• 제목/요약/키워드: heat storage rate

검색결과 319건 처리시간 0.022초

수소 저장합금층의 열전달 촉진을 위한 진동형 히트 파이프 적용에 관한 연구 (A Study of Application on the Pulsating Heat Pipe for Heat Transfer Enhancement of Metal Hydride Alloy)

  • 이민재;임용빈;배상철;김종수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.346-351
    • /
    • 2006
  • When metallic alloys are reacted to hydrogen, heat transfer of storage tank effects hydrogen storage rate and capacity. If pulsating heat pipe are used to improve heat transfer efficiency, production of hydrogen storage tank can be more simple and economical. Experiment of heat pipe was conducted by varying working fluids and heat flux. According to supply heat flux, test indicate that R-22 and R-l42b were found lower temperature difference between evaporator and condenser than R-134a and Ethanol. Thermal resistances of R-22 and R-142b were also lower than others. Using R-142b as a working fluid, heat pipe type hydrogen storage tank is tested in absorption and desorption processes.

  • PDF

낙동강 강정고령보의 여름철 열수지 일변화 - 열 저장량 변동을 중심으로 - (Daily Variation of Heat Budget Balance in the Gangjeong-Goryung Reservoir for Summertime - Concerning around the Rate of Heat Storage -)

  • 김성락;조창범;김해동
    • 한국환경과학회지
    • /
    • 제24권6호
    • /
    • pp.721-729
    • /
    • 2015
  • Surface heat balance of the Gangjeong-Goryung Reservoir is analyzed for 12-17 August 2013. Each flux elements at the water surface is derived from the special field observations with application of an aerodynamical bulk method for the turbulent heat fluxes and empirical formulae for the radiation heat fluxes. The rate of heat storage in the reservoir is estimated by using estimated by surface heating rate and the vertical water temperature data. The flux divergence of heat transport is estimated as a residual. The features of the surface heat balance are almost decided by the latent heat flux and the solar radiation flux. On average for 12-17 August 2014 in the Gangjeong- Goryung Reservoir, if one defines the insolation at the water surface as 100 %, 94 % is absorbed in the reservoir; thereafter the reservoir loses about 30~50% by sensible heat, latent heat and net long-wave radiation. The residue of 50~80 % raises the water temperature in the reservoir or transported away by the river flow during the daytime.

관외착빙형 빙축열조의 방열성능 모델링 (Modelling of Thermal Discharge Performance for Ice-on-coil Type Ice-Storage Tank)

  • 이상렬;이경호;최병윤;한승호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.280-285
    • /
    • 2001
  • This paper presents a modelling of thermal discharge performance for a static ice-on-coil ice-storage tank. Through the present study, discharging characteristics were examined with the existing results of theoretical and numerical heat transfer analyses. Also, an experiment was conducted to obtain a real set of discharge performance. The thermal effectiveness, the ratio of the actual heat transfer rate to the maximum possible heat transfer rate, decreased when the stored energy decreased during discharging period. And the effectiveness increased as the coolant flow rate through the storage increased, of which increasing rate decreased abruptly near the maximum and the minimum stored energy. An empirical correlation was obtained from the experimental and the numerical analysis data.

  • PDF

봉과 링 조합형 아이스캡슐을 적용한 축열시스템의 열전달 해석 (Heat Transfer Analysis of a Thermal Storage System using the Ice Capsule of Bar and Ring Module)

  • 김명수;최형권;변성광
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권2호
    • /
    • pp.268-275
    • /
    • 2008
  • The shape and array of ice capsules are very important factors in ice thermal storage system because the heat transfer rate of the system strongly depends upon them. In this paper, a new type of ice capsule composed of bar and ring module is proposed to increase the efficiency of the ice thermal storage system. To investigate the heat transfer rate of the proposed ice capsule, numerical analysis of the incompressible Navier-Stokes equations is performed to compare the proposed bar and ring system with the conventional ice capsules. It is shown that the ice capsule composed of bar and ring has a higher heat transfer rate and a low outlet temperature than the conventional ice capsules for various packing ratios and entrance velocities. Furthermore, it is found that the optimal entrance velocity exists between 0.005 m/s and 0.007 m/s from the present numerical analysis.

판형 열교환기에서 유동 과냉도 및 냉각속도가 연속제빙에 미치는 영향 (Effect of supercooling and cooling rate on a continuous ice slurry formation using a plate heat exchanger)

  • 이동규;백종현;홍희기;강채동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.138-143
    • /
    • 2006
  • The peculiarity of ice slurry, such as liquidity, high heat transfer rate and easy storage can also find to supercooled type dynamic ice storage system(DISS) which is one of the DISS. However, in order to accomplish continuous ice formation in the system without mechanical moving parts, supercooled aqueous solutionshould be formed stable through cooling heat exchanger and be dissoluted in storage tank. In previous research, the time of ice slurry increased as the pressure of the cooling heat exchanger(PHX) increased. In this study, a cooling experiment of an ethylene glycol 7mass% solution was performed with various inlet temperature of the PHX, which has constant brine inlet temperature of $-7^{\circ}C$. The temperature in the storage tank maintained to freezing point of the solution. At results, the time of ice slurry formation increased as the supercooling degree decreased and the cooling rate increased.

  • PDF

3중관 튜브형 잠열 축열조에서의 열전달 특성 연구 (Heat transfer characteristics of Triple-Tube Type Latent Heat Storage Tank)

  • 이욱균;한귀영;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제21권1호
    • /
    • pp.71-82
    • /
    • 2001
  • The heat transfer experiment in a latent heat storage tank as a solar energy storage system for the hot water supply was carried out. The latent heat storage tank was consisted of triple - tube type ; Outer shell for hot water from solar collector, PCM storage vessel in the middle of the tank and inside tube for hot water recovery. The heat storage tank has the dimension of 60 cm long and 34 cm outside diameter. Paraffin wax(m.p = 55.4C) and sodium acetate trihydrate(m.p = 58 C) were employed as the PCM this study. Experimental variables were inlet temperature and flow rate of the hot water for heat storage stage and cold water for heat recovery stage. Temperature profiles, heat transfer coefficient and the efficiency of heat storage$(Q/Q_{max})$ and heat recovery $(Q/Q_{max})$ were determined for the paraffin wax and inorganic salt respectively.

  • PDF

내부코일형 잠열 축열조에서의 열전달 특성 연구 (Heat transfer characteristics of Immersed Coil Type Latent Heat Storage Tank)

  • 이욱균;한귀영;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제21권1호
    • /
    • pp.83-91
    • /
    • 2001
  • The heat transfer experiment in a pilot scale latent heat storage tank as a solar energy storage system for the hot water supply was carried out. The latent heat storage tank was consisted of three parts; Outer shell for hot water from solar collector, PCM storage vessel in the middle of the tank and immersed coil in the PCM vessel for hot water recovery. The heat storage tank has the dimension of 115 cm in height and 32 cm outside diameter. Paraffin wax (m.p = 55.4C) and sodium acetate trihydrate (m.p = 58 C) were employed as the PCM this study. Experimental variables were inlet temperature and flow rate of the hot water for heat storage stage and cold water for heat recovery stage. Temperature profiles, heat transfer coefficient and the efficiency of heat storage $(Q/Q_{max})$ and heat recovery $(Q/Q_{max})$ were determined for the paraffin wax and inorganic salt respectively.

  • PDF

빙축 및 냉방열과정중 냉각유체와 Ice Ball사이의 열적 특성에 관한 실험적 연구 (An Experimental Study on Thermal Characteristics between Cooling Fluid and Ice Ball during Charging and Discharging Precesses)

  • 박경원;박이동;황영규;김윤제
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1996년도 추계학술발표회 논문집
    • /
    • pp.193-205
    • /
    • 1996
  • This paper deals with experimental study on thermal characteristics that a cooling fluid is affected to ice ball as being measuring the temperature in storage tank and ice ball governing the rate of heat storage. Distributor was taken as inlet geometry factor. flow rate of cooling fluid which was a brine were 2, 4, and 6LPM, and 8, 10, and 12$^{\circ}C$ in the temperature difference for dynamic factors with respect to three ice ball types(103, 96, 76mm). In case of in flowing cooling fluid, since inertia force is suppressed by lower flow rate the amount of heat was transferred to ice ball by heat conduction high because density difference is high. And in case of larger ice ball, a long-term storage was available because reaching time at steady state is relatively long. consequently, smaller ice ball could be suitable to a short-term storage.

  • PDF

HEAT REMOVAL TEST USING A HALF SCALE STORAGE CASK

  • Bang, K.S.;Lee, J.C.;Seo, K.S.;Cho, C.H.;Lee, S.J.;Kim, J.M.
    • Nuclear Engineering and Technology
    • /
    • 제39권2호
    • /
    • pp.143-148
    • /
    • 2007
  • Spent nuclear fuel generated at nuclear power plants must be safely stored during interim storage periods. A dry storage cask to safely store the spent nuclear fuel should be able to adequately emit the decay heat from the spent nuclear fuel. Therefore, heat removal tests using a half scale dry storage cask have been performed to estimate the heat transfer characteristics of a dry storage cask under normal, off-normal, and accident conditions. In the normal condition, the heat transfer rate to an ambient atmosphere by convective air through a passive heat removal system reached 83%. Accordingly, the passive heat removal system is designed well and works adequately. In the off-normal condition, the influence of a half blockage in the inlet on the temperature appears minimal. In the accident condition, the temperature rose for 12 hours after the accident, but the temperature rise steadied after 36 hours.

CA저장 기체조성에 따른 사과 Fuji의 증산속도 (Effects of Storage Gas Concentrations on the Transpiration Rate of Fuji Apple during CA Storage)

  • 강준수;정헌식;최종욱
    • 한국식품저장유통학회지
    • /
    • 제9권3호
    • /
    • pp.261-266
    • /
    • 2002
  • CA저장 중 저장기체 조성에 따른 사과 Fuji의 증산속도를 측정하고, 같은 조건에서 증산속도를 예측하기 위한 수학적 모델을 설정하여 증산속도를 예측하였다. 온도 $0^{\circ}C$, 상대습도 98%, 공기 유속 0.25m/s의 저장조건에서 6주 동안 CA저장하였을 때 사과 Fuji의 호흡속도는 일반저온저장에 비하여 50%이하로 낮출 수 있었다. 같은 저장조건에서 일반저온저장에서의 사과의 증산속도가 CA저장에 비하여 50~70 % 높았으며, 일정한 산소농도의 CA저장에서는 저장기체 중 이산화탄소농도가 높을수록 증산속도는 감소하는 것으로 나타났다. 본 연구에서 채택한 모델로 예측한 증산속도는 실측치와 유사한 값을 나타내어 본 연구에서 채택한 모델로 CA 저장 중 저장기체 조성에 따른 사과 Fuji의 증산속도를 잘 예측할 수 있었다. 사과의 증산속도는 호흡열량에 비례하여 증가하는 경향을 나타내었으나 증산속도의 증가폭은 호흡열량의 증가폭에 미치지 못하였다. 이는 호흡열량이 증가하면 사과의 증발표면의 온도가 높아져서 증산속도가 커질 수 있게 되지만, 증산속도의 증가에 따른 증발잠열의 증가가 증발표면의 온도를 미세하게 낮추어 주므로 일어나는 현상으로 볼 수 있다.