• 제목/요약/키워드: heat transfer modeling

검색결과 377건 처리시간 0.026초

Numerical Analysis of Micro-jet Array Cooling Device with Various Configurations

  • Jung, Yang-Ki;Lee, In-Chan;Ma, Tae-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권2호
    • /
    • pp.39-45
    • /
    • 2005
  • Numerical and visualization procedures are used in a finite difference grid to analyze and better understand the heat transfer in the MEMS based air micro-jet array (MIA) impingement cooling device. The Navier-Stokes (NS) equations with incompressible flow are solved using an implicit procedure. The temperature contour and velocity vector visualization diagrams are used for illustration. The computed temperature distribution at the bottom of the MIA is in good agreement with the experimental measurement data. The parameters are investigated to improve the efficiency of heat transfer in the MIA. The optimum configuration of the MIA is suggested. The present modeling explains the flow phenomenon and yields valuable information to understand the flow and heat transfer in MIA.

Study on the heat and mass transfer in ultrasonic assisting vacuum membrane distillation

  • Guo, Hao;Peng, Changsheng;Ma, Weifang;Yuan, Hetao;Yang, Ke
    • Membrane and Water Treatment
    • /
    • 제8권3호
    • /
    • pp.293-310
    • /
    • 2017
  • An ultrasonic assisting vacuum membrane distillation (VMD) system was designed to promote the heat and mass transfer in membrane distillation (MD) process. Both the effects of operating conditions and ultrasonic parameters to permeation flux in this process were investigated; the heat and mass transfer mechanism was also being discussed in this paper. The results showed that the performance of VMD process was improved significantly by ultrasonic assisting. The permeation flux was boosted at a certain feed solution temperature, pressure at permeate side and feed solution velocity whether or not to PP and PTFE. The results also indicated that ultrasonic power and frequency also was the key factor affecting the mass and transfer efficiencies. The feed side transfer coefficient ($K_f$), corresponding to ultrasonic power ($K_f=4.406-0.026{\times}P+7.824{\times}10^{-5}{\times}P^2$) and ultrasonic frequency ($K_f=0.941+0.598{\times}f-0.012{\times}f^2+6.283{\times}10^{-5}f^3$), was obtained and employed in the modeling of ultrasonic assisting VMD process. The modeling results showed that the calculated value of $K_f$ aligned with experimental results well. Both variations of temperature polarization coefficient (TPC) and concentration polarization coefficient (CPC) were studied based on the obtained data. The results showed that both TPC and CPC were improved obviously by the ultrasonic parameters.

용탕주조법을 이용한 금속복합재료 제조공정의 열전달 해석 (Numerical Modeling of Heat Transfer for Squeeze Casting of MMCs)

  • 정창규;정성욱;남현욱;한경섭
    • 대한기계학회논문집A
    • /
    • 제26권10호
    • /
    • pp.2104-2113
    • /
    • 2002
  • A finite element model is developed for the process of squeeze casting of metal matrix composites (MMCs) in cylindrical molds. The fluid flow and the heat transit. are fundamental phenomena in squeeze casting. To describe heat transfer in the solidification of molten aluminum, the energy equation is written in terms of temperature and enthalpy are applied in an axisymmetric model which is similar to the experimental system. A one dimensional flow model simulates the transient metal flow. A direct iteration technique was used to solve the resulting nonlinear algebraic equations, using a computer program to calculate the enthalpy, temperature and fluid velocity. The cooling curves and temperature distribution during infiltration and solidification were calculated fer pure aluminum. Experimentally, the temperature was measured and recorded using thermocouple wire. The measured time-temperature data were compared with the calculated cooling curves. The resulting agreement shows that the finite element model can accurately estimate the solidification time and predict the cooling process.

Hybrid medium model for conjugate heat transfer modeling in the core of sodium-cooled fast reactor

  • Wang, X.A.;Zhang, Dalin;Wang, Mingjun;Song, Ping;Wang, Shibao;Liang, Yu;Zhang, Yapei;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • 제52권4호
    • /
    • pp.708-720
    • /
    • 2020
  • Core-wide temperature distribution in sodium-cooled fast reactor plays a key role in its decay heat removal process, however the prediction for temperature distribution is quite complex due to the conjugate heat transfer between the assembly flow and the inter-wrapper flow. Hybrid medium model has been proposed for conjugate heat transfer modeling in the core. The core is modeled with a Realistic modeled inter-wrapper flow and hybrid medium modeled assembly flow. To validate present model, simulations for a three-assembly model were performed with Realistic modeling, traditional porous medium model and hybrid medium model, respectively. The influences of Uniform/Non-Uniform power distribution among assemblies and the Peclet number within the assembly flow have been considered. Compared to traditional porous medium model, present model shows a better agreement with in Realistic modeling prediction of the temperature distribution and the radial heat transfer between the inter-wrapper flow and the assembly flow.

지하수 히트펌프 시스템의 대수층 활용 사레 연구 (Study on the aquifer utilization for a ground water heat pump system)

  • 심병완;이철우
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.32-35
    • /
    • 2006
  • The validation of a groundwater source heat pump system installation site is estimated by bydrogeothermic model ing. The hydraulic characteristics of the aquifer system is evaluated from pumping and recovery tests. In addition, the temperature distribution by the pumping and the injection of groundwater, and water level fluctuations are simulated by numerical modeling. The total cooling and heating load for the building is designed as 120RT(refrigeration ton) and the ground water source heat pump system covers 50RT as a subsidiary system The scenario of heat pump operation is organized as pumping and inject ion of groundwater that is performed for 8 hours per day in cooling mode for 90 days during the summer season The heat transfer by the injected warm water is limited near the inject ion wells in the simulated temperature distribution. The reason is that the given operation time is too short to expect broad thermal diffusion in large volume of the aquifer in the simulation time The simulated groundwater level and temperature distribution can be used as important data to develope an energy effective pumping and injection well system. Also it will be very useful to evaluate the hydraulic capacity of a target groundwater reservoir.

  • PDF

固體分末 이 浮上된 二相亂流 管流動 의 熱傳達 解析 (Analysis of Turbulent Heat Transfer of Gas-Solid Suspension Flow In Pipes)

  • 김재웅;최영돈
    • 대한기계학회논문집
    • /
    • 제6권4호
    • /
    • pp.331-340
    • /
    • 1982
  • Numerical analysis is made on the turbulent heat transfer with suspension of solid particles in circular tube with constant heat flux. The mean motion of suspending particles in mixture is treated as the secondary gas flow with virtual density and viscosity. Our modeling of turbulent transport phenomena of suspension flow is based on this assumption and conventional mixing length theory. This paper gives the evidence that the mixing length models can be extended to close the governing equations for two phase turbulent flow with solid boundary at a first order level. Results on Nusselt numbers obtained by analytical treatments are compared with available experimental data and discussed. They suggest that the most important parameters of two phase turbulent heat transfer phenomena are relative particle diameter to pipe diameter, gas-solid loading ratio, and specific heat of suspending material.

Intake Valve Temperature Effect on the Mixture Preparation in a SI Engine During Warm-up

  • 신영기
    • 한국자동차공학회논문집
    • /
    • 제5권5호
    • /
    • pp.51-66
    • /
    • 1997
  • A heat transfer model of the intake valve in a spark ignition engine is presented, which is calibrated with a number of the valve temperature profiles measured during engine warm-up for the gaseous fuel(propane). The valve is divided into four identical elements for which the assumption of lumped thermal mass is applied. The calibration is made so that the difference between the measued and simulated valve temperatures becomes minimal. Then the model is applied to the cases of the liquid fuel(indolene) to estimate the amount of the liquid fuel vaporized from the intake valve by assuming that fuel evaporation accounts for the deficit of the heat balance budget. The results of the model show quantitative contribution of each heat transfer source to the heat balance. The behavior of the calculated mass fraction of the fuel vaporized from the intake valve explains how the liquid fuel evaporate during engine warm-up. The mass fraction at warmed-up condition is closely related with the fraction directly targeted on the valve back by the fuel spray geometry.

  • PDF

Modeling of the Drying Process in Paper Plants

  • Hwang, Ki-Seok;Yeo, Yeong-Koo;Yi, Sung-Chul;Dongjun Seo;Hong Kang
    • 펄프종이기술
    • /
    • 제35권5호
    • /
    • pp.53-61
    • /
    • 2003
  • In this study a model for the drying process in paper production plants was developed based on the mass and heat balances around drying cycles. Relationships for the heat transfer coefficients between the web and the air as well as between the drying cylinder and the web were extracted from the closed-loop plant operation data. It was found that the heat transfer coefficients could be represented effectively in terms of moisture content, basis weight and reel velocity. The effectiveness of the proposed model was illustrated through numerical simulations. From the comparison with the operation data, the proposed model represents the paper plant being considered with sufficient accuracy.

파울링 가속장치를 이용한 공기조화기용 열교환기의 공기측 파울링 특성에 대한 예측 모델링 (Modeling of the Air-side Particulate Fouling in Finned-Tube Heat Exchangers of Air Conditioners using Accelerated Particle-Loading System)

  • 안영철;이재근
    • 설비공학논문집
    • /
    • 제17권3호
    • /
    • pp.262-267
    • /
    • 2005
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. The purpose of this study is to investigate and to model the air-side particulate fouling characteristics of the heat exchangers using accelerated particle loading system. The main variables of the modeling equation are face velocity and dust concentration. The modeling equation shows good agreements with the experimental results at the face velocity of 0.5, 1.0, 1.5 m/s and the dust concentration of 1.28 and $3.84\;g/m^3$. It will be very useful to predict fouling characteristics such as variations of pressure drop and heat transfer capacity in finned-tube heat exchangers of air conditioners.

다중 고체상을 고려한 소결기의 코크스 연소-열전달 모델링 (Modeling of Coke Combustion and Heat Transfer in an Iron Ore Sintering Bed with Considerations of Multiple Solid Phases)

  • 양원;류창국;최상민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.79-84
    • /
    • 2003
  • In this study we propose an unsteady I-dimensional model of an iron ore sintering bed with multiple solid phases, which confers a phase on each solid material. This model contains coke combustion, limestone decomposition, gaseous reaction, heat transfers between each phase, and geometric changes of the solid particles. Simulation results are compared with the limited experimental data set of various coke contents and air supply rates. Effect of the coke diameter is also evaluated. They predict the experimental results well and show applicabilities to the various system of the fuel bed with various solid materials.

  • PDF