• Title/Summary/Keyword: heating load

Search Result 893, Processing Time 0.026 seconds

Improvement Method of Regional Insulation Standard through the Regional Heating Energy Demand Analysis (권역별 난방에너지 요구량 분석을 통한 단열기준 개선방안)

  • Kim, Jeong-Gook;Ahn, Byung-Lip;Jang, Cheol-Yong;Jeong, Hak-Geun;Haan, Chan-Hoon
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.43-48
    • /
    • 2013
  • The effect of climate change has influenced humanity and ecosystem with tremendous changes in temperature. For the past 150 years, the national annual average temperature is 0.6 degree increased and the heating degree day reduced from April to November. However, December to January, the climate change was generated and the heating degree day increased. The blackout occured in 2011 and 2012 by increasing electricity consumption of heating and cooling equipment to the effects of climate change. That is because heating load accounted for 20% of building electric use. In this study, strengthening measures to reduce heating energy consumption is presented due to climate change in winter since 1980 to prevent blackout and reliable power supply for the building energy-saving design standards by Meteorological data provided by the National Weather Service were calculated using the heating degree days in order to present eighteen cities from 1980 to 2012. Insulation standards are presented to prevent black-out by the heating degree days. the heating energy demand was reduced almost 6% including 10% in Central, 5% in South and Jeju area based on strengthening of the insulation. It is applied to the entire country an annual economic effect of 250 billion won, and black-out can be prevented.

A Computer Code for an Optimum Design of Solar Space and Domestic Hot Water Heating System (태양열주택 및 가정용 태양 온수시스템의 설계용 전산코드)

  • Im, D.J.;Chun, M.H.;Yoon, S.B.
    • Solar Energy
    • /
    • v.4 no.2
    • /
    • pp.37-42
    • /
    • 1984
  • A computer code for an optimum design of solar space and domestic hot water heating system has been developed. The f-chart method developed by S.A. Klein et al. has been incorporated in the present computer code. The main conclusions obtained from the present work may be summarized as follows: (1) In Seoul area, about 46% of the total heating load can be obtained from the solar collectors whose total surface area is about one-third of the total heating floor area. (2) In Pusan area, total area of solar collectors should be about half of the total heating floor area in order to obtain an equivalent solar fraction of Seoul. (3) In cheju area, on the other hand, only about 42% of the total heating floor area of solar collectors is needed to get the same solar fraction as in Seoul and Pusan. (4) In order to get the first 50% solar fraction, only about 10-14 collectors ($4'{\times}8'$ collectors) are required, whereas about 48 collectors are needed to obtain the solar fraction of 100%. That is, roughly 3.5-4.5 times greater number of collectors are required to increase the solar fraction from 50% to 100%. Therefore, it can be concluded that it is relatively inefficient and less economical to build a solar system whose solar fraction exceeds more than 50%.

  • PDF

Design Capacity Evaluation of 2-stage Hot Water Heat Exchanger in Apartment Mechanical Rooms with District Heating System (지역난방 공동주택에 설치하는 급탕 2단 열교환기의 용량 적정성 평가에 관한 연구)

  • Chung, Kwang-Seop;Sa, Ki-Yong;Kim, Lae-Hyun;Lee, Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.8
    • /
    • pp.456-461
    • /
    • 2009
  • Recently, an increasing interest in district heating system has emerged rapidly, In this paper, the physical measurements and data to be monitoring through the internet were carried out with regard to hot water heating energy consumption at the three apartment housings with district heating system in Sang-am district of Seoul, Korea, Measurements were made of the thermal factors such as the pressure of heating pipe, flow rates, hot water temperature and etc, The objective of this study is to compare the design capacity of reheat exchanger with that of preheat exchanger in order to evaluate for the number of plates of two exchangers to be distributed properly.

An Experimental Study on the Load Delivery Characteristics of Hybrid Energy System with Geothermal and Solar Heat Sources (지열-태양열원 복합시스템의 부하추종특성에 관한 실험 연구)

  • Hwang, In-Ju;Woo, Nam-Sub
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.2 no.2
    • /
    • pp.1-8
    • /
    • 2006
  • The objective of the present study is to investigate the load delivery characteristics of a hybrid-renewable energy system with geothermal and solar heat sources for hot water, heating and cooling of a residential house in Korea. The hybrid energy system consists of ground source heat pump of 2 RT for cooling with a 150 m vertical U-bend ground heat exchanger, solar collectors of 4.8 m2 and gas fired backup boiler. The averaged coefficient of performance of geothermal module during cooling and heating seasons are evaluated as about 4.5 and 3.8, respectively.

  • PDF

Design Optimization of GaAs Wafer Bonding Module (GaAs 웨이퍼 본딩모듈의 최적화 설계)

  • 지원호;송준엽;강재훈;한승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.860-864
    • /
    • 2003
  • Recently. use of compound semiconductor is widely increasing in the area of LED and RF device. In this study, wafer bonding module is designed and optimized to bond 6 inches device wafer and carrier wafer. Bonding process is performed in vacuum environment and resin is used to bond two wafers. Load spreader and double heating mechanisms are adopted to minimize wafer warpage and void. Structure and heat transfer analyses show the designed mechanisms are very effective in performance improvement.

  • PDF

Experimental Study on the Thermal Performance of a Loop-Type Bidirectional Thermo-Diode System (루프형 양방향 열 다이오드 시스템의 열 성능에 관한 실험적 연구)

  • Chun, Won-Gee;Kim, Sin
    • Solar Energy
    • /
    • v.18 no.2
    • /
    • pp.105-113
    • /
    • 1998
  • In general, the thermo-diode is a device designed to allow heat to be transferred only in one direction. However, the bidirectional thermo-diode devised to change the heat flow in the desired direction can be used for the reduction of the heating load in winter as well as the cooling load in summer. In this study, a solar heating system using loop-type bidirectional thermo-diodes is designed and set up, also it is successfully applied to an outdoor test cell for the verification of its usefulness.

  • PDF

A Development of Coupled Simulation Tool to Evaluate Performance of Ventilation System (환기시스템의 성능평가를 위한 통합 시뮬레이션 Tool의 개발)

  • Cho Wang-Hee;Song Doo-Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.112-121
    • /
    • 2006
  • To evaluate the performance of ventilation system properly, the correlations among the ventilation rate, indoor air-quality and cooling/heating load should be analysed. In this study, simulation tool to analyze the performance of ventilation system was developed. The simulation tool is based on the TRNSYS and some modules to calculate concentration of pollutants with the operation of ventilation system and to decide the signal of ventilation system were newly developed in this study. And these modules coupled with building load and heating/cooling simulation modules. To verify the validity of developed simulation tool, comparison study between simulation and field study were accomplished. As results, the simulation tool developed in this study can be used to predict the performance of ventilation system with accuracy.

A Study on the Assessment of Thermal Performance of Plus50 Eco-building (Plus50 환경공생빌딩의 열성능 평가에 관한 연구)

  • Lee, Hong-Cheol;Hwang, In-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.155-160
    • /
    • 2007
  • This study describes thermal performance of Plus50 eco-building with new technology such as power window system, green wall, structure material, etc. The Plus50 eco-building is house experimental which is constructed by Korea Institute of Construction Technology. In order to estimate thermal performance of the building, TRNSYS program and Prebid, and its sub-modules are used. The results showed that maximum heating and cooling load in the building are calculated at 1st floor and 4th floor, respectively. And also energy saving of the building is calculated as over 30% compared to conventional apartment house.

  • PDF

High Frequency Inverter for Induction Heating with Multi-Resonant Zero Current Switching (다중공진 영전류 스위칭을 이용한 고주파 유도가열용 인버터)

  • Ra, B.H.;Suh, K.Y.;Lee, H.W.;Kim, K.T.
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.38-40
    • /
    • 2002
  • In the case of conventional high frequency inverter, with damage of switch by surge voltage when switch gets into compulsion extinction by load accident and so on because reactor is connected by series to switch, or there was problem of conduction loss by reactor's resistivity component, Also, it has controversial point of that can not ignore conduction loss of switch in complete work kind action of soft switching. In this paper, as high frequency induction heating power supply, we propose half bridge type multi resonance soft switching high frequency inverter topology that can realize high amplitude operation of load current with controlling switch current by multiplex resonance, mitigating surge voltage when switch gets into compulsion extinction and to be complete operation of zero current switching by opposit parallel connected reactor to inverter switch. and do circuit analysis for choice of most suitable circuit parameter of circuit

  • PDF

A Novel Switched Capacitor Lossless Inductors Quasi-Resonant Snubber Assisted ZCS PWM High Frequency Series Load Resonant Inverter

  • Fathy, Khairy;Kang, Tae-Kyung;Kwon, Soon-Kurl;Suh, Ki-Young;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.169-171
    • /
    • 2005
  • In this paper, a novel type of auxiliary switched capacitor assisted edge resonant soft switching PWM series load resonant high frequency inverter with two auxiliary edge resonant lossless inductor snubbers is proposed for small consumer induction heating appliances. The operation principle of this high frequency inverter is described using the switching mode equivalent circuits. The practical effectiveness of the newly proposed soft switching inverter are discussed as compared with the conventional soft switching high frequency inverters based on simulation and experimental results from an application point of view.

  • PDF