• 제목/요약/키워드: heat transmission coefficient

검색결과 53건 처리시간 0.026초

자연형 태양 챔버 시스템의 계절별 성능 및 크기 결정 방법 (Sizing Method and Seasonal Performance of Passive Solar Chamber System)

  • 장향인;김병구;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.66-71
    • /
    • 2011
  • This study focused on the application of the Passive Solar Chamber System (PSCS) as proposed by a previous study. The seasonal performance and sizing method for the system were investigated for a feasibility of the PSCS in Korean climate. For seasonal performance, heat and ventilation performances of the PSCS were analyzed for the months of January and August. This study proposed a simple configuration method in which the designer can decide on the system size at the preliminary design stage by using system efficiency, overall heat transfer coefficient transmission, monthly solar radiation, highest and lowest temperatures. During weeks that require heating, the system showed to acquire a daily average heat amount of $860.28Wh/m^2$ day. For cooling periods, the system was computed to supply a daily average natural ventilation of $1,360.2m^3/day$ to the room. Moreover, proposed sizing method and the overall computation results showed a 6.04~7.24% error of assessment.

온실용 다겹보온자재의 보온성 비교 -Hot box 시험 결과를 중심으로- (Comparison of Thermal Insulation of Multi-Layer Thermal Screens for Greenhouse: Results of Hot-Box Test)

  • 윤성욱;이시영;강동현;손진관;박민정;김희태;최덕규
    • 생물환경조절학회지
    • /
    • 제28권3호
    • /
    • pp.255-264
    • /
    • 2019
  • 본 연구에서는 현장 온실농가에서 수명이 다하여 교체작업이 이루어진 총 4종의 다겹보온자재를 채취하여 해당 사용기간별 보온성의 변화를 비교하기 위해 여기서 고안된 Hot box 시험이 실시되었다. 4종의 다겹보온자재는 마트지, 부직포, PE폼 및 화학솜 등이 주요 재료로서 다겹보온자재별로 이 재료들이 서로 다르게 조합된 형태였다. 이 4종의 다겹보온자재를 시편($70{\times}70cm$)으로 제작하여 Hot box 시험을 통해서 대상시편별로 온도 하강률, 열관류율 및 열전도저항 등이 측정되었다. 그 결과를 요약하면 다음과 같다. 본 연구에서 사용된 다겹보온자재들에 대하여 적절한 보온성능을 기대할 수 있는 사용기간은 약 5년 정도로 예상되었다. 다겹보온자재의 재료조합에 대하여 다겹의 PE폼을 적용하여 상대적으로 보온성을 높일 수 있으나 다겹보온자재 내에서 공기 단열층을 형성하는 화학솜에 비해 보온성능에 대한 기여가 현저히 낮은 것으로 판단되었다. 다겹보온자재에 대하여 적절한 보온성능을 기대하기 위해서는 기본적으로 화학솜과 같은 공기 단열층을 형성하는 기능이 있는 재료가 다겹보온자재에 포함되어야 될 것으로 판단되었다. 본 연구에서 고안된 Hot box 시험을 통해 다겹보온 자재의 온도 하강률, 열관류율 및 열전도저항 등이 적절하게 측정되었다. 그러나 본 연구는 사용이 완료된 다겹보온자재의 채취 어려움으로 총 4종의 다겹보온자재만 고려되었으며, 이는 비교적 적은 사례로 통해 얻어진 결과라 할 수 있으며, 본 연구의 한계이다. 향후 관련 연구를 통해 더 많은 사례들이 조사 및 보완되어야 될 것이다.

목재내(木材內)의 수분확산(水分擴散) 및 전달현상(傳達現象)에 관한 실험적 검정(檢定) (Experimental Examinations on the Phenomenon of Transfer and Moisture Diffusion in Wood)

  • 이원희
    • Journal of the Korean Wood Science and Technology
    • /
    • 제24권1호
    • /
    • pp.75-80
    • /
    • 1996
  • The purpose of this study is to clarify the mechanism of moisture transfer depend on the thickness of the spruce(Picea sitchensis Carr.). Therefore, as the basic research of moisture transmission, the amount of moisture transmission and the moisture distribution in specimens and temperature of it's surfaces in vapor transmission process were investigated. The experiment was conducted in a steady state. and the moisture distribution was measured by knife cutting and weighing the specimens. The following conclusions were obtained ; 1. It can be found that distribution of moisture in the specimen can be approximated by two different straight lines intersecting at nine or ten percent moisture content. The amount of moisture movement defends on the gradient of moisture in the wood. 2. It is investigated that the wood surface moisture contents(MCs) are less for thinner specimens than for thick ones on the absorption side. On the other hand, the wood surface MCs are greater for thinner specimens than for thick ones on the desorption side. The main factor that affects the EMC of wood would be temperature when the relative humidity of atmosphere is constant. The specimen generate heat with the absorption and desorption process. In addition, the velocities of moisture transmission varied with the thicknesses of specimens. If the temperature of wood becomes greater, its MC decreases. Then the difference between surface MC and EMC of adsorption and desorption side becomes greater for thinner specimens. Therefore it is considered that the coefficients of moisture transfer decreases with the increases of the specimens' thicknesses.

  • PDF

노후화된 대학 건물의 단열성능 향상 실험 및 경제성 평가 (An Experimental Study on the Improvement of Insulation Performance in Old University Buildings and Economic Evaluation)

  • 이정민;소원호;조경찬;최동녁;이권영
    • 한국산학기술학회논문지
    • /
    • 제21권8호
    • /
    • pp.287-297
    • /
    • 2020
  • 본 연구는 노후화된 대학 건물의 내부 단열 성능 향상에 대한 것으로, 대학교 건물 내 재실자의 생산성을 높이고 노후화된 건물의 단열효과를 높이기 위해 진행됐다. 본 논문은 한동대학교 느헤미야홀 건물 내 오피스 재실자의 단열 성능 향상에 대한 지속적인 요청에 응답하여 문제해결을 위해 진행된 연구라는 차별성을 가지고 있으며, 내부온도가 인접건물의 내부온도와 비교했을 때 낮음을 확인하여 연구 필요성에 대한 타당성을 검증하였다. 학교라는 건물의 특성을 고려해 내외부 단열 중 내부 단열을 주제로 단열재를 선택했다. 대학교 교수 오피스를 소형화시킨 모형 방을 만들어 시장에서 사용되는 내부 벽면 단열재를 설치해 실험을 진행했다. 실험 결과를 바탕으로 가열 시간과 실제 열전달 계수를 측정하여 단열효과를 분석하는 경제성 평가를 실시했다. 경제성 평가는 실험과 이론에 의해, 겨울철과 여름철 기준으로 각각 실시되었다. 연구결과, 느헤미야홀 60 개의 오피스에 아이소핑크(30 T)를 내 단열재로 도입하였을 때, 한 달에 겨울철에는 최대 총 1,071,600 원을 절약 할 수 있으며, 여름철에는 총 109,200 원을 절약할 수 있다.

투명 결정화 유리에 관한 연구 -Li2O-Al2O3-SiO2계 조성에 관하여- (Studies on Transparently Crystallized Glass -On Li2O-Al2O3-SiO2 Composition-)

  • 박용완;김건은;연석주;조중희
    • 한국세라믹학회지
    • /
    • 제26권3호
    • /
    • pp.315-322
    • /
    • 1989
  • Li2O-Al2O3-SiO2 system glasses contained P2O5, TiO2 and ZrO2as the nucleating agents were melted and formed. The glass was subsequently heated first to nucleate and then to grow the crystals. At constant nucleating agent content the base glass compositions were varied and the influences of these variations on the crystallization behaviour were investigated. The study was made by measurement of thermal expansion coefficient, differential thermal analysis, X-ray diffraction analysis, scanning electron microscope observation and transmission measurement of crystallized glass specimen in visible region. It was shown that the content of crystalline phase decreased with increasing SiO2 content as well as decresing Li2O in the base glass compositions. As the result of X-ray diffrection analysis, the major crystal was $\beta$-quartz solid solution. The degree of crystallinity which was calculated using the noncrystalline scattering methods increased in S-shape with increasing heat treatment time. This change was similar to that in thermal expansion coefficient. The transmissions of 5mm thick samples were 80-90% in visible ray region.

  • PDF

Fe계 합금 분말 소결품(SMF9060)의 마모 특성 연구 (A Study on Tribological Characteristics of Powder Sintered Fe-base Alloy (SMF9060))

  • 김상윤;김대욱;박영민;신동철;김태규
    • 열처리공학회지
    • /
    • 제27권2호
    • /
    • pp.65-71
    • /
    • 2014
  • SMF9060 material is a Fe-based powder sintered alloy that is used for several automobile components such as Synchronize Hub, oil pump and transmission. These components are required excellent wear resistance and durability. In this study, we have performed a dry wear test at the ambient air and Ar gas conditions in the room temperature, and a lubricant wear test at the room temperature and engine oil temperature of $100^{\circ}C$. The amount of wear volume and coefficient friction are measured by a Profilometer and a Ball on disk type wear tester. The wear volume in Ar gas condition was a little higher than that in the ambient air condition. However the wear volume in the lubricant wear condition was much lower than in the dry wear condition. XRD analysis of the debris in Ar gas condition showed that the oxide film was not formed.

Modification of DC Flashover Voltage at High Altitude on the Basis of Molecular Gas Dynamics

  • Liu, Dong-Ming;Guo, Fu-Sheng;Sima, Wen-Xia
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.625-633
    • /
    • 2015
  • The effect of altitude on thermal conduction, surface temperature, and thermal radiation of partial arc was investigated on the basis of molecular gas dynamics to facilitate a deep understanding of the pollution surface discharge mechanism. The DC flashover model was consequently modified at high altitude. The validity of the modified DC flashover model proposed in this paper was proven through a comparison with the results of high-altitude simulation experiments and earlier models. Moreover, the modified model was found to be better than the earlier modified models in terms of forecasting the flashover voltage. Findings indicated that both the thermal conduction coefficient and the surface thermodynamics temperature of partial arc had a linear decrease tendency with the altitude increasing from 0 m to 3000 m, both of which dropped by approximately 30% and 3.6%, respectively. Meanwhile, the heat conduction and the heat radiation of partial arc both had a similar linear decrease of approximately 15%. The maximum error of DC pollution flashover voltage between the calculation value according to the modified model and the experimental value was within 6.6%, and the pollution flashover voltage exhibited a parabola downtrend with increasing of pollution.

Energy demand analysis according to window size and performance for Korean multi-family buildings

  • Huh, Jung-Ho;Mun, Sun-Hye
    • Architectural research
    • /
    • 제15권4호
    • /
    • pp.201-206
    • /
    • 2013
  • Special attention is required for the design of windows due to their high thermal vulnerability. This paper examines the problems that might arise in the application of the u-value, by reflecting the changes in the u-value of the window, depending on the window-to-wall ratio obtained in an energy demand analysis. Research indicates that the u-value of a window increases with an increase in the difference between the u-values of the frames and the glass. Relative to the changes in the u-value of the windows, the energy demand varied from 1.3% to 9.3%. Windows with a g-value of 0.3 or 0.5 displayed a higher energy demand than windows with a g-value of 0.7. Therefore, when the difference between the performance of the glass and the frame is significant, especially when the g-value is small, a modified heat transmission coefficient should be applied to the window size during the evaluation of the building energy demand.

방사율에 따른 진공유리 열관류율 수치해석 연구 (A Study on Numerical Analysis of Overall Heat Transmission Coefficient of Vacuum Glazing with Emissivity)

  • 황일선;이영림
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2012년도 춘계학술논문집 2부
    • /
    • pp.756-758
    • /
    • 2012
  • 인구증가와 지속적인 산업발전으로 인하여 건축이 매우 활발해지고 냉난방으로 인한 에너지 소비가 급증하게 되면서 효율적인 에너지 사용의 필요성이 크게 대두되었다. 건물에서 손실되는 에너지의 약 20~40%가 창문을 통해 손실이 일어나며 이를 해결하고자 현재 Low-E 유리, 복층유리등 다양한 방법들이 개발되어 사용하고 있으며 에너지 손실을 더욱 낮추기 위하여 진공유리가 개발 중이나 아직 보급은 이루어지지 않고 있다. 본 논문에서는 진공유리의 열관류율 측정 장치와 진공에서의 중요한 열전달 요인인 복사열전달이 진공유리 성능에 미치는 영향을 3차원 수치해석을 통하여 알아보았다.

  • PDF

실내 차양장치 결합형 창호의 태양열 취득률 평가에 대한 실험적 연구 (A Experiment Study on Performance Evaluation of Solar Heat Gain Coefficient in Glazing with Shading Devices)

  • 김태중;강재식;박준석
    • 한국태양에너지학회 논문집
    • /
    • 제34권5호
    • /
    • pp.89-99
    • /
    • 2014
  • The determination of the solar and thermal performance of fenestration is required for the evaluation of fenestration energy performance, estimating building load. Presently, there exist several methods for determining the thermal transmission(U-value) and solar heat gain coefficient (SHGC) of fenestration system. These method are commonly grouped under calculation or experimental methods. While U-value testing and calculation methods have been long established, SHGC has been evaluated only by the method of calculation under the lack of any established testing method. However, it is difficult to assess the exact SHGC for various types of fenestration with sun-shading or other solar control systems. The purpose of this study was to evaluate the effect of interior venetian blind and roll screen on the SHGC of glazing system. SHGC has been evaluated by the KS L 9107 test method and exiting calculation method for precise comparison of the energy performances of various shading devices. In this research, the test sample consists of three different types of double glazing unit with venetian blind and roll screen. Slat angles of venetian blind were changed to $-45^{\circ}$, $0^{\circ}$, and$-45^{\circ}$. For the roll screen, measurements were taken with the roll screen in the closed position. In result, the venetian blind reduced SHGC by 21.2~28.4% at $45^{\circ}$, when compared to the double glazing unit. The roll screen reduced SHGC by 34.4~41.7% at closed. The differences between the measured and calculated SHGC were found to range between 0.001(0.2%) and 0.047(11.1%) for all test cases. For the cases of venetian blind $-45^{\circ}$, $0^{\circ}$ and $45^{\circ}$, the deviation ratio were 3.6~9.8%, 1.1~2.6%, 4.2~11.1%, respectively. For the case of roll screen, the deviation ratio were 4.1~5.7%.