• 제목/요약/키워드: heating

검색결과 11,331건 처리시간 0.033초

Improvement of Heating Pattern in RF Hyperthermia -Simultaneous Application of Dielectric Heating and Induction Heating-

  • Sakakibara, Norifumi;Ochiai, Makoto;Hayakawa, Yoshinori
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.478-480
    • /
    • 2002
  • Heating by RF wave is divided into dielectric heating and induction heating. Dielectric heating and induction heating from outside the body have the compensatory heating pattern. While surface fat layer is heated by dielectric heating, it is not heated by induction heating. While the peripheral part at the middle of the electrodes is not heated by dielectric heating, it is heated by induction heating. By the simultaneous application both modalities, heating pattern seems to be more uniform and improved. Computer simulation of Finite Element Method (FEM) using ANSYS was conducted to dielectric heating with the results of above-mentioned feature. Theoretical considerations by the uniform RF magnetic field in a cylinder and textbooks support the feature of the above-mentioned heating pattern of induction heating. Further computer simulation of FEM using ANSYS will be conducted to simultaneous application of dielectric heating and induction heating to verify and will be reported.

  • PDF

바닥난방이 육계의 사육환경 및 생산성에 미치는 영향 (Effect of Floor Heating System on Housing Environment and Performance in Broiler Production)

  • 최희철;이덕수;서옥석;한정대;강희설;권두중;곽정훈;강보석;장병귀
    • 한국가금학회지
    • /
    • 제26권3호
    • /
    • pp.189-193
    • /
    • 1999
  • This experiment was conducted to investigate the effect of floor heating system on housing environment and performance in broiler production. PVC heating pipes(in 25cm spacing) were covered with concrete under the litter. Floor heating system was compared with conventional direct heating system. Each treatment had two replicates of 110 birds each. Litter moisture content was significantly reduced in floor heating system than conventional direct heating system(P〈0.05). Dust concentration was higher in floor heating system because of low litter moisture content. CO$_2$concentration was 2,900ppm and 1,500ppm on the direct heating system and floor heating system, respectively at the age of 1 week. Body weight was significantly higher in floor heating system at 7 weeks of age(P〈0.05). The results of the trial show that floor heating was useful heating system for broiler production.

  • PDF

고주파 유도가열을 사용한 급속 금형가열에 관한 연구 (A Study on Rapid Mold Heating System using High-Frequency Induction Heating)

  • 정희택;윤재호;박근;권오경
    • 대한기계학회논문집A
    • /
    • 제31권5호
    • /
    • pp.594-600
    • /
    • 2007
  • Rapid mold heating has been recent issue to enable the injection molding of thin-walled parts or micro/nano structures. Induction heating is an efficient way to heat a conductive workpiece by means of high-frequency electric current caused by electromagnetic induction. Because the induction heating is a convenient and efficient way of indirect heating, it has various applications such as heat treatment, brazing, welding, melting, and mold heating. The present study covers an experimental investigation on the rapid heating using the induction heating and rapid cooling using a vortex tube in order to eliminate an excessive cycle time increase. Experiments are performed in the case of a steel cup mold core with various heating and cooling conditions. Temperature is measured during heating and cooling time, from which appropriate mold heating and cooling conditions can be obtained.

공동주택용 온수난방 시스템의 에너지해석 및 제어특성 (The Energy Analysis and Control Characteristics of a Hot Water Heating System for Apartment Houses)

  • 장효환;안병천
    • 설비공학논문집
    • /
    • 제8권1호
    • /
    • pp.76-87
    • /
    • 1996
  • Energy analysis for the hot water heating control system of apartment house complex is accomplished by computer simulation. Mathematical model of a boiler, pipe network and a unit-house is developed. The effects of heating control methods on the heating performance and energy consumption of the system are investigated. The heating control methods considered in this study are a continuous heating control, and on-off heating control and an intermittent heating control methods. For each control method, the effects of an outdoor temperature, indoor temperature sensing position and the capacities of the boilers and circulating pumps on the heating performance and energy consumption are obtained and "the best" control method is recommended.commended.

  • PDF

직접 가열 방식을 이용한 반도체 제조용 히팅 장치 (A Heating Apparatus for Semiconductor Manufacturing using Direct Heating Method)

  • 정순원;구경완
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.408-411
    • /
    • 2008
  • As to this research is new structure of the semiconductor substrate heating apparatus. The fast thermoresponsive according to the direct heating structure of the heating plate layer adhering closely to the floor side of a substrate and the fast heat loss minimization can be accomplished. Moreover, the contact area of the sheath heater, which is the heating plate layer built-in heating apparatus, is increased, so that it has more heating valid area. For this, it adheres closely to the substrate, in which the photosensitive film is coated and the heating plate layer, adhering closely to the floor side of a substrate the mica layer which adheres closely to the floor side of the upper heating plate layer in order to minimize an insulation and heat loss, and the lower part of the mica layer and it is comprised of the floor plate layer. The heating plate layer forms the continued groove portion over the floor side whole. The sheath heater for heating a substrate is inserted with the groove portion and the heating plate layer is comprised. It is confirmed that by using the new substrate heating structure, the temperature change of the heating plate against the time is observed. Then, there is the electric power saving effect of about 40% in comparison with the existing method.

YSZ/Ni-Cr 저항 발열 복합용사피막의 특성 (Characteristics of plasma sprayed composite YSZ/Ni-Cr resistant heating coatings)

  • 김병수;박경채;김태형;양병모
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2003년도 춘계학술발표대회 개요집
    • /
    • pp.111-113
    • /
    • 2003
  • The existing heating unit is indirect-heating method that make use or the nichrome wire or halogen lamp. The indirect-heating method has the demerits of long warming time, high power consumption and many organization parts. In this study, the heating unit of direct-heating method manufactured as being the thermal spray coating of conductive heating material on the surface of heating unit in order to improve the demerits of indirect-heating method. And YSZ added Ni-20Cr that had moderate electrical resistivity was chosen of the conductive heating material.

  • PDF

미송 대단면재의 가열법에 따른 진공건조 특성 (Vacuum Drying Characteristics Using Different Heating Methods for Douglas-fir Timber)

  • 정희석;엄창득;소범준
    • Journal of the Korean Wood Science and Technology
    • /
    • 제32권4호
    • /
    • pp.18-26
    • /
    • 2004
  • 변장 14 cm 재장 2.4 m인 대단면재의 전도가열, 고주파가열 및 복합가열에 의한 진공건조특성을 조사하였다. 건조속도는 복합가열에서 가장 컸고, 고주파가열에서 가장 적었다. 비에너지는 고주파가열에서 가장 컸고, 전도가열에서 가장 적었다. 진공건조목재의 횡단방향 함수율분포는 전도가열과 복합가열의 경우 불록한 형태를 나타냈으나, 고주파가열의 경우는 한쪽 표층에서 반대쪽 표층으로 향해 증가하는 경향을 나타내었다. 건조목재의 재장방향 함수율은 전도가열과 복합가열의 경우 횡단면이 중심부위보다 낮았고 고주파가열의 경우 횡단면이 중심보다 높았다. 표면할렬과 횡단면할렬은 전도가열진공건조에서 가장 심하였다. 내부할렬은 어떠한 가열방법에 의한 건조에서도 발생하지 않았다. 복합가열 진공건조 특성은 전도가열과 고주파가열간의 절충된 중간적 경향을 나타냈다.

시설원예의 지열냉·난방시스템 경제성 분석 (Economic Analysis of Cooling-Heating System Using Ground Source Heat in Horticultural Greenhouse)

  • 류연수;주혜진;김진욱;박미란
    • 한국태양에너지학회 논문집
    • /
    • 제32권6호
    • /
    • pp.60-67
    • /
    • 2012
  • Government Geothermal Cooling-Heating Projects has made efforts to reduce GHG(Greenhouse Gas) emissions and to manage cost of greenhouse farm households. This study evaluated the economic benefits of heating load rate of change by comparing Geothermal Cooling-Heating System with the existing system(greenhouse diesel heating) in the Government Geothermal Cooling-Heating Projects. Economic analysis results shows that, 1) When installing the Cooling-Heating system according to the ratio of 70% heating load in policy standards, the geothermal cooling-heating system has economic efficiency with greenhouse type or scale independent because the investment cost is recovered within 7 years. And It was more economic efficiency the ratio of 50% heating load than70% heating load. 2) When installing the Cooling-Heating system according to the glass greenhouse of the ratio of 90% heating load, pay period of investment cost is recovered within 5 years. Therefore it is necessary to apply flexible heating sharing according to greenhouse type or scale.

Reduced LS-SVM을 이용한 지역난방 동절기 공동주택 난방부하의 모델링 (Modeling of Winter Time Apartment Heating Load in District Heating System Using Reduced LS-SVM)

  • 박영칠
    • 설비공학논문집
    • /
    • 제27권6호
    • /
    • pp.283-292
    • /
    • 2015
  • A model of apartment heating load in a district heating system could be useful in the management and utilization of energy resources, since it could predict energy usage and so could assist in the efficient use of energy resources. The heating load in a district heating system varies in a highly nonlinear manner and is subject to many different factors, such as heating area, number of people living in that complex, and ambient temperature. Thus there are few published papers with accurate models of heating load, especially in domestic literature. This work is concerned with the modeling of apartment heating load in a district heating system in winter, using the reduced least square support vector machine (LS-SVM), and with the purpose of using the model to predict heating energy usage in domestic city area. We collected 23,856 pieces of data on heating energy usage over a 12-week period in winter, from 12 heat exchangers in five apartments. Half of the collected data were used to construct the heating load model, and the other half were used to test the model's accuracy. The model was able to predict the heating energy usage pattern rather accurately. It could also estimate the usage of heating energy within of mean absolute percentage error. This implies that the model prediction accuracy needs to be improved further, but it still could be considered as an acceptable model if we consider the nonlinearity and uncertainty of apartment heating energy usage in a district heating system.

필름 히터를 이용한 스마트 팜 난방 성능 설계에 관한 연구 (A Study on the Design of Smart Farm Heating Performance using a Film Heater)

  • 김웅
    • 소성∙가공
    • /
    • 제32권3호
    • /
    • pp.153-159
    • /
    • 2023
  • This paper presents the optimal design of a heating system using radiant heating elements for application in smart farms. Smart farming, an advanced agricultural technology, is based on artificial intelligence and the internet of things and promotes crop production. Temperature and humidity regulation is critical in smart farms, and thus, a heating system is essential. Radiant heating elements are devices that generate heat using electrical energy. Among other applications, radiant heating elements are used for environmental control and heating in smart farm greenhouses. The performance of these elements is directly related to their electrical energy consumption. Therefore, achieving a balance between efficient electrical energy consumption and maximum heating performance in smart farms is crucial for the optimal design of radiant heating elements. In this study, the size, electrical energy supply, heat generation efficiency, and heating performance of radiant heating elements used in these heating systems were investigated. The effects of the size and electrical energy supply of radiant heating elements on the heating performance were experimentally analyzed. As the radiant heating element size increased, the heat generation efficiency improved, but the electrical energy consumption also increased. In addition, increasing the electrical energy supply improved both the heat generation efficiency and heating performance of the radiant heating elements. Based on these results, a method for determining the optimal size and electrical energy supply of radiant heating elements was proposed, and it reduced the electrical energy consumption while maintaining an appropriate heating performance in smart farms. These research findings are expected to contribute to energy conservation and performance improvement in smart farming.