essential than the cost. So the maximum ECR zone volume for each solenoid magnet system was calculated respectively with the same size of the plasma chamber and the total magnet space. By comparing the volume of ECR zone, the 6 solenoid system can be also made with the maximum ECR zone volume.