• 제목/요약/키워드: heating temperature and time

검색결과 1,375건 처리시간 0.029초

히팅카고 응고사고 분석 - 나일브렌드를 중심으로 - (An Analyse for Solidified Accident of Nile Blend Crude Oil)

  • 김영모;이옥용
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2002년도 추계학술발표회
    • /
    • pp.59-70
    • /
    • 2002
  • A heating cargo is solidified by several reasons during carnage. This study is to analyse a cargo accident which 811, 202 US barrels of Nile Blend crude oil reamined solid in the tanks after discharge. There are some possibilities that low temperature of loading cargo below cloud point and wax appearance temperature at loading time, heating interruption during voyage or discharging, and prohibition of crude oil washing during discharging might influence the cargo solidified. But we concluded that the defect of heating system would most affect the heating cargo solidified locally, and which blocked drain hole of bottom transverse and web frame and they obstruct flow of heating cargo in the tanks.

  • PDF

바닥난방을 위한 부하 예측식 펄스제어 방식의 적용성 연구 (Application Study of the Predictive Pulse Control for Floor Heating System)

  • 조성환;김성수;김용봉;나희형
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.167-175
    • /
    • 2007
  • A predictive pulse control strategy as a means of improving the energy efficiency of radiant floor heating systems is explored. Experiments at the apartment with floor heating system are conducted to assess and compare the energy performance of the predictive pulse control strategy with an existing conventional control strategy. The Results showed that new suggested PPCM( Predictive Pulse Control Method) was available to decrease the gap of $1{\sim}1.5^{\circ}C$ between maximum and minimum indoor temperature of each rooms. Therefore PPCM method was favor to radiant floor heating system which have a delay time of 10-20 minutes for heat transfer by floor layers.

  • PDF

전화기 케이스 외관의 Weldline 제거를 위한 금형 급속 가열-냉각 기술 개발 (Development of rapid mold heating & cooling technology to remove weldline on surface appearance in telephone case)

  • 차백순;박형필;이상용;김옥래;이승욱;이병옥
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2008년도 추계학술대회 논문집
    • /
    • pp.439-443
    • /
    • 2008
  • Painting process or coating with acrylic film may improve the surface defects of injection molded parts deteriorated by weldlines. flow marks. and etc. However such processes increase the production costs and increase environmental problems. Recently various types of rapid mold heating & cooling technology have been developed in order to improve surface quality of products. In this study. the heating & cooling performance of a telephone case mold is investigated by heat transfer analysis, in which the rapid mold heating & reeling technology is applied. The surface temperature of the mold was measured using thermal image camera and compared with analysis results. The influence of the rapid mold heating & cooling technology on weldline appearance and cycle time increase was also examined.

  • PDF

PTC 전열시트를 사용한 핀-관 열교환기의 제상 특성에 관한 실험적 연구 (An experimental study of defrosting behaviors on the fin-tube heat exchanger with PTC heating sheet)

  • 지성;이관수
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.147-155
    • /
    • 1999
  • In this work, the defrosting characteristics of PTC heating sheet used as a defrosting heat source of fin-tube heat exchanger in a refrigerator have been experimentally compared with those of conventional electric heater. It is found that the characteristics of water draining rate with defrosting time show smoothly oscillating pattern when PTC heating sheet is used, and the drained water is completely melted. The defrosting efficiency of the PTC heating sheet is about 75%, which represents about 25% higher than that of the electric heater. A reduction of defrosting time and an increase of defrosting efficiency may be obtained by improving the arrangement of heating elements of the heating sheet. It is shown that the defrosting time of PTC heating sheet increases linearly with the amount of frost, however the defrosting efficiency is nearly constant. In the application to the refrigerating system, one should notice the fact that the defrosting performance of PTC heating sheet may be defraded due to the repeated operations.

  • PDF

전기로를 활용한 3D 샌드몰드 바인데 제거 시간 검토 (Review of 3D Sandmold Binder Removal Time Using Electric Furnace)

  • 박용규;최병걸;윤주용;최상훈;윤기원;이대식
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.209-210
    • /
    • 2022
  • This research reviewed the status of binder removal depending on the heating temperature and duration by using the 3D sand mold as an electric heating method. In the case of the electric heating method, it was confirmed that a heating temperature of at least 800℃ or higher was required to remove the binder of the 3D sand mold, and the heating duration was confirmed to be about 10 minutes. Afterwards, it is considered necessary to further evaluate the additional binder removal method and the utilization of recycling silica in consideration of economic feasibility and productivity.

  • PDF

태양열 온수 및 난방 일체형 복합시스템의 성능예측 (Performance Prediction of a Hot Water Supply and Panel Heating System with Solar Energy)

  • 한유리;박윤철
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.11-17
    • /
    • 2012
  • In this study, a simulation program was developed with heat transfer model in the thermal storage tank for a solar collector and burner combined heating and hot water supply system. Analysis was conducted with variation of operating condition and schedule to analyze performance of a hot water supply and panel heating system with a solar collector and burner combined thermal storage tank. The simulation program is divided two sections. One part is calculation of temperature variation of water which flows through the panel in the floor for heating of the residential house during 24 hours, and the other part is heat transfer calculation for the reaction time to get desired water temperature in the thermal storage tank. As results, light oil consumption and system performance during operation period were analyzed with variation of climate condition and with or without solar collector. Most of the case, oil could be saved about from 24 to 41% with installing the solar collector. The performance of the system is more dependent on radiation time of the solar collector rather than the intensity of the solar radiation which was adopted for the climate analysis.

난방기 중 이중외피 시스템의 자연환기 성능분석에 관한 실험적 연구 (Experimental Study on Natural Ventilation Performance of Double Facade System in Heating Period)

  • 이건호;김현수;고영우;손영주
    • KIEAE Journal
    • /
    • 제6권2호
    • /
    • pp.43-50
    • /
    • 2006
  • A Double Facade System(DFS) is well known as an innovative solution of ecological facade in the west european countries. There are more than 200 various realized DFS in Germany. At the same time, the korean engineers have researched to find out the physical advantages of DFS in the moderate korean climate, which has a very humid summer with high temperature and a dry winter with low temperature. For example, the monthly mean temperature in Korea comes up to 28K, while that in Germany comes up to only 19K. That is, why a other solution of DFS is needed in Korea. This study has experimented the physical performance of the natural ventilation in the heating period. The preheating function of the cold air by DFS can improve no doubt the performance of the natural ventilation at the cold season as well as spring and autumn. The physical difference between single and double facade on natural ventilation has been tested at the newly constructed laboratory, which can turn $360^{\circ}$ to confirm the characteristic of a facade with the various directions. The results show the natural ventilation of the DFS has definitely much more comfortable than that of the single facade system. The air velocity of the inflow as well as the air temperature in the DFS provide a more stable condition than in the SFS. The theoretical limit(air velocity max 0.2m/s, air temperature min. $18^{\circ}C$, temperature difference between 100mm and 1700mm height max. 3K) on the indoor comfortableness doesn't go over in the DFS. On the other hand, the SFS showed an unstable condition with an excess of comfortableness limit on air velocity as well as temperature. In view of the researching results so far achieved, the research came to a conclusion, that the DFS can provide a more comfortable indoor condition by the preheating in the heating period than a SFS, and the period of natural ventilation in winter time could be definitely increased at the DFS.

지열히트펌프 냉매자동조절에 따른 냉·난방 성능실험에 관한 연구 (A Study on the Cooling Heating Performance Experiment by Refrigerant Auto Control of Geothermal Heat Pump)

  • 구남열;서승일
    • 한국지열·수열에너지학회논문집
    • /
    • 제11권1호
    • /
    • pp.1-6
    • /
    • 2015
  • This study presents analysis of the experimental data meeting conditions of several applications in real time. The results of this experimental study are as follows: Respectively in cooling and heating performance, a refrigerant charge tank can take automatic control of variation of the refrigerant quantity by controling pressure and temperature of system and outlet water temperature. The COP shows 3.5 in cooling operation and 3.2 in heating operation. The refrigerant quantity increases 0.69 kJ/h. When the outdoor temperature decreases $1^{\circ}C$, Therefore if the temperature become lower from $25^{\circ}C$ to $-16^{\circ}C$, the refrigerant quantity increases about 9.5%. Compared to the normal state experiment results, the COP in automatic control of the refrigerant quantity rises roughly 10%.

수술 후 가온방법에 따른 체온과 전율의 변화 (Comparison of Forced Air Warming and Radiant Heating on Body Temperature and Shivering of Post-operative Patients)

  • 최경희
    • 성인간호학회지
    • /
    • 제20권1호
    • /
    • pp.135-148
    • /
    • 2008
  • Purpose: This study compared the effects of forced air warming and radiant heating on body temperature and shivering of patients with postoperative hypothermia. Methods: The quasi-experimental study was conducted with two experimental groups who had surgery under general anesthesia; 20 patients of group 1 experimented with the Bair Hugger as a forced air warming and 20 patients of group 2 experimented with the Radiant heater. The study was performed from July 3 to August 31, 2006 in a recovery room of an university hospital in a city. The effects of the experiment were measured by postoperative body temperature and chilling score at arrival and after every 10 minutes. The data were analyzed by t-test or ${\chi}^2$-test, repeated measures ANCOVA using SPSS/WIN 12.0. Results: The mean body temperature showed differences between the Bair Hugger group and Radiant Heater group at 40 minutes(F=-2.579, p=.034), 50minutes(F=-2.752, p=.027), and 60 minutes(F=-2.470, p=.047) after arrival to the recovery room. So, hypothesis 1 was partially accepted. The mean score of shivering showed differences between the Bair Hugger group and the Radiant Heater group, but it had no significant meaning. Hypothesis 2 was not accepted. Conclusion: We need more study to explore the effects and side effects of heating modalities to select a more effective heat treatment. The efficiency of heat modalities with regards to cost benefit, time consumption, and patients' discomfort such as burns should be considered.

  • PDF

PET 완전배향사의 열처리에 따른 내부구조 변화 (The Microstructural Changes of Heat Set PET Fully Drawn Yarns)

  • 최종명;조길수;김갑진
    • 한국의류학회지
    • /
    • 제11권3호
    • /
    • pp.33-40
    • /
    • 1987
  • PET FDY was heat set at various temperatures and times and the microstructural changes was investigated through crystallinity, birefringence and melting behavior analyses. Crystallinity of heat set PET increased as the treatment temperature and time increased. Birefringence also increased as temperature and time increased. The melting behavior of heat set PET was as follows: In most cases, PET showed double melting peaks. As temperature and time increased, form II crystal became sharp and increased in size, and form I crystal decreased in size. The slower the heating rate, the higher the programmed heating effect during DSC analysis.

  • PDF