• Title/Summary/Keyword: heating information

Search Result 518, Processing Time 0.03 seconds

Thermal Degradation of High Molecular Components Obtained from Pyrolysis of Mixed Waste Plastics (혼합폐플라스틱의 열분해로부터 생성된 고분자성분의 열적분해)

  • Oh, Sea Cheon;Ryu, Jae Hun;Kwak, Hyun;Bae, Seong-Youl;Lee, Kyong-Hwan
    • Applied Chemistry for Engineering
    • /
    • v.19 no.2
    • /
    • pp.191-198
    • /
    • 2008
  • The thermal degradation characteristics of high molecular components obtained from pyrolysis of mixed waste plastics have been studied by thermogravimetric analysis (TGA) and gas chromatography spectrometry (GC-MS). The kinetics of thermal degradation has been studied by a conventional nonisothermal thermogravimetric technique at several heating rates between 10 and $50^{\circ}C/min$. The dynamic thermogravimetric analysis curve and its derivative have been analyzed using a variety of analytical methods reported in the literature to obtain information on the kinetic parameters such as activation energies and reaction orders. The yields of liquid products have been monitored by batch pyrolysis reactor under various reaction temperatures and reaction times. And the characteristic of liquid products with the increase in reaction temperature has been performed by GC-MS.

A Performance Measurement and Evaluation of a 400RT Vertical type Geothermal System installed in a Complex Building Before Occupancy (복합용도 건물에 적용된 400RT급 수직형 지열시스템의 입주전 성능평가)

  • Hwang, Kwang-Il;Shin, Dong-Keol;Kim, Joong-Hun;Shin, Seung-Ho;Jung, Myoung-Kwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.3
    • /
    • pp.7-14
    • /
    • 2008
  • 400RT geothermal system which is the biggest capacity among on-operations at present in Korea is measured and evaluated on 23rd${\sim}$26th Jan. 2008 during those days building is not allowed owners and/or tenants to move in. The geothermal system is consist with vertical-typed 112 geothermal heat exchangers which are installed circle-like 1 row with 4m interval, and has 16 units of 25USRT geothermal-source heat pump(GSHP)s. And each 5 units of circulation pump are running for geothermal heat exchangers and hot water supplies. The followings are the results. The temperatures at G.L. -70m of 2 boreholes are varied quite similarly. The average temperature difference between inlet and outlet of geothermal pipes is $4.1^{\circ}C$, and that of hot water supply is $3.2^{\circ}C$, of Zone 3's each 4 GSHPs when being operated. Despite temperature fluctuations by heating loads, the average temperature difference between main pipes of inlet and outlet of geothermal heat exchangers is measured as $4.1^{\circ}C$. This study propose "Geothermal System COP" which includes not only consumed electric power by compressor but also circulation pumps and auxiliary utilities. By comparing the geothermal system COP with GSHP's performance specification, it is clear that the performances of GHSPs of this site are satisfied with the specification.

The structure analysis of iron relics excavated at dwelling site of Yangsoo-ri (양수리 주거지출토 철제유물의 금속조직과 분석-BC1-AD1 세기 추정 철제유물을 중심으로)

  • Kim, Soo-Ki
    • 보존과학연구
    • /
    • s.27
    • /
    • pp.165-180
    • /
    • 2006
  • The research was conducted to understand type of iron used by those who lived at dwelling site of Yangsoo-ri in between the first century B.C. and the first century A.D. to make steel products and their technique such as steel making process and heat treatment, based on micro structure information obtained through microscopic metallographic structure analysis with SEM-EDS of six steel productsexhumed at the site. Key findings are summarized as below. In the sense that Si-Ca-Al style and less than 0.5% of Ti were found in the non-metallic inclusion, the material used for forged iron ware was magnetite resolved in that. It is, however, unclear whether magnetite was resolved at high temperature or at low temperature. Microscopic structure analysis revealed that forged steel products were made through repeated hot working, the technique of molding by hitting after heating in the process of resolving and molding iron. As a result, the iron used here for the products was not the iron ore which was produced through resolution from discarded cast iron axe, ingot iron. It is probable that to make those steel products, disposed-of cast iron was reused after being molded by decarburizing. Although a few of relics were analyzed for the research, they were of critical importance in defining the process of ironware production from the first century B.C. and the first century A.D. at the Yangsoo-ri region. Judging from the iron from A-19 dwellingsite, it is possible to conclude that the iron was manufactured from cast iron decarburized and yet more research has to be done into relics yetto be exhumed in order to ascertain the finding. All of these findings are believed to play a critical role in further studies to define the steel-manufacturing technique used on the central Korean peninsular in the ancient times.

  • PDF

Thermal Memory Effect Modeling and Compensation in Doherty Amplifier (Doherty 증폭기의 열 메모리 효과 모델링과 보상)

  • Lee Suk-Hui;Lee Sang-Ho;Bang Sung-Il
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.9 s.339
    • /
    • pp.49-56
    • /
    • 2005
  • Memory effect, which influence the performance of Doherty amplifier, become more significant and critical in designing these circuits as the modulation signal bandwidth and operation power level increase. This paper reports on an attempt to investigate, model and quantity the contribution of the electrical nonlinearity effects and the thermal memory effects to a Doherty amplifier's distortion generation. Also this raper reports on the development of an accurate dynamic expression of the instantaneous junction temperature as a function of the instantaneous dissipated power. This expression has been used in the construction of an electrothermal model for the Doherty amplifier. Parameters for the nelv proposed behavior model were determined from the Doherty amplifier measurements obtained under different excitation conditions. This study led us to conclude that the effects of the transistor self-heating phenomenon are important for signals with wideband modulation bandwidth(ex. W-CDMA or UMTS signal). Doherty amplifier with electrothermal memory effect compensator enhanced ACLR performance about 20 dB than without electrothemal memory effect compensator. Experiment results were mesured by 60W LDMOS Doherty amplifier and electrothermal memory effect compensator was simulated by ADS.

Impacts of Different Urban Surfaces on Summer Thermal Performance

  • Jo, Hyun-Kil;Wu, Qian
    • Journal of Environmental Science International
    • /
    • v.24 no.6
    • /
    • pp.819-826
    • /
    • 2015
  • This study measured temperatures and albedos of urban surfaces for different colors and materials during summer, and calculated the energy budget over different urban surfaces to find out the thermal performance affecting the heat built-up. The study selected six surface colors and 13 materials common in urban landscape. Their surface temperatures (Ts) and albedos were measured at a given time interval in the daytime from June to August. Average Ts over summer season for asphalt-colored brick was $4.0^{\circ}C$ higher than that for light red-colored one and $9.7^{\circ}C$ higher than that for white-colored one. The Ts for artificial surface materials of asphalt paving, brown brick wall, and green concrete wall was $6.0^{\circ}C$ higher than that for natural and semi-natural ones of grass, grassy block, and planted concrete wall. There was the greatest difference of $16.3^{\circ}C$ at midafternoon in the Ts between asphalt paving and planted concrete wall. Average albedo over summer season of surface materials ranged from 0.08 for asphalt paving to 0.67 for white concrete wall. This difference in the albedo was associated with a maximum of $15.7^{\circ}C$ difference at midafternoon in the Ts. Increasing the albedo by 0.1 (from 0.22 to 0.32) reduced the Ts by about $1.3^{\circ}C$. Average storage heat at midday by natural and semi-natural surfaces of grass and grassy block was about 10% lower than that by artificial ones of asphalt, light-red brick, and concrete. Reflected radiation, which ultimately contributes to heating the urban atmosphere, was 3.7 times greater for light-red brick and concrete surfaces than for asphalt surface. Thus, surfaces with in-between tone and color are more effective than dark- or white-colored ones, and natural or semi-natural surfaces are much greater than artificial ones in improving the urban thermal environment. This study provides new information on correlation between Ts and air temperature, relationship between albedo and Ts, and the energy budget.

The effect of smoking on the quality boiled sausage (훈제 처리가 가열소지에 미치는 영향)

  • 정청송;유상훈
    • Journal of Applied Tourism Food and Beverage Management and Research
    • /
    • v.12 no.2
    • /
    • pp.1-41
    • /
    • 2001
  • The effect of smoking on the quality sausage Sausages were prepared from beef, port, chickens, games, fish and shellfish with polyphosphate salt and spices. Sausage history goes back to 3,000 years of age. The procedure of sausage 1) Meat Curing 2) Meat Control 3) Add Spices 4) Permissible Ingredients 5) Grinding 6) Mixing Emulsion 7) Stuffing 8) Showing 9) Smoking 10) Cooking 11) Drying 12) Packaging Sausage Product to get information on the effect of smoking onto the quality of meat produces. Sausage was smoked under a given conditions. Smoking was conducted as 35f$^{\circ}C$to 6$0^{\circ}C$ the related humidity of smokehouse was still at 60 to 70 percent. Results are as follows: 1. The Penetrated smoke in sausage was prolonged < p.<0.02 when sausage was smoked 2hours at 60~$65^{\circ}C$ the penetrated amount of free acetone in sausage was 0.5mg%. 2. Peroxide value of sausage as heating treatment both at 3$0^{\circ}C$ and at 5$0^{\circ}C$ was prolonged. 3. When sausage was heated at 3$0^{\circ}C$, bacteria of sausage increased In number while at 60~$65^{\circ}C$ bacteria of sausage increased In number fourteen hours. 4. When sausage was treated with smoking the distribution of free amino acids in sausage was changed markedly. 5. The longer smoking time of the products was the higher the content. 6. In case of oak wood smoke flavoring all of test samples. 7. Rapid decrease of does-response mutagenic curve of the smoke flavoring of oak wood and apple wood by in the peak of curve and phenol in the smoke flavoring. Continuous efforts are required to make sausages easily in the butcher shops and in the restaurants. 8. Sausage texture evaluation has 13 rules. It is Elasticity, Surface Moisture, Surface Smoothness, Center Hardness, Skin Toughness, Cohesiveness, Denseness, Moisture Release, Cohesiveness of Mass, Lumpiness, Graininess (of Contents), Skin separation, Oiliness and sensory 11 rules evaluation is color, texture, mold, flavor, sweet test, salty, sourness, bitter, and savory taste. 9. Smoked, component, peroxide value, bacteria, color, free amino acid, tenderness, flavor, shrinkage are important values.

  • PDF

Thermal Properties of Poly($\varepsilon$-Caprolactone)/Multiwalled Carbon Nanotubes Composites

  • Kim, Hun-Sik;Chae, Yun-Seok;Choi, Jae-Hoon;Yoon, Jin-San;Jin, Hyoung-Joon
    • Advanced Composite Materials
    • /
    • v.17 no.2
    • /
    • pp.157-166
    • /
    • 2008
  • In this study, multiwalled carbon nanotubes (MWCNTs) were compounded with the poly($\varepsilon$-caprolactone) (PCL) matrix at the solution state using chloroform. For homogeneous dispersion of MWCNTs in polymer matrix, oxygen-containing groups were introduced on the surface of MWCNTs. The mechanical properties of the PCL/MWCNTs composites were effectively increased due to the incorporation of MWCNTs. The composites were characterized using scanning electron microscopy in order to obtain information on the dispersion of MWCNT in the polymeric matrix. In case of 1.2 wt% of MWCNTs in the matrix, strength and modulus of the composite increased by 12.1% and 164.3%, respectively. In addition, the dispersion of MWCNTs in the PCL matrix resulted in substantial decrease of the electrical resistivity of the composites as the MWCNTs loading was increased from 0 to 2.0 wt%. Furthermore, thermal stability of the PCL and PCL/MWCNTs-COOH composites were investigated using the data acquired from the thermogravimetric analysis. The detailed kinetics of the thermal degradation of the composites was investigated by analyzing their thermal behavior at different heating rates in a nitrogen atmosphere. Activation energy of thermal degradation was determined by using the equations proposed by Kissinger and Flynn-Wall-Ozawa. The apparent activation energy of PCL/MWCNTs-COOH composite was considerably higher than that of neat PCL.

Embedded-based Power Monitoring Security Module Design (임베디드 전력 모니터링 보안 모듈 설계)

  • Yoon, Chan-Ho;Kim, Gwang-Jun;Jang, Chang-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.10
    • /
    • pp.1485-1490
    • /
    • 2013
  • The demonstration project of the electrical grid for Smart grid is progressed, the smart digital appliances AV technology, Smart home energy management technology charging the management function of complex energy for the automation management of air conditioning and heating, humidity and air, the health care technology charging the design of housing for the elderly and disabled and the measurement of individual bio information, and the Smart home security technology dealing with the biometric security and motion sensors, etc. have been studied. The power monitoring terminal which uses a variety of wired and wireless networks and protocol is the target additionally to be considered in addition to the security vulnerabilities that was occurred in the existing terminal. In this research paper, the author analyzes the cryptographic techniques corresponding to the smart meter occurred by the problems that are exposed on the outside which are vulnerable to physical attacks, and intends to propose the design of the security systems for the Smart meter terminal being able to maximize the efficiency of the terminal.

A Survey on the Electric Power Consumptions of Apartments located at Coastal Area : Yeongdo-gu, Busan, Korea (연안지역 아파트의 전력소비량 실태조사 - 부산광역시 영도구에 대한 사례연구 -)

  • Hwang, Kwang-Il
    • Journal of Navigation and Port Research
    • /
    • v.33 no.3
    • /
    • pp.241-245
    • /
    • 2009
  • Because of the heat island phenomenon and sea wind, there can be thermal conditions' differences around buildings at downtown and coastal area respectively in coastal city, like Busan, Incheon, Mokpo. For the final purpose of the buildings' energy saving design and operation considering of above mentioned environments differences, energy consumption including heating and cooling loads, electric loads are necessary to be accumulated and analyzed in as the database. As a part of this concept, this study aims to survey and analyze each loads of 22 apartments which has at least 100 households respectively and is located at Yeongdo island, Busan, Korea It is cleared that despite the residents living in this district can use sea wind as a natural ventilation and/or cooling methods, they mainly depends on the electric-driven air-conditioners for cooling with window-closed because of anti-salt problems of the sea wind. This leads the maximum power consumption of the surveyed-22-apartments to be appeared in August like that of inland buildings.

Thermal Energy Storage and Release Characteristics of the Soil in the Greenhouse Equipped with Heat Pump and Latent Heat Storage System (열펌프-잠열축열 시스템 온실에서 토양의 열저장 및 방열 특성)

  • 노정근;송현갑
    • Journal of Biosystems Engineering
    • /
    • v.27 no.1
    • /
    • pp.39-44
    • /
    • 2002
  • In order to obtain the information of bio-environment control, the thermal characteristics of soil in the greenhouse heated by the heat pump and latent heat storage system were experimentally analyzed. The experimental systems were composed of the greenhouse with a heat pump and a latent heat storage system (system I), the greenhouse with a heat pump (system II), the greenhouse with a latent heat storage system (system III), and the greenhouse without auxiliary heating system (system IV). The thermal characteristics experimentally analyzed in each system were temperature of soil layers, soil heat storage and release, soil heat capacity and soil heat storage ratio. The results could be summarized as follows. 1. Time to reach the highest temperature at 20cm deep in soil layers of the crop routs in case of system I was shown to be delayed by 6 hours in comparison to the time of the highest temperature at the soil surface. 2. In the clear winter days, the stored heat capacity values fur the system I and the system II were shown to be 22.3% and 11.0% higher than the released heat capacity respectively, and the stored heat capacity values for the system III and the system IV were shown to be 6.2% and 29.6% lower than the released heat capacity respectively This confirms that the system I provided the best heat storage effect. j. The heat quantity values stored or released were shown to be highest at 5 cm depth of soil layers. And it was reduced with increasing of depth of soil layers until 20 cm and was not changed under the soil layer of 20 cm depth. 4. The heat absorption rates of soil, the ratio between supplied and stored heat energy, fur both the system I and system II were lower than 23%.